Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗

Enhancing analytical merits of laser-induced breakdown spectroscopy of hydrogen isotopes using an orthogonal double-pulsing scheme

Accurate detection and quantification of hydrogen isotopes in solid materials are vital for diverse applications, including fusion energy, hydrogen storage, and tritium production. Laser-induced breakdown spectroscopy (LIBS) is a well established, rapid, standoff method for this purpose, but it faces challenges related to the analytical merits required for isotopic analyses. In this study, we enhance the analytical and detection capabilities of traditional single-pulse LIBS by implementing an orthogonal double pulsing approach, focusing on the analysis of a range of 2 H concentrations in Zircaloy-4 substrates (acting as a proxy for 3 H). The double-pulse experiments employed an orthogonal re-heating configuration with two nanosecond Nd:YAG lasers. We systematically evaluated critical parameters affecting the signal intensity in double-pulse LIBS, including interpulse delay, ambient gas pressure, and heating laser energy. Finally, our results demonstrate that employing an orthogonal double-pulse scheme significantly enhances 2 H α emission while minimizing line broadening and self-absorption, ultimately improving the technique’s analytical capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved filters for angular filter refractometry

Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.

47 OTHER INSTRUMENTATION↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Path-Integrated Stereo X-Ray Digital Image Correlation: Resolving the Violation of Conservation of Intensity

In this study, x-ray imaging addresses many challenges with visible light imaging in extreme environments, where optical diagnostics such as digital image correlation (DIC) and particle image velocimetry (PIV) suffer biases from index of refraction changes and/or cannot penetrate visibly occluded objects. However, conservation of intensity—the fundamental principle of optical image correlation algorithms—may be violated if ancillary components in the X-ray path besides the surface or fluid of interest move during the test. The test series treated in this work sought to characterize the safe use of fiber-epoxy composites in aerospace and aviation industries during fire accident scenarios. Stereo X-ray DIC was employed to measure test unit deformation in an extreme thermal environment involving a visibly occluded test unit, incident surface heating to temperatures above 600°C, and flames and soot from combusting epoxy decomposition gasses. The objective of the current work is to evaluate two solutions to resolve the violation of conservation of intensity that resulted from both the test unit and the thermal chamber deforming during the test. The first solution recovered conservation of intensity by pre-processing the path-integrated X-ray images to isolate the DIC pattern of the test unit from the thermal chamber components. These images were then correlated with standard, optical DIC software. The second solution, called Path-Integrated Digital Image Correlation (PI-DIC), modified the fundamental matching criterion of DIC to account for multiple, independently-moving components contributing to the final image intensity. The PI-DIC algorithm was extended from a 2D framework to a stereo framework and implemented in a custom DIC software. Both solutions accurately measured the cylindrical shape of the undeformed test unit, recovering radii values of R = 76.20±0.12 mm compared to the theoretical radius of R theor = 76.20 mm. During the test, the test unit bulged asymmetrically as decomposition gasses pressurized the interior and eventually burned in a localized jet. Both solutions measured the heterogeneous radius of this bulge, which reached a maximum of approximately R = 91 mm, with a discrepancy of 2–3% between the two solutions. Two solutions that resolve the violation of conservation of intensity for path-integrated X-ray images were developed. Both were successfully employed in a stereo X-ray DIC configuration to measure deformation of an aluminum-skinned, fiber-epoxy composite test unit in a fire accident scenario.

