Search NASA⌕ Search

SEARCH · Search NASA

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Minimizing Variation in Outdoor CPV Power Ratings (Presentation)

Presented at the 7th International Conference on Concentrating Photovoltaic Systems (CPV-7), 4-6 April 2011, Las Vegas, Nevada. The CPV community has agreed to have both indoor and outdoor power ratings at the module level. The indoor rating provides a repeatable measure of module performance as it leaves the factory line while the outdoor rating provides a measure of true performance under realworld conditions. The challenge with an outdoor rating is that the spectrum, temperature, wind speed, etc are constantly in flux and therefore the resulting power rating varies from day to day and month to month. This work examines different methodologies for determining the outdoor power rating with the goal of minimizing variation even if data are collected under changing meteorologicalconditions.

14 SOLAR ENERGY↗

Outdoor and indoor air quality and cognitive ability in young children

Highlights: • Outdoor and indoor air quality and cognitive ability in early childhood is explored. • Long-term but not short-term effects of outdoor NO{sub 2} on verbal ability at age 3 found. • Exposure to indoor damp or condensation predicted lower cognitive ability at age 3. • Secondhand smoke exposure associated with lower cognitive ability at age 3. This study examined outdoor and indoor air quality at ages 9 months and 3 years and their association with cognitive ability at age 3 in England and Wales.

54 ENVIRONMENTAL SCIENCES↗

Outdoor performance of a tandem InGaP/Si photovoltaic luminescent solar concentrator

Here, we report the design, fabrication and outdoor characterization of a tandem luminescent solar concentrator/Si multi-junction photovoltaic module. Our tandem LSC/Si device consists of an InGaP LSC functioning as a top cell and a passivated contact Si bottom cell. The LSC comprises of an InGaP microcell array coupled to a polymer waveguide, loaded with CdSe/CdS core-shell quantum dot luminophores. The light trapping efficiency of the LSC waveguide is enhanced by encapsulation with photoluminescence trapping mirrors consisting of dielectric multilayer thin films. We demonstrate the performance of the LSC/Si device through a series of outdoor tests under various irradiance conditions conducted at the National Renewable Energy Laboratory. We report the first outdoor testing data of an LSC/Si tandem module, displaying maintained performance across varied diffusivity conditions for the LSC component. Finally, we model the tandem module performance using a ray optic simulation-based multiphysics model and forecast a pathway for high efficiency tandem LSC/Si module performance.

14 SOLAR ENERGY↗

PV Reference Cells for Outdoor Use: An Investigation of Calibration Factors

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as a low-cost alternative to thermopile radiometers. But reference cell characteristics differ substantially from the latter, therefore measurements made by one category of instrument cannot be substituted for or directly compared with the other. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of 39 units of 10 distinct types made by 6 manufacturers. This report compares the calibration factors provided by manufacturers - which most users rely upon - to those measured at a high level of accuracy by NREL's Cell Lab. It also reports on the application of the Broadband Outdoor Radiometer Calibration (BORCAL) method to reference cells. As a group, the factory calibrations for the crystalline silicon cells showed a small positive bias of +0.7%, with a tight distribution around this value. This is a very good result for the manufacturers. The two World Photovoltaic Scale cells constituted outliers, with a mean deviation of -0.8%, which is still within the reported uncertainty ranges. The data collected during the BORCAL procedures show a strong and systematic fluctuation of the apparent responsivity of the reference cells over the course of a day, which was anticipated. Consequently, the standard BORCAL R@45 calibration factors underestimated the reference cell responsivities by 1%-4%. An alternate responsivity indicator was developed, R'@30, incorporating adjustments for temperature response, spectral response, and directional response. This reduced the mean deviation to -0.4% compared to the Cell Lab. Further, two independent BORCAL sessions were able to produce the same values to within ±0.2%. This could be a viable approach for verifying reference cells using existing BORCAL infrastructure, for example, to evaluate their long-term stability. The daily profiles of responsivity obtained during the BORCAL sessions (provided in Appendix A) show clear patterns of differences between models, which provides evidence that their directional responses differ from each other; thus, two sensors that are calibrated correctly might give the same reading at 30° zenith angle but systematically different readings at 60°. The impact of these inconsistencies in field operation will be quantified using the long-term observations started in 2020.

