Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational adaptability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Adaptive strategies of remote systems operators exposed to perturbed camera-viewing conditions

This report describes a preliminary investigation of the use of perturbed visual feedback during the performance of simulated space-based remote manipulation tasks. The primary objective of this NASA evaluation was to determine to what extent operators exhibit adaptive strategies which allow them to perform these specific types of remote manipulation tasks more efficiently while exposed to perturbed visual feedback. A secondary objective of this evaluation was to establish a set of preliminary guidelines for enhancing remote manipulation performance and reducing the adverse effects. These objectives were accomplished by studying the remote manipulator performance of test subjects exposed to various perturbed camera-viewing conditions while performing a simulated space-based remote manipulation task. Statistical analysis of performance and subjective data revealed that remote manipulation performance was adversely affected by the use of perturbed visual feedback and performance tended to improve with successive trials in most perturbed viewing conditions.

Stuart, Mark A.↗

Operations for Learning with Graphical Models

This paper is a multidisciplinary review of empirical, statistical learning from a graphical model perspective. Well-known examples of graphical models include Bayesian net- works, directed graphs representing a Markov chain, and undirected networks representing a Markov field. These graphical models are extended to model data analysis and empirical learning using the notation of plates. Graphical operations for simplifying and manipulating a problem are provided including decomposition, differentiation, and the manipulation of probability models from the exponential family. These operations adapt existing techniques from statistics and automatic differentiation to graphs. Two standard algorithm schemes for learning are reviewed in a graphical framework: Gibbs sampling and the expectation maximization algorithm. Some algorithms are developed in this graphical framework including a generalized version of linear regression, techniques for feed-forward networks, and learning Gaussian and discrete Bayesian networks from data. The paper concludes by sketching some implications for data analysis and summarizing some popular algorithms that fall within the framework presented. The main original contributions here are the decomposition techniques and the demonstration that graphical models provide a framework for understanding and developing complex learning algorithms.

Buntine, Wray L.↗

Response properties of pigeon otolith afferents to linear acceleration

In the present study, the sensitivity to sinusoidal linear accelerations in the plane of the utricular macula was tested in afferents. The head orientation relative to the translation axis was varied in order to determine the head position that elicited the maximal and minimal responses for each afferent. The response gain and phase values obtained to 0.5-Hz and 2-Hz linear acceleration stimuli were then plotted as a function of head orientation and a modified cosine function was fit to the data. From the best-fit cosine function, the predicted head orientations that would produce the maximal and minimal response gains were estimated. The estimated maximum response gains to linear acceleration in the utricular plane for the afferents varied between 75 and 1420 spikes s-1 g-1. The mean maximal gains for all afferents to 0.5-Hz and 2-Hz sinusoidal linear acceleration stimuli were 282 and 367 spikes s-1 g-1, respectively. The minimal response gains were essentially zero for most units. The response phases always led linear acceleration and remained constant for each afferent, regardless of head orientation. These response characteristics indicate that otolith afferents are cosine tuned and behave as one-dimensional linear accelerometers. The directions of maximal sensitivity to linear acceleration for the afferents varied throughout the plane of the utricle; however, most vectors were directed out of the opposite ear near the interaural axis. The response dynamics of the afferents were tested using stimulus frequencies ranging between 0.25 Hz and 10 Hz (0.1 g peak acceleration). Across stimulus frequencies, most afferents had increasing gains and constant phase values. These dynamic properties for individual afferents were fit with a simple transfer function that included three parameters: a mechanical time constant, a gain constant, and a fractional order distributed adaptation operator.

Non-NASA Center↗

Preliminary Modeling of CH3D From 4000 to 4550 cm (exp-1)

A new study of 12CH3D line positions and intensities was performed for the upper portion of the Enneadecad polyad between 4000 and 4550/cm. For this, FTIR spectra were recorded with D-enriched methane samples (at 80 K with a Bruker 125 IFS at 0.005/cm resolution and at 291 K with the McMath-Pierce FTS at 0.011/cm resolution, respectively). Line positions and intensities were retrieved by least square curve-fitting procedures and analyzed using the effective Hamiltonian and the effective dipole moment expressed in terms of irreducible tensor operators adapted to symmetric top molecules. Initially, only the cold spectrum was used to identify quantum assignments and predict 12CH3D relative intensities in this region. To assign higher quanta up to J equal 14, additional line positions and intensities were obtained from two room temperature spectra. In the final stage, measured intensities from both the cold and the room temperature data were normalized to corresponding values at 296 K and then averaged. Combining the two temperature datasets confirmed the assumed quantum assignments and also demonstrated the relative accuracies to be better than 70.0002/cm for line positions and at least +/-6% for intensities so that approx.1160 features were selected. Including additional assignments from the room temperature spectra alone permitted 1362 line intensities of 11 bands (involving 23 vibrational symmetry components) to be reproduced with an RMS of 9%. Over 4085 selected positions for 12 bands were modeled to 0.008/cm. Nevertheless a number of known assignments could not be modeled to within our experimental precisions. More work is needed to obtain a complete characterization of this complex polyad.