47 OTHER INSTRUMENTATION↗

Density variance dynamics in disparate shock tubes

This report discusses two experiments which investigate thin layer, heavy curtain fragmentation from the perspective of a Reynolds-Averaged mix model, in drastically disparate experimental regimes. The first, the centimeter/millisecond-scale “Horizontal Shock Tube” (HST) is a compressed-gas piston-driven shock tube experiment. The second, the “Multishock thin layer” (Mshock) experiment performed at the National Ignition Facility, is a micrometer/nanosecond-scale laser-driven shock tube experiment. Both are situations in which a heavy plane layer (a ‘curtain’) is initially suspended in a lighter medium. After being shocked from at least one side, the layer translates while its interfaces evolve due to the excitation of the Richtmyer-Meshkov instability at its surfaces. The evolution of density variance, which initially exists only on the surface of the layer, as it comes to encompass the whole layer interior is used as a description of layer fragmentation and dissolution. These experiments have each been simulated in the Los Alamos National Laboratory multi-physics code xRAGE, which includes fundamental hydrodynamics, extended plasma physics and radiation effects which are important to drive the high-energy density experiment, and the Besnard-Harlow-Rauenzahn (BHR) turbulence model. In each, the principal diagnostic for comparison is an experimental metric for the density (co)variance, b, which tracks the moments of the density field at the curtain interfaces and body. Due to experimental constraints in different regimes (i.e. optical diagnostics can be deployed on conventional shock tubes, while the plasma shock tubes must be imaged by x-rays; interfaces can be imposed to specification on laser-driven experiments, which are stored in the solid phase, while conventional experiments have imperfect control of the flow fields which separate the layer, etc.) the experiments are not designed to be perfect scaled cognates of one another. However, despite the separation of six orders of magnitude of scaling in time, and four in space, we are able to demonstrate that the same turbulence model, operating in the same fashion in the same computer code, is able to reproduce results in each experiment, by tracking evolution due to common relevant physics. Additionally, we will present preliminary work toward density variance comparisons in a single-interface Richtmyer-Meshkov configuration, the conventional fluid “Vertical Shock Tube” (VST) experiment, and the Modal Initial Conditions (ModCons) campaign fielded at the OMEGA-EP laser facility.

42 ENGINEERING↗

An updated technique to obtain explosive kinetics data on microsecond timescales

There are few techniques available for chemists to obtain time-to-explosion data with known temperature inputs at the early stages of the design and synthesis of new explosives. In the 1960s, a technique was developed to rapidly heat milligram-quantities of confined explosives to ~1000 K on microsecond timescales. Wenograd loaded explosives inside stainless steel hypodermic needles, connected them to a fireset and rapidly discharged a capacitor through the steel. He obtained the temperature by measuring the needle resistance in a Wheatstone bridge arrangement and the time to explosion from a needle rupture. However, owing to the narrow-gauge needles used in the original research, the experiment was only possible with melt-castable explosives; it was never replicated, and modern diagnostics are now available with advances beyond the 1960s. Here, we report the development of the High Explosives Initiation Time (HEIT) test, which utilizes a 250 J pulsed power system to heat the needles. This work extends the Wenograd approach by using optical diagnostics, computational modeling, and advanced techniques to measure needle resistance and needle rupture. Preliminary rate information for pentaerythritol tetranitrate (PETN) will be presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Bulk Spray and Individual Plume Characterization of LPG and Iso-Octane Sprays at Engine-Like Conditions

This study presents experimental and numerical examination of directly injected (DI) propane and iso-octane, surrogates for liquified petroleum gas (LPG) and gasoline, respectively, at various engine like conditions with the overall objective to establish the baseline with regards to fuel delivery required for future high efficiency DI-LPG fueled heavy-duty engines. Sprays for both iso-octane and propane were characterized and the results from the optical diagnostic techniques including high-speed Schlieren and planar Mie scattering imaging were applied to differentiate the liquid-phase regions and the bulk spray phenomenon from single plume behaviors. The experimental results, coupled with high-fidelity internal nozzle-flow simulations were then used to define best practices in CFD Lagrangian spray models. Optical imaging revealed that unlike iso-octane, propane’s spray propagation was fed by its flash boiling, spray collapse, and high degree of vaporization, resulting in a direct proportionality of propane’s penetration length to temperature. These unique features of propane and its variation from iso-octane’s spray pattern, contributed to its classification as an unconventional spray. Appropriate corrections to the injection and breakup models were developed to reproduce the under-expanded jet dynamics and to mimic the flash boiling-driven spray development observed with propane sprays. The simulation results were found to be sensitive to cone and inclusion angles of the blob injector. The current work represents a first assessment of the capability of the commonly available models for engine-spray simulations and highlights the fact that, despite the reasonable agreement obtained in the fuel vapor morphology, the representation of the liquid phase lacks accuracy and requires further model development.

