Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The X-ray spectra of cluster cooling flows. I - Optically thin models

Calculations are carried out of optically thin X-ray spectra for a set of theoretical cluster cooling flow models including homogeneous models and flows with strong gas loss. Integrated X-ray properties for the models are presented, together with surface brightness profiles, aperture luminosities, and line profiles for a representative set of X-ray lines. It is found that models with gas loss have lower total X-ray luminosities than homogeneous models by a factor of 1.35 or less.

Wise, Michael W.↗

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Results from an initial series of experiments and analyses performed at the Positron Imaging Centre (PIC) located at the University of Birmingham, UK, will be presented. Discussion will also cover preliminary, on-going, activities associated with assessing the utility of PET technology in zero-gravity propellant gauging, ionization efficiency characterization in electric propulsion devices, and broader industrial applications.

PET↗

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Preliminary results from on going simulations and analyses will be presented.

Bruggemann, Jeremy↗

Gait Training Improves Performance in Healthy Adults Exposed to Novel Discordant Conditions

After they return to Earth, astronauts experience sensorimotor disturbances that disrupt their ability to walk. We have previously shown that training with a variety of sensorimotor adaptive challenges enhances the capability of adapting to novel sensorimotor conditions. We are currently developing a sensorimotor adaptability (SA) training program designed to facilitate recovery of function after gravitational transitions. The purpose of this study was to determine whether trained subjects could transfer learned skills from one discordant visuo-proprioceptive environment to another. During three sessions, subjects walked at 2.5 km/h on a treadmill mounted on a motion base platform. Ten subjects trained with a combination of lateral treadmill translation and superimposed sinusoidal lateral optic flow that was presented on a large screen positioned in front of them. Ten controls completed the same training schedule while viewing only the forward optic flow with no visual or physical oscillation. Twenty minutes after the final training session, all subjects completed a 2-minute trial with a novel combination of visual and treadmill roll perturbations not previously experienced during the training (Transfer Test). Compared to the untrained group, participants who received SA training showed faster reaction times and, based on a composite score derived from stride frequency, heart rate, and reaction time, an overall enhanced performance. Our results showed that an SA training program can improve overall walking performance when subjects are exposed to novel incongruent sensory environments. This training has application for both enhancing adaptive responses in astronauts and reducing fall and injury risk in the elderly.

Batson, Crystal D.↗

Optical Flow-Field Techniques Used for Measurements in High-Speed Centrifugal Compressors

The overall performance of a centrifugal compressor depends on the performance of the impeller and diffuser as well as on the interactions occurring between these components. Accurate measurements of the flow fields in each component are needed to develop computational models that can be used in compressor design codes. These measurements must be made simultaneously over an area that covers both components so that researchers can understand the interactions occurring between the two components. Optical measurement techniques are being used at the NASA Lewis Research Center to measure the velocity fields present in both the impeller and diffuser of a 4:1 pressure ratio centrifugal compressor operating at several conditions ranging from design flow to surge. Laser Doppler Velocimetry (LDV) was used to measure the intrablade flows present in the impeller, and the results were compared with analyses obtained from two three-dimensional viscous codes. The development of a region of low throughflow velocity fluid within this high-speed impeller was examined and compared with a similar region first observed in a large low-speed centrifugal impeller at Lewis. Particle Image Velocimetry (PIV) is a relatively new technique that has been applied to measuring the diffuser flow fields. PIV can collect data rapidly in the diffuser while avoiding the light-reflection problems that are often encountered when LDV is used. The Particle Image Velocimeter employs a sheet of pulsed laser light that is introduced into the diffuser in a quasi-radial direction through an optical probe inserted near the diffuser discharge. The light sheet is positioned such that its centerline is parallel to the hub and shroud surfaces and such that it is parallel to the diffuser vane, thereby avoiding reflections from the solid surfaces. Seed particles small enough to follow the diffuser flow are introduced into the compressor at an upstream location. A high-speed charge-coupled discharge (CCD) camera is synchronized to the laser pulse rate; this allows it to capture images of seed particle position that are separated by a small increment in time. A crosscorrelation of a particle's position in two consecutive images provides an estimate of flow velocity and direction. Multiple image pairs obtained in rapid succession at a particular flow condition provide enough measurements for statistical significance. PIV provides simultaneous velocity measurements over the entire plane that is illuminated by the light sheet instead of at a single point, as is the case when LDV is used. PIV has a further advantage in that the laser light pulse can be triggered by an external source such as a high-response pressure transducer. This feature will allow PIV to synchronize flow imaging to physical phenomena such as rotating stall or stall precursor waves. We hope that this technique can be used to obtain images of the flow field during and just prior to stall.

