High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

Ozone↗

Global Free Tropospheric NO2 Abundances Derived Using a Cloud Slicing Technique Applied to Satellite Observations from the Aura Ozone Monitoring Instrument (OMI)

We derive free-tropospheric NO2 volume mixing ratios (VMRs) and stratospheric column amounts of NO2 by applying a cloud slicing technique to data from the Ozone Monitoring Instrument (OMI) on the Aura satellite. In the cloud-slicing approach, the slope of the above-cloud NO2 column versus the cloud scene pressure is proportional to the NO2 VMR. In this work, we use a sample of nearby OMI pixel data from a single orbit for the linear fit. The OMI data include cloud scene pressures from the rotational-Raman algorithm and above-cloud NO2 vertical column density (VCD) (defined as the NO2 column from the cloud scene pressure to the top-of-the-atmosphere) from a differential optical absorption spectroscopy (DOAS) algorithm. Estimates of stratospheric column NO2 are obtained by extrapolating the linear fits to the tropopause. We compare OMI-derived NO2 VMRs with in situ aircraft profiles measured during the NASA Intercontinental Chemical Transport Experiment Phase B (INTEX-B) campaign in 2006. The agreement is generally within the estimated uncertainties when appropriate data screening is applied. We then derive a global seasonal climatology of free-tropospheric NO2 VMR in cloudy conditions. Enhanced NO2 in the free troposphere commonly appears near polluted urban locations where NO2 produced in the boundary layer may be transported vertically out of the boundary layer and then horizontally away from the source. Signatures of lightning NO2 are also shown throughout low and middle latitude regions in summer months. A profile analysis of our cloud slicing data indicates signatures of uplifted and transported anthropogenic NO2 in the middle troposphere as well as lightning-generated NO2 in the upper troposphere. Comparison of the climatology with simulations from the Global Modeling Initiative (GMI) for cloudy conditions (cloud optical thicknesses > 10) shows similarities in the spatial patterns of continental pollution outflow. However, there are also some differences in the seasonal variation of free-tropospheric NO2 VMRs near highly populated regions and in areas affected by lightning-generated NOx. Stratospheric column NO2 obtained from cloud slicing agrees well with other independently-generated estimates, providing further confidence in the free-tropospheric results.

NO2↗

Global Free-tropospheric NO2 Abundances Derived Using a Cloud Slicing Technique from AURA OMI

We derive free-tropospheric NO2 volume mixing ratios (VMRs) by applying a cloud-slicing technique to data from the Ozone Monitoring Instrument (OMI) on the Aura satellite. In the cloud-slicing approach, the slope of the above-cloud NO2 column versus the cloud scene pressure is proportional to the NO2 VMR. In this work, we use a sample of nearby OMI pixel data from a single orbit for the linear fit. The OMI data include cloud scene pressures from the rotational-Raman algorithm and above-cloud NO2 vertical column density (VCD) (defined as the NO2 column from the cloud scene pressure to the top of the atmosphere) from a differential optical absorption spectroscopy (DOAS) algorithm. We compare OMI-derived NO2 VMRs with in situ aircraft profiles measured during the NASA Intercontinental Chemical Transport Experiment Phase B (INTEX-B) campaign in 2006. The agreement is generally within the estimated uncertainties when appropriate data screening is applied. We then derive a global seasonal climatology of free-tropospheric NO2 VMR in cloudy conditions. Enhanced NO2 in the free troposphere commonly appears near polluted urban locations where NO2 produced in the boundary layer may be transported vertically out of the boundary layer and then horizontally away from the source. Signatures of lightning NO2 are also shown throughout low and middle latitude regions in summer months. A profile analysis of our cloud-slicing data indicates signatures of lightning-generated NO2 in the upper troposphere. Comparison of the climatology with simulations from the global modeling initiative (GMI) for cloudy conditions (cloud optical depth less than10) shows similarities in the spatial patterns of continental pollution outflow. However, there are also some differences in the seasonal variation of free-tropospheric NO2 VMRs near highly populated regions and in areas affected by lightning-generated NOx.

