Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Localized Plasmonic Heating for Single-Molecule DNA Rupture Measurements in Optical Tweezers

To date, studies on the thermodynamic and kinetic processes that underlie biological function and nanomachine actuation in biological- and biology-inspired molecular constructs have primarily focused on photothermal heating of ensemble systems, highlighting the need for probes that are localized within the molecular construct and capable of resolving single-molecule response. Here we present an experimental demonstration of wavelength-selective, localized heating at the single-molecule level using the surface plasmon resonance of a 15 nm gold nanoparticle (AuNP). Our approach is compatible with force-spectroscopy measurements and can be applied to studies of the single-molecule thermodynamic properties of DNA origami nanomachines as well as biomolecular complexes. We further demonstrate wavelength selectivity and establish the temperature dependence of the reaction coordinate for base-pair disruption in the shear-rupture geometry, demonstrating the utility and flexibility of this approach for both fundamental studies of local (nanometer-scale) temperature gradients and rapid and multiplexed nanomachine actuation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

London penetration depth of electron-irradiated Ba 0 . 47 K 0 . 53 Fe 2 As 2

We have characterized an electron-irradiated Ba 1-x K x Fe 2 As 2 (x = 0.53) single-crystal using two different experimental techniques: magneto-optic measurements and microwave measurements. The crystal has been measured before as well as after the 2.5 MeV electron irradiation process. After irradiation it was annealed in a number of steps, between 90 °C and 180 °C, and measured after each annealing step. Most microwave measurements were performed by means of a copper cavity, taking advantage of the TE 011 and TM 110 modes, allowing for the determination of the London penetration depths changes δλ ab (T) and δλ c (T), ie perpendicular and parallel to the sample c-axis. Appropriate equations, based on perturbation theory, were derived to calculate the penetration depths changes δλ ab and δλ c for a rectangular prism geometry. The sample showed a full recovery of its T c , however the observed behavior of δλ c and δλ ab was not monotonic vs annealing temperature, displaying a minimum of δλ c and δλ ab at 120 °C. In conclusion, this finding was confirmed by magneto-optic measurements, where besides verifying the sample uniformity and the absence of visible defects, the lower critical field H c1 of the Ba 1-x K x Fe 2 As 2 single-crystal was obtained and the London penetration depth λab(0) was calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Investigation of Chemo-Mechanical Phenomena and Li Metal Penetration in All-Solid-State Lithium Metal Batteries Using In Situ Optical Curvature Measurements

Solid-electrolytes (SEs) can provide a pathway to increase energy-density in lithium metal batteries. However, lithium metal penetration through garnet based LLZO solid electrolytes has been identified as a critical failure process. This phenomenon is related to chemo-mechanical processes which are difficult to probe. In particular, characterizing the dynamic mechanical deformations that occur in electrode-SE structures is very challenging. Here study reports in situ curvature measurements that are thus designed to probe chemo-mechanical phenomena that occur during lithium plating. The novel experimental cell configuration created for this work shows that pressure builds up in the Li metal during plating, up until the point where short circuits occur. The resulting data are analyzed with a detailed finite element model (FEM) to quantitatively evaluate stress evolution. The results show that Li metal plating within a surface flaw can produce stress build-up prior to short-circuiting. The combined results from both the experiments and the FEM suggest that it is critical to minimize surface defects and flaws during the manufacturing processes.

25 ENERGY STORAGE↗

Hydrogen reionization ends by z = 5.3: Lyman-α optical depth measured by the XQR-30 sample

ABSTRACT The presence of excess scatter in the Ly-α forest at z ∼ 5.5, together with the existence of sporadic extended opaque Gunn-Peterson troughs, has started to provide robust evidence for a late end of hydrogen reionization. However, low data quality and systematic uncertainties complicate the use of Ly-α transmission as a precision probe of reionization’s end stages. In this paper, we assemble a sample of 67 quasar sightlines at z > 5.5 with high signal-to-noise ratios of >10 per ≤15 km s−1 spectral pixel, relying largely on the new XQR-30 quasar sample. XQR-30 is a large program on VLT/X-Shooter which obtained deep (SNR > 20 per pixel) spectra of 30 quasars at z > 5.7. We carefully account for systematics in continuum reconstruction, instrumentation, and contamination by damped Ly-α systems. We present improved measurements of the mean Ly-α transmission over 4.9 < z < 6.1. Using all known systematics in a forward modelling analysis, we find excellent agreement between the observed Ly-α transmission distributions and the homogeneous-UVB simulations Sherwood and Nyx up to z ≤ 5.2 (<1σ), and mild tension (∼2.5σ) at z = 5.3. Homogeneous UVB models are ruled out by excess Ly-α transmission scatter at z ≥ 5.4 with high confidence (>3.5σ). Our results indicate that reionization-related fluctuations, whether in the UVB, residual neutral hydrogen fraction, and/or IGM temperature, persist in the intergalactic medium until at least z = 5.3 (t = 1.1 Gyr after the big bang). This is further evidence for a late end to reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Metrology and Standards Gaps and FY27 Work Focusing on Impact

This work focuses on the Heliostat Consortium (HelioCon) optical measurements and characterization, testing and modeling capabilities and infrastructure at NLR and Sandia supporting heliostat technology research, development, validation, and deployment in relevant industries. The development of standards in HelioCon requires a collective effort across the global heliostat community of industry, researchers, academia and other stakeholders.

14 SOLAR ENERGY↗

Estimation of Sea Spray Aerosol Surface Area Over the Southern Ocean Using Scattering Measurements

This study focuses on methods to estimate dry marine aerosol surface area (SA) from bulk optical measurements. Aerosol SA is used in many models' ice nucleating particle (INP) parameterizations, as well as influencing particle light scattering, hygroscopic growth, and reactivity, but direct observations are scarce in the Southern Ocean (SO). Two campaigns jointly conducted in austral summer 2018 provided co-located measurements of aerosol SA from particle size distributions and lidar to evaluate SA estimation methods in this region. Mie theory calculations based on measured size distributions were used to test a proposed approximation for dry aerosol SA, which relies on estimating effective scattering efficiency (Q) as a function of Ångström exponent (å). For distributions with dry å < 1, Q = 2 was found to be a good approximation within ±50%, but for distributions with dry å > 1, an assumption of Q = 3 as in some prior studies underestimates dry aerosol SA by a factor of 2 or more. We propose a new relationship between dry å and Q, which can be used for –0.2 < å < 2, and suggest å = 0.8 as the cutoff between primary and secondary marine aerosol-dominated distributions. Application of a published methodology to retrieve dry marine aerosol SA from lidar extinction profiles overestimated aerosol SA by a factor of 3–5 during these campaigns. Using Microtops aerosol optical thickness measurements, we derive alternative lidar conversion parameters from our observations, applicable to marine aerosol over the SO.

54 ENVIRONMENTAL SCIENCES↗

Ultrafast Terahertz Field Control of the Emergent Magnetic and Electronic Interactions at Oxide Interfaces

Ultrafast electric-field control of emergent electronic and magnetic states at oxide interfaces offers exciting prospects for the development of the next generation of energy-efficient devices. Here, it is demonstrated that the electronic structure and emergent ferromagnetic interfacial state in epitaxial LaNiO3/CaMnO3 superlattices can be effectively controlled using intense, single-cycle THz electric-field pulses. A suite of advanced X-ray spectroscopic techniques is employed to