Skoch, Gary J.↗

Inertial navigation sensor integrated obstacle detection system

A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.

Bhanu, Bir↗

Detection of obstacles on runway using Ego-Motion compensation and tracking of significant features

This report describes a method for obstacle detection on a runway for autonomous navigation and landing of an aircraft. Detection is done in the presence of extraneous features such as tiremarks. Suitable features are extracted from the image and warping using approximately known camera and plane parameters is performed in order to compensate ego-motion as far as possible. Residual disparity after warping is estimated using an optical flow algorithm. Features are tracked from frame to frame so as to obtain more reliable estimates of their motion. Corrections are made to motion parameters with the residual disparities using a robust method, and features having large residual disparities are signaled as obstacles. Sensitivity analysis of the procedure is also studied. Nelson's optical flow constraint is proposed to separate moving obstacles from stationary ones. A Bayesian framework is used at every stage so that the confidence in the estimates can be determined.

Kasturi, Rangachar↗

Multirate and event-driven Kalman filters for helicopter flight

A vision-based obstacle detection system that provides information about objects as a function of azimuth and elevation is discussed. The range map is computed using a sequence of images from a passive sensor, and an extended Kalman filter is used to estimate range to obstacles. The magnitude of the optical flow that provides measurements for each Kalman filter varies significantly over the image depending on the helicopter motion and object location. In a standard Kalman filter, the measurement update takes place at fixed intervals. It may be necessary to use a different measurement update rate in different parts of the image in order to maintain the same signal to noise ratio in the optical flow calculations. A range estimation scheme that accepts the measurement only under certain conditions is presented. The estimation results from the standard Kalman filter are compared with results from a multirate Kalman filter and an event-driven Kalman filter for a sequence of helicopter flight images.

Sridhar, Banavar↗

A commercialized, continuous flow fiber optic sensor for trichloroethylene and haloforms

Purus, Inc. has commercialized a fiber optic chemical sensor using technology developed by Lawrence Livermore National Laboratory and licensed from The University of California. The basis for the sensor is the development of color within a reagent when exposed to an analyte. The sensor consists of an optrode, reagent delivery and recover system, fiber optic transmitter-receiver, controller, and display. Reagent is pumped through the optrode. Analyte diffuses across a gas permeable membrane and reacts with the reagent to form a colored product. The colored product is detected by measuring the absorbance of light from a 568 nm diode. Reagents are currently available for TCE and trihalomethanes. Initial reagent chemistry is based on the Fujiwara alkaline pyridine reaction. The optrode contacts only gas streams, but the volatility of the current analytes also allows measurements of aqueous streams, without being affected by aqueous interferents that are non-volatile. Sensitivity of the sensor has been demonstrated to 5 ppb aqueous solutions and 0.1 ppmv in flowing gas streams.

