Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

Rosenzweig, Guy↗

Optical amplifier exhibiting net phase-mismatch selected to at least partially reduce gain-induced phase-matching during operation and method of operation

An optical amplifier, such as an optical waveguide amplifier (e.g., an optical fiber amplifier or a planar waveguide) or a non-guiding optical amplifier, that exhibits a net phase-mismatch selected to at least partially reduce gain-induced phase-matching during operation thereof is disclosed. In one aspect of the invention, an optical amplifier structure includes at least one optical amplifier having a length and a gain region. The at least one optical amplifier exhibits a net phase-mismatch that varies along at least part of the length thereof selected to at least partially reduce gain-induced phase-matching during operation thereof.

47 OTHER INSTRUMENTATION↗

Fast integrator based data acquisition system for the SST-1 Thomson scattering system

An operational transconductance amplifier based fast charge-integrating module (FCIM) is designed and developed for an easy acquisition of fast Thomson scattered and background signal. FCIM based data acquisition technique can be used for the measurement of charge pulses of <20 ns duration. The response of the module is tested using a standard pulsed charge-generating module. The measuring charge range of the module depends on the integrating capacitor. Comparison of the performance of FCIM to commercially available module shows that it has better dynamic range with higher sensitivity and less measurement error. The module is quite cost effective and has many new features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiatively cooled quantum microwave amplifiers

Superconducting microwave amplifiers are essential for sensitive signal readout in superconducting quantum processors. Typically based on Josephson junctions, these amplifiers require operation at milli-Kelvin temperatures to achieve quantum-limited performance. Here, we demonstrate a quantum microwave amplifier that employs radiative cooling to operate at elevated temperatures and maintain near quantum-limited added noise. This kinetic-inductance-based parametric amplifier, patterned from a single layer of relatively high-Tc NbN thin film, maintains a high gain and meanwhile enables low added noise of 1.3 quanta when operated at 1.5 K. Remarkably, this represents only a 0.2 quanta increase compared to the performance at a base temperature of 0.1 K. Based on our findings, we also discuss the practicality of such an operating scheme for various quantum applications. By uplifting the parametric amplifiers from the mixing chamber without compromising readout efficiency, this work represents an important step toward more scalable microwave quantum technologies.

Physics↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Stability analysis of a two-stage tapered gyrotron traveling-wave tube amplifier with distributed losses

The two-stage tapered gyrotron traveling-wave tube (gyro-TWT) amplifier has achieved wide bandwidth in the millimeter wave range. However, possible oscillations in each stage limit this amplifier's operating beam current and thus its output power. To further enhance the amplifier's stability, distributed losses are applied to the interaction circuit of the two-stage tapered gyro-TWT. A self-consistent particle-tracing code is used for analyzing the beam-wave interactions. The stability analysis includes the effects of the wall losses and the length of each stage on the possible oscillations. Simulation results reveal that the distributed-loss method effectively stabilizes all the oscillations in the two stages. Under stable operating conditions, the device is predicted to produce a peak power of 60 kW with an efficiency of 29% and a saturated gain of 52 dB in the Ka-band. The 3-dB bandwidth is 5.7 GHz, which is approximately 16% of the center frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

275 C Downhole Switched-Mode Power Supply

A vee-square (V2) control based controller IC is developed for a switch mode power supply capable of operating at extreme temperature/harsh environment conditions. A buck type regulator with silicon carbide power junction field effect transistors (JFET) as power devices is used to analyze the performance of controller. Special emphases are made on the analog sub-blocks--voltage reference, operational transconductance amplifier and comparator as individual building blocks. Transformer coupled gate drives and high temperature operable magnetic cores and capacitors are identified and tested for use in the design. Conventional ceramic chip packaging of ICs combined with lead carrier type mounting of passive filter components is introduced for hybrid packaging of the complete product. The developed SMPS is anticipated to support the operation of down-hole microcontrollers and other electronics devices that require low/medium power filtered dc inputs over an operating temperature of 275 C.

42 ENGINEERING↗

Operator-sum representation for bosonic Gaussian channels

Operator-sum or Kraus representations for single-mode bosonic Gaussian channels are developed, and several of their consequences explored. The fact that the two-mode metaplectic operators acting as unitary purification of these channels do not, in their canonical form, mix the position and momentum variables is exploited to present a procedure which applies uniformly to all families in the Holevo classification. In this procedure the Kraus operators of every quantum-limited Gaussian channel can be simply read off from the matrix elements of a corresponding metaplectic operator. Kraus operators are employed to bring out, in the Fock basis, the manner in which the antilinear, unphysical matrix transposition map when accompanied by injection of a threshold classical noise becomes a physical channel, denoted D({kappa}) in the Holevo classification. The matrix transposition channels D({kappa}), D({kappa}{sup -1}) turn out to be a dual pair in the sense that their Kraus operators are related by the adjoint operation. The amplifier channel with amplification factor {kappa} and the beam-splitter channel with attenuation factor {kappa}{sup -1} turn out to be mutually dual in the same sense. The action of the quantum-limited attenuator and amplifier channels as simply scaling maps on suitable quasiprobabilities in phase space is examined in the Kraus picture. Consideration of cumulants is used to examine the issue of fixed points. The semigroup property of the amplifier and attenuator families leads in both cases to a Zeno-like effect arising as a consequence of interrupted evolution. In the cases of entanglement-breaking channels a description in terms of rank 1 Kraus operators is shown to emerge quite simply. In contradistinction, it is shown that there is not even one finite rank operator in the entire linear span of Kraus operators of the quantum-limited amplifier or attenuator families, an assertion far stronger than the statement that these are not entanglement breaking channels. A characterization of extremality in terms of Kraus operators, originally due to Choi, is employed to show that all quantum-limited Gaussian channels are extremal. The fact that almost every noisy Gaussian channel can be realized as a product of a pair of quantum-limited channels is used to construct a discrete set of linearly independent Kraus operators for these noisy Gaussian channels, including the classical noise channel, and these Kraus operators have a particularly simple structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the merit of hot ion mode for tearing mode stabilization