14 SOLAR ENERGY↗

A preliminary implementation of metabolic-based pH control to reduce CO 2 usage in outdoor flat-panel photobioreactor cultivation of Nannochloropsis oceanica microalgae

A crucial challenge associated with high-density, commercial-scale, outdoor microalgal cultivation is maintaining pH stability without excessive use of CO 2 buffering. This includes a media-dependent, intracellular metabolic proton imbalance leading to the alkalization or acidification of growth media that results when algae consume, respectively, nitrate or ammonium ions. Feeding these two nitrogen sources can theoretically achieve balanced proton metabolism as well as pH control that is economically more favorable as compared to CO 2 buffering or acid/base addition. To accomplish this, a fed-batch nutrient feeding strategy must be adopted as a component of a model-based pH control system, particularly in the case of ammonium preference. This work represents a preliminary study of the challenges of implementing a nitrogen metabolism based open-loop pH control strategy in the challenging environment of an outdoor photobioreactor at the DOE-ATP 3 testbed facility in Mesa, Arizona during the high solar insolation period of summer 2015. The approach was limited to twice daily fed-batch addition while accounting for ammonium-N preference in a background of nitrate-based algae growth media. Despite these limitations, growth achieved for a photobioreactor operated based on predicted metabolic nitrogen demand (PND) was comparable to ‘CO 2 -on-demand’ (CoD) for pH control. PND reduced CO 2 usage to b10% of CoD control, where the reduced buffering resulted in much greater pH fluctuations due to daily variations in light availability, and a much lower and more consistent media alkalinity (5.73–5.79 mEq/L) as compared to the CoD control (6.51–8.49 mEq/L). While this effort illustrates the utility of feed-forward model-based control, it further illustrates the need for far more sophisticated ‘real time’ monitoring and modeling to accommodate the dynamic outdoor conditions. In conclusion, a need for improved analytics for accurate closure of nitrogen mass balance is also indicated.

09 BIOMASS FUELS↗

Characterization of fine particulate matter in Ohio: Indoor, outdoor, and personal exposures

Ambient, indoor, and personal PM{sub 2.5} concentrations were assessed based on an exhaustive study of PM{sub 2.5} performed in Ohio from 1999 to 2000. Locations in Columbus, one in an urban corridor and the other in a suburban area were involved. A third rural location in Athens, Ohio, was also established. At all three locations, elementary schools were utilized to determine outdoor, indoor, and personal PM{sub 2.5} concentrations for fourth and fifth grade students using filter-based measurements. Three groups of 30 students each were used for personal sampling at each school. Continuous ambient PM{sub 2.5} mass concentrations were also measured with tapered element oscillating microbalances (TEOMs). At all three sites, personal and indoor PM{sub 2.5} concentrations exceeded outdoor levels. This trend is consistent on all week days and most evident in the spring as compared to fall and winter. The ambient PM{sub 2.5} concentrations were similar among the three sites, suggesting the existence of a common regional source influence. At all the three sites, larger variations were found in personal and indoor PM{sub 2.5} than ambient levels. The strongest correlations were found between indoor and personal concentrations, indicating that personal PM{sub 2.5} exposures were significantly affected by indoor PM{sub 2.5} than by ambient PM{sub 2.5}. This was further confirmed by the indoor to outdoor (I/O) ratios of PM{sub 2.5} concentrations, which were greater when school was in session than non-school days when the students were absent.

54 ENVIRONMENTAL SCIENCES↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Picochlorum celeri as a model system for robust outdoor algal growth in seawater

Abstract With fast growth rates, broad halotolerance and the ability to thrive at high temperatures, algae in the genus Picochlorum are emerging as promising biomass producers. Recently, we isolated a remarkably productive strain, Picochlorum celeri , that attains > 40 g m −2 day −1 productivities using simulated outdoor light. To test outdoor productivities, Picochlorum celeri was cultivated in 820 L raceway ponds at the Arizona Center for Algae Technology and Innovation. Picochlorum celeri demonstrated the highest outdoor biomass productivities reported to date at this testbed averaging ~ 31 g m −2 day −1 over four months with a monthly (August) high of ~ 36 g m −2 day −1 . Several single day productivities were > 40 g m −2 day −1 . Importantly for sustainability, Picochlorum celeri achieved these productivities in saline water ranging from seawater to 50 parts per thousand sea salts, without any biocides or pond crashes, for over 143 days. Lastly, we report robust genetic engineering tools for future strain improvements.