Nikitin, A. V.↗

Large-Scale Implementation of Recirculation Systems for In-Situ Treatment of Hexavalent Chromium in Groundwater in Hinkley CA - 17338

In-situ remediation using recirculation systems is being used to treat hexavalent chromium (Cr[VI]) in groundwater within the plume core at the Pacific Gas and Electric Company Hinkley Compressor Station in Hinkley, California (the Site). In-situ Reactive Zones (IRZs) are currently treating an area of 0.8 kilometers (km, one-half of a mile) by 1.6 km (a mile) to target treatment of the core of the Cr(VI) plume, where concentrations of Cr(VI) range from 10 s of micrograms per liter (μg/L) to several milligrams per liter (mg/L). Following pilot testing from 2004-2006, large scale implementation of in-situ remediation began in late 2007 and has been on-going. Implementation of the recirculation systems has been successful in remediating Cr(VI) in groundwater at a large scale. Through Third Quarter 2015, in-situ remediation had removed over 44 percent of the mass in the target treatment area. Within the IRZs, concentrations are rapidly reduced within the timeframe of weeks to a few months. Down-gradient of the IRZs, treatment has been observed at distances over 915 meters (3,000 feet). This presentation will focus on the design, operation, adaptive management and results of this effort. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of adaptive automation on operator-system performance - 103

Adaptive automation (AA) is the dynamic, real-time change in the degree of automation in response to situational changes. AA systems are being developed in many industries, including for nuclear power plant applications. AA is a promising means of mitigating human performance issues that often arise in highly automated systems. The purpose of this Nuclear Regulatory Commission study was to characterize important AA design features, define the effects of AA on performance, examine the human factors engineering (HFE) guidance available to design and evaluate AA systems, and identify research and development needs. In general, we found that AA improves task performance and situation awareness (SA) while managing workload. Although the research is limited, AA also supports operator recognition of automation failure and recovery. Research on human-system interfaces has identified principles showing promise for supporting SA, including failure detection, and limiting workload. Research further suggests that AA systems are both more effective, and less disruptive and distracting, when they follow rules of interaction similar to those used by human crewmembers. Our general conclusion about the HFE guidance available to designers and reviewers is that it is limited and has not kept pace with automation technology. We discuss several research and development needs that will help support a better understanding of where and how AA should be used and support the development of more comprehensive guidance for AA safety reviews. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Split representation of adaptively compressed polarizability operator

The polarizability operator plays a central role in density functional perturbation theory and other perturbative treatment of first principle electronic structure theories. The cost of computing the polarizability operator generally scales as O(Ne4) where Ne is the number of electrons in the system. The recently developed adaptively compressed polarizability operator (ACP) formulation [L. Lin, Z. Xu and L. Ying, Multiscale Model. Simul. 2017] reduces such complexity to O(Ne 3 ) in the context of phonon calculations with a large basis set for the first time, and demonstrates its effectiveness for model problems. In this paper, we improve the performance of the ACP formulation by splitting the polarizability into a near singular component that is statically compressed, and a smooth component that is adaptively compressed. The new split representation maintains the O(Ne 3 ) complexity, and accelerates nearly all components of the ACP formulation, including Chebyshev interpolation of energy levels, iterative solution of Sternheimer equations, and convergence of the Dyson equations. For simulation of real materials, we discuss how to incorporate nonlocal pseudopotentials and finite temperature effects. In this work, we demonstrate the effectiveness of our method using one-dimensional model problem in insulating and metallic regimes, as well as its accuracy for real molecules and solids.

