Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improved Architectures and Training Algorithms for Deep Operator Networks

Operator learning techniques have recently emerged as a powerful tool for learning maps between infinite-dimensional Banach spaces. Trained under appropriate constraints, they can also be effective in learning the solution operator of partial differential equations (PDEs) in an entirely self-supervised manner. In this work we analyze the training dynamics of deep operator networks (DeepONets) through the lens of Neural Tangent Kernel theory, and reveal a bias that favors the approximation of functions with larger magnitudes. To correct this bias we propose to adaptively re-weight the importance of each training example, and demonstrate how this procedure can effectively balance the magnitude of back-propagated gradients during training via gradient descent. We also propose a novel network architecture that is more resilient to vanishing gradient pathologies. Taken together, our developments provide new insights into the training of DeepONets and consistently improve their predictive accuracy by a factor of 10-50x, demonstrated in the challenging setting of learning PDE solution operators in the absence of paired input-output observations.

97 MATHEMATICS AND COMPUTING↗

Critical operating stress of persistent slip bands in Cu

This work elucidates the dependence of operating stress of persistent slip bands (PSB) on the channel width and wall dislocation density. Using Cu as a model system and molecular dynamics as the main investigative tool, a new length scale effect, namely the wall dislocation spacing, is provided to enhance theoretical understanding of PSBs. It is discovered that the operation of PSB is a thermally activated event in which operating stress is inversely related to the wall dislocation spacing, strain rate and temperature. Leveraging the existing framework of confined layer slip in nanoscale metallic multilayers and classical nucleation theory, a mathematical model describing the rate- and temperature- dependent PSB operating stress is here proposed.

36 MATERIALS SCIENCE↗

Dynamic Process Intensification of Binary Distillation via Periodic Operation

This paper applies the concept of dynamic intensification (defined as changes to the dynamics, operation strategy, and/or control of a process that lead to a substantially more efficient processing path) to binary distillation columns. The resulting strategy consists of manufacturing a target product as a blend of two auxiliary products, both having lower energy demands than a reference value, which corresponds to producing the target product(s) in a column operating at steady state. Here, a discussion of the appropriate control structures and switching strategies between the two auxiliary products is provided. An extensive case study concerning the separation of a methanol–1-propanol mixture was carried out, demonstrating that energy savings in the order of 1.4% are possible with no disruption in product quality or production rate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the Low Risk of SSR in Type III Wind Turbines Operating in Grid-Forming Control: Preprint

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze the dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet injectors for the ITER disruption mitigation systems are discussed.

Combs, Stephen Kirk↗

Electroweak sphaleron with dimension-six operators

New physics at the TeV scale can affect the dynamics of the electroweak phase transition in many ways. In this paper, we evaluate its impact on the rate of baryon-number violation via sphaleron transitions. We parameterize the effect of new physics with dimension-6 operators, and we use the Newton-Kantorovich method to numerically solve the resulting equations of motion. Depending on the sign of the coefficient of the dimension-6 operators, their presence can either increase or decrease the sphaleron energy at the level of a few percent, parametrically of order m$2\atop{W}$/Λ 2 where Λ is the scale suppressing the dimension-6 operator. Lastly, the baryon-number washout condition, typically written as v c /T c >1, is directly proportional to the sphaleron energy, and we discuss how the presence of dimension-6 operators can affect electroweak baryogenesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation and Control of Soft Switching Solid State Transformer as a Virtual Synchronous Machine for Photovoltaic Application

Possibility for control and operation of a three-phase solid state soft switching transformer based as a virtual synchronous machine or synchronverter has been investigated in this paper. The soft switching solid state transformer is used as an interface between the ac grid and a photovoltaic power generation unit supported by a battery bank. The control architecture investigated in this paper is that of a synchronverter to achieve inertial support to the grid and local loads. The operation of the soft switching solid state transformer has also been investigated as a V S M during unbalanced/distorted grid voltage condition. Control objective to achieve oscillation free power transfer between the ports (photovoltaic, battery and grid) has been achieved. The presented architecture has been verified for several important case studies via numerical simulations based on MATLAB/Simulink domain.

grid current controller↗

Allocation and Operation of A Hydropneumatic Energy Storage with Building Microgrid

Behind-meter application for a recently invented hydropneumatic Ground-Level Integrated Diverse Energy Storage (GLIDES) is focused in this research. Considering possible uncertainties from solar radiation and electricity load in a building microgrid, two-stage stochastic programming is adopted for 15-min operation and a mixed-integer nonlinear stochastic model is built with integrated energy systems of GLIDES, solar panel and power generating unit. In order to make the model computationally tractable, we use sample average approximate method to decrease associated complexity with sample size and improve solving efficiency. The experimental results in deterministic and stochastic operation indicate that best candidate solution from SAA are superior to the solution from expected value problem in terms of optimality gap and variance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing

Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.