59 BASIC BIOLOGICAL SCIENCES↗

A bloom of a single bacterium shapes the microbiome during outdoor diatom cultivation collapse

Algae-dominated ecosystems are fundamentally influenced by their microbiome. We lack information on the identity and function of bacteria that specialize in consuming algal-derived dissolved organic matter in high algal density ecosystems such as outdoor algal ponds used for biofuel production. Here, we describe the metagenomic and metaproteomic signatures of a single bacterial strain that bloomed during a population-wide crash of the diatom, Phaeodactylum tricornutum, grown in outdoor ponds. 16S rRNA gene data indicated that a single Kordia sp. strain (family Flavobacteriaceae) contributed up to 93% of the bacterial community during P. tricornutum demise. Kordia sp. expressed proteins linked to microbial antagonism and biopolymer breakdown, which likely contributed to its dominance over other microbial taxa during diatom demise. Analysis of accompanying downstream microbiota (primarily of the Rhodobacteraceae family) provided evidence that cross-feeding may be a pathway supporting microbial diversity during diatom demise. In situ and laboratory data with a different strain suggested that Kordia was a primary degrader of biopolymers during algal demise, and co-occurring Rhodobacteraceae exploited degradation molecules for carbon. An analysis of 30 Rhodobacteraceae metagenome assembled genomes suggested that algal pond Rhodobacteraceae commonly harbored pathways to use diverse carbon and energy sources, including carbon monoxide, which may have contributed to the prevalence of this taxonomic group within the ponds. These observations further constrain the roles of functionally distinct heterotrophic bacteria in algal microbiomes, demonstrating how a single dominant bacterium, specialized in processing senescing or dead algal biomass, shapes the microbial community of outdoor algal biofuel ponds.

Kordia↗

Development of an Outdoor Temperature-Based Control Algorithm for Residential Mechanical Ventilation Control

Smart ventilation systems use controls to ventilate more during those periods that provide either an energy or IAQ advantage (or both) and less during periods that provide a dis advantage. Using detailed building simulations, this study addresses one of the simplest and lowest cost types of smart controllers —outdoor temperature- based control. If the outdoor temperature falls below a certain cut- off, the fan is simply turned off. T he main principle of smart ventilation used in this study is to shift ventilation from time periods with large indoor -outdoor temperature differences, to periods where these differences are smaller, and their energy impacts are expected to be less. Energy and IAQ performance are assessed relative to a base case of a continuously operated ventilation fan sized to comply with ASHRAE 62.2-2013 whole house ventilation requirements. In order to satisfy 62.2-2013, annual pollutant exposure must be equivalent between the temperature controlled and continuous fan cases. This requires ventilation to be greater than 62.2 requirements when the ventilation system operates. This is achieved by increasing the mechanical ventilation system air flow rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Outdoor Air Emissions, Land Use, and Land Cover around Schools on Tribal Lands

Children from tribes are more burdened with adverse respiratory well-being outcomes versus other U.S. children. The objectives of this study were to identify stressors from the built and natural environments for tribal school-aged children. Outdoor air concentrations around U.S. tribal schools were linked to National Emission Inventories; ecoregions and National Land Cover Database; and American Community Survey and school map layers. Nine school sites (seven tribes, five U.S. states) were in three ecoregions: North American Deserts, Northern Forests, and Mediterranean California. Closest emission sources were oil, gas, airport, and manufacturing facilities. Maximum annual outdoor air concentrations were measured for toluene at two schools (29 ppb and 15 ppb, 2011), located four miles from a solid waste landfill and eight miles from paperboard/saw mills. Maximum annual concentrations of metals in particulate matter 10 micrometers and smaller were highest for manganese (68 ng/m3, 2011). Schools were in mainly arid and heavily forested lands. Closest emission sources were predominantly off tribal lands. Measurements were limited (<30/year). Compared to schools off tribal lands, schools on tribal lands were further away from roadway sources. Future research may examine outdoor air quality around schools with more developed land and indoor air for tribal children’s total exposure.

