At least 73 records · Page 4

Probing Local Optical Fields via Ultralow Frequency Raman Scattering from a Corrugated Probe

Here we revisit nanoscale local optical field imaging via tip-enhanced Raman scattering (TERS). Rather than taking advantage of molecular reporters to probe different aspects of the local fields, we show how ultralow frequency Raman (ULF) scattering from the (nano-corrugated) metallic probe itself can be used for the same purpose. The bright ULF-TERS response we record allows non-invasive (tapping mode feedback) local field imaging, enables visualizing the local fields of small (down to 20 nm) isolated plasmonic particles, and can also be exploited to distinguish between Si and SiO2 domains with 5 nm spatial resolution. We describe our approach and its limitations, particularly when it comes to using all-metallic vs molecular reporters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of Ar/CL2 plasma parameters used for SRF cavity etching

We are pursuing the development of environmentally friendly dry etching of superconducting radio frequency (SRF) cavities in Ar/CL2 discharges. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after plasma etchings are equal to or better than wet etching processes. The plasma properties inside the single cell SRF cavity depend significantly on frequency, pressure and power. To understand the plasma properties and chemical kinetics of plasma etching process inside a single cell cavity, we are using a specially-designed cavity with 20 sample holders symmetrically distributed over the cell. These holders are being used for niobium coupon etching as well as diagnostic ports for optical measurements. Multiple optical probes with optical fibers have been utilized for emission spectroscopy measurements. A power supply in the radio frequency regime (100 MHz) and another power supply in the microwave frequency regime (2.45 GHz) are used to produce plasma inside the cavity. The plasma parameters at different pressures and power levels in combination with the analysis of the niobium sample etched will be used to determine the adequate frequency regime for plasma etching of Nb cavities.

Upadhyay, J.↗

Atomic force microscopy deep trench and sidewall imaging with an optical fiber probe

We report a method to measure critical dimensions of micro- and nanostructures using the atomic force microscope (AFM) with an optical fiber probe (OFP). This method is capable of scanning narrow and deep trenches due to the long and thin OFP tip, as well as imaging of steep sidewalls with unique profiling possibilities by laterally tilting the OFP without any modifications of the optical lever. A switch control scheme is developed to measure the sidewall angle by flexibly transferring feedback control between the Z- and Y-axis, for a serial scan of the horizontal surface (raster scan on XY-plane) and sidewall (raster scan on the YZ-plane), respectively. In experiments, a deep trench with tapered walls (243.5 μm deep) and a microhole (about 14.9 μm deep) have been imaged with the orthogonally aligned OFP, as well as a silicon sidewall (fabricated by deep reactive ion etching) has been characterized with the tilted OFP. Moreover, the sidewall angle of TGZ3 (AFM calibration grating) was accurately measured using the switchable scan method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Spectroscopic Probes of Degradation and Metastability in Polycrystalline (Ag,Cu)(In,Ga)Se2 Absorbers

We employ optical spectroscopic probes, based on steady-state photoluminescence (SSPL) and time-resolved photoluminescence (TRPL) excitation spectroscopy to spatially and energetically resolve metastable defects in polycrystalline (Ag,Cu)(In,Ga)Se 2 (ACIGS) absorbers. First, we show that ACIGS has similar potential fluctuations as CIGS; that is alloying with Ag does not result in significant changes in the electronic disorder. We subsequently demonstrate that optical spectroscopy is able to identify metastable defects states in ACIGS, the nature of which is subtly modified by dark-heat degradation. These defects are converted into minority carrier lifetime-limiting recombination states upon light-soaking under 1 Sun illumination for 24 hours. We identify the activation energy for thermal emission from trap states near the front surface of the ACIGS absorber. Finally, variation of the excitation wavelength reveals the depth distribution of the shallow defects. We tentatively ascribe the defects to complexes that include Se-vacancies.