Wells, James C.↗

Heading perception in patients with advanced retinitis pigmentosa

PURPOSE: We investigated whether retinis pigmentosa (RP) patients with residual visual field of < 100 degrees could perceive heading from optic flow. METHODS: Four RP patients and four age-matched normally sighted control subjects viewed displays simulating an observer walking over a ground. In experiment 1, subjects viewed either the entire display with free fixation (full-field condition) or through an aperture with a fixation point at the center (aperture condition). In experiment 2, patients viewed displays of different durations. RESULTS: RP patients' performance was comparable to that of the age-matched control subjects: heading judgment was better in the full-field condition than in the aperture condition. Increasing display duration from 0.5 s to 1 s improved patients' heading performance, but giving them more time (3 s) to gather more visual information did not consistently further improve their performance. CONCLUSIONS: RP patients use active scanning eye movements to compensate for their visual field loss in heading perception; they might be able to gather sufficient optic flow information for heading perception in about 1 s.

Visual Perception↗

Development of a flow visualization apparatus

The use of an optical flow visualization device for studying convection flow patterns was investigated. The investigation considered use of a shadowgraph, schlieren and other means for visualizing the flow. A laboratory model was set up to provide data on the proper optics and photography procedures to best visualize the flow. A preliminary design of a flow visualization system is provided as a result of the study. Recommendations are given for a flight test program utilizing the flow visualization apparatus.

Spradley, L. W.↗

A miniature electro-optical air flow sensor

Miniature sensors are needed for rapid and uncomplicated installation on light aircraft engaged in stability research programs. One particularly difficult sensor to miniaturize to the required degree has been a flow angle and velocity sensor for measuring the local flow ahead of a wing. However, by using an electrooptical technique it was possible to overcome the encountered difficulties and to design a sensor satisfying the requirements. The developed sensor for measuring angle-of-attack, yaw, and airspeed was shown to be suitable for rapid instrumentation of research aircraft because of its small size. The size reduction was accomplished by a design feature which eliminates the need for slip rings and wiring within the movable components of the sensor.

Kershner, D. D.↗

High speed optical tomography for flow visualization

A novel optical architecture (based on holographic optical elements) for making high speed tomographic measurements is presented. The system is designed for making density or species concentration measurements in a nonsteady fluid or combusting flow. Performance evaluations of the optical system are discussed, and a test phase object has been successfully reconstructed using this optical arrangement.

Snyder, R.↗

High speed optical tomography for flow visualization

A novel optical architecture (based on holographic optical elements) for making high speed tomographic measurements is presented. The system is designed for making density or species concentration measurements in a nonsteady fluid or combustion flow. Performance evaluations of the optical system are discussed, and a test phase object was successfully reconstructed using this optical arrangement.

Snyder, Ray↗

Laser anemometry - Advances and applications 1991; Proceedings of the 4th International Conference, Cleveland, OH, Aug. 5-9, 1991. Vols. 1 & 2

The papers presented in this volume provide an overview of the latest advances in laser anemometry and optical flow diagnostics. Topics discussed include turbulence, jets, and chaos; novel optical techniques for velocity measurements; chemical reactions and combusting flows; and LDA/CFD interface. Attention is also given to particle image velocimetry, high speed flows and aerodynamic flows, internal flows, particle sizing, optics and signal processing, two-phase flows, and general fluid mechanics applications.

Dybbs, Alexander↗

Self-irradiated cooling condensations - The source of the optical line emission from cooling flows

The optical filaments seen at the centers of clusters of galaxies, which cannot be explained by standard photoionization or shock models, can be straightforwardly interpreted as self-irradiated cooling condensations. Fully developed (about 10,000 K) condensations embedded in thermally unstable 10 million K gas will be bathed in a powerful EUV/soft X-ray flux emanating from the surrounding condensing regions. The present models of the condensation/irradiation process give line ratios and luminosities similar to those observed. Because it is assumed that the condensations arise from linear perturbations, which grow significantly only when the local cooling time is less than the free-fall time, condensing regions of the type modeled here should arise only in cooling flows of central pressure less than about 1 billion ergs/cu cm and should extend only over the inner regions of the cluster.

Voit, G. Mark↗