NO2↗

OMI Measurements of Bromine Monoxide and Implications for Missing Sources of Polar Bromine in GEOS-Chem

The OMI satellite instrument provides total column measurements of bromine monoxide (BrO) with daily global coverage. Reactive bromine compounds (Br and BrO) catalytically destroy ozone in both the stratosphere and troposphere. The current emission scheme of brominated source gases in the GEOS-Chem chemical transport model well represents the stratospheric burden of bromine. However, halogen research in GEOS-Chem has largely focused on the influence of halogens on the tropospheric oxidative capacity. In the troposphere, the distribution of brominated compounds is more variable and significant uncertainties remain in the chemical processes governing the sources and sinks of reactive bromine compounds. In this study, we use GEOS-Chem simulated stratospheric columns of BrO to separate the tropospheric signal of BrO from the OMI total column measurements. The resulting tropospheric BrO columns are used to identify seasonal and regional anomalies in tropospheric BrO not currently represented in GEOS-Chem. In particular, periods of elevated tropospheric BrO during polar spring are observable by OMI, and past studies have connected these so-called "bromine explosion" events to near complete removal of surface ozone. Due to significant uncertainties in the springtime polar source of reactive bromine, many global models, including GEOS-Chem, do not simulate these tropospheric ozone depletion events. Consequently, OMI-based tropospheric columns of BrO are useful tool for investigating the impact of bromine explosion events on tropospheric ozone depletion episodes as well as background air quality.

Wales, Pamela↗

Ozone Monitoring Instrument (OMI) collection 4: establishing a 17-year-long series of detrended level-1b data

The Ozone Monitoring Instrument (OMI) was launched on 15 July 2004, with an expected mission lifetime of 5 years. After more than 17 years in orbit the instrument is still functioning satisfactorily and in principle can continue doing so until the expected decommissioning of its platform Aura in 2025. In order to continue the datasets acquired by OMI and the Microwave Limb Sounder, the mission was extended up to at least 2023. Actions have been taken to ensure the proper functioning of the OMI operations, the data processing, and the calibration monitoring system until the eventual end of the mission. For the data processing a new level-0 (L0) to level-1b (L1b) data processor was built based on the recent developments for the TROPOspheric Monitoring Instrument (TROPOMI). With corrections for the degradation of the instrument now included, it is feasible to generate a new data collection to supersede the current collection-3 data products and reprocess the data of the entire mission up to now. This paper describes the differences between the collection-3 and collection-4 data. It will be shown that the collection-4 L1b data comprise a clear improvement with respect to the previous collections. By correcting for the gentle optical and electronic aging that has occurred over the past 17 years, OMI’s ability to make trend-quality ozone measurements has further improved.

UV↗

Application of OMI, SCIAMACHY and GOME-2 Satellite SO2 Retrievals for Detection of Large Emission Sources

Retrievals of sulfur dioxide (SO2) from space-based spectrometers are in a relatively early stage of development. Factors such as interference between ozone and SO2 in the retrieval algorithms often lead to errors in the retrieved values. Measurements from the Ozone Monitoring Instrument (OMI), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), and Global Ozone Monitoring Experiment-2 (GOME-2) satellite sensors, averaged over a period of several years, were used to identify locations with elevated SO2 values and estimate their emission levels. About 30 such locations, detectable by all three sensors and linked to volcanic and anthropogenic sources, were found after applying low and high spatial frequency filtration designed to reduce noise and bias and to enhance weak signals to SO2 data from each instrument. Quantitatively, the mean amount of SO2 in the vicinity of the sources, estimated from the three instruments, is in general agreement. However, its better spatial resolution makes it possible for OMI to detect smaller sources and with additional detail as compared to the other two instruments. Over some regions of China, SCIAMACHY and GOME-2 data show mean SO2 values that are almost 1.5 times higher than those from OMI, but the suggested spatial filtration technique largely reconciles these differences.

