Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Wind Tunnel PSD and MVD Characterization Using New 1D2D Optical Array Probes

This work explores characterization of the liquid clouds using a combination of a forward scattering probe and two Optical Array Probes. Current OAP probes provide particle shape, size, and number concentration from two-dimensional shadow images. However, past studies have shown that such images are subject to distortion when outside of the focal plane. This affects the retrieval of particle size distributions, particularly in the Supercooled Large Droplet size range. In this article, the use of a Droplet Measurement Technologies Cloud Droplet Probe and two new OAPs produced by Science Engineering Associates, is examined using wind tunnel data, to assess suitability for use in a wind tunnel calibration in SLD conditions. The new OAP probes exploit a flexible and simple grey scale imaging method to eliminate some present shortcomings of commonly used OAPs, and to reduce correction factors. Spinning disk measurements were used to specify probe depth of field, and average size errors. Composite spectra covering the nominal 2-3200 µm size range were formed by crossing over from the CDP to 1D2D-X at 48 µm, and then to the 1D2D-Y at about 400 µm. A good overlap was found at the crossover points without any artificial scaling. Composite spectra adequately closed the liquid water content distribution, and provided integrated LWCs within about 35% of the hot-wire LWCs used for tunnel calibration. This discrepancy was at least partially attributed to LWC underestimation by the hot-wire at high MVD. A model of probe performance was used to show an example of expected accuracy of ideal probes subject to the same OAP distortions and using the same mitigating procedures and corrections, predicting PSD Median Volume Diameter and integrated LWC errors of less than 10%.

Aircraft Icing↗

Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

near grid plasma↗

Advanced Optical Cavity Probes

Presentation describes evolution of optical cavity probe design since 2010, with probe designs getting smaller and adding more beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning for Optical Scanning Probe Nanoscopy

Abstract The ability to perform nanometer‐scale optical imaging and spectroscopy is key to deciphering the low‐energy effects in quantum materials, as well as vibrational fingerprints in planetary and extraterrestrial particles, catalytic substances, and aqueous biological samples. These tasks can be accomplished by the scattering‐type scanning near‐field optical microscopy (s‐SNOM) technique that has recently spread to many research fields and enabled notable discoveries. Herein, it is shown that the s‐SNOM, together with scanning probe research in general, can benefit in many ways from artificial‐intelligence (AI) and machine‐learning (ML) algorithms. Augmented with AI‐ and ML‐enhanced data acquisition and analysis, scanning probe optical nanoscopy is poised to become more efficient, accurate, and intelligent.

Chen, Xinzhong↗

Fiber-Optic Imaging Probe Developed for Space Used to Detect Diabetes Through the Eye

Approximately 16 million Americans have diabetes mellitus, which can severely impair eyesight by causing cataracts, diabetic retinopathy, and glaucoma. Cataracts are 1.6 times more common in people with diabetes than in those without diabetes, and cataract extraction is the only surgical treatment. In many cases, diabetes-related ocular pathologies go undiagnosed until visual function is compromised. This ongoing pilot project seeks to study the progression of diabetes in a unique animal model by monitoring changes in the lens with a safe, sensitive, dynamic light-scattering probe. Dynamic light scattering (DLS), has the potential to diagnose cataracts at the molecular level. Recently, a new DLS fiber-optic probe was developed at the NASA Glenn Research Center at Lewis Field for noncontact, accurate, and extremely sensitive particle-sizing measurements in fluid dispersions and suspensions (ref. 1). This compact, portable, and rugged probe is free of optical alignment, offers point-and-shoot operation for various online field applications and challenging environments, and yet is extremely flexible in regards to sample container sizes, materials, and shapes. No external vibration isolation and no index matching are required. It can measure particles as small as 1 nm and as large as few micrometers in a wide concentration range from very dilute (waterlike) dispersions to very turbid (milklike) suspensions. It is safe and fast to use, since it only requires very low laser power (10 nW to 3 mW) with very short data acquisition times (2 to 10 sec).

