Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL HETERODYNE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A symmetrical laser Doppler velocity meter and its application to turbulence characterization

A symmetrical method of optical heterodyning of the Doppler shifted scattered laser radiation developed for velocity measurements with a minimal instrumental spectral broadening and a high signal-to-noise ratio. The method employs two laser beams incident on the moving scatterer and does not use any reference beam for heterodyning. The Doppler signal frequency is independent of the scattering angle and the signal possesses no receiving aperture broadening. Optical alignment is simple. Typical values of the instrumental spectral broadening were approximately 0.8 percent of the center frequency of the Doppler signal, and the signal-to-noise ratio was approximately 25 dB, obtained from an air flow system using submicron dioctylphthalate scattering aerosol. Experimental and theoretical studies were made on the characteristics of the Doppler signal and the effect of system parameters in turbulent flow measurement. The optimization process involved in the beam optics and in the use of a spatial filter is described. For localized flow measurement in any direction of the three-dimensional orthogonal coordinates, the system, using uncorrected optical components, had a sensing volume which can be described by a sensitive length of 600 microns and a diameter of 100 microns.

Mazumder, M. K.↗

Gregorian all-reflective optical system

An optical heterodyne receiver comprises a system of reflectors forming a folded Gregorian configuration for collecting a signal beam, and an optical detector located at the focus of the system. A paraboloidal primary reflector and an elipsoidal secondary reflector face each other on an optical axis with the focus of the secondary reflector coinciding with the focus of the primary reflector. An auxiliary laser generates a local oscillator beam that is combined with the signal beam after the signal beam emerges from the exit pupil (which is also the aperture stop) of the system, and the resultant is impinged on the detector. A pair of image motion compensators is located as close to the exit pupil as possible for aligning off-axis inputs to the detector.

King, W. L.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

Interferometer for Measuring Displacement to Within 20 pm

An optical heterodyne interferometer that can be used to measure linear displacements with an error <=20 pm has been developed. The remarkable accuracy of this interferometer is achieved through a design that includes (1) a wavefront split that reduces (relative to amplitude splits used in other interferometers) self interference and (2) a common-optical-path configuration that affords common-mode cancellation of the interference effects of thermal-expansion changes in optical-path lengths. The most popular method of displacement- measuring interferometry involves two beams, the polarizations of which are meant to be kept orthogonal upstream of the final interference location, where the difference between the phases of the two beams is measured. Polarization leakages (deviations from the desired perfect orthogonality) contaminate the phase measurement with periodic nonlinear errors. In commercial interferometers, these phase-measurement errors result in displacement errors in the approximate range of 1 to 10 nm. Moreover, because prior interferometers lack compensation for thermal-expansion changes in optical-path lengths, they are subject to additional displacement errors characterized by a temperature sensitivity of about 100 nm/K. Because the present interferometer does not utilize polarization in the separation and combination of the two interfering beams and because of the common-mode cancellation of thermal-expansion effects, the periodic nonlinear errors and the sensitivity to temperature changes are much smaller than in other interferometers

Zhao, Feng↗

Dynamic Strength of Copper at High Pressures Using Pressure Shear Plate Experiments

Measurement of strength at high pressures is critical to understanding the behavior of materials subjected to extreme loading conditions. Recent developments have extended the pressure shear plate impact (PSPI) technique to the high-pressure regime. Such experiments provide a unique opportunity to extract the complete stress-strain behavior of materials at relatively high pressures. The modified technique includes a new fiber-optic heterodyne transverse velocity interferometer system and new analysis methods to account for the inelastic response of the anvil plates. In this study, PSPI experiments are conducted on oxygen-free high conductivity (OFHC) copper at pressures ranging from 10 to 43 GPa and at strain rates of ~10 5 s -1 . Complete stress-strain curves of copper are obtained using a hybrid methodology that relies on numerical simulations and particle velocity records gathered in these experiments. Experiments are conducted at similar pressures and strain rates using two types of anvils that undergo different levels of plastic strains: tool steel and tungsten carbide, to check the robustness of the hybrid method. The behavior of copper at these high pressures and strain rates is compared with previous literature data, and the effect of pressure and strain rate on the strength behavior of copper are discussed. Here, it was observed that the rate of change in yield strength change in pressure was 2.5 times the rate of change of shear modulus with pressure. The strength models that predict the response of copper at these extreme conditions are also examined and validated.

36 MATERIALS SCIENCE↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Laser vibration analyzer

Instrument system uses laser and optical heterodyne receiver to measure Doppler phase shifts produced on a laser beam by the deflection of the vibrating surface of a structure under test or in operation.

Foster, J. V.↗

Modulation and detection of optical signals

A summary of information is presented which is related to the modulation and detection of information on optical carriers. It emphasizes the treatment of information transfer through an entire system. The most common configurations are considered: intensity modulation, amplitude modulation, frequency or phase modulation, and both direct and coherent detection. In assessing these configurations information capacity and message signal-to-noise ratio are used as a basis of comparison. The physical and geometric treatment of optical heterodyne (or coherent) detection is given.

Goodwin, F. E.↗

Laser communication experiment. Volume 1: Design study report: Spacecraft transceiver. Part 3: LCE design specifications

The requirements for the design, fabrication, performance, and testing of a 10.6 micron optical heterodyne receiver subsystem for use in a laser communication system are presented. The receiver subsystem, as a part of the laser communication experiment operates in the ATS 6 satellite and in a transportable ground station establishing two-way laser communications between the spacecraft and the transportable ground station. The conditions under which environmental tests are conducted are reported.

Source record↗

HgCdTe photodiodes for CO2 laser systems

A recently developed long-wave infrared detector, the photovoltaic HgCdTe, has many advantages which may solve some of the system problems that have impeded the development of carbon dioxide systems. The detectors are available for operation in the temperature range from 77 K to 146 K. Noise problems inherent in a number of conventional detection techniques can be overcome by a suitably implemented optical heterodyne method. Aspects of heterodyne detector development are discussed along with questions concerning the HgCdTe photodiodes which are available.

Koehler, T.↗

Laser Doppler spectrometer method of particle sizing

A spectrometer for the detection of airborne particulate pollution in the submicron size range is described. In this device, airborne particles are accelerated through a supersonic nozzle, with different sizes achieving different velocities in the gas flow. Information about the velocities of the accelerated particles is obtained with a laser-heterodyne optical system through the Doppler shift of light scattered from the particles. Detection is accomplished by means of a photomultiplier. Nozzle design and signal processing techniques are also discussed.

Weber, F. N.↗

Single-tone and two-tone AM-FM spectral calculations for tunable diode laser absorption spectroscopy

A generalized theory for optical heterodyne spectroscopy with phase modulated laser radiation is used which allows the calculation of signal line shapes for frequency modulation spectroscopy of Lorentzian gas absorption lines. In particular, synthetic spectral line shapes for both single-tone and two-tone modulation of lead-salt diode lasers are presented in which the contributions from both amplitude and frequency modulations are included.

Chou, Nee-Yin↗