Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optical imaging module for astigmatic detection system

In this paper, an optical imaging module design for an astigmatic detection system (ADS) is presented. The module is based on a commercial optical pickup unit (OPU) and it contains a coaxial illuminant for illuminating a specimen. Furthermore, the imaging module facilitates viewing the specimen and the detection laser spot of the ADS with a lateral resolution of approximately 1 μm without requiring the removal of an element of the OPU. Two polarizers and one infrared filter are used to eliminate stray laser light in the OPU and stray light produced by the illuminant. Imaging modules designed for digital versatile disks (DVDs) and Blu-ray DVDs were demonstrated. Furthermore, the module can be used for imaging a small cantilever with approximate dimensions of 2 μm (width) × 5 μm (length), and therefore, it has the potential to be used in high-speed atomic force microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile recognition of graphene layers from optical images under controlled illumination through green channel correlation method

In this study, a simple yet versatile method is proposed for identifying the number of exfoliated graphene layers transferred on an oxide substrate from optical images, utilizing a limited number of input images for training, paired with a more traditional number of a few thousand well-published Github images for testing and predicting. Two thresholding approaches, namely the standard deviation-based approach and the linear regression-based approach, were employed in this study. The method specifically leverages the red, green, and blue color channels of image pixels and creates a correlation between the green channel of the background and the green channel of the various layers of graphene. This method proves to be a feasible alternative to deep learning-based graphene recognition and traditional microscopic analysis. The proposed methodology performs well under conditions where the effect of surrounding light on the graphene-on-oxide sample is minimum and allows rapid identification of the various graphene layers. Here, the study additionally addresses the functionality of the proposed methodology with nonhomogeneous lighting conditions, showcasing successful prediction of graphene layers from images that are lower in quality compared to typically published in literature. In all, the proposed methodology opens up the possibility for the non-destructive identification of graphene layers from optical images by utilizing a new and versatile method that is quick, inexpensive, and works well with fewer images that are not necessarily of high quality.

36 MATERIALS SCIENCE↗

Ultrafast transient grating radiation to optical image converter

A high sensitivity transient grating ultrafast radiation to optical image converter is based on a fixed transmission grating adjacent to a semiconductor substrate. X-rays or optical radiation passing through the fixed transmission grating is thereby modulated and produces a small periodic variation of refractive index or transient grating in the semiconductor through carrier induced refractive index shifts. An optical or infrared probe beam tuned just below the semiconductor band gap is reflected off a high reflectivity mirror on the semiconductor so that it double passes therethrough and interacts with the radiation induced phase grating therein. A small portion of the optical beam is diffracted out of the probe beam by the radiation induced transient grating to become the converted signal that is imaged onto a detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE GRAY NEEDLE: LARGE GRAINS IN THE HD 15115 DEBRIS DISK FROM LBT /PISCES/Ks AND LBTI /LMIRcam/L' ADAPTIVE OPTICS IMAGING

We present diffraction-limited Ks band and L' adaptive optics images of the edge-on debris disk around the nearby F2 star HD 15115, obtained with a single 8.4 m primary mirror at the Large Binocular Telescope. At the Ks band, the disk is detected at signal-to-noise per resolution element (SNRE) {approx} 3-8 from {approx}1 to 2.''5 (45-113 AU) on the western side and from {approx}1.''2 to 2.''1 (63-90 AU) on the east. At L' the disk is detected at SNRE {approx} 2.5 from {approx}1 to 1.''45 (45-90 AU) on both sides, implying more symmetric disk structure at 3.8 {mu}m. At both wavelengths the disk has a bow-like shape and is offset from the star to the north by a few AU. A surface brightness asymmetry exists between the two sides of the disk at the Ks band, but not at L'. The surface brightness at the Ks band declines inside 1'' ({approx}45 AU), which may be indicative of a gap in the disk near 1''. The Ks - L' disk color, after removal of the stellar color, is mostly gray for both sides of the disk. This suggests that scattered light is coming from large dust grains, with 3-10 {mu}m sized grains on the east side and 1-10 {mu}m dust grains on the west. This may suggest that the west side is composed of smaller dust grains than the east side, which would support the interpretation that the disk is being dynamically affected by interactions with the local interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Post maximum light and late time optical imaging polarimetry of type I superluminous supernova 2020znr