Aguayo, Jared M.↗

Roles of Dynamic State Estimation in Power System Modeling, Monitoring and Operation

—Power system dynamic state estimation (DSE) remains an active research area. This is driven by the absence of accurate models, the increasing availability of fast-sampled, time synchronized measurements, and the advances in the capability, scalability, and affordability of computing and communications. This paper discusses the advantages of DSE as compared to static state estimation, and the implementation differences between the two, including the measurement configuration, modeling framework and support software features. The important roles of DSE are discussed from modeling, monitoring and operation aspects for today’s synchronous machine dominated systems and the future power electronics-interfaced generation systems. Several examples are presented to demonstrate the benefits of DSE on enhancing the operational robustness and resilience of 21st century power system through time critical applications. Future research directions are identified and discussed, paving the way for developing the next generation of energy management systems.

Zhao, Junbo↗

A Bilevel Voltage Regulation Operation for Distribution Systems With Self-Operated Microgrids

The emerging of microgrids in distribution systems has significantly enhanced the resilience of power grids. However, the operators of a distribution system and microgrids therein can be different and have accessibility to different devices. To model the operation of such a grid, this work proposes a bilevel formulation and probes into the voltage regulation operation, considering the interaction between different systems. The proposed bilevel formulation considers the cooperation of active energy resources (AER), transformer tap-changers, and capacitor banks that are controlled by different operators. To facilitate the solution time of the target bilevel optimization, the lower-level problems with different objectives are modeled using deep neural networks (DNNs) which are then converted into a set of constraints. Hence, the bilevel problem can be reformed to a single-level problem. Lastly, the proposed solution procedures are validated using a customized joint system constructed by the IEEE 123-bus system and a real distribution system in Iowa. According to the numerical validation results, the solution time of the proposed nonlinear activation function based DNN model is 69 times faster than other methods in solving voltage regulation with a bilevel structure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating instabilities in a Rotating Detonation Combustor Operating with Natural Gas-Hydrogen Fuel Blend – Effect of Air Preheat and Annulus Width

Propagation characteristics of a detonation wave in an air-breathing Rotating Detonation Combustor (RDC) using natural gas-hydrogen fuel blends is presented in this paper. Short duration (~up to 6s) experiments were performed on a 152.4mm OD uncooled RDC with two different annulus gap widths (5.08mm and 7.62mm) over a range of equivalence ratios (0.6–1.0) at varying inlet air temperatures (~65°C-204°C) and natural gas content (up to 15%) with pre-combustion operating pressure slightly above ambient.It was observed that the RDC, with an annulus gap width of 5.08mm, was inherently unstable when natural gas (NG) was added to the hydrogen fuel while operating at pre-combustion pressures near ambient and at an inlet air temperature of 65°C. Increasing the annulus gap width to 7.62mm improved the stability of the detonation wave at similar temperatures and pressure permitting operation with as much as 5% NG by volume. While observed speeds of the detonation waves were still below theoretical values, an increase in inlet air temperature reduced the variability in wave speed. The frequency analysis thus explored in this study is an effort to quantify detonation instability in an RDC under varying operational envelope. The data presented is relevant towards developing strategies to sustain a stable detonation wave in an RDC using natural gas for land based power generation.

Roy, Arnab↗

Theoretical Understanding of Effects of Operating Modes on the Performance Durability of Solid Oxide Cells: A Comparison between Potentiostatic and Galvanostatic Operations

In solid oxide cells (SOCs), the choice between galvanostatic (constant current) and potentiostatic (constant voltage) modes does not significantly affect the performance of SOCs as long as the cell components remain unchanged and intact. However, the degradation of cell components, which leads to changes in electrochemical and physical properties of the cell, elevates the importance of the selected operating mode. This paper aims to investigate the effects of galvanostatic and potentiostatic operating modes on the evolving properties of SOCs and their subsequent influence on performance durability. Employing non-equilibrium thermodynamic analysis, a crucial approach for understanding the degradation phenomena within an active electrochemical system, this study aims to provide in-depth insights into how these operating modes affect the longevity and efficacy of SOCs. Key findings include: In cases where oxygen electrode (OE) degradation is accelerated by higher partial pressure of oxygen ( p O 2 ), operating under constant voltage electrolysis can mitigate the high p O 2 at the OE|electrolyte (OE|EL) interface. Conversely, if OE degradation occurs more rapidly under a lower p O 2 , constant current electrolysis is more effective in suppressing degradation by achieving a high p O 2 at the OE|EL interface. For degradation of the fuel electrode (FE) due to higher p O 2 , constant current electrolysis is beneficial for more stable performance, which helps maintain low p O 2 at the FE|EL interface. When FE degradation is accelerated by lower p O 2 , constant voltage electrolysis can avert low p O 2 at the FE|EL interface. In practical scenarios, more complex degradation mechanisms come into play, especially when p O 2 significantly deviates from initial conditions. Degradation in one electrode can influence p O 2 in the other electrode, a phenomenon more pronounced in potentiostatic than in galvanostatic electrolysis.

