Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The effect of transient needle lift on the internal flow and near-nozzle spray characteristics for modern GDI systems investigated by high-speed X-ray imaging

The development of the injector nozzle is a dynamic area in regard of several technical aspects. At first, the internal flow influences the near-field spray characteristics via various phenomena such as cavitation and turbulence. However, these phenomena are not fully understood due to their extremely fast, complex and multiscale nature. Furthermore, it governs the spray targeting inside the combustion chamber. High-speed X-ray imaging of GDI injector nozzles is performed in this study. The experimental results presented are related to the internal flow and primary breakup of discharged liquid jets. The injectors used are equipped with nozzles made of aluminum which have been specially developed for these investigations to enhance optical accessibility. The visualization of the needle motion, in-nozzle flow and the primary breakup region provides several exciting observations. First, the needle lift tracking exhibits short overshooting right before the steady-state of the injection phase. Additionally, this event leads to a short-term, however, significant change in the associated performance of the breakup. This phenomenon is found to be a consequence of the transient behavior of the in-nozzle flow. It is shown that under some circumstances hydraulic flip may occur during this overshooting period. The primary jet breakup region is visualized and evaluated by means of image processing. Thus, the transient behavior of liquid jet expansion is quantified in the vicinity of the nozzle. It is observed that the liquid jet direction deviates from the hole axis already at the nozzle outlet, which is caused by internal flow characteristics.

42 ENGINEERING↗

Massively scalable Kerr comb-driven silicon photonic link

Abstract The growth of computing needs for artificial intelligence and machine learning is critically challenging data communications in today’s data-centre systems. Data movement, dominated by energy costs and limited ‘chip-escape’ bandwidth densities, is perhaps the singular factor determining the scalability of future systems. Using light to send information between compute nodes in such systems can dramatically increase the available bandwidth while simultaneously decreasing energy consumption. Through wavelength-division multiplexing with chip-based microresonator Kerr frequency combs, independent information channels can be encoded onto many distinct colours of light in the same optical fibre for massively parallel data transmission with low energy. Although previous high-bandwidth demonstrations have relied on benchtop equipment for filtering and modulating Kerr comb wavelength channels, data-centre interconnects require a compact on-chip form factor for these operations. Here we demonstrate a massively scalable chip-based silicon photonic data link using a Kerr comb source enabled by a new link architecture and experimentally show aggregate single-fibre data transmission of 512 Gb s −1 across 32 independent wavelength channels. The demonstrated architecture is fundamentally scalable to hundreds of wavelength channels, enabling massively parallel terabit-scale optical interconnects for future green hyperscale data centres.

Rizzo, Anthony (ORCID:000000034752797X)↗

Ultrafast optical modulation of vibrational strong coupling in ReCl(CO) 3 (2,2-bipyridine)

Polaritons – hybrid light-matter states formed from the strong coupling of a bright molecular transition with a confined photonic mode – may offer new opportunities for optical control of molecular behavior. Vibrational strong coupling (VSC) has been reported to impact ground-state chemical reactivity, but its influence on electronic excited-state dynamics remains unexplored. Here, we take a first step towards excited-state VSC by demonstrating optical modulation of the ReCl(CO) 3 (bpy), (bpy = 2,2-bipyridine) complex under VSC using femtosecond ultraviolet (UV)-pump/infrared (IR)-probe spectroscopy. We establish ground-state VSC of ReCl(CO) 3 (bpy) in a microfluidic Fabry-Pérot cavity equipped with indium tin oxide (ITO)-coated mirrors. ITO is effectively dichroic as it is reflective in the IR and transmissive in the UV-visible and therefore minimizes optical interference. Excitation with UV pump light drives ReCl(CO) 3 (bpy) into a manifold of electronic excited states that subsequently undergo non-radiative relaxation dynamics. We probe the transient response of the strongly-coupled system in the mid-IR, observing both Rabi contraction and cavity-filtered excited-state absorption signatures. We reconstruct the intrinsic response of intracavity molecules from the transient cavity transmission spectra to enable quantitative comparison with extracavity control experiments. We report no changes in the excited-state dynamics of ReCl(CO) 3 (bpy) under ground-state VSC. However, we do observe significant amplification of transient vibrational signals due to classical cavity-enhanced optical effects. This effort lays the groundwork to pursue direct excited-state VSC aimed at modulating photochemical reactivity.