ABSTRACT Optical imaging polarimetry was conducted on the hydrogen poor superluminous supernova 2020znr during three phases after maximum light (≈ +34 d, +288 d, and +289 d). After instrumental and interstellar polarization correction, all measurements are consistent with null-polarization detection. Modelling the light curve with a magnetar spin-down model shows that SN2020znr has similar magnetar and ejecta parameters to other SLSNe. A comparison of the best-fitting values discussed in the literature on SN 2017egm and SN 2015bn, two hydrogen poor SLSNe showing an increase of polarization after maximum light, suggests that SN 2020znr has higher mass ejecta that may prevent access to the geometry of the inner ejecta with optical polarimetry. The combined information provided by spectroscopy and light-curve analysis of type I SLSNe may be an interesting avenue to categorize the polarization properties of this class of transients. This approach would require to expand the sample of SLSNe polarimetry data currently available with early and late time epochs new measurements.

2015bn↗

Optical image analysis of WSe 2 − thresholding for layer detection

The fast and reliable layer identification of two-dimensional transition metal dichalcogenide (TMD), such as WSe 2 , is essential to investigating their thickness-dependent electronic and optical properties. This article presents efficient optical image thresholding methodology designed to segment the mono, bi, and tri-layer regions of WSe 2 flakes mechanically exfoliated onto a SiO 2 /Si substrate. The optical images were first preprocessed to exclude the background effect and analyzed using the pixel medians and interquartile ranges for fundamental color channels—red, green, and blue (RGB). The analysis of red channel pixel intensities yielded three distinct ranges, serving as thresholds for layer segmentation: monolayer (111.0–118.0), bilayer (103.0–110.0), and tri-layer (93.0–103.0). Similarly, thresholds were established for each color channel, facilitating a comparative study of the segmentation performances. Further, the intersection-over-union ($IoU$) calculations revealed that the red and green channels demonstrated greater than 99 % and 90 % accuracy in differentiating each layer, respectively. This approach yields remarkable results without substantial data calibration that utilizes time-intensive heuristic techniques. Moreover, the proposed methodology offers the flexibility to compare performances across different color channels, expanding the applicability for other 2D material systems.

2D Materials↗

ALFALFA DISCOVERY OF THE NEARBY GAS-RICH DWARF GALAXY LEO P. II. OPTICAL IMAGING OBSERVATIONS

We present results from ground-based optical imaging of a low-mass dwarf galaxy discovered by the ALFALFA 21 cm H I survey. Broadband (BVR) data obtained with the WIYN 3.5 m telescope at Kitt Peak National Observatory (KPNO) are used to construct color-magnitude diagrams of the galaxy's stellar population down to V{sub o} {approx} 25. We also use narrowband H{alpha} imaging from the KPNO 2.1 m telescope to identify a H II region in the galaxy. We use these data to constrain the distance to the galaxy to be between 1.5 and 2.0 Mpc. This places Leo P within the Local Volume but beyond the Local Group. Its properties are extreme: it is the lowest-mass system known that contains significant amounts of gas and is currently forming stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimum detection of an optical image on a photoelectric surface

The detection of an optical image in the presence of uniform background light is based on a likelihood ratio formed of the numbers of photoelectrons emitted from small elements of a photoelectric surface onto which the image is focused. When diffraction is negligible and the surface has unit quantum efficiency, this detector is equipollent with the optimum detector of the image forming light. Its performance is compared with that of the threshold detector and that of a detector basing its decisions on the total number of photoelectrons from a finite area of the image. The illuminance of the image is postulated to have a Gaussian spatial distribution. All three detectors exhibit nearly the same reliability.

Helstrom, C. W.↗

Optical imaging of the low redshift superluminous QSO 1821 + 643

Optical imaging is presented of the luminous z = 0.3 QSO 1821 + 643, with resolution 1.0 and 0.4 arcsec. The host galaxy is resolved and seen to be large, featureless, and red, with slightly displaced outer isophotes. The nucleus is unusually red. There is a rich cluster of galaxies in the field which is probably at a much higher redshift, and extended nebulosity from a nearby star. These results and the IR properties are discussed in terms of a mature merger of a luminous galaxy in which there is still a considerable amount of central dust and molecular clouds.

