Continuous pH monitoring in a perfused bioreactor system using an optical pH sensor

Monitoring and regulating the pH of the solution in a bioprocess is one of the key steps in the success of bioreactor operation. An in-line optical pH sensor, based on the optical absorption properties of phenol red present in the medium, was developed and tested in this work for use in NASA space bioreactors based on a rotating wall-perfused vessel system supporting a baby hamster kidney (BHK-21) cell culture. The sensor was tested over three 30-day and one 124-day cell runs. The pH sensor initially was calibrated and then used during the entire cell culture interval. The pH reported by the sensor was compared to that measured by a fiber optically coupled Shimadzu spectrophotometer and a blood gas analyzer. The maximum standard error of prediction for all the four cell runs for development pH sensor against BGA was +/-0.06 pH unit and for the fiber optically coupled Shimadzu spectrophotometer against the blood gas analyzer was +/-0.05 pH unit. The pH sensor system performed well without need of recalibration for 124 days. Copyright 2002 Wiley Periodicals, Inc.

Bioreactors↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗

Ultrasonic coupling to optically generated charge carriers in CdS: Physical phenomena and applications

Phonon-charge carrier interactions are studied as well as ultrasonic resonators. Sensitivity enhancement factors predicted by one dimensional resonator theory are verified and several sensitive ultrasonic experimental techniques are developed. Measurements are reported of an anomalous sign reversal of the acoustoelectric voltage in a CdS resonator. Applications of CdS as an ultrasonic power detector are described.

Heyman, J. S.↗

The Effect of Different Materials on the Accuracy of the HYDRA Optical-Fiber-Coupled Coherent Range/Pressure Measurement System and the Development of the Health Care Database System at Old Dominion University

The objective of the first project involving the HYDRA laser system was to determine what effects, if any, could been seen in the system's measurements when testing was done with objects composed of different materials. Ideally we would like to have seen that the range of measurements were all within the accepted 0.4 millimeter accuracy of the system. Unfortunately our results were not as we had hoped, and there did appear to be some significant difference in the measurements made on objects composed of different materials. The second project is a continuing project at Old Dominion University. The ultimate goal is to develop a medical database that allows a doctor or hospital to keep medical records on line. The current data of the system consisted of one patient whose medical data had been hard coded to allow for a demonstration of the potentials of the system. The short term goal for this summer was to add additional patients to the system for testing, and to eliminate the hard coding of data by creating a database where data could be stored and queried to produce the results seen in the current state.

Johnson, Kimberly D.↗

Dispersion-Enhanced Laser Gyroscope

We analyze the effect of a highly dispersive element placed inside a modulated optical cavity on the frequency and amplitude of the output modulation to determine the conditions for enhanced gyroscopic sensitivities. The element is treated as both a phase and amplitude filter, and the time-dependence of the cavity field is considered. Both atomic gases (two-level and multi-level) and optical resonators (single and coupled) are considered and compared as dispersive elements. We find that it is possible to simultaneously enhance the gyro scale factor sensitivity and suppress the dead band by using an element with anomalous dispersion that has greater loss at the carrier frequency than at the side-band frequencies, i.e., an element that simultaneously pushes and intensifies the perturbed cavity modes, e.g. a two-level absorber or an under-coupled optical resonator. The sensitivity enhancement is inversely proportional to the effective group index, becoming infinite at a group index of zero. However, the number of round trips required to reach a steady-state also becomes infinite when the group index is zero (or two). For even larger dispersions a steady-state cannot be achieved, and nonlinear dynamic effects such as bistability and periodic oscillations are predicted in the gyro response.

Smith, David D.↗

Optical filter having coupled whispering-gallery-mode resonators

Optical filters having at least two coupled whispering-gallery-mode (WGM) optical resonators to produce a second order or higher order filter function with a desired spectral profile. At least one of the coupled WGM optical resonators may be tunable by a control signal to adjust the filtering function.

