Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Uncertainty analysis of PIV measurements in bubbly flows considering sampling and bubble effects with ray optics modeling

In this report, a modeling-based approach is developed to investigate the external sources of uncertainty in particle image velocimetry (PIV) measurements for two-phase bubbly flows. Primarily relied on ray optics modeling, this study focuses on the uncertainty in PIV measurements due to bubble-induced light distortion. In addition, the uncertainty due to sampling is also considered through synthetic PIV images generated from Monte Carlo sampling. Based on a PIV-planar laser induced florescence (PLIF) measurement system, three case studies are performed and discussed, considering respectively the sampling effect, bubble effect, and the combination of these two effects. These case studies confirm the validity of the ray optics modeling in obtaining accurate particle images through a benchmark test. Furthermore, it is also found that the bubble effect could significantly influence the particle images. On the other hand, the result of the case study with synthetic PIV images indicates that the bubble effect on particle images can be minimized by removing “outliers” in the obtained velocity vector field through a multi-pass post-processing procedure. However, the uncertainty of the velocity measurements will still increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and characterization of “flow-cell” integrated-flow active cooling for high-average-power ceramic optics

We used COMSOL Multiphysics to design a prototype actively cooled “flow-cell” substrate targeted at high-average-power applications, fabricated the prototype from cordierite ceramic, and tested the substrate under load in our thermal loading test stand. Sub-aperture testing revealed average-power handling up to 3.88-W/cm 2 absorbed power density, in excellent agreement with model predictions. Gratings fabricated on 2-in.-diam cordierite coupons were subjected to laser-damage testing and showed a damage threshold of 250 mJ/cm 2 .

47 OTHER INSTRUMENTATION↗

Quantitative local state of charge mapping by operando electrochemical fluorescence microscopy in porous electrodes

We introduce operando quantitative electrochemical fluorescence state of charge mapping (QEFSM), a non-invasive technique to study operating electrochemical systems along with a new design of optically transparent microfluidic redox flow cells compatible with the most demanding optical requirements. QEFSM allows quantitative mappings of the concentration of a particular oxidation state of a redox-active species within a porous electrode during its operation. In this study, we used confocal microscopy to map the fluorescence signal of the reduced form of 2,7-anthraquinone disulfonate (AQDS) in a set of multistep-chronoamperometry experiments. Calibrating these images and incorporating an analytical model of quinhydrone heterodimer formation with no free parameters, and accounting for the emission of each species involved, we determined the local molecular concentration and the state of charge (SOC) fields within a commercial porous electrode during operation. With this method, electrochemical conversion and species advection, reaction and diffusion can be monitored at heretofore unprecedented transverse and axial resolution (1 μm and 25 μm, respectively) at frame rates of 0.5 Hz, opening new routes to understanding local electrochemical processes in porous electrodes. Here, we observed pore-scale SOC inhomogeneities appearing when the fraction of electroactive species converted in a single pass through the electrode becomes large.

42 ENGINEERING↗

Probing local electron temperature and density inside a sheared flow stabilized Z-pinch using portable optical Thomson scattering

We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 10 16 cm –3 ) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 10 17 cm –3 to several 10 19 cm –3 and electron temperatures from tens of eV to several keV. Here, in this paper, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 10 16 cm –3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.

47 OTHER INSTRUMENTATION↗

Comparing Global Spray Combustion Characteristics and Local Shot-to-Shot Variations in a Reacting n -Heptane Spray

In support of efforts to develop improved models of turbulent spray behavior and combustion in diesel engines, experimental data and analysis must be obtained for guidance and validation. For Reynolds-averaged Navier–Stokes (RANS)-based Computational fluid dynamics (CFD) modeling approaches, representative ensemble average experimental results are important. For high-fidelity models such as large eddy simulations (LES)-based CFD, precise individual experimental results are desirable. However, making comparisons between a given experiment and LES is a challenge since local parameters cannot be directly compared. In this work, an optically accessible constant pressure flow rig (CPFR) is utilized to acquire diesel-like fuel injection and reaction behavior simultaneously with three optical diagnostic techniques: rainbow Schlieren deflectometry (RSD), OH* chemiluminescence (OH*), and two-color pyrometry (2CP). The CPFR allows a large number of repeated injection experiments to be performed for statistical analysis and convergence using ensemble-averaging techniques, while maintaining highly repeatable test conditions. Even for stable test conditions, variations in local turbulent fuel–air mixing introduce variability, which manifests as significant differences in OH* and 2CP results. Experimental measurements of characteristic parameters including liquid and vapor jet penetration, liftoff length, soot temperature and concentration, and turbulent flame speed, along with the shot-to-shot variability of each dataset, are presented and discussed. Finally, a statistical method is utilized to analyze the extent of this variability, and to identify superlative injections within the dataset for discussion and analysis of shot-to-shot variations.

42 ENGINEERING↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Electron Heating in the Transrelativistic Perpendicular Shocks of Tilted Accretion Flows

Abstract General relativistic magnetohydrodynamic (GRMHD) simulations of black hole tilted disks—where the angular momentum of the accretion flow at large distances is misaligned with respect to the black hole spin—commonly display standing shocks within a few to tens of gravitational radii from the black hole. In GRMHD simulations of geometrically thick, optically thin accretion flows, applicable to low-luminosity sources like Sgr A* and M87*, the shocks have transrelativistic speed, moderate plasma beta (the ratio of ion thermal pressure to magnetic pressure is β pi1 ∼ 1–8), and low sonic Mach number (the ratio of shock speed to sound speed is M s ∼ 1–6). We study such shocks with 2D particle-in-cell simulations, and we quantify the efficiency and mechanisms of electron heating for the special case of preshock magnetic fields perpendicular to the shock direction of propagation. We find that the postshock electron temperature T e2 exceeds the adiabatic expectation T e2,ad by an amount T e 2 / T e 2 , ad − 1 ≃ 0.0016 M s 3.6 , nearly independent of the plasma beta and of the preshock electron-to-ion temperature ratio T e1 / T i1 , which we vary from 0.1 to unity. We investigate the heating physics for M s ∼ 5–6 and find that electron superadiabatic heating is governed by magnetic pumping at T e1 / T i1 = 1, whereas heating by B -parallel electric fields (i.e., parallel to the local magnetic field) dominates at T e1 / T i1 = 0.1. Our results provide physically motivated subgrid prescriptions for electron heating at the collisionless shocks seen in GRMHD simulations of black hole accretion flows.

Astronomy & Astrophysics↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Different Kinetic Reactivities of Electrons in Distinct TiO 2 Nanoparticle Trap States

Electrons added to TiO 2 and other semiconductors often occupy trap states, whose reactivity can determine the catalytic and stoichiometric chemistry of the material. We previously showed that reduced aqueous colloidal TiO 2 nanoparticles have two distinct classes of thermally equilibrated trapped electrons, termed Red/e – and Blue/e – . Presented here are parallel optical and electron paramagnetic resonance (EPR) kinetic studies of the reactivity of these electrons with solution-based oxidants. Optical stopped-flow measurements monitoring the reactions of TiO 2 /e – with substoichiometric oxidants showed a surprising pattern: an initial fast (seconds) decrease in TiO 2 /e – absorbance followed by a secondary, slow (minutes) increase in the broad TiO 2 /e – optical feature. The analysis revealed that the fast decrease is due to the preferential oxidation of the Red/e – trap states and the slow increase results from the re-equilibration of electrons from Blue/e - to Red/e - states. This kinetic model was confirmed by freeze-quench EPR measurements. Quantitative analysis of the kinetic data demonstrated that Red/e – react ~5 times faster than Blue/e – with the nitroxyl radical oxidant 4-methoxy-2,2,6,6-tetramethyl-1-piperidinyloxyl (4-MeO-TEMPO). Similar reactivity patterns were also observed in oxidations of TiO 2 /e – by O 2 , which like 4-MeO-TEMPO is a proton-coupled electron transfer (PCET) oxidant, and by the pure electron transfer (ET) oxidant potassium triiodide (KI 3 ). Furthermore, this suggests that the faster intrinsic reactivity of one trap state over another on the seconds–minutes time scale is likely a general feature of reduced TiO 2 reactivity. This differential trap-state reactivity is likely to influence the performance of TiO 2 in photochemical/electrochemical devices, and it suggests an opportunity for tuning catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined visualisation of cavitation and vortical structures in a real-size optical diesel injector

A high-speed flow visualisation set-up comprising of combined diffuse backlight illumination (DBI) and schlieren imaging has been developed to illustrate the highly transient, two-phase flow arising in a real-size optical fuel injector. The different illumination nature of the two techniques, diffuse and parallel light respectively, allows for the capturing of refractive-index gradients due to the presence of both interfaces and density gradients within the orifice. Hence, the onset of cavitation and secondary-flow motion within the sac and injector hole can be concurrently visualised. Experiments were conducted utilising a diesel injector fitted with a single-hole transparent tip (ECN spray D) at injection pressures of 700–900 bar and ambient pressures in the range of 1–20 bar. High-speed DBI images obtained at 100,000 fps revealed that the orifice, due to its tapered layout, is mildly cavitating with relatively constant cavity sheets arising mainly in regions of manufacturing imperfections. Nevertheless, schlieren images obtained at the same frame rate demonstrated that a multitude of vortices with short lifetimes arise at different scales in the sac and nozzle regions during the entire duration of the injection cycle but the vortices do not necessarily result in phase change. The magnitude and exact location of coherent vortical structures have a measurable influence on the dynamics of the spray emerging downstream the injector outlet, leading to distinct differences in the variation of its cone angle depending on the injection and ambient pressures examined.

42 ENGINEERING↗

Control of liquid crystals combining surface acoustic waves, nematic flows, and microfluidic confinement

The optical properties of liquid crystals serve as the basis for display, diagnostic, and sensing technologies. Such properties are generally controlled by relying on electric fields. In this work, we investigate the effects of microfluidic flows and acoustic fields on the molecular orientation and the corresponding optical response of nematic liquid crystals. Several previously unknown structures are identified, which are rationalized in terms of a state diagram as a function of the strengths of the flow and the acoustic field. The new structures are interpreted by relying on calculations with a free energy functional expressed in terms of the tensorial order parameter, using continuum theory simulations in the Landau-de Gennes framework. Taken together, the findings presented here offer promise for the development of new systems based on combinations of sound, flow, and confinement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Cascade Dielectrophoretic Separation for Selective Enrichment of Polyhydroxybutyrate (PHB)-Producing Cyanobacterium Synechocystis sp. PCC 6803

Maintaining favorable biological productivities in photosynthetic biomanufacturing systems, especially when the risk of contamination with competing microbes is high, remains a challenge to achieve while maintaining economic feasibility. This study presents a dielectrophoresis (DEP)-based microfluidic approach for isolating a desired strain within a co-culture. The cyanobacterium Synechocystis sp. PCC 6803 (a strain capable of producing the bioplastic precursor polyhydroxybutyrate, or PHB) was enriched from mixed cultures containing the competing cyanobacterium Synechococcus elongatus PCC 7942 (which does not naturally produce PHB). A DEP cascade electrode system was established to increase purification efficiency through sequential enrichment, which leveraged inherent differences in cell morphology and dielectric properties, to achieve the selective separation of these strains under physiological conditions. A substantial increase in the relative abundance of PHB-producing cells was assessed by optical microscopy and flow cytometry characterization, confirming more than five-fold reduction of the Synechococcus fraction in the refined cell mix. The presented electrokinetic platform offers a scalable and effective approach for selectively enhancing desired microbial components within microbial biomanufacturing systems, leading towards improved product yields.

60 APPLIED LIFE SCIENCES↗