Hutchings, J. B.↗

ADAPTIVE OPTICS IMAGES. II. 12 KEPLER OBJECTS OF INTEREST AND 15 CONFIRMED TRANSITING PLANETS

All transiting planet observations are at risk of contamination from nearby, unresolved stars. Blends dilute the transit signal, causing the planet to appear smaller than it really is, or producing a false positive detection when the target star is blended with an eclipsing binary. High spatial resolution adaptive optics images are an effective way of resolving most blends. Here we present visual companions and detection limits for 12 Kepler planet candidate host stars, of which 4 have companions within 4''. One system (KOI 1537) consists of two similar-magnitude stars separated by 0.''1, while KOI 174 has a companion at 0.''5. In addition, observations were made of 15 transiting planets that were previously discovered by other surveys. The only companion found within 1'' of a known planet is the previously identified companion to WASP-2b. An additional four systems have companions between 1'' and 4'': HAT-P-30b (3.''7, {Delta}Ks = 2.9), HAT-P-32b (2.''9, {Delta}Ks = 3.4), TrES-1b (2.''3, {Delta}Ks = 7.7), and WASP-P-33b (1.''9, {Delta}Ks = 5.5), some of which have not been reported previously. Depending on the spatial resolution of the transit photometry for these systems, these companion stars may require a reassessment of the planetary parameters derived from transit light curves. For all systems observed, we report the limiting magnitudes beyond which additional fainter objects located 0.''1-4'' from the target may still exist.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of CO(1-0) emission and optical imaging of the Seyfert galaxy/QSO Markarian 231

The detection of CO(J = 1-0) emission and optical imaging of the luminous infrared galaxy Markarian 231 are reported. The galaxy is extremely rich in molecular gas with MT(H2) approximately equal to 1.4 x 10 to the 10th solar masses, approximately 5 times the molecular gas content of the Galaxy. Markarian 231 is the most luminous object in the local universe (z approximately equal to or less than 0.1), with a far-infrared luminosity (lambda = 40-400 microns) of 2.1 x 10 to the 12th solar luminosities. THe CO detection yields a L(FIR)/M(H2) ratio of 150. A deep optical CCD image shows two striking tidal tails with total extent of about 75 kpc. The CCD image strongly suggests that Markarian 231 is an advanced merger system. If the molecular gas is highly concentrated in the nuclear region it may fuel an intense starburst and possibly feed the accretion onto an embedded QSO. The trigger for the intense activity observed in Markarian 231 appears to be the collision of two gas-rich spiral galaxies.

Sanders, D. B.↗

Pulmonary toxicity and kinetic study of Cy5.5-conjugated superparamagnetic iron oxide nanoparticles by optical imaging

Recent advances in the development of nanotechnology and devices now make it possible to accurately deliver drugs or genes to the lung. Magnetic nanoparticles can be used as contrast agents, thermal therapy for cancer, and be made to concentrate to target sites through an external magnetic field. However, these advantages may also become problematic when taking into account safety and toxicological factors. This study demonstrated the pulmonary toxicity and kinetic profile of anti-biofouling polymer coated, Cy5.5-conjugated thermally cross-linked superparamagnetic iron oxide nanoparticles (TCL-SPION) by optical imaging. Negatively charged, 36 nm-sized, Cy5.5-conjugated TCL-SPION was prepared for optical imaging probe. Cy5.5-conjugated TCL-SPION was intratracheally instilled into the lung by a non-surgical method. Cy5.5-conjugated TCL-SPION slightly induced pulmonary inflammation. The instilled nanoparticles were distributed mainly in the lung and excreted in the urine via glomerular filtration. Urinary excretion was peaked at 3 h after instillation. No toxicity was found under the concentration of 1.8 mg/kg and the half-lives of nanoparticles in the lung and urine were estimated to be about 14.4 {+-} 0.54 h and 24.7 {+-} 1.02 h, respectively. Although further studies are required, our results showed that Cy5.5-conjugated TCL-SPION can be a good candidate for use in pulmonary delivery vehicles and diagnostic probes.