Ansari, Rafat R.↗

Probing Local Optical Fields via Ultralow Frequency Raman Scattering from a Corrugated Probe

Here we revisit nanoscale local optical field imaging via tip-enhanced Raman scattering (TERS). Rather than taking advantage of molecular reporters to probe different aspects of the local fields, we show how ultralow frequency Raman (ULF) scattering from the (nano-corrugated) metallic probe itself can be used for the same purpose. The bright ULF-TERS response we record allows non-invasive (tapping mode feedback) local field imaging, enables visualizing the local fields of small (down to 20 nm) isolated plasmonic particles, and can also be exploited to distinguish between Si and SiO2 domains with 5 nm spatial resolution. We describe our approach and its limitations, particularly when it comes to using all-metallic vs molecular reporters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flight testing of a fiber optic temperature sensor

A fiber optic temperature sensor (FOTS) system consisting of an optical probe, a flexible fiber optic cable, and an electro-optic signal processor was fabricated to measure the gas temperature in a turbine engine. The optical probe contained an emissive source embedded in a sapphire lightguide coupled to a fiber-optic jumper cable and was retrofitted into an existing thermocouple probe housing. The flexible fiber optic cable was constructed with 200 micron core, polyimide-coated fiber and was ruggedized for an aircraft environment. The electro-optic signal processing unit was used to ratio the intensities of two wavelength intervals and provided an analog output value of the indicated temperature. Subsequently, this optical sensor system was installed on a NASA Dryden F-15 Highly Integrated Digital Electronic Control (HIDEC) Aircraft Engine and several flight tests were conducted. Over the course of flight testing, the FOTS system's response was proportional to the average of the existing thermocouples sensing the changes in turbine engine thermal conditions.

Finney, M. J.↗

Integrated Fiber-Optic Light Probe: Measurement of Static Deflections in Rotating Turbomachinery

At the NASA Lewis Research Center, in cooperation with Integrated Fiber Optic Systems, Inc., an integrated fiber-optic light probe system was designed, fabricated, and tested for monitoring blade tip deflections, vibrations, and to some extent, changes in the blade tip clearances of a turbomachinery fan or a compressor rotor. The system comprises a set of integrated fiber-optic light probes that are positioned to detect the passing blade tip at the leading and trailing edges. In this configuration, measurements of both nonsynchronous blade vibrations and steady-state blade deflections can be made from the timing information provided by each light probe-consisting of an integrated fiber-optic transmitting channel and numerical aperture receiving fibers, all mounted in the same cylindrical housing. With integrated fiber-optic technology, a spatial resolution of 50 mm is possible while the outer diameter is kept below 2.5 mm. To evaluate these probes, we took measurements in a single-stage compressor facility and an advanced fan rig in Lewis' 9- by 15-Foot Low-Speed Wind Tunnel.

Kurkov, Anatole P.↗

The optical and probe measurement of NO - A comparative study

Measurements were made of NO formation in both subsonic turbulent and nonturbulent media generated from gaseous and liquid fuels. Quartz and metallic, cooled and uncooled probes were employed, and optical measurements were made in the UV with narrow-line and continuum lamps. The extent of systematic error bias in these methods was studied over a wide range of conditions. High resolution measurements were made only on flat flames using a high pressure Xe lamp, while low resolution measurements were done with a hollow cathode lamp on flat flame, swirl burner and jet combustor exhausts. Optical data were reduced using a first principles spectral model and multiple zone treatment of the optical path. No major discrepancies related to processes occurring in probes were identified. Good agreement can be expected in measurements made in subsonic exhaust streams up to 2000 K.

Zabielski, M. F.↗

Pressure-Measuring Diaphragm Transmits Optical Signals

Proposed sapphire diaphragm performs two functions in instrumented research engine or pressure vessel. Serves both as pressure sensor and as window for observation, optical probing, or optical transmission of other measurements. Deflections of sapphire diaphragm alters resistances of strain gauges mounted around its periphery. At same time, transparent material enables optical measurements of conditions in chamber. Additional information obtained about conditions in chamber without need for additional sensor mounts.