02 PETROLEUM↗

Investigating the origin of the far-field reflection interference fringe (RIF) of microdroplets

We show that the reflection interference fringe (RIF) is formed on a screen far away from the microdroplets placed on a prism-based substrate, which have low contact angles and thin droplet heights, caused by the dual convex–concave profile of the droplet, not a pure convex profile. The geometric formulation shows that the interference fringes are caused by the optical path difference when the reflected rays from the upper convex profile at the droplet–air interface interfere with reflection from the lower concave profile at oblique angles lower than the critical angle. Analytic solutions are obtained for the droplet height and the contact angle out of the fringe number and the fringe radius in RIF from the geometric formulation. Furthermore, the ray tracing simulation is conducted using the custom-designed code. The geometric formulation and the ray tracing show excellent agreement with the experimental observation in the relation between the droplet height and the fringe number and the relation between the contact angle and the fringe radius. This study is remarkable as the droplet's dual profile cannot be easily observed with the existing techniques. However, the RIF technique can effectively verify the existence of a dual profile of the microdroplets in a simple setup. In this work, the RIF technique is successfully developed as a new optical diagnostic technique to determine the microdroplet features, such as the dual profile, the height, the contact angle, the inflection point, and the precursor film thickness, by simply measuring the RIF patterns on the far-field screen.

42 ENGINEERING↗

Measurement of engine-oil fuel dilution using laser induced florescence spectroscopy

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil, or fuel in oil (FiO). Fuel dilution of oil is believed to be one of the underlying mechanisms that promotes low speed pre-ignition (LSPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of transient measurements, the LIF technique resolves transient dilution on the minutes time scale, making it possible to study the relation between FiO and LSPI. The measurement is based on adding a dye (ca. 500 ppm) to the fuel and monitoring for its presence in the oil via LIF. The instrument contains a 532-nm laser diode, and a spectrometer to resolve the LIF spectra. A fiber-optic assembly links the instrument to the engine measurement location; the probe is in a Y-configuration with the six fibers around one on a common probe end that connects to the engine; the Y-assembly legs are connected to the instrument; the two legs are the six fibers for transporting the laser light, and the single fiber for the fluorescence. We have expanded on our previous work (Parks et al, SAE paper 2007-01-4108, 2007), by demonstrating the diagnostic technique with to measure transient oil dilution on a 2.0-liter GM ECOTEC LNF single cylinder SI engine. The proposed LIF diagnostic will be critical in studying oil-dilution correlation with LSPI events.

Neupane, Sneha↗

Kinematics of femtosecond laser-generated plasma expansion: Determination of sub-micron density gradient and collisionality evolution of over-critical laser plasmas

An optical diagnostic based on resonant absorption of laser light in a plasma is introduced and is used for the determination of density scale lengths in the range of 10 nm to >1 μm at the critical surface of an overdense plasma. This diagnostic is also used to extract the plasma collisional frequency, allowing inference of the temporally evolving plasma composition on the tens of femtosecond timescale. This is found to be characterized by two eras: the early time and short scale length expansion (L < 0.1λ), where the interaction is highly collisional and target material dependent, followed by a period of material independent plasma expansion for longer scale lengths (L > 0.1λ); this is consistent with a hydrogen plasma decoupling from the bulk target material. Density gradients and plasma parameters on this scale are of importance to plasma mirror optical performance and comment is made on this theme.

Scott, G. G. (ORCID:000000032772372X)↗

A Sample of Massive Black Holes in Dwarf Galaxies Detected via [Fe x] Coronal Line Emission: Active Galactic Nuclei and/or Tidal Disruption Events

The massive black hole (BH) population in dwarf galaxies ( M BH ≲ 10 5 M ⊙ ) can provide strong constraints on the origin of BH seeds. However, traditional optical searches for active galactic nuclei (AGNs) only reliably detect high-accretion, relatively high-mass BHs in dwarf galaxies with low amounts of star formation, leaving a large portion of the overall BH population in dwarf galaxies relatively unexplored. Here, we present a sample of 81 dwarf galaxies ( M $\star$ ≤ 3 × 10 9 M ⊙ ) with detectable [Fe x]λ6374 coronal line emission indicative of accretion onto massive BHs, only two of which were previously identified as optical AGNs. Here, we analyze optical spectroscopy from the Sloan Digital Sky Survey and find [Fe x]λ6374 luminosities in the range L [Fe x] ≈ 10 36 –10 39 erg s –1 , with a median value of 1.6 × 10 38 erg s –1 . The [Fe x]λ6374 luminosities are generally much too high to be produced by stellar sources, including luminous Type IIn supernovae (SNe). Moreover, based on known SNe rates, we expect at most eight Type IIn SNe in our sample. That said, the [Fe x]λ6374 luminosities are consistent with accretion onto massive BHs from AGNs or tidal disruption events (TDEs). We find additional indicators of BH accretion in some cases using other emission line diagnostics, optical variability, and X-ray and radio emission (or some combination of these). However, many of the galaxies in our sample only have evidence for a massive BH based on their [Fe x]λ6374 luminosities. This work highlights the power of coronal line emission to find BHs in dwarf galaxies missed by other selection techniques and to probe the BH population in bluer, lower-mass dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Representative Phenomena of Cyclic Turbulent Combustion in High-Pressure Fuel Sprays