SO2 retrievals↗

The Observed Response of Ozone Monitoring Instrument (OMI) NO2 Columns to NOx Emission Controls on Power Plants in the United States: 2005-2011

We show that Aura Ozone Monitoring Instrument (OMI) nitrogen dioxide (NO2) tropospheric column data may be used to assess changes of the emissions of nitrogen oxides (NOx) from power plants in the United States, though careful interpretation of the data is necessary. There is a clear response for OMI NO2 data to NOx emission reductions from power plants associated with the implementation of mandated emission control devices (ECDs) over the OMI record (2005e2011). This response is scalar for all intents and purposes, whether the reduction is rapid or incremental over several years. However, it is variable among the power plants, even for those with the greatest absolute decrease in emissions. We document the primary causes of this variability, presenting case examples for specific power plants.

remote sensing↗

Assessment of 10 Year Record of Aerosol Optical Depth from OMI UV Observations

The Ozone Monitoring Instrument (OMI) onboard the EOS-Aura satellite provides information on aerosol optical properties by making use of the large sensitivity to aerosol absorption in the near-ultraviolet (UV) spectral region. Another important advantage of using near UV observations for aerosol characterization is the low surface albedo of all terrestrial surfaces in this spectral region that reduces retrieval errors associated with land surface reflectance characterization. In spite of the 13 × 24 square kilometers coarse sensor footprint, the OMI near UV aerosol algorithm (OMAERUV) retrieves aerosol optical depth (AOD) and single-scattering albedo under cloud-free conditions from radiance measurements at 354 and 388 nanometers. We present validation results of OMI AOD against space and time collocated Aerosol Robotic Network measured AOD values over multiple stations representing major aerosol episodes and regimes. OMAERUV's performance is also evaluated with respect to those of the Aqua-MODIS Deep Blue and Terra-MISR AOD algorithms over arid and semi-arid regions in Northern Africa. The outcome of the evaluation analysis indicates that in spite of the "row anomaly" problem, affecting the sensor since mid-2007, the long-term aerosol record shows remarkable sensor stability.

aerosol optical depth↗

Merging of OMI and AIRS Ozone Data

The OMI Instrument measures ozone using the backscattered light in the UV part of the spectrum. In polar night there are no OMI measurements so we hope to incorporate the AIRS ozone data to fill in these missing regions. AIRS is on the Aqua platform and has been operating since May 2002. AIRS is a multi-detector array grating spectrometer containing 2378 IR channels between 650 per centimeter and 2760 per centimeter which measures atmospheric temperature, precipitable water, water vapor, CO, CH4, CO2 and ozone profiles and column amount. It can also measure effective cloud fraction and cloud top pressure for up to two cloud layers and sea-land skin temperature. Since 2008, OMI has had part of its aperture occulted with a piece of the thermal blanket resulting in several scan positions being unusable. We hope to use the AIRS data to fill in the missing ozone values for those missing scan positions.