14 SOLAR ENERGY↗

Few-cycle optical probe-pulse for investigation of relativistic laser-plasma interactions

The development of a few-cycle optical probe-pulse for the investigation of laser-plasma interactions driven by a Ti:sapphire, 30 Terawatt (TW) laser system is described. The probe is seeded by a fraction of the driving laser's energy and is spectrally broadened via self-phase modulation in a hollow core fiber filled with a rare gas, then temporally compressed to a few optical cycles via chirped mirrors. Shadowgrams of the laser-driven plasma wave created in relativistic electron acceleration experiments are presented with few-fs temporal resolution, which is shown to be independent of post-interaction spectral filtering of the probe-beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advance optical fiber probe for simultaneous measurements of solids holdup and particles velocity using simple calibration methods for gas-solid fluidization systems

We report advanced gas-solid optical fiber probe technique that can measure simultaneously solids velocity, solids concentration related quantity, and their time series fluctuations has been implemented with simple and new calibration methods for both solids holdup and particles velocity measurements in gas-solid spouted bed and gas-solid fluidized bed. The needed signal and data processing programs have been developed in our laboratory. New, simple, and reliable calibration methods and the related experimental setups have been established to convert the solids concentration related signal to solids holdup which is a meaningful hydrodynamic parameter and to determine the effective distance between the two tips of the probe for the solids velocity measurements. The new calibration methods have been employed to cover a wide range of particle sizes which usually used in gas-solid spouted beds and gas-solid fluidized beds. Selected results have demonstrated the appropriateness of the advanced optical fiber in measuring both solids holdup and particles velocity in the experimental setups of the gas-solid spouted and fluidized beds. The measurements have been compared against independent techniques of gamma ray computed tomography (CT) and radioactive particle tracking (RPT).

42 ENGINEERING↗

The time resolved measurement of ultrashort terahertz-band electric fields without an ultrashort probe

The time-resolved detection of ultrashort pulsed THz-band electric field temporal profiles without an ultrashort laser probe is demonstrated. A non-linear interaction between a narrow-bandwidth optical probe and the THz pulse transposes the THz spectral intensity and phase information to the optical region, thereby generating an optical pulse whose temporal electric field envelope replicates the temporal profile of the real THz electric field. This optical envelope is characterised via an autocorrelation based FROG (frequency resolved optical gating) measurement, hence revealing the THz temporal profile. The combination of a narrow-bandwidth, long duration, optical probe, and self-referenced FROG makes the technique inherently immune to timing jitter between the optical probe and THz pulse and may find particular application where the THz field is not initially generated via ultrashort laser methods, such as the measurement of longitudinal electron bunch profiles in particle accelerators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron energy distribution functions measured by Langmuir probe with optical emission spectroscopy in very high frequency capacitive discharge in nitrogen

By using a rf compensated Langmuir probe and optical emission spectroscopy, the effects of driving frequency (13.56-50 MHz) on the electron energy probability function (EEPF), electron density, electron temperature, and the vibrational and rotational temperatures in capacitively coupled nitrogen discharge were investigated. Measurements were performed in the pressure range 60-200 mTorr, and at a fixed voltage of 140 V (peak-to-peak). With increasing the driving frequency, the dissipated power and electron density markedly increased along with the intensity of the optical emission lines belonging to the 2nd positive (337.1 nm) and 1st negative systems (391.4 nm) of N{sub 2}. The EEPF at low pressure 60 mTorr is two-temperature (bi-Maxwellian) distribution, irrespective of the driving frequency, in contrast with argon and helium discharges in the similar conditions. The mechanism forming such bi-Maxwellian shape was explained by two combined effects: one is the collisionless sheath-heating effect enhancing the tail electron population, and the other is the collision-induced reduction of electrons at the energy 2-4 eV where the collision cross-section for the vibrational excitation has a resonantly large peak. The two-temperature EEPF structure was basically retained at moderate pressure 120 mTorr and high pressure 200 mTorr. The vibrational temperature T{sub vib} and rotational temperature T{sub rot} are measured for the sequence ({Delta}{nu}=-2) of N{sub 2} second positive system (C{sup 3}{Pi}{sub u}{yields}B{sup 3}{Pi}{sub g}) using the method of comparing the measured and calculated spectra with a chi-squared minimization procedure. It was found that, both of T{sub vib} and T{sub rot} are a weakly dependent on driving frequency at low pressure 60 mTorr. At higher pressure (120 and 200 mTorr), T{sub vib} rises monotonically with the driving frequency, whereas the T{sub rot} slightly decreases with frequency below 37 MHz, beyond which it relatively increases or saturated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