60 APPLIED LIFE SCIENCES↗

Multimodal nonlinear optical imaging via evanescent wave excitation

A system for multimodal nonlinear optical imaging is provided. Each mode uses a high NA objective to cause total internal reflection excitation at a sample-substrate interface. The system has a femtosecond oscillator to generate pulses used for two beams. The objective receives at least one beam, redirects the received at least one beam through a dielectric substrate to cause the TIR and produces corresponding evanescent waves in a portion of the sample adjacent to the sample-substrate interface, and collects a backward-propagating beam of pulses of responsive light. The portion of the sample illuminated by the evanescent waves emits responsive light. Different modes or combinations of the distinct modalities may be selected to access complementary chemical and structural information for various chemical species near the sample-substrate interface. Each mode may have mode-specific control such as selective beam blocking, power ratios and filtering.

Doughty, Benjamin L.↗

SU-F-J-18: Feasibility of Open Mask Immobilization with Optical Imaging Guidance (OIG) for H&N Radiotherapy

Purpose: Full face and neck thermoplastic masks provide standard-of-care immobilization for patients receiving H&N IMRT. However, these masks are uncomfortable and increase skin dose. The purpose of this pilot study was to investigate the feasibility and setup accuracy of open face and neck mask immobilization with OIG. Methods: Ten patients were consented and enrolled to this IRB-approved protocol. Patients were immobilized with open masks securing only forehead and chin. Standard IMRT to 60–70 Gy in 30 fractions were delivered in all cases. Patient simulation information, including isocenter location and CT skin contours, were imported to a commercial OIG system. On the first day of treatment, patients were initially set up to surface markings and then OIG referenced to face and neck skin regions of interest (ROI) localized on simulation CT images, followed by in-room CBCT. CBCTs were acquired at least weekly while planar OBI was acquired on the days without CBCT. Following 6D robotic couch correction with kV imaging, a new optical real-time surface image was acquired to track intrafraction motion and to serve as a reference surface for setup at the next treatment fraction. Therapists manually recorded total treatment time as well as couch shifts based on kV imaging. Intrafractional ROI motion tracking was automatically recorded. Results: Setup accuracy of OIG was compared with CBCT results. The setup error based on OIG was represented as a 6D shift (vertical/longitudinal/lateral/rotation/pitch/roll). Mean error values were −0.70±3.04mm, −0.69±2.77mm, 0.33±2.67 mm, −0.14±0.94 o, −0.15±1.10o and 0.12±0.82o, respectively for the cohort. Average treatment time was 24.1±9.2 minutes, comparable to standard immobilization. The amplitude of intrafractional ROI motion was 0.69±0.36 mm, driven primarily by respiratory neck motion. Conclusion: OGI can potentially provide accurate setup and treatment tracking for open face and neck immobilization. Study accrual and patient/provider satisfaction survey collection remain ongoing. This study is supported by VisionRT, Ltd.

60 APPLIED LIFE SCIENCES↗

Variable Shadow Screens for Imaging Optical Devices

Variable shadow screens have been proposed for reducing the apparent brightnesses of very bright light sources relative to other sources within the fields of view of diverse imaging optical devices, including video and film cameras and optical devices for imaging directly into the human eye. In other words, variable shadow screens would increase the effective dynamic ranges of such devices. Traditionally, imaging sensors are protected against excessive brightness by use of dark filters and/or reduction of iris diameters. These traditional means do not increase dynamic range; they reduce the ability to view or image dimmer features of an image because they reduce the brightness of all parts of an image by the same factor. On the other hand, a variable shadow screen would darken only the excessively bright parts of an image. For example, dim objects in a field of view that included the setting Sun or bright headlights could be seen more readily in a picture taken through a variable shadow screen than in a picture of the same scene taken through a dark filter or a narrowed iris. The figure depicts one of many potential variations of the basic concept of the variable shadow screen. The shadow screen would be a normally transparent liquid-crystal matrix placed in front of a focal-plane array of photodetectors in a charge-coupled-device video camera. The shadow screen would be placed far enough from the focal plane so as not to disrupt the focal-plane image to an unacceptable degree, yet close enough so that the out-of-focus shadows cast by the screen would still be effective in darkening the brightest parts of the image. The image detected by the photodetector array itself would be used as feedback to drive the variable shadow screen: The video output of the camera would be processed by suitable analog and/or digital electronic circuitry to generate a negative partial version of the image to be impressed on the shadow screen. The parts of the shadow screen in front of those parts of the image with brightness below a specified threshold would be left transparent; the parts of the shadow screen in front of those parts of the image where the brightness exceeded the threshold would be darkened by an amount that would increase with the excess above the threshold.

