Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

System and method for plasmonic control of short pulses in optical fibers

The present disclosure relates to an optical waveguide system. The system has a first waveguide having a core-guide and a cladding material portion surrounding and encasing the core-guide to form a substantially D-shaped cross sectional profile with an exposed flat section running along a length thereof. The core-guide enables a core-guide mode for an optical pulse signal having a first characteristic, travelling through the core-guide. A material layer of non-linear material is used which forms a second waveguide. The material layer is disposed on the exposed flat section of the cladding material portion. The material layer forms a plasmonic device to achieve a desired coupling with the core-guide to couple optical energy travelling through the core-guide into the material layer to modify the optical energy travelling through the core-guide such that the optical energy travelling through the core-guide has a second characteristic different from the first characteristic.

Feigenbaum, Eyal↗

Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients

Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT). In this project, the non-imaging probe of the fhSPECT system was replaced by a unique handheld gamma camera containing an array of sodium iodide crystals optically coupled to an array of silicon photomultipliers (SiPMs). A feasibility study was performed in which preoperative SLN mapping was performed using camera fhSPECT and the number of detected nodes was compared to that visualized by lymphoscintigraphy, probe fhSPECT, and to the number ultimately excised under non-imaging probe guidance. Among five subjects, SLNs were detected in nine lymphatic basins, with one to five SLNs detected per basin. A basin-by-basin comparison showed that the number of SLNs detected using camera fhSPECT exceeded that using lymphoscintigraphy and probe fhSPECT in seven of nine basins and five of five basins, respectively. (Probe fhSPECT scans were not performed for four basins.) It exceeded the number excised under non-imaging probe guidance for seven of nine basins and equaled the number excised for the other two basins. Freehand SPECT using a prototype SiPM-based gamma camera demonstrates high sensitivity for detection of SLNs in a preoperative setting. Camera fhSPECT is a potential means for efficiently obtaining real-time 3D activity distribution maps in applications such as image-guided percutaneous biopsy, and surgical SLN biopsy or radioguided tumor excision.

60 APPLIED LIFE SCIENCES↗

Wide-Gap Perovskite via Synergetic Surface Passivation and Its Application toward Efficient Stacked Tandem Photovoltaics

Superior bandgap tunability enables solution-processed halide perovskite a promising candidate for multi-junction photovoltaics (PVs). Particularly, optically coupling wide-gap perovskite by stacking with commercially available PVs such as silicon and CIGS (also known as 4-terminal tandem) simplifies the technology transfer process, and further advances the commercialization potential of perovskite technology. However, compared with matured PV materials and the phase-pure FAPbI 3 , wide-gap perovskite still suffers from huge voltage deficits. Here, the authors take advantage of the synergetic effect behind a sequential fluoride and organic ammonium salt surface passivation strategy to control non-radiative energy losses, and obtained a 17.7% efficiency in infrared-transparent wide-gap perovskite solar cells (21.1% for opaque device), and achieved efficiencies of over 25% when stacked with commercial Si and CIGS products with original PCEs of 18–20% under a 4-terminal working condition.

36 MATERIALS SCIENCE↗

Nonlinear Nano‐Imaging of Interlayer Coupling in 2D Graphene‐Semiconductor Heterostructures

The emergent electronic, spin, and other quantum properties of 2D heterostructures of graphene and transition metal dichalcogenides are controlled by the underlying interlayer coupling and associated charge and energy transfer dynamics. However, these processes are sensitive to interlayer distance and crystallographic orientation, which are in turn affected by defects, grain boundaries, or other nanoscale heterogeneities. This obfuscates the distinction between interlayer charge and energy transfer. Here, nanoscale imaging in coherent four‐wave mixing (FWM) and incoherent two‐photon photoluminescence (2PPL) is combined with a tip distance‐dependent coupled rate equation model to resolve the underlying intra‐ and inter‐layer dynamics while avoiding the influence of structural heterogeneities in mono‐ to multi‐layer graphene/WSe 2 heterostructures. With selective insertion of hBN spacer layers, it is shown that energy, as opposed to charge transfer, dominates the interlayer‐coupled optical response. From the distinct nano‐FWM and ‐2PPL tip‐sample distance‐dependent modification of interlayer and intralayer relaxation by tip‐induced enhancement and quenching, an interlayer energy transfer time of τ ET ≈ ( 0 . 35 − 0.15 + 0.65 ) $\tau _{\rm ET} \approx (0.35^{+0.65}_{-0.15})$ ps consistent with recent reports is derived. As a local probe technique, this approach highlights the ability to determine intrinsic sample properties even in the presence of large sample heterogeneity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Reducing the Susceptibility of Lumped-Element KIDs to Two-Level System Effects

Arrays of lumped-element kinetic inductance detectors (LEKIDs) optically coupled through an antenna-coupled transmission line are a promising candidate for future cosmic microwave background experiments. However, the dielectric materials used for the microstrip architecture are known to degrade the performance of superconducting resonators. In this paper, we investigate the feasibility of microstrip coupling to a LEKID, focusing on a systematic study of the effect of depositing amorphous silicon nitride on a LEKID. The discrete and spatially separated inductive and capacitive regions of the LEKID allow us to vary the degree of dielectric coverage and determine the limitations of the microstrip coupling architecture. We show that by careful removal of dielectric from regions of high electric field in the capacitor, there is minimal degradation in dielectric loss tangent of a partially covered lumped-element resonator. We present the effects on the resonant frequency and noise power spectral density and, using the dark responsivity, provide an estimate for the resulting detector sensitivity.

47 OTHER INSTRUMENTATION↗

A position and pulse shape discriminant p -terphenyl detector module

We present the development of a neutron detector array module made with para-terphenyl, a bright, fast, n/γ discriminating crystalline organic scintillator. The module is comprised of 2 cm × 2 cm × 2 cm p-terphenyl crystals that have been optically coupled together to create a pseudo-bar module. While only relying on two photo detectors, the module is capable of distinguishing interactions between up to eight crystals. Furthermore, the module retains the p-terphenyl’s pulse shape discrimination (PSD) capability. Together this makes the pseudo-bar module a promising position-sensitive neutron detector. Here we present characteristics of the pseudo-bar module - its timing resolution as well as its pulse shape and position discrimination capabilities, and briefly discuss future plans for utilizing an array of pseudo-bar modules in a useful neutron detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator based nuclear photovoltaic batteries for power generation at microwatts level

A nuclear photovoltaic battery uses scintillator to convert radiation into visible light, which is then collected by a photovoltaic (PV) cell to generate electricity. If the radiation is gamma-rays emitted from external sources, the battery may also be referred as gammavoltaic battery. In this study, a polycrystalline CdTe solar cell was optically coupled with a 2.0 cm × 2.0 cm × 1.0 cm Gadolinium Aluminum Gallium Garnet (GAGG) scintillator, and the resulting device was tested using intense gamma radiation fields from a Cs-137 (1.5 kRad/h) and a Co-60 (10 kRad/h) irradiator. Measurements with Cs-137 provided a maximum power output (P max ) of ~288 nW, with a short-circuit current density (J sc ) of ~1.22 μA/cm 2 and an open-circuit voltage (V oc ) of ~0.34 V. In contrast, Co-60 irradiator gave a P max of 1.5 μW, with a J sc of ~4.73 μA/cm 2 and a V oc of ~0.38 V. The CdTe was also paired with a Lutetium-Yttrium Oxyorthosilicate (LYSO) crystal and tested with the Cs-137 source. The experiment presents a scalable option to reach to higher power outputs by harvesting gamma radiation fields in many cases where high radiation field demands heavy shielding and is often regarded as unwanted waste.

25 ENERGY STORAGE↗

Measurement of flow properties coupled to experimental and numerical analyses of dense, granular flows for solar thermal energy storage

Granular flows of sintered bauxite proppants were researched along an inclined plane for solar thermal energy storage applications. Granular flow properties needed to drive numeric granular models were measured for improved numerical model predictions for Carbobead CP 50/140, 40/100, and 30/60 particles. Particle shape and size distributions were determined by coupling optical microscopy to an in-house image processing algorithm. The impulse excitation technique was used to measure elastic and shear moduli, and compute Poisson’s ratio. The coefficient of static sliding friction was measured using the slip-stick method, and the static rolling friction was determined from measured shear on particles positioned between two hot-pressed plates. The coefficient of restitution was measured by dropping particles on a surface and determining the kinetic energy before and after impact with the surface using high resolution particle tracking velocimetry. Particle size did not significantly impact the coefficients of restitution and static rolling friction, however, particle shape distribution resulted in a large variation in measurements. An inclined flow experiment was performed to characterize granular flows of Carbobead CP 30/60 particles using particle image velocimetry. Numerical models of the experiment using discrete element method were generated with the measured mechanical properties as inputs for comparison with experimental results. A constant directional torque rolling friction model best predicted bulk granular flow behavior. Furthermore, good agreement between the model and experiment was achieved at ambient, steady state conditions, with average velocity differences <10%.

14 SOLAR ENERGY↗

Purcell-Enhanced Emissions from Diamond Color Centers in Slow Light Photonic Crystal Waveguides

Diamond color centers are promising candidates for optically addressable quantum memories, which motivates the development of efficient photonic interfaces, often using nanophotonic cavities with narrow spectral line widths and small mode volumes. However, they require perfect spectral and spatial overlap between the cavity mode and quantum emitter, which is challenging. This is especially true for solid-state quantum emitters that are often randomly positioned and suffer from inhomogeneous broadening. Another approach to enhance light-matter interaction across large optical bandwidths and areas is using slow light waveguides. Here, in this study, we demonstrate diamond slow light photonic crystal (PhC) waveguides optically coupled to embedded silicon-vacancy (SiV) color centers. We use the recently developed thin-film diamond approach to fabricate fully suspended two-dimensional PhC waveguides. We demonstrate waveguide modes with high group indices up to 70 and observe Purcell-enhanced emissions of the SiVs. Our approach represents a practical diamond platform for robust spin-photon interfaces with color centers.

2D photonic crystal waveguide↗

Coupled order parameters and photoinduced domain walls in the charge density wave of (TaSe 4 ) 2 I

The charge density wave in (TaSe 4 ) 2 I has drawn much attention recently as a controversial candidate for an axion insulator where the CDW breaks the chiral symmetry of the Weyl semimetal. Here we use ultrafast x-ray scattering to study the collective modes of this CDW. By measuring several diffraction peaks we find that the order parameter involves coupled optical and acoustic modes. For strong near-infrared excitation, the dynamics of the x-ray diffraction show evidence of photoinduced inversion of both components of the CDW order parameter, and associated domain walls. These results demonstrate the potential of ultrafast methods to induce topological defects through highly nonequilibrium dynamics. In (TaSe 4 ) 2 I these defects should lead to exotic electronic states due to the nontrivial topology of the band structure.

36 MATERIALS SCIENCE↗

Optimization of switch diagnostics on the MAIZE linear transformer driver

The MAIZE Linear Transformer Driver is made of 40 capacitor-switch-capacitor `bricks' connected in parallel. When these 40 bricks are charged to 100-kV and then discharged synchronously, the MAIZE facility generates a 1-MA current pulse with a 100-ns rise time into a matched load impedance. Discharging each of the capacitors in a brick is carried out by the breakdown of a spark-gap switch, a process which results in the emission of light. Monitoring this output light with a fiber optic coupled to a photomultiplier tube (PMT) and an oscilloscope channel provides information on switch performance and timing jitter– whether a switch red early, late, or in phase with the other switches. However, monitoring each switch with a dedicated detector- oscilloscope channel can be problematic for facilities where the number of switches to be monitored (e.g., 40 on MAIZE) greatly exceeds the number of detector-oscilloscope channels available. The technique of using fibers to monitor light emission from switches can be optimized by treating a PMT as a binary digit or bit and using a combinatorial encoding scheme, where each switch is monitored by a unique combination of fiber- PMT-oscilloscope channels simultaneously. By observing the unique combination of ber-PMT-oscilloscope channels that are turned on, the pre-firing or late-firing of a single switch on MAIZE can be identified by as few as six PMT-oscilloscope channels. The number of PMT-oscilloscope channels, N , required to monitor X switches can be calculated by 2 N = X + 1, where the number '2' is selected because the PMT-oscilloscope acts as a bit. Here, we demonstrate the use of this diagnostic technique on MAIZE. In conclusion, we also present an analysis of how this technique could be scaled to monitor the tens of thousands of switches proposed for various next generation pulsed power facilities.

47 OTHER INSTRUMENTATION↗

The MURAVES muon telescope: a low power consumption muon tracker for muon radiography applications

Muon Radiography or muography is based on the measurement of the absorption or scattering of cosmic muons, as they pass through the interior of large scale bodies, In particular, absorption muography has been applied to investigate the presence of hidden cavities inside the pyramids or underground, as well as the interior of volcanoes’ edifices. The MURAVES project has the challenging aim of investigating the density distribution inside the summit of Mt. Vesuvius. The information, together with that coming from gravimetric measurements, is useful as input to models, to predict how an eruption may develop. The MURAVES apparatus is a robust and low power consumption muon telescope consisting of an array of three identical and independent muon trackers, which provide in a modular way a total sensitive area of three square meters. Each tracker consists of four doublets of planes of plastic scintillator bars with orthogonal orientation, optically coupled to Silicon photomultipliers for the readout of the signal. The muon telescope has been installed on the slope of the volcano and has collected a first set of data, which are being analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm &#x00d7; 5mm &#x00d7; 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 &#x00d7; 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Investigating resource-efficient neutron/gamma classification ML models targeting eFPGAs

There has been considerable interest and resulting progress in implementing machine learning (ML) models in hardware over the last several years from the particle and nuclear physics communities. A big driver has been the release of the Python package, hls4ml, which has enabled porting models specified and trained using Python ML libraries to register transfer level (RTL) code. So far, the primary end targets have been commercial field-programmable gate arrays (FPGAs) or synthesized custom blocks on application specific integrated circuits (ASICs). However, recent developments in open-source embedded FPGA (eFPGA) frameworks now provide an alternate, more flexible pathway for implementing ML models in hardware. These customized eFPGA fabrics can be integrated as part of an overall chip design. In general, the decision between a fully custom, eFPGA, or commercial FPGA ML implementation will depend on the details of the end-use application. In this work, we explored the parameter space for eFPGA implementations of fully-connected neural network (fcNN) and boosted decision tree (BDT) models using the task of neutron/gamma classification with a specific focus on resource efficiency. We used data collected using an AmBe sealed source incident on Stilbene, which was optically coupled to an OnSemi J-series silicon photomultiplier (SiPM) to generate training and test data for this study. We investigated relevant input features and the effects of bit-resolution and sampling rate as well as trade-offs in hyperparameters for both ML architectures while tracking total resource usage. The performance metric used to track model performance was the calculated neutron efficiency at a gamma leakage of 10 -3 . The results of the study will be used to aid the specification of an eFPGA fabric, which will be integrated as part of a test chip.

47 OTHER INSTRUMENTATION↗

Luminescent Solar Concentrator Tandem-on-Silicon with above 700mV Passivated Contact Silicon Bottom Cell

Luminescent solar concentrator (LSC) tandem-on-silicon (Si) provides a route towards achieving higher than 30% overall efficiency which can overcome the theoretical efficiency limit of a single junction Si cell. Here, we present optical coupling and performance of high Voc passivated contact Si bottom cell for LSC tandem-on-Si where the top module consists of highly efficient luminophores and an array of micro InGaP cells embedded in a poly (lauryl methacrylate) waveguide. In this device configuration, InGaP cell area coverage is only ~0.5% of the total LSC area which significantly reduces the high cost III-V material usage. The performance of Si sub-cell is investigated under LSC spectrum and is compared against the measurement done under 1 um thick InGaP filter which mimics the spectrum seen by Si bottom cell in a conventional III-V/Si tandem. V oc of greater than 700 mV has been observed for the passivated contact Si bottom cell in these tandem applications.

14 SOLAR ENERGY↗

Flow Injection Electrochemical Quartz Crystal Microbalance with ICP-OES Detection: Electroprecipitation and Stripping of Lanthanum and Neodymium in a Flow Cell

We used an improved version of our hyphenated analysis technique, flow injection electrochemical quartz crystal microbalance (EQCM) with inductively coupled optical emission spectroscopy, to investigate the electroprecipitation of lanthanum and neodymium from flowing solutions. The improved version has two independent flow injection circuits, allowing different conditions for electrochemical precipitation (pH=4.3 or 2.6) and quick stripping (2% HNO3) with EQCM mass detection and ICP-OES elemental analysis. Lanthanum or neodymium ions in a 500 uL sample were injected into a carrier stream and deposited onto an EQCM housed in a micro flow cell, owing to a localized high-pH layer. The deposits are subsequently stripped from the electrode using HNO3 and analyzed downstream using an ICP-OES. We found that using acidic solutions without supporting electrolyte leads to an increase of the amount of lanthanum detected by 4-fold. The enhanced deposition can be attributed to enhanced mass transfer by migration. Furthermore, we showed that by applying chronopotentiometry, we can detect a change in the hydrogen evolution reaction mechanism that enables the precipitation of lanthanides on the surface of the electrode. Understanding and enhancing the deposition of lanthanides is relevant for elemental or isotopic detection in nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-speed fiber-coupled terahertz time-domain spectroscopy system using a bias-free plasmonic source

We demonstrate a high-speed fiber-coupled terahertz time-domain spectroscopy (THz-TDS) system using a bias-free plasmonic terahertz source. The system is powered by a compact, low-power femtosecond fiber laser oscillator that drives a dual-branch fiber amplifier to pump and probe a plasmonic terahertz source and detector, respectively. A polarization-maintaining, fiber-coupled optical delay line is employed to precisely control the temporal offset between the pump and probe beams through a compact, robust platform. Operating in the self-similar amplification regime, the fiber amplifiers are engineered to mitigate nonlinear pulse distortion and dispersion while delivering robust, high-energy pulses at a 1560-nm wavelength, with an output power exceeding 326 mW. In reflection mode, the THz-TDS system achieves a peak dynamic range of 81 dB and a bandwidth greater than 3.5 THz at a scan rate of 3.75 Hz. The utility of the system for rapid sensing is further demonstrated by quantifying the porosity and density of pharmaceutical tablets through measurements of their physical thickness and effective refractive index.

Jiang, Xinghe [University of California, Los Angel↗