The stabilization of tearing modes with rf driven current benefits from the cooperative feedback loop between rf power deposition and electron temperature within the island. This effect, termed rf current condensation, can greatly enhance and localize the current driven within magnetic islands. It has previously been shown that the condensation effect opens the possibility of passive stabilization with broad rf profiles, as would be typical of LHCD for steady state operation. Here, we show that this self-healing effect can be dramatically amplified by operation in a hot ion mode, due to the additional electron heat source provided by the hotter ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transverse pumped laser amplifier architecture

An optical gain architecture includes a pump source and a pump aperture. The architecture also includes a gain region including a gain element operable to amplify light at a laser wavelength. The gain region is characterized by a first side intersecting an optical path, a second side opposing the first side, a third side adjacent the first and second sides, and a fourth side opposing the third side. The architecture further includes a dichroic section disposed between the pump aperture and the first side of the gain region. The dichroic section is characterized by low reflectance at a pump wavelength and high reflectance at the laser wavelength. The architecture additionally includes a first cladding section proximate to the third side of the gain region and a second cladding section proximate to the fourth side of the gain region.

42 ENGINEERING↗

Transverse pumped laser amplifier architecture

An optical gain architecture includes a pump source and a pump aperture. The architecture also includes a gain region including a gain element operable to amplify light at a laser wavelength. The gain region is characterized by a first side intersecting an optical path, a second side opposing the first side, a third side adjacent the first and second sides, and a fourth side opposing the third side. The architecture further includes a dichroic section disposed between the pump aperture and the first side of the gain region. The dichroic section is characterized by low reflectance at a pump wavelength and high reflectance at the laser wavelength. The architecture additionally includes a first cladding section proximate to the third side of the gain region and a second cladding section proximate to the fourth side of the gain region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K

We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and readout by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output signal. We measured a peak strain sensitivity of 1.5x10{sup -20} Hz{sup -1/2} at 2942.9 Hz. A strain sensitivity of better than 5x10{sup -20} Hz{sup -1/2} has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than 1 order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3 kHz range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact cryogenically cooled Ti:Sapphire dual multi-kilohertz amplifiers for synchrotron radiation ultra-fast x-ray applications

A titanium-doped sapphire regenerative dual-amplifier array operating at multi-kHz repetition rates has been developed for synchrotron radiation ultra-fast x-ray applications. The thermal lensing of the crystal in the amplifiers is virtually eliminated by cryogenic cooling of the laser crystal. The output energy of the amplifiers is measured to be greater than 2.6 mJ and the pulse length was compressed to less than 70 fs. The output laser mode is a near perfect Gaussian TEM00 with an M{sup 2} factor of 1.02. The performance of the amplifier system is in excellent agreement with theoretical calculation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma relativistic microwave amplifier with smooth frequency tuning from 2.4 to 3.2 GHz

Earlier, it was shown that the plasma relativistic microwave amplifier can operate at two frequencies, 2 and 3.2 GHz. In the present work, it is shown that, by varying the plasma density from one microwave pulse to another, it is possible to amplify the input signals to a power of 50-80 MW at any frequency in the range 2.4-3.2 GHz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An improved suppression method of the transverse-electromagnetic mode leakage with two reflectors in the triaxial klystron amplifier

Suppression of the transverse-electromagnetic (TEM) mode leakage is crucial in the design of a triaxial klystron amplifier with high gain, because a small microwave leakage from the buncher or the output cavity could overwhelm the input signal with low power. In this paper, a specially designed reflector is proposed to suppress the TEM mode leakage, whose axial electric field is approximately zero at the beam radial position. Theoretical analysis indicates that the reflector introduces little influence on the normal modulation of the beam while keeping a high reflection coefficient. By using two such reflectors with different eigen frequencies located in front of the buncher cavity and the output cavity, respectively, an improved triaxial klystron amplifier is presented. The simulation results show that the reflectors substantially decrease the TEM mode leakage power and achieve very good isolation among the cavities. The improved triaxial klystron amplifier can operate normally with 10's kW microwave injection without self-oscillations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flux-pumped impedance-engineered broadband Josephson parametric amplifier

Broadband quantum-limited amplifiers play a critical role in the single-shot readout of superconducting qubits, but a popular implementation, the traveling wave parametric amplifier, involves a complex design and fabrication process. Here, we present a simple design for a Josephson parametric amplifier, using a lumped element resonator comprising a superconducting quantum interference device whose useful bandwidth is enhanced with an on-chip impedance-matching circuit. Additionally, we demonstrate a flux-coupling geometry that maximizes the coupling to the Josepson loop and minimizes spurious excitation of the amplifier resonant circuit. The amplifier, which operates in a flux-pumped mode, is demonstrated with a power gain of more than 20dB over a bandwidth of about 300MHz, where approximate noise measurements indicate quantum-limited pehrformance. A procedure is given for optimizing the bandwidth for this kind of amplifier, using a linearized circuit simulation while minimizing non-linearities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 10-Gb/s Driver/Receiver ASIC and Optical Modules for Particle Physics Experiments

We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