Abstract Cyclic variations in conventional diesel combustion engines can lead to large differences in engine out emissions even at steady operation. This study uses an optically accessible constant-pressure flow chamber to acquire fuel injections in quick succession to analyze mixing, auto-ignition, and combustion of diesel-surrogate n-heptane using multiple high-speed optical diagnostics. Prior studies have utilized fewer injections and/or they rely on analysis of ensemble average behavior. These approaches do not yield information on injection-to-injection variation or provide confidence in utilizing individual injection measurements for high-fidelity computational fluid dynamics(CFD) model validation. In this study, a large set of 500 injections is used to obtain global parameters including liquid length, vapor penetration length, ignition delay time, and lift-off length. Results for multiple injections are presented to illustrate large injection to injection variations. Potential sources for these variations are analyzed to conclude localized, small scale turbulence and rate of injection variations as the likely sources. Then, a statistical method based on z-scores is proposed and implemented to identify instantaneous injections that best represent the bulk data-set of jet boundaries measured independently by three different diagnostics. This synthesis of statistics-guided screening of data set and ensemble-average analysis offers higher confidence for CFD model validation relying upon both a representative single and average injection results.

42 ENGINEERING↗

Shock-induced kinetics and cellular structures of liquid nitromethane detonation

Using a combination of high-speed diagnostics, optical pyrometry, velocimetry and video photography, we examine the spatiotemporal reaction kinetics of a prototypical high-energy explosive, liquid nitromethane (NM), as we drive this high explosive into detonation. The detonations were initiated by powerful shock waves whose durations (4 ns) were shorter than the characteristic time associated with the reaction (7 ns). Simple optical spectroscopy alone cannot characterize the kinetics with high time resolution because the reactants and products are flowing at a high velocity of ~6 km/s (6 µm/ns). Additionally, every detection volume behind the shock front contains material initiated over a range of times. High spatial resolution can be obtained by probing interfaces where the shock enters or breaks out of the NM. In addition, we obtain cellular patterns imprinted on the luminous shock front by the two-stage explosion in NM. These spatiotemporal patterns arise naturally as a result of the asymmetry produced by the moving shock front. In this way the shock front serves as a thin moving intrinsic optical gauge that reports and characterizes the two-stage NM explosion behind the front.

42 ENGINEERING↗

Fundamental insights on ignition and combustion of natural gas in an active fueled pre-chamber spark-ignition system

Pre-chamber spark-ignition (PCSI), either fueled or non-fueled, is a leading concept with the potential to enable diesel-like efficiency in medium-duty (MD) and heavy-duty (HD) natural gas (NG) engines. However, the inadequate scientific base and simulation tools to describe/predict the underlying processes governing PCSI systems is one of the key barriers to market penetration of PCSI for MD/HD NG engines. To this end, experiments were performed in a heavy-duty, optical, single-cylinder engine fitted with an active fueled PCSI module. Furthermore, the spatial and temporal progress of ignition and subsequent combustion of lean-burn natural gas using PCSI system were studied using optical diagnostic imaging and heat release analysis based on main-chamber and pre-chamber pressure measurements.