Savchenkov, Anatoliy↗

The Haleakala Stokes polarimeter

A versatile Stokes polarimeter for solar observations has been developed. Recent improvements to the instrument include a high-resolution echelle spectrometer coupled to the telescope by optical fibers, and 128-element diode array detectors. The on-axis design on the telescope and polarimeter limit instrumental polarization to .0001, and the spectrometer detector combination provides spectral resolving power of 160,000 for any wavelength between 4000 and 11,000 A. This paper describes the Haleakala polarimeter and in particular the spectrometer with its fiber-optic coupling. Examples of Stokes line profiles observed in a sunspot are presented, together with derived vector magnetic field maps.

Mickey, D. L.↗

R.F Microphotonics for NASA Space Communications Applications

An RF microphotonic receiver has-been developed at Ka-band. The receiver consists of a lithium niobate micro-disk that enables RF-optical coupling to occur. The modulated optical signal (- 200 THz) is detected by the high-speed photonic signal processing electronics. When compared with an electronic approach, the microphotonic receiver technology offers 10 times smaller volume, smaller weight, and smaller power consumption; greater sensitivity; and optical isolation for use in extreme environments. The status of the technology development will be summarized, and the potential application of the receiver to NASA space communications systems will be described.

Pouch, John↗

Technology Development of Stratified Volume Diffractive Optics for Waveguide Coupling

Stratified Volume Diffractive Optical Elements (SVDOE) appear to be viable as high-efficiency waveguide couplers. Preliminary design studies were conducted under this task to provide initial device parameters for evaluation. However, these designs should be revisited prior to fabrication of a device for testing. The emphasis of this task has been development and implementation of fabrication procedures necessary for SVDOE'S, namely alignment of grating layers, Including offsets, to within required tolerances. Progress in this area Indicates that the alignment technique chosen is viable and tolerances have been reached that allow reasonable performance ranges. Approaches have been identified to improve alignment tolerances even further.

Chambers, Diana M.↗

AWG Filter for Wavelength Interrogator

A wavelength interrogator is coupled to a circulator which couples optical energy from a broadband source to an optical fiber having a plurality of sensors, each sensor reflecting optical energy at a unique wavelength and directing the reflected optical energy to an AWG. The AWG has a detector coupled to each output, and the reflected optical energy from each grating is coupled to the skirt edge response of the AWG such that the adjacent channel responses form a complementary pair response. The complementary pair response is used to convert an AWG skirt response to a wavelength.

Black, Richard J.↗

Multimodal characterization of Te inclusions in Cd 1−x Zn x Te and Cd 1−x Zn x Te 1−y Se y for gamma and X-ray detectors

While CdZnTe (CZT) and CdZnTeSe (CZTS) semiconductors have emerged as compounds for room-temperature gamma and X-ray detection materials, they continue to be constrained by the formation of Te-inclusion defects generated during the growth and post-growth phases of the material, which adversely affect the detector performance. We demonstrate the utility of multimodal microscopic imaging and analysis for the characterization of the optical and electronic properties of Te inclusions in CZT and CZTS crystals at both micron and nanometer length scales. Having first identified regions with micron-scale Te inclusions using confocal Raman microscopy techniques, optically coupled infrared scattering near-field optical microscopic mapping was performed to map the distribution of these inclusions with nanometer spatial resolution and correlate the presence of Te inclusions in the matrix with other properties. Kelvin probe force microscopy was then utilized to characterize the variations of the work function associated with the presence of Te inclusions. Here, we observe an increase of ~ 240 mV in the work function associated with Te inclusions compared to the bulk CZT/CZTS crystals. Additionally, we observe that individual bulk grains in CZT can exhibit slight potential variations. Our findings develop a portrait of the charge trapping mechanisms in CZT and CZTS that act to degrade detector performance, while the demonstration of these combined microscopy techniques provides a new analytical tool that can be utilized for further optimization of the detector performance for these semiconducting compounds.