A 10-ps, 263-nm (4{omega}) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution ({approx}1 -{mu}m full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10{sup 4} with respect to all wavelengths outside of the 263 {+-} 2 nm measurement range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of axial neutral density profiles in a microwave discharge ion thruster by laser absorption spectroscopy with optical fiber probes

In order to reveal the physical processes taking place within the ''{mu}10'' microwave discharge ion thruster, internal plasma diagnosis is indispensable. However, the ability of metallic probes to access microwave plasmas biased at a high voltage is limited from the standpoints of the disturbance created in the electric field and electrical isolation. In this study, the axial density profiles of excited neutral xenon were successfully measured under ion beam acceleration by using a novel laser absorption spectroscopy system. The target of the measurement was metastable Xe I 5p{sup 5}({sup 2}P{sup 0}{sub 3/2})6s[{sup 3}/{sub 2}]{sup 0}{sub 2} which absorbed a wavelength of 823.16 nm. Signals from laser absorption spectroscopy that swept a single-mode optical fiber probe along the line of sight were differentiated and converted into axial number densities of the metastable neutral particles in the plasma source. These measurements revealed a 10{sup 18} m{sup -3} order of metastable neutral particles situated in the waveguide, which caused two different modes during the operation of the {mu}10 thruster. This paper reports a novel spectroscopic measurement system with axial resolution for microwave plasma sources utilizing optical fiber probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of laser-driven shock waves in solids using a fiber optic pressure probe

Measurement of laser-driven shock wave pressure in solid blocks of polymethyl methacrylate is demonstrated using fiber optic pressure probes. Three probes based on a fiber Fabry–Perot, fiber Bragg grating, and interferometric fiber tip sensor are tested and compared. Shock waves are generated using a high-power laser focused onto a thin foil target placed in close proximity to the test blocks. The fiber Fabry–Perot sensor appears capable of resolving the shock front with a rise time of 91 ns. As a result, the peak pressure is estimated, using a separate shadowgraphy measurement, to be 3.4 GPa.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polar asymmetry of La{sub (1−δ)}Al{sub (1+δ)}O{sub 3}/SrTiO{sub 3} heterostructures probed by optical second harmonic generation

By combining transport measurements and optical second harmonic generation, we have investigated heterostructures formed between crystalline thin films of LaAlO{sub 3}, with varying stoichiometry and TiO{sub 2}-terminated SrTiO{sub 3}(001) substrates. Optical second harmonic generation directly probes the polarity of these heterostructures, thus complementing the transport data. The stoichiometry and the growth temperature are found to be critical parameters for controlling both the interfacial conductivity and the heterostructure polarity. In agreement with the previous work, all of the samples display an insulator-to-metal transition in the Al-reach region, with the conductivity first increasing and then saturating at the highest Al/La ratios. The second harmonic signal also increases as a function of the Al/La ratio, but, at the highest growth temperature, it does not saturate. This unusual behavior is consistent with the formation of an ordered structure of defect dipoles in the LaAlO{sub 3} film caused by the off-centering of excess Al atoms in agreement with the theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Fiber optic transport probe for Hall measurements under light and magnetic field at low temperatures: Case study of a two dimensional electron gas

A fiber optic based probe is designed and developed for electrical transport measurements in presence of quasi-monochromatic (360–800 nm) light, varying temperature (T = 1.8–300 K), and magnetic field (B = 0–7 T). The probe is tested for the resistivity and Hall measurements performed on a LaAlO{sub 3}–SrTiO{sub 3} heterointerface system with a conducting two dimensional electron gas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of spout diameter in gas-solid spouted beds using factorial design of experiments approach with the aid of advanced optical fibre probe