OMI↗

Assessment of OMI Near-UV Aerosol Optical Depth over Land

This is the first comprehensive assessment of the aerosol optical depth (AOD) product retrieved from the near-UV observations by the Ozone Monitoring Instrument (OMI) onboard the Aura satellite. The OMI-retrieved AOD by the ultraviolet (UV) aerosol algorithm (OMAERUV version 1.4.2) was evaluated using collocated Aerosol Robotic Network (AERONET) level 2.0 direct Sun AOD measurements over 8 years (2005-2012). A time series analysis of collocated satellite and ground-based AOD observations over 8 years shows no discernible drift in OMI's calibration. A rigorous validation analysis over 4 years (2005-2008) was carried out at 44 globally distributed AERONET land sites. The chosen locations are representative of major aerosol types such as smoke from biomass burning or wildfires, desert mineral dust, and urban/industrial pollutants. Correlation coefficient (p) values of 0.75 or better were obtained at 50 percent of the sites with about 33 percent of the sites in the analysis reporting regression line slope values larger than 0.70 but always less than unity. The combined AERONET-OMAERUV analysis of the 44 sites yielded a p of 0.81, slope of 0.79, Y intercept of 0.10, and 65 percent OMAERUV AOD falling within the expected uncertainty range (largest of 30 percent or 0.1) at 440 nanometers. The most accurate OMAERUV retrievals are reported over northern Africa locations where the predominant aerosol type is desert dust and cloud presence is less frequent. Reliable retrievals were documented at many sites characterized by urban-type aerosols with low to moderate AOD values, concentrated in the boundary layer. These results confirm that the near-ultraviolet observations are sensitive to the entire aerosol column. A simultaneous comparison of OMAERUV, Moderate Resolution Imaging Spectroradiometer (MODIS) Deep Blue, and Multiangle Imaging Spectroradiometer (MISR) AOD retrievals to AERONET measurements was also carried out to evaluate the OMAERUV accuracy in relation to those of the standard aerosol satellite products. The outcome of the comparison indicates that OMAERUV, MODIS Deep Blue, and MISR retrieval accuracies in arid and semiarid environments are statistically comparable.

aerosol optical depth↗

Exploiting OMI NO2 Satellite Observations to Infer Fossil-fuel CO2 Emissions from U.S. Megacities

Fossil-fuel CO2 emissions and their trends in eight U.S. megacities during 2006–2017 are inferred by combining satellite-derived NOX emissions with bottom-up city-specific NOX-to-CO2 emission ratios. A statistical model is fit to a collection NO2 plumes observed from the Ozone Monitoring Instrument (OMI), and is used to calculate top-down NOX emissions. Decreases in OMI-derived NOX emissions are observed across the eight cities from 2006 to 2017 (−17% in Miami to −58% in Los Angeles), and are generally consistent with long-term trends of bottom-up inventories (−25% in Miami to −49% in Los Angeles), but there are some interannual discrepancies. City-specific NOX-to-CO2 emission ratios, used to calculate inferred CO2, are estimated through annual bottom-up inventories of NOX and CO2 emissions disaggregated to 1 × 1 km2 resolution. Over the study period, NOX-to-CO2 emission ratios have decreased by ~40% nationwide (−24% to −51% for our studied cities), which is attributed to a faster reduction in NOX when compared to CO2 due to policy regulations and fuel type shifts. Combining top-down NOX emissions and bottom-up NOX-to-CO2 emission ratios, annual fossil-fuel CO2 emissions are derived. Inferred OMI-based top-down CO2 emissions trends vary between +7% in Dallas to −31% in Phoenix. For 2017, we report annual fossil-fuel CO2 emissions to be: Los Angeles 113 ± 49 Tg/yr; New York City 144 ± 62 Tg/yr; and Chicago 55 ± 24 Tg/yr. A study in the Los Angeles area, using independent methods, reported a 2013–2016 average CO2 emissions rate of 104 Tg/yr and 120 Tg/yr, which suggests that the CO2 emissions from our method are in good agreement with other studies' top-down estimates. We anticipate future remote sensing instruments – with better spatial and temporal resolution – will better constrain the NOX-to-CO2 ratio and reduce the uncertainty in our method.