Electrochemistry↗

Novel Organosulfur-Based Electrolytes for Safe Operation of High Voltage Li-ion Batteries over a Wide Operating Temperature

This project addresses the failure of conventional electrolytes and enables high-voltage operation of lithium-ion batteries (LIBs) by developing a novel organosulfur-based electrolyte system. To achieve this goal, we first designed and synthesized new organosulfur solvents that functionalized with strong electron-withdrawing groups such as fluoroalkyl and cyano substituents. Through regio-specific molecular engineering, supported by theoretical calculations, we lowered the highest occupied molecular orbital (HOMO) energy levels of these molecules to increase their anodic stability for high-voltage operation. We then optimized the formulation of the organosulfur-based electrolyte with additives, co-solvents and salts tailored to the newly synthesized solvent molecules. In parallel, we utilized advanced spectroscopic techniques—including in situ FTIR, EIS, and DEMS—to thoroughly elucidate the mechanisms of interaction between the electrolyte and electrode materials. Finally, we evaluated 2 Ah pouch cells under both normal and extreme conditions. Pouch cells with the newly developed electrolyte system demonstrated >90% capacity retention after 500 cycles under 4.5 V operating voltage, >80% capacity retention after 1000 cycles in coin cell level. In addition, the cells exhibited high safety and reliable operation capability over a wide temperature range from −30 °C to +45 °C.

25 ENERGY STORAGE↗

Development and Demonstration of a Class 6 Range-Extended Electric Vehicle for Commercial Pickup and Delivery Operation: Preprint

Range-extended hybrids are an attractive option for medium- and heavy-duty commercial vehicle fleets because they offer the efficiency of an electrified powertrain with the driving range of a conventional diesel powertrain. The vehicle essentially operates as if it was purely electric for most trips, while ensuring that all commercial routes can be completed in any weather conditions or geographic terrain. Fuel use and point-source emissions can be significantly reduced, and in some cases eliminated, as many shorter routes can be fully electrified with this architecture. Under a U.S. Department of Energy (DOE)-funded project for Medium- and Heavy-Duty Vehicle Powertrain Electrification, Cummins has developed a plug-in hybrid electric Class 6 truck with a range-extending engine designed for pickup and delivery application. The National Renewable Energy Laboratory (NREL) assisted by developing representative workday drive cycles for Class 6 operation and an adapted cycle to enable vehicle track testing. A novel, automated driving system was utilized by Southwest Research Institute (SwRI) to improve the repeatability of the track testing conducted to quantify vehicle energy consumption. Cummins used a drivetrain model to design the hybrid control system for increased fuel savings. The control system functionality and fuel savings objective of 50% or more were confirmed by track testing described in this paper.

ADVANCED PROPULSION SYSTEMS↗

Modeling Flexible Generator Operating Regions via Chance- constrained Stochastic Unit Commitment

Here, we introduce a novel chance-constrained stochastic unit commitment model to address uncertainty in renewables' production uncertainty in power systems operation. For most thermal generators,underlying technical constraints that are universally treated as "hard" by deterministic unit commitment models are in fact based on engineering judgments, such that system operators can periodically request operation outside these limits in non-nominal situations, e.g., to ensure reliability. We incorporate this practical consideration into a chance-constrained stochastic unit commitment model, specifically by in-frequently allowing minor deviations from the minimum and maximum thermal generator power output levels. We demonstrate that an extensive form of our model is computationally tractable for medium-sized power systems given modest numbers of scenarios for renewables' production. We show that the model is able to potentially save significant annual production costs by allowing infrequent and controlled violation of the traditionally hard bounds imposed on thermal generator production limits. Finally, we conduct a sensitivity analysis of optimal solutions to our model under two restricted regimes and observe similar qualitative results.

42 ENGINEERING↗