54 ENVIRONMENTAL SCIENCES↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Effect of field of view and monocular viewing on angular size judgements in an outdoor scene

Observers typically overestimate the angular size of distant objects. Significantly, overestimations are greater in outdoor settings than in aircraft visual-scene simulators. The effect of field of view and monocular and binocular viewing conditions on angular size estimation in an outdoor field was examined. Subjects adjusted the size of a variable triangle to match the angular size of a standard triangle set at three greater distances. Goggles were used to vary the field of view from 11.5 deg to 90 deg for both monocular and binocular viewing. In addition, an unrestricted monocular and binocular viewing condition was used. It is concluded that neither restricted fields of view similar to those present in visual simulators nor the restriction of monocular viewing causes a significant loss in depth perception in outdoor settings. Thus, neither factor should significantly affect the depth realism of visual simulators.

Denz, E. A.↗

Outdoor and laboratory testing of photovoltaic modules

An overview of outdoor and laboratory testing being applied to terrestrial photovoltaic modules is presented. Descriptions of the test procedures, examples of results, and discussion of the advantages and shortcomings of each approach are included. The test program consists of real-time outdoor testing of systems, modules and materials, and accelerated outdoor testing and laboratory testing of modules. The test results suggest that the various types of tests complement each other and contribute toward the objective of verifying the environmental suitability of the product. A description of representative photovoltaic systems operational in the U.S. in 1981 is presented, along with an identification, description, and physical inspection summary of JPL test module sites and a summary of degradation and failure data for the modules.

Hoffman, A.↗

Human Response to Low-Intensity Sonic Booms Heard Indoors and Outdoors

Test subjects seated inside and outside a house were exposed to low-intensity N-wave sonic booms during a 3-week test period in June 2006- The house was instrumented to measure the booms both inside and out. F-18 aircraft were flown to achieve a variety of boom overpressures from approximately .1 to .6 psf During four test days, seventy-seven test subjects heard the booms while seated inside and outside the house. Using the Magnitude Estimation methodology and artificial reference sounds ; the subjects rated the annoyance of the booms. Since the same subjects heard similar booms both inside and outside the house, comparative ratings of indoor and outdoor annoyance were obtained. For a given metric level, indoor subjects gave higher annoyance scores than outdoor subjects. For a given boom; annoyance scores inside were on average the same as those outside. In a post-test questionnaire, the majority of subjects rated the indoor booms as more annoying than the outdoor ones. These results are discussed in this paper.

Sullivan, Brenda M.↗

Comparing Two Weather-Robust Microphone Configurations for Outdoor Measurements

This paper discusses comparisons made between two ground-based outdoor microphone configurations. The first is known as the Compact Outdoor Unit for Ground-based Acoustical Recordings (COUGAR) and consists of an inverted microphone placed above a convex circular plate and covered by a large dome windscreen. The second configuration is the COUGARxt, where the “xt” simultaneously refers to an extra thick windscreen and an extra thin ground plate. COUGAR and COUGARxt were subjected to laboratory testing where their responses to sound were recorded at several different elevation and azimuthal angles. At almost all shown elevation angles, both configurations recorded levels that were within ±3 dB of a baseline measurement between 50 Hz – 20 kHz. At all shown azimuthal angles and over the same frequency range, both recorded levels within ±2 dB of the levels reported at an azimuthal angle of 0°, with COUGARxt having less variation than COUGAR. The configurations were also subjected to wind noise testing, where COUGARxt demonstrated superior wind noise rejection at low frequencies. The conclusion is that both configurations are suitable for outdoor acoustical measurements and that COUGARxt is the superior configuration, especially when measuring low-frequency noise.

sonic boom↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 w/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 w/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky night monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs and CG4 was calculated using NREL equation. The calculated uncertainty (U95) of the PIRs varied from 2.43 w/m2 to 2.67 w/m2 , and for the CG4 equals 1.97 w/m2 with respect to SI.

absolute cavity pyrgeometer↗