Ozone Monitoring Instrument (OMI)↗

Explicit Aerosol Correction of OMI Formaldehyde Retrievals

Atmospheric aerosols are significant sources of uncertainty in air mass factor (AMF) calculations for trace gas retrievals using ultraviolet measurements from space. Current trace gas retrievals typically do not consider aerosols explicitly as cloud products partially account for aerosol effects. Here, we propose a new measurement-based approach to correct for aerosols explicitly in the AMF calculation, apply it to Ozone Monitoring Instrument (OMI) formaldehyde (HCHO) retrievals and quantify the aerosol-induced HCHO vertical column density difference for three aerosol types (smoke, dust, and sulfate) during 2006–2007. We use OMI aerosol retrievals for aerosol optical properties and vertical profiles to construct lookup tables of scattering weights as functions of geometry, surface pressure, surface albedo, and aerosol information. The average difference between the National Aeronautics and Space Administration operational OMI HCHO product (not considering aerosols) and the results obtained in this study on a global scale are 27%, 6%, and −0.3% for smoke, dust, and sulfate aerosols, respectively. The region with the largest aerosol effects is East China, where the explicit smoke aerosol correction enhances mean HCHO vertical column densities by 35%, with corrections to individual observations sometimes larger than 100%. The quantified aerosol effects are applicable under clear-sky conditions. This study highlights the need to implement aerosol corrections in the AMF calculation for HCHO retrievals. This is particularly relevant in regions with high levels of pollution where aerosols interfere the most with formaldehyde satellite observations.

Ozone Monitoring Instrument (OMI) formaldehyde (HC↗

Comparing Satellite Measurements of Volcanic SO2 Mass from OMI, OMPS and TROPOMI

Sulfur dioxide (SO2) is a major air pollutant that contributes to acid rain and aerosol formation (e.g., sulfates), adversely affects the environment and human health, and explosive volcanic SO2 emissions can impact climate. The majority of SO2 emissions are related to anthropogenic processes (e.g., fossil fuel burning, metal ore smelting operations), although natural processes such as volcanic eruptions and degassing also play an important role as anthropogenic SO2 emissions continue to decline. Generally, the most interest in volcanoes occurs during major eruptions. We will focus on comparing volcanic SO2 outgassing that occurs on an almost daily basis from lesser known volcanoes using satellite data. At NASA’s Global Sulfur Dioxide Monitoring Home page (https://so2.gsfc.nasa.gov/), we have been posting daily SO2 maps from 40 volcanic and industrial regions around the world using measurements from three satellite instruments; the Ozone Monitoring Instrument (OMI) onboard NASA’s Earth Observing System Aura satellite, the Ozone Monitoring and Profiler Suite (OMPS) onboard the NASA-NOAA Suomi National Polar-orbiting Partnership (NPP) satellite, and the TROPOspheric Monitoring Instrument (TROPOMI) onboard the ESA/Copernicus Sentinel-5 Precursor satellite. These instruments in low Earth sun-synchronous polar orbits with 1:30-2:00 pm equator crossing local time provide daily SO2 maps at different spatial resolutions: 13 x 24 km2, 50 x 50 km2 and 5.5 x 3.5 km2 for OMI, OMPS and TROPOMI respectively. Data from OMI are available since October 2004 (partial coverage since 2008), from OMPS since 2012 and from TROPOMI since 2018. We will present comparative SO2 mass time-series (see Hunga-Tonga plot) and statistical analyses of recent eruptions that have data from all the instruments.

SO2↗

EOS-Aura's Ozone Monitoring Instrument (OMI): Validation Requirements

OMI is an advanced hyperspectral instrument that measures backscattered radiation in the UV and visible. It will be flown as part of the EOS Aura mission and provide data on atmospheric chemistry that is highly synergistic with other Aura instruments HIRDLS, MLS, and TES. OMI is designed to measure total ozone, aerosols, cloud information, and UV irradiances, continuing the TOMS series of global mapped products but with higher spatial resolution. In addition its hyperspectral capability enables measurements of trace gases such as SO2, NO2, HCHO, BrO, and OClO. A plan for validation of the various OM1 products is now being formulated. Validation of the total column and UVB products will rely heavily on existing networks of instruments, like NDSC. NASA and its European partners are planning aircraft missions for the validation of Aura instruments. New instruments and techniques (DOAS systems for example) will need to be developed, both ground and aircraft based. Lidar systems are needed for validation of the vertical distributions of ozone, aerosols, NO2 and possibly SO2. The validation emphasis will be on the retrieval of these products under polluted conditions. This is challenging because they often depend on the tropospheric profiles of the product in question, and because of large spatial variations in the troposphere. Most existing ground stations are located in, and equipped for, pristine environments. This is also true for almost all NDSC stations. OMI validation will need ground based sites in polluted environments and specially developed instruments, complementing the existing instrumentation.