cavity-enhanced spectroscopy↗

CSP Optical Facilities at the National Renewable Energy Laboratory

The concentrating Solar Power (CSP) Optical Facilities at NREL comprise unique optical tools and facilities for testing and characterizing concentrating solar optical components. These facilities are maintained to aid researchers and industry efforts to reduce market barriers, improve the performance, reduce the cost, and improve the lifetime and reliability of CSP materials, components, subsystems, and integrated concepts, where accurate and timely characterization methods are needed. To reach this goal, NREL is committed to collaborating in ongoing and projected research needs for industry, academia, and government entities, in the development and characterization of low-cost, high-performance reflector and absorber materials in addition to their components-a key element in the conversion of concentrated sunlight into energy. To accomplish this mission, the core laboratory includes the Advanced Optical Materials Laboratory, indoor and outdoor accelerated weather testing tools, "Distant Observer" for parabolic troughs, the High Flux Solar Furnace, and the ultra-accelerated weather testing tools. This equipment enables to rapidly respond to new challenges with novel solutions that align with the goals of the Solar Energy Technology Office (SETO) at the U.S. Department of Energy. The goal of this paper is to present the state-of art-optical facilities available at NREL that can help support the research needs of the CSP community. Therefore, we review here the different components of the CSP Optical Facilities at NREL and highlight their characteristics and importance for the CSP community.

accelerated weather testing↗

A confocal laser-induced fluorescence diagnostic with an annular laser beam

Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.

47 OTHER INSTRUMENTATION↗

Quantifying Twist Angles in Cuprate Heterostructures with Anisotropic Raman Signatures

Artificially engineered twisted van der Waals (vdW) heterostructures have unlocked new pathways for exploring emergent quantum phenomena and strongly correlated electronic states. Many of these phenomena are highly sensitive to the twist angle, which can be deliberately tuned to tailor the interlayer interactions. This makes the twist angle a critical tunable parameter, emphasizing the need for precise control and accurate characterization during device fabrication. In particular, twisted cuprate heterostructures based on Bi 2 Sr 2 CaCu 2 O 8 + x (BSCCO) have demonstrated angle-dependent superconducting properties, positioning the twist angle as a key tunable parameter. However, the twisted interface is highly unstable under ambient conditions and vulnerable to damage from conventional characterization tools such as electron microscopy or scanning probe techniques. In this work, a fully non-invasive, polarization-resolved Raman spectroscopy approach is introduced for determining twist angles in artificially stacked BSCCO heterostructures. By analyzing twist-dependent anisotropic vibrational Raman modes, particularly utilizing the out-of-plane A 1g vibrational mode of Bi/Sr at ≈116 cm −1 , clear optical fingerprints of the rotational misalignment between cuprate layers are identified. The high-resolution confocal Raman setup, equipped with polarization control and RayShield filtering down to 10 cm −1 , allows for reliable and reproducible measurements without compromising the material's structural integrity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unmanned Aerial Vehicle Path Generation for Image Collection to Assist Heliostat Field Optical Characterization

This paper focuses on applications of unmanned aerial vehicles (UAVs) for measuring optical error of heliostats in concentrating solar power (CSP) plants. In CSP, there is a need to measure solar-field optical errors, which is critical for future production improvement as well as for operations and maintenance of a heliostat field. This latter need is particularly challenging because of the large number of heliostats (over 10,000 for a utility-scale power plant) that individually track the sun in the field. To address this issue, a camera-equipped UAV, with an optimized drone flight path developed and uploaded to it, collects images of a precise reflection of the tower on each heliostat to evaluate optical error sources without interrupting plant operation. Generation of the drone path for capturing the reflected images is affected by a number technical and realistic constraints, which include the camera angle used to capture the image, the blocking of the camera view due to surrounding heliostats, the location of the camera in reference to the target heliostat, and the target heliostat position with reference to the tower. The effect of these constraints on calculating the camera position will be discussed in detail in this article. An effective drone-path algorithm is generated to fulfil the need of image collection under various constraints.