36 MATERIALS SCIENCE↗

Observation of Anisotropic Dispersive Dark-Exciton Dynamics in CrSBr

Many-body excitons in CrSBr are attracting intense interest in view of their highly anisotropic magneto-optical coupling and their potential for novel optical interfaces within spintronic and magnonic devices. Characterizing the orbital character and propagation of these electronic excitations is crucial for understanding and controlling their behavior; however, this information is challenging to access. High resolution resonant inelastic x-ray scattering is a momentum-resolved technique that can address these crucial questions. Here, we present measurements collected at the Cr 𝐿 3 -edge which show a rich spectrum of excitations with a variety of spin-orbital characters. While most of these excitations appear to be localized, the dispersion of the lowest energy dark exciton indicates that it is able to propagate along both the 𝑎 and 𝑏 directions within the planes of the crystal. This two-dimensional character is surprising as it contrasts with electrical conductivity and the behavior of the bright exciton, both of which are strongly one dimensional. The discovery of this propagating dark exciton highlights an unusual coexistence of one- and two-dimensional electronic behaviors in CrSBr.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid Prototyping for Nanoparticle-Based Photonic Crystal Fiber Sensors

The advent of nanotechnology has motivated a revolution in the development of miniaturized sensors. Such sensors can be used for radiation detection, temperature sensing, radio-frequency sensing, strain sensing, and more. At the nanoscale, integrating the materials of interest into sensing platforms can be a common issue. One promising platform is photonic crystal fibers, which can draw in optically sensitive nanoparticles or have its optical properties changed by specialized nanomaterials. However, testing these sensors at scale is limited by the the need for specialized equipment to integrate these photonic crystal fibers into optical fiber systems. Having a method to enable rapid prototyping of new nanoparticle-based sensors in photonic crystal fibers would open up the field to a wider range of laboratories that could not have initially studied these materials in such a way before. This manuscript discusses the improved processes for cleaving, drawing, and rapidly integrating nanoparticle-based photonic crystal fibers into optical system setups. The method proposed in this manuscript achieved the following innovations: cleaving at a quality needed for nanoparticle integration could be done more reliably (≈100% acceptable cleaving yield versus ≈50% conventionally), nanoparticles could be drawn at scale through photonic crystal fibers in a safe manner (a method to draw multiple photonic crystal fibers at scale versus one fiber at a time), and the new photonic crystal fiber mount was able to be finely adjusted when increasing the optical coupling before inserting it into an optical system (before, expensive fusion splicing was the only other method).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Target Configuration Effect on Microstructures and Properties of Vertically Aligned Nanocomposites

Vertically aligned nanocomposites (VANs) are unique thin films with vertical nanostructures embedded in a matrix material, allowing for the integration of two distinct materials. These nanocomposites offer novel combined physical properties, such as nanocomposite-based multiferroics and strongly coupled physical properties, such as magneto-optic coupling. Much work has been conducted in exploring different two-phase combinations and various processing conditions to achieve novel tunable properties that cannot be obtained by any single-phase material alone. Here, in this work, the target configuration effects are explored for the growth of LaFeO 3 –CoNi 2 O 4 VANs. Both mixed and pie-shaped targets are utilized to compare the target configuration effects on the phase separation, morphology tuning, and their resulting physical properties, including optical and magnetic properties. This work suggests that the target configuration is another important parameter for achieving the desired VAN morphology and can be used to design different two-phase VANs with tailorable properties.

36 MATERIALS SCIENCE↗

Detecting light in whispering-gallery-mode resonators

An optical device including a whispering gallery mode (WGM) optical resonator configured to support one or more whispering gallery modes; and a photodetector optically coupled to an exterior surface of the optical resonator to receive evanescent light from the optical resonator to detect light inside the optical resonator.

Savchenkov, Anatoliy↗

Optical output enhances flowmeter accuracy

Magnetic flowmeter with a direct-coupled optical output increases accuracy and operates independently of other system inputs. The design includes simple external adjustment and signal amplitude control.

Wolpin, E. G.↗

Ring-laser gyroscope system using dispersive element(s)

A ring-laser gyroscope system includes a ring-laser gyroscope (RLG) and at least one dispersive element optically coupled to the RLG's ring-shaped optical path. Each dispersive element has a resonant frequency that is approximately equal to the RLG's lasing frequency. A group index of refraction defined collectively by the dispersive element(s) has (i) a real portion that is greater than zero and less than one, and (ii) an imaginary portion that is less than zero.

Smith, David D.↗