In this study, the effects of five operating and design variables (solid density, static bed height, particle diameter, superficial gas velocity, and inlet diameter) on the average spout diameter of a 0.152 m inside diameter gas-solid spouted bed have been assessed experimentally using advanced gas-solid optical fibre probe technique. Statistical analysis of the experimental data including the factorial design of the experiments using MINITAB17 statistical software has been performed to determine the extent of the effects of these variables on the spout diameter as a case study. It was found that all five operating and design variables, except the solid density together with the 2-ways interactions between particles size and inlet diameter, in addition to gas velocity and inlet diameter, have a significant effect on the average spout diameter. Regression analysis was performed to correlate these variables with the average spout diameter for the gas-solid spouted beds. The obtained preliminary regression correlation was able to closely predict the average spout diameter of this work with the mean relative deviation value of 0.7 %.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probes for measuring fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch

Several probes have been constructed to measure fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch (RFP). The magnetic probe is composed of six magnetic pickup coil triplets. The triplets are separated spatially, which allows for local measurements of the Maxwell stress. To measure the plasma flow components for evaluation of the Reynolds stress, we employ a combination of an optical probe [Kuritsyn et al., Rev. Sci. Indrum. 77, 10F112 (2006)] and a Mach probe. The optical probe measures the radial ion flow locally using Doppler spectroscopy. The Mach probe consists of four current collectors biased negatively with respect to a reference tip and allows for measurements of the poloidal and toroidal components of the bulk plasma flow. The stresses are observed to play an important role in the momentum balance in the RFP edge during internal reconnection events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber-Optic Raman Probe for On-line EAF Slag Analysis

Here, in Electric Arc Furnace (EAF) steelmaking, the push for improved efficiency requires accurate analysis of the chemical composition of its slag system to control slag foaming, provide refractory protection, and maintain high furnace iron yield. Therefore, the ability to obtain real-time slag chemistry data would provide a useful tool to improve the control and efficiency of the process. The work reported here aims to assess the structure and chemistry of EAF slags at high temperatures using a portable fiber-optic Raman probe. As a result, the ability to relate Raman spectra peaks to chemistry and structure is demonstrated in experimental result with EAF slags at 1550°C.

47 OTHER INSTRUMENTATION↗

Single-crystal sapphire tubes as economical probes for optical pyrometry in harsh environments

One-end-sealed single-crystal sapphire tubes are presented as a simple, robust, and economical alternative for bulky lightpipe probes. Thermal radiation from a blackbody cavity created at the inner surface of the sealed end is gathered by a simple lens-based collecting system and transmitted via optical fiber to the remote detection unit. Simplicity and applicability of the concept are demonstrated by the combination of commercially available sapphire tubes with a common optical pyrometer. Radiation thermometers with sapphire tubes as invasive probes can be useful for applications requiring immunity to electromagnetic interference, resistance to harsh environments, simple replacement in the case of failure, and enhanced mechanical firmness, enabling wider range probe positioning inside the medium of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Comparison of Dye and Ultrasmall Fluorescent Silica Core–Shell Nanoparticle Probes for Optical Super-Resolution Imaging of Model Block Copolymer Thin Film Surfaces

In recent years, high-resolution optical imaging in the far field has provided opportunities for alternative approaches to nanocharacterization traditionally dominated by electron and scanning probe microscopies. Here in this paper, we report the optical super-resolution imaging of model block copolymer (BCP) thin film surface nanostructures through stochastic optical reconstruction microscopy (STORM). We compare a set of surface-functionalized fluorescent core–shell silica nanoparticles encapsulating two different organic dyes, Cy3 and Cy5, with the corresponding free dyes in STORM. Using various click-type chemistries, these probes are covalently attached to the surface of specific blocks of BCP thin films, enabling selective block labeling and optical visualization. We demonstrate that the enhanced brightness of these particle probes offers distinct advantages over conventional dye labeling, outperforming one of the best STORM dyes available (Cy5).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