97 MATHEMATICS AND COMPUTING↗

Symmetry dilemmas in quantum computing for chemistry: A comprehensive analysis

Symmetry adaptation, universality, and gate efficiency are central but often competing requirements in quantum algorithms for electronic structure and many-body physics. For example, fully symmetry-adapted universal operator pools typically generate long and deep quantum circuits; gate-efficient universal operator pools generally break symmetries; and gate-efficient, fully symmetry-adapted operator pools may not be universal. In this work, we analyze such symmetry dilemmas both theoretically and numerically. On the theory side, we prove that the popular, gate-efficient operator pool consisting of singlet spin-adapted singles and perfect-pairing doubles is not universal when spatial symmetry is enforced. To demonstrate the strengths and weaknesses of the three types of pools, we perform numerical simulations using an adaptive algorithm paired with operator pools that are (i) fully symmetry-adapted and universal, (ii) fully symmetry-adapted and non-universal, and (iii) breaking a single symmetry and universal. Our numerical simulations encompass three physically relevant scenarios in which the target state is (i) the global ground state, (ii) the ground state crossed by a state differing in multiple symmetry properties, and (iii) the ground state crossed by a state differing in a single symmetry property. Our results show when symmetry-breaking but universal pools can be used safely, when enforcing at least one distinguishing symmetry suffices, and when a particular symmetry must be rigorously preserved to avoid variational collapse. Together, the formal and numerical analyses provide a practical guide for designing and benchmarking symmetry-adapted operator pools that balance universality, resource requirements, and robust state targeting in quantum simulations for chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An adaptive controller for enhancing operator performance during teleoperation

An adaptive controller is developed for adjusting robot arm parameters while manipulating payloads of unknown mass and inertia. The controller is tested experimentally in a master/slave configuration where the adaptive slave arm is commanded via human operator inputs from a master. Kinematically similar six-joint master and slave arms are used with the last three joints locked for simplification. After a brief initial adaptation period for the unloaded arm, the slave arm retrieves different size payloads and maneuvers them about the workspace. Comparisons are then drawn with similar tasks where the adaptation is turned off. Several simplifications of the controller dynamics are also addressed and experimentally verified.

Carignan, Craig R.↗

Adaptive Multi-Sensor Localization Information Fusion for Autonomous Urban Air Mobility Operations

An adaptive method is developed to iteratively fuse the information provided by multiple sensors to enable autonomous urban air mobility type operations. First, noisy and bias corrupted IMU readings are processed as soon as they arrive using kinematic equations represented in the vehicle's body frame. To correct the systems drift resulting from the integration, an information content measure is introduced to decide on the environment. For the cluttered environment the information provided by environmental sensors is counted as reliable and the drift correction as accurate. For the open space, the GPS data is counted as reliable, and the drift correction is done based on the GPS readings. The measurement noise effects are minimize using Iterated Extended Kalman Filter framework. The algorithm is implemented in the in-house developed FlightDeckz simulation environment using an IMU model, simulated video recorded from a camera mounted on the vehicle (for the purpose of this study, outside scenery was generated with XPlane), which flies in an urban environment, and GPS data generated from the environment's digital map.

Onboard Perception↗

Accelerating phase field simulations through a hybrid adaptive Fourier neural operator with U-net backbone

Prolonged contact between a corrosive liquid and metal alloys can cause progressive dealloying. For one such process as liquid-metal dealloying (LMD), phase field models have been developed to understand the mechanisms leading to complex morphologies. However, the LMD governing equations in these models often involve coupled non-linear partial differential equations (PDE), which are challenging to solve numerically. In particular, numerical stiffness in the PDEs requires an extremely refined time step size (on the order of 10 -12 s or smaller). This computational bottleneck is especially problematic when running LMD simulation until a late time horizon is required. This motivates the development of surrogate models capable of leaping forward in time, by skipping several consecutive time steps at-once. In this paper, we propose a U-shaped adaptive Fourier neural operator (U-AFNO), a machine learning (ML) based model inspired by recent advances in neural operator learning. U-AFNO employs U-Nets for extracting and reconstructing local features within the physical fields, and passes the latent space through a vision transformer (ViT) implemented in the Fourier space (AFNO). We use U-AFNOs to learn the dynamics of mapping the field at a current time step into a later time step. We also identify global quantities of interest (QoI) describing the corrosion process (e.g., the deformation of the liquid-metal interface, lost metal, etc.) and show that our proposed U-AFNO model is able to accurately predict the field dynamics, in spite of the chaotic nature of LMD. Most notably, our model reproduces the key microstructure statistics and QoIs with a level of accuracy on par with the high-fidelity numerical solver, while achieving a significant 11, 200 × speed-up on a high-resolution grid when comparing the computational expense per time step. Finally, we also investigate the opportunity of using hybrid simulations, in which we alternate forward leaps in time using the U-AFNO with high-fidelity time stepping. We demonstrate that while advantageous for some surrogate model design choices, our proposed U-AFNO model in fully auto-regressive settings consistently outperforms hybrid schemes.