42 ENGINEERING↗

Temperature measurements in heavily-sooting ethylene/air flames using synchrotron x-ray fluorescence of krypton

High-fidelity temperature field measurements have been made for several heavily-sooting ethylene/air flames that have historically been challenging environments for conventional optical diagnostics. These challenges have largely been overcome here, in this study, by conducting x-ray fluorescence (XRF) measurements of a Kr fluorescent agent in the hard x-ray regime (15 keV). The current methodology presents a more economical diagnostic than a previously reported implementation of the Kr-XRF method, by limiting seeding of the expensive fluorescent agent to only the fuel stream flows. Detailed reacting flow simulations have been used to interpret experimental signals by tracking the mole fraction of the fluorescent agent in the flow field. Simulated Kr densities are in excellent agreement with measurements throughout the flow field. Temperature measurements of the flow field also agree well with simulations and recent literature studies. However, uncertainties in the measurements become increasingly large downstream of the burner surface as the krypton fraction drops due to mixing of the fuel and co-flow streams. Additionally, we demonstrate that soot particles in the heavily sooting flames studied do not impede the Kr-XRF measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scaling of oxygen-methane reacting coaxial jets using x-ray fluorescence to measure mixture fraction

Stoichiometric mixing length L s of reacting coaxial jet flames is a critical scaling parameter for liquid rocket engine combustors. Previous studies have shown that L s for shear coaxial flames can be scaled like their non-reacting counterparts using a non-dimensional momentum flux ratio J. In addition, stoichiometric mixing lengths of reacting and nonreacting coaxial jets collapse upon a single line by altering J using an effective outer flow gas density. This effective density is calculated from a modified version of the equivalence principle, originally developed by Tacina and Dahm [1, 2] and accounts for the effects of heat release on mixing. However, previous studies also required a second nonphysical scaling constant S c for the reacting jets, which is not predicted by the equivalence principle [3]. It was originally hypothesized that S c is attributed to the limitation of hydroxyl (OH) planar laser-induced fluorescence, which only infers L s . Direct quantitative measurement of conserved scalar fields using conventional optical diagnostics is difficult due to the lack of a tracer that easily fluoresces, survives high temperature oxygen flames, and is not dominated by quenching effects. To measure a conserved scalar field, this work implements x-ray fluorescence of Kr and Ar tracers to obtain quantitative mixture fraction fields. From these mixture fraction fields, stoichiometric mixing lengths for two CH 4 /O 2 flames are calculated and scaled against nonreacting coaxial mixing lengths using the equivalence principle. By directly measuring the stoichiometric mixing length, it is established that the additional constant is a byproduct of the OH measurement technique and the equivalence principle fully captures the scaling. Finally, comparison with high-fidelity simulation of the flame further supports this conclusion. In addition to further strengthening this scaling method, this work represents the first use of x-ray fluorescence to make quantitative conserved scalar measurements in turbulent flames.

33 ADVANCED PROPULSION SYSTEMS↗

Influence of pilot-fuel mixing on the spatio-temporal progression of two-stage autoignition of diesel-sprays in low-reactivity ambient fuel-air mixture

The spatial and temporal locations of autoignition for direct-injection compression-ignition engines depend on fuel chemistry, temperature, pressure, and mixing trajectories in the fuel jets. Dual-fuel systems can provide insight into both fuel-chemistry and physical effects by varying fuel reactivities and engine operating conditions. In this context, the spatial and temporal progression of two-stage autoignition of a diesel-fuel surrogate, n-heptane, in a lean-premixed charge of synthetic natural-gas (NG) and air is imaged in an optically accessible heavy-duty diesel engine. The lean-premixed charge of NG is prepared by fumigation upstream of the engine intake manifold. Optical diagnostics include high-speed (15kfps) cool-flame chemiluminescence-imaging as an indicator of low-temperature heat-release (LTHR) and OH* chemiluminescence-imaging as an indicator high-temperature heat-release (HTHR). NG prolongs the ignition delay of the pilot fuel and increases the combustion duration. Zero-dimensional chemical-kinetics simulations provide further understanding by replicating a Lagrangian perspective for mixtures evolving along streamlines originating either at the fuel nozzle or in the ambient gas, for which the pilot-fuel concentration is either decreasing or increasing, respectively. The zero-dimensional simulations predict that LTHR initiates most likely on the air streamlines before transitioning to HTHR, either on fuel-streamlines or on air-streamlines in regions of near-constant φ. Due to the relatively short pilot-fuel injection-durations, the transient increase in entrainment near the end of injection (entrainment wave) is important for quickly creating auto-ignitable mixtures. To achieve desired combustion characteristics, e.g., multiple ignition-kernels and favorable combustion phasing and location (e.g., for reducing wall heat-transfer or optimizing charge stratification), adjusting injection parameters could tailor mixing trajectories to offset changes in fuel ignition chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