Brinksma, E. J.↗

First Global Maps of Stratospheric and Tropospheric NO2 from OMI

The Ozone Monitoring Instrument (OMI) was launched successfully in July 2004, as one of four instruments on the EOS Aura satellite. OMI makes hyperspectral measurements that are used to retrieve column densities of critical trace gases, including formaldehyde, BrO, SO2 and NO2 . We present the first results from the OM1 operational NO2 algorithm and demonstrate its ability to retrieve the tropospheric and stratospheric components of NO2. The DOAS method is used to determine slant column densities, and initial air mass factors (AMFs) are used. to give initial estimates of the vertical column densities (VCDs). VCDs from up to 15 consecutive orbits are collected, and a spatial filtering technique is applied to extract the synoptic-scale features characteristic of the stratospheric, field. features to be evidence of tropospheric excess NO2 , and apply an AMF appropriate to polluted conditions, to obtain an improved retrieval of the NO2 total VCD. We describe the assumptions underlying the algorithm in detail, and show global maps of NO2 VCDs, based on the first operational data from OMI.

Bucsela, Eric J.↗

First Look at the Upper Tropospheric Ozone Mixing Ratio from OMI Estimated using the Cloud Slicing Technique

The Cloud Slicing technique has emerged as a powerful tool for the study of ozone in the upper troposphere. In this technique one looks at the variation with cloud height of the above-cloud column ozone derived from the backscattered ultraviolet instruments, such as TOMS, to determine the ozone mixing ratio. For this technique to work properly one needs an instrument with relatively good horizontal resolution with very good signal to noise in measuring above-cloud column ozone. In addition, one needs the (radiatively) effective cloud pressure rather than the cloud-top pressure, for the ultraviolet photons received by a satellite instrument are scattered from inside the cloud rather than from the top. For this study we use data from the OMI sensor, which was recently launched on the EOS Aura satellite. OMI is a W-Visible backscattering instrument with a nadir pixel size of 13 x 24 km. The effective cloud pressure is derived from a new algorithm based on Rotational Raman Scattering and O2-O2, absorption in the 340-400 nm band of OMI.

Bhartia, Pawan K.↗

Direct Observations of PMC Local Time Variations by Aura OMI

The Ozone Monitoring Instrument (OMI) on the Aura satellite obtains unique measurements for polar mesospheric cloud (PMC) analysis. Its wide cross-track viewing swath and high along-track spatial resolution makes it possible to directly evaluate PMC occurrence frequency and brightness variations between 6S" and 8S' latitude as a function of local time over a 12-14 h continuous period. OMI PMC local time variations are closely coupled to concurrent variations in measurement scattering angle, so that ice phase function effects must be considered when interpreting the observations. Two different phase functions corresponding to bright and faint clouds are examined in this analysis. OMI observations show maximum frequency and albedo values at 8-10 h local time in the Northern Hemisphere, with decreasing amplitude at higher latitudes. Southern Hemisphere values reach a minimum at 18-20 h LT. Larger variations are seen in Northern Hemisphere data. No statistically significant longitudinal dependence was seen.

DeLand, Matthew T.↗

Improvement of OMI Ozone Profile Retrievals in the Troposphere and Lower Troposphere by the Use of the Tropopause-Based Ozone Profile Climatology

An advance algorithm based on the optimal estimation technique has beeen developed to derive ozone profile from GOME UV radiances and have adapted it to OMI UV radiances. OMI vertical resolution : 7-11 km in the troposphere and 10-14 km in the stratosphere. Satellite ultraviolet measurements (GOME, OMI) contain little vertical information for the small scale of ozone, especially in the upper troposphere (UT) and lower stratosphere (LS) where the sharp O3 gradient across the tropopause and large ozone variability are observed. Therefore, retrievals depend greatly on the a-priori knowledge in the UTLS

Bak, Juseon↗