36 MATERIALS SCIENCE↗

TU-AB-201-05: Automatic Adaptive Per-Operative Re-Planning for HDR Prostate Brachytherapy - a Simulation Study On Errors in Needle Positioning

Purpose: To develop adaptive planning with feedback for MRI-guided focal HDR prostate brachytherapy with a single divergent needle robotic implant device. After each needle insertion, the dwell positions for that needle are calculated and the positioning of remaining needles and dosimetry are both updated based on MR imaging. Methods: Errors in needle positioning may occur due to inaccurate needle insertion (caused by e.g. the needle’s bending) and unpredictable changes in patient anatomy. Consequently, the dose plan quality might dramatically decrease compared to the preplan. In this study, a procedure was developed to re-optimize, after each needle insertion, the remaining needle angulations, source positions and dwell times in order to obtain an optimal coverage (D95% PTV>19 Gy) without exceeding the constraints of the organs at risk (OAR) (D10% urethra<21 Gy, D1cc bladder<12 Gy and D1cc rectum<12 Gy). Complete HDR procedures with 6 needle insertions were simulated for a patient MR-image set with PTV, prostate, urethra, bladder and rectum delineated. Random angulation errors, modeled by a Gaussian distribution (standard deviation of 3 mm at the needle’s tip), were generated for each needle insertion. We compared the final dose parameters for the situations (I) without re-optimization and (II) with the automatic feedback. Results: The computation time of replanning was below 100 seconds on a current desk computer. For the patient tested, a clinically acceptable dose plan was achieved while applying the automatic feedback (median(range) in Gy, D95% PTV: 19.9(19.3–20.3), D10% urethra: 13.4(11.9–18.0), D1cc rectum: 11.0(10.7–11.6), D1cc bladder: 4.9(3.6–6.8)). This was not the case without re-optimization (median(range) in Gy, D95% PTV: 19.4(14.9–21.3), D10% urethra: 12.6(11.0–15.7), D1cc rectum: 10.9(8.9–14.1), D1cc bladder: 4.8(4.4–5.2)). Conclusion: An automatic guidance strategy for HDR prostate brachytherapy was developed to compensate errors in needle positioning and improve the dose distribution. Without re-optimization, target coverage and OAR constraints may not be achieved. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are full-time employees of Philips Medical Systems Nederland B.V.

60 APPLIED LIFE SCIENCES↗

Adaptation of Commercial Current-Controlled Inverters for Operation with Virtual Oscillator Control

Virtual oscillator control (VOC) is a decentralized time-domain control technique for ac microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. VOC enables the design of modular and scalable systems where inverters can synchronize and share power without communication and in near real-time. In this paper, we show how off-the-shelf commercial inverters with current control can be reprogrammed to behave as voltage sources with virtual oscillator dynamics for deployment in islanded settings. We focus on commercial grid-tied inverters that have an inner current-control loop and show how the outer-loop controls can be straightforwardly modified to enable voltage-control-mode operation. To illustrate the practicality and ease of our approach, the proposed strategy was implemented on a 3.2 kVA experimental test bed composed of 10 SunPower-brand micro-inverters with special firmware for VOC implementation. Results from the experiments not only demonstrate feasibility of the proposed dual-loop VOC architecture on a hardware setup but also show improved voltage regulation due to the additional voltage control loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

Fuller, Charles A.↗

Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

Fuller, Charles A.↗

A multi-stage stochastic programming model for adaptive biomass processing operation under uncertainty

Variations of physical and chemical characteristics of biomass reduce equipment utilization and increase operational costs of biomass processing. Biomass processing facilities use sensors to monitor the changes in biomass characteristics. Integrating sensory data into the operational decisions in biomass processing will increase its flexibility to the changing biomass conditions. In this paper, we propose a multi-stage stochastic programming model that minimizes the expected operational costs by identifying the initial inventory level and creating an operational decision policy for equipment speed settings. These policies take the sensory information data and the current biomass inventory level as inputs to dynamically adjust inventory levels and equipment settings according to the changes in the biomass' characteristics. We ensure that a prescribed target reactor utilization is consistently achieved by penalizing the violation of the target reactor feeding rate. A case study is developed using real-world data collected at Idaho National Laboratory's biomass processing facility. We show the value of multi-stage stochastic programming from an extensive computational experiment. Our sensitivity analysis indicates that updating the infeed rate of the system, the processing speed of equipment, and bale sequencing based on the moisture level of biomass improves the processing rate of the reactor and reduces operating costs.

09 BIOMASS FUELS↗