concentrated solar power↗

Geophysical monitoring using active seismic techniques at the Citronelle Alabama CO 2 storage demonstration site

Between August 2012 and September 2014, about 114,000 metric tonnes of CO 2 was captured from the coal-fired Plant Barry Power Station at Bucks Alabama and injected into the Paluxy Formation above the oil pool in the southeast unit of the Citronelle Oilfield. Various monitoring methods were deployed at land surface and in project wells to measure system performance, comply with permit requirements and test new and innovative monitoring tools. The monitoring program relied heavily on active seismic methods for subsurface imaging of geologic structure and time-lapse seismic techniques to track the CO 2 migration in the injection interval. Both conventional geophone/hydrophone and fiber-optic based Distributed Acoustic Sensing (DAS) arrays were deployed and tested, allowing a side by side comparison of the equipment and techniques. Geophysical imaging of the subsurface was successful using DAS in the offset vertical seismic profile (OVSP) survey configuration. A high resolution OVSP image of the subsurface was obtained in 2014 with DAS, which exceeded project expectations in comparison to a lower resolution image obtained in 2012 using a conventional 80-level geophone array. A time-lapse image of the redistribution of CO 2 after injection ended in September 2014 was obtained with two DAS OVSP surveys from June 2014 and December 2015, thus successfully demonstrating its proof-of-concept. Unfortunately, a pre-injection baseline survey with DAS, which was in its initial stage of technology development in 2012, did not have sufficient quality for use, making it difficult to interpret the acquired DAS time-lapse difference. Additional research in this area has since demonstrated the utility of time-lapse DAS OVSP. DAS data were also acquired during a cross-well seismic survey conducted in 2014. Unfortunately, the DAS technique was not success in the cross-well survey configuration because the system noise level was too high in the crosswell frequency output range (100–1200 Hz) of the piezoelectric source (increasing by a factor of ten compared to VSP frequency band). Additionally, the cross-well geometry causes sub-horizontal (broadside) incidence on the vertical DAS fiber cable, which is known to be problematic. Current research is focused on improving the DAS cable response to broadside acoustic energy. Time-lapse seismic surveys using commercially available conventional arrays were also acquired. In contrast to the DAS acquired data, the cross-well seismic results obtained with the conventional array was highly successful and clearly showed the CO 2 remained in zone at the end of injection. Time-lapse differencing of the OSVP surveys acquired with the conventional arrays proved to be inconclusive. Finally, changes in wellbore conditions between surveys and unavoidable changes in equipment (the array used for the baseline survey was retired) affected data quality, making it difficult to interpret the OVSP results.

58 GEOSCIENCES↗

A physically unclonable function using NV diamond magnetometry and micromagnet arrays

A physically unclonable function (PUF) is an embedded hardware security measure that provides protection against counterfeiting. In this article, we present our work on using an array of randomly magnetized micrometer-sized ferromagnetic bars (micromagnets) as a PUF. We employ a 4μm thick surface layer of nitrogen-vacancy (NV) centers in diamond to image the magnetic field from each micromagnet in the array, after which we extract the magnetic polarity of each micromagnet using image analysis techniques. Finally, after evaluating the randomness of the micromagnet array PUF and the sensitivity of the NV readout, we conclude by discussing the possible future enhancements for improved security and magnetic readout.

Electromagnetism↗

Smartphone-Based Device for Colorimetric Detection of MicroRNA Biomarkers Using Nanoparticle-Based Assay

The detection of microRNAs (miRNAs) is emerging as a clinically important tool for the non-invasive detection of a wide variety of diseases ranging from cancers and cardiovascular illnesses to infectious diseases. Over the years, miRNA detection schemes have become accessible to clinicians, but they still require sophisticated and bulky laboratory equipment and trained personnel to operate. The exceptional computing ability and ease of use of modern smartphones coupled with fieldable optical detection technologies can provide a useful and portable alternative to these laboratory systems. Herein, we present the development of a smartphone-based device called Krometriks, which is capable of simple and rapid colorimetric detection of microRNA (miRNAs) using a nanoparticle-based assay. The device consists of a smartphone, a 3D printed accessory, and a custom-built dedicated mobile app. We illustrate the utility of Krometriks for the detection of an important miRNA disease biomarker, miR-21, using a nanoplasmonics-based assay developed by our group. We show that Krometriks can detect miRNA down to nanomolar concentrations with detection results comparable to a laboratory-based benchtop spectrophotometer. With slight changes to the accessory design, Krometriks can be made compatible with different types of smartphone models and specifications. Thus, the Krometriks device offers a practical colorimetric platform that has the potential to provide accessible and affordable miRNA diagnostics for point-of-care and field applications in low-resource settings.

Krishnan, Tushar (ORCID:0000000342610336)↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Horizontal Splitter Design For FFA@CEBAF Energy Upgrade: Current Status

Thomas Jefferson National Accelerator Facility (Jefferson Lab) is currently studying the feasibility of an energy upgrade based upon Fixed-Field Alternating Gradient (FFA) permanent magnet technology. The current plan is to replace the highest-energy recirculation arcs with FFA arcs, increasing the total number of beam recirculations, thus the energy. In order to accommodate multiple passes in the FFA arcs, horizontal splitters are being designed to control the beam parameters entering the FFA arcs, as well as the time of flight and R_56. In the current design, six passes will recirculate through the FFA arcs, necessitating the design of six independent beamlines to control the optics and beam dynamics matching into the arcs. These beamlines must fit into the current CEBAF tunnel, while allowing for personnel and equipment access. They must also be flexible enough to accommodate the beam under realistic operational conditions and fluctuations. The constraints on the system are highly restrictive, complicating the design. This document will describe the current state of the design, and indicate the work remaining for a complete conceptual design.

Benesch, Jay↗

Glass Components Fabricated via Aerosol Jet Printing

Micron-scale glass components are widely used in optical, photonic, and microfabricated systems. These components are commonly produced through grinding, polishing, and milling processes that require tight tolerances and specialized equipment. As device architectures become more compact and geometrically complex, these approaches can constrain design flexibility and integration. Los Alamos researchers developed an additive manufacturing process that builds glass components layer by layer using aerosol jet printing. Glass particles suspended in an aerosolizable carrier solution are deposited onto a substrate and then sintered to form monolithic glass structures. This approach enables controlled fabrication of small glass features without bulk glass melting or post-fabrication machining.

36 MATERIALS SCIENCE↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Partially cracked ammonia mixture combustion in gas turbine combustors

Ammonia is gaining popularity for single fuel use in existing gas turbines, as it is carbonless, has higher hydrogen content per unit volume than liquid hydrogen, and facilitates easy storage and handling. However, the low flame speed of ammonia makes it prone to flame blow off and remains the chief concern for its use in power generation. Following previous studies that have shown improved combustion performance by partially cracking the fuel, in this computational study, efficacy of partially cracked ammonia as a replacement fuel for natural gas is evaluated. A high-pressure optically accessible combustor operated at ~10 bar pressure with non-vitiated heated air was used as the test platform. This combustor was equipped with a novel multifuel multi-tube micromixing injector (M3 injector). High resolution simulations of the flow fields both in the injector as well as the combustor were performed to understand the fuel mixing in the injector and in the inlet region of the combustor. These modeling results showed that the injector was highly effective for achieving mixture homogeneity at the entrance of the combustor for ammonia and natural gas injection, whereas, for hydrogen an earlier injection facilitating longer residence time would be beneficial. Also, these simulations show that while harnessing waste heat the ideal fuel dissociation fraction is between 0.4 and 0.55 for optimal operation.

Ammonia↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