Lu, Ed↗

ADAPTIVE OPTICS IMAGING OF VY CANIS MAJORIS AT 2-5 μm WITH LBT/LMIRCam

We present adaptive optics images of the extreme red supergiant VY Canis Majoris in the K{sub s} , L', and M bands (2.15-4.8 μm) made with LMIRCam on the Large Binocular Telescope. The peculiar ''Southwest Clump'' previously imaged from 1 to 2.2 μm appears prominently in all three filters. We find its brightness is due almost entirely to scattering, with the contribution of thermal emission limited to at most 25%. We model its brightness as optically thick scattering from silicate dust grains using typical size distributions. We find a lower limit mass for this single feature of 5 × 10{sup –3} M {sub ☉} to 2.5 × 10{sup –2} M {sub ☉} depending on the assumed gas-to-dust ratio. The presence of the Clump as a distinct feature with no apparent counterpart on the other side of the star is suggestive of an ejection event from a localized region of the star and is consistent with VY CMa's history of asymmetric high-mass-loss events.

79 ASTRONOMY AND ASTROPHYSICS↗

Developing new optical imaging techniques for single particle and molecule tracking in live cells

Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian cells. New rotational information was obtained: (1) during endocytosis, cargoes lost their rotation freedom at the late stage of internalization; (2) cargoes performed train-like motion when they were transported along the microtubule network by motor proteins inside live cells; (3) During the pause stage of fast axonal transport, cargoes were still bound to the microtubule tracks by motor proteins. Total internal reflection fluorescence microscopy (TIRFM) is another non-invasive and far-field optical imaging technique. Because of its near-field illumination mechanism, TIRFM has better axial resolution than epi-fluorescence microscopy and confocal microscopy. In this work, an auto-calibrated, prism type, angle-scanning TIRFM instrument was built. The incident angle can range from subcritical angles to nearly 90°, with an angle interval less than 0.2°. The angle precision of the new instrument was demonstrated through the finding of the surface plasmon resonance (SPR) angle of metal film coated glass slide. The new instrument improved significantly the precision in determining the axial position. As a result, the best obtained axial resolution was ~ 8 nm, which is better than current existing instruments similar in function. The instrument was further modified to function as a pseudo TIRF microscope. The illumination depth can be controlled by changing the incident angle of the excitation laser beam or adjusting the horizontal position of the illumination laser spot on the prism top surface. With the new technique, i.e., variable-illumination-depth pseudo TIRF microscopy, the whole cell body from bottom to top was scanned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-optical image denoising using a diffractive visual processor

Abstract Image denoising, one of the essential inverse problems, targets to remove noise/artifacts from input images. In general, digital image denoising algorithms, executed on computers, present latency due to several iterations implemented in, e.g., graphics processing units (GPUs). While deep learning-enabled methods can operate non-iteratively, they also introduce latency and impose a significant computational burden, leading to increased power consumption. Here, we introduce an analog diffractive image denoiser to all-optically and non-iteratively clean various forms of noise and artifacts from input images – implemented at the speed of light propagation within a thin diffractive visual processor that axially spans <250 × λ, where λ is the wavelength of light. This all-optical image denoiser comprises passive transmissive layers optimized using deep learning to physically scatter the optical modes that represent various noise features, causing them to miss the output image Field-of-View (FoV) while retaining the object features of interest. Our results show that these diffractive denoisers can efficiently remove salt and pepper noise and image rendering-related spatial artifacts from input phase or intensity images while achieving an output power efficiency of ~30–40%. We experimentally demonstrated the effectiveness of this analog denoiser architecture using a 3D-printed diffractive visual processor operating at the terahertz spectrum. Owing to their speed, power-efficiency, and minimal computational overhead, all-optical diffractive denoisers can be transformative for various image display and projection systems, including, e.g., holographic displays.

36 MATERIALS SCIENCE↗