Hill, Arthur J.↗

Flight Plasma Diagnostics for High-Power, Solar-Electric Deep-Space Spacecraft

NASA’s Asteroid Redirect Robotic Mission (ARRM) mission concept plans included a set of plasma and space environment instruments, the Plasma Diagnostic Package (PDP), to fulfill ARRM requirements for technology extensibility to future missions. The PDP objectives were divided into the classes of 1) Plasma thruster dynamics, 2) Solar array-specific environmental effects, 3) Plasma environmental spacecraft effects, and 4) Energetic particle spacecraft environment. A reference design approach and interface requirements for ARRM’s PDP was generated by the PDP team at JPL and GRC. The reference design consisted of redundant single-string avionics located on the ARRM spacecraft bus as well as solar array, driving and processing signals from multiple copies of several types of plasma, effects, and environments sensors distributed over the spacecraft and array. The reference design sensor types were derived in part from sensors previously developed for USAF Research Laboratory (AFRL) plasma effects campaigns such as those aboard TacSat-2 in 2007 and AEHF-2 in 2012. ARRM project leadership also encouraged the PDP team to convene a team of topical subject matter experts from across the country to review and confirm the reference design and to consider effective alternatives and/or enhancements to the reference design. This activity was proposed and accepted as an interactive, informal JPL “A-team” study and a cadre of 25 participants gathered in early 2017 for discussions. The outcome of the two-day A-team study was that the PDP reference design would allow the most important induced-environment unknowns to be measured in the appropriate space environment. Another outcome addressed technology developments of new or improved space plasma environmental sensors. The A-team study concluded that selected developments would lead to improved measurements that could efficiently provide important and otherwise unavailable information about plasma thruster operation in the space environment as well as the plasma induced spacecraft environment. Specifically, the A-team group recommended greater sensor diversity, by inclusion of deployed sensor capabilities in the thruster plume, or by occasional gimbaling of the thruster(s) toward the sensor arrays. The A-team also recommended developing high-speed probes, optical plasma probes, energy selective probes, and direct erosion/deposition sensors, among others; and recommended the inclusion of cameras as well as, since ARRM was to be recovered in cis-lunar orbit by a crewed mission, astronaut assessments of thruster induced environments and collection of sample coupons. Overall, the PDP A-team study provided a clear, consensus supported validation of the reference design PDP approach and pointed out important directions for future flight plasma sensor development.

Choi, Maria↗

Fiber optic detector probes for laser light scattering

An experimental investigation of the role of fiber optic detector probes in laser light scattering is presented. A quantitative comparison between different detector configurations is accomplished by measuring the time taken for one million photocounts to be accumulated in the extrapolated zeroth delay channel of the net unnormalized intensity time correlation function. A considerable reduction in the accumulation time is achieved by relaxing a rather stringent requirement for the spatial coherence of the optical field.

Dhadwal, Harbans S.↗

Optical Spectroscopic Probes of Degradation and Metastability in Polycrystalline (Ag,Cu)(In,Ga)Se2 Absorbers

We employ optical spectroscopic probes, based on steady-state photoluminescence (SSPL) and time-resolved photoluminescence (TRPL) excitation spectroscopy to spatially and energetically resolve metastable defects in polycrystalline (Ag,Cu)(In,Ga)Se 2 (ACIGS) absorbers. First, we show that ACIGS has similar potential fluctuations as CIGS; that is alloying with Ag does not result in significant changes in the electronic disorder. We subsequently demonstrate that optical spectroscopy is able to identify metastable defects states in ACIGS, the nature of which is subtly modified by dark-heat degradation. These defects are converted into minority carrier lifetime-limiting recombination states upon light-soaking under 1 Sun illumination for 24 hours. We identify the activation energy for thermal emission from trap states near the front surface of the ACIGS absorber. Finally, variation of the excitation wavelength reveals the depth distribution of the shallow defects. We tentatively ascribe the defects to complexes that include Se-vacancies.

14 SOLAR ENERGY↗

Advance optical fiber probe for simultaneous measurements of solids holdup and particles velocity using simple calibration methods for gas-solid fluidization systems

We report advanced gas-solid optical fiber probe technique that can measure simultaneously solids velocity, solids concentration related quantity, and their time series fluctuations has been implemented with simple and new calibration methods for both solids holdup and particles velocity measurements in gas-solid spouted bed and gas-solid fluidized bed. The needed signal and data processing programs have been developed in our laboratory. New, simple, and reliable calibration methods and the related experimental setups have been established to convert the solids concentration related signal to solids holdup which is a meaningful hydrodynamic parameter and to determine the effective distance between the two tips of the probe for the solids velocity measurements. The new calibration methods have been employed to cover a wide range of particle sizes which usually used in gas-solid spouted beds and gas-solid fluidized beds. Selected results have demonstrated the appropriateness of the advanced optical fiber in measuring both solids holdup and particles velocity in the experimental setups of the gas-solid spouted and fluidized beds. The measurements have been compared against independent techniques of gamma ray computed tomography (CT) and radioactive particle tracking (RPT).

42 ENGINEERING↗

Optical and Probe Diagnostics Applied to Reacting Flows

The general theme of the research my NASA colleague and I have planned is "Optical and probe diagnostics applied to reacting flows". We plan to explore three major threads during the fellowship period. The first interrogates the flame synthesis of carbon nanotubes using aerosol catalysts. Having demonstrated the viability of the technique for nanotube synthesis, we seek to understand the details of this reacting system which are important to its practical application. Laser light scattering will reveal changes in particle size at various heights above the burner. Analysis of the flame gas by mass spectroscopy will reveal the chemical composition of the mixture. Finally, absorption measurements will map the nanotube concentration within the flow. The second thread explores soot oxidation kinetics. Despite the impact of soot on engine performance, fire safety and pollution, models for its oxidation are inhibited by uncertainty in the values of the oxidation rate. We plan to employ both optical and microscopic measurements to refine this rate. Cavity ring-down absorption measurements of the carbonaceous aerosol can provide a measure of the mass concentration with time and, hence, an oxidation rate. Spectroscopic and direct probe measurements will provide the temperature of the system needed for subsequent modeling. These data will be benchmarked against changes in soot nanostructures as revealed by transmission electron microscopic images from directly sampled material.

Ticich, Thomas M.↗

Prediction of spout diameter in gas-solid spouted beds using factorial design of experiments approach with the aid of advanced optical fibre probe

In this study, the effects of five operating and design variables (solid density, static bed height, particle diameter, superficial gas velocity, and inlet diameter) on the average spout diameter of a 0.152 m inside diameter gas-solid spouted bed have been assessed experimentally using advanced gas-solid optical fibre probe technique. Statistical analysis of the experimental data including the factorial design of the experiments using MINITAB17 statistical software has been performed to determine the extent of the effects of these variables on the spout diameter as a case study. It was found that all five operating and design variables, except the solid density together with the 2-ways interactions between particles size and inlet diameter, in addition to gas velocity and inlet diameter, have a significant effect on the average spout diameter. Regression analysis was performed to correlate these variables with the average spout diameter for the gas-solid spouted beds. The obtained preliminary regression correlation was able to closely predict the average spout diameter of this work with the mean relative deviation value of 0.7 %.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fiber-Optic Raman Probe for On-line EAF Slag Analysis

Here, in Electric Arc Furnace (EAF) steelmaking, the push for improved efficiency requires accurate analysis of the chemical composition of its slag system to control slag foaming, provide refractory protection, and maintain high furnace iron yield. Therefore, the ability to obtain real-time slag chemistry data would provide a useful tool to improve the control and efficiency of the process. The work reported here aims to assess the structure and chemistry of EAF slags at high temperatures using a portable fiber-optic Raman probe. As a result, the ability to relate Raman spectra peaks to chemistry and structure is demonstrated in experimental result with EAF slags at 1550°C.

47 OTHER INSTRUMENTATION↗

Fiber optic temperature sensor

A temperature sensor has been developed that utilizes the temperature dependent absorption of a rare earth doped optical fiber. The temperature measurement is localized at a remote position by splicing a short section of the rare earth fiber into a loop of commercial data communication fiber that sends and returns an optical probe signal to the temperature sensitive section of fiber. The optical probe signal is generated from two different wavelength filtered LED sources. A four port fiber optic coupler combines the two separate wavelength signals into the fiber sensing loop. Time multiplexing is used so that each signal wavelength is present at a different time. A reference signal level measurement is also made from the LED sources and a ratio taken with the sensor signal to produce a transmission measurement of the fiber loop. The transmission is affected differently at each wavelength by the rare earth temperature sensitive fiber. The temperature is determined from a ratio of the two transmission measurements. This method eliminates any ambiguity with respect to changes in signal level in the fiber loop such as mating and unmating optical connectors. The temperature range of the sensor is limited to about 800 C by the temperature limit fo the feed fibers.

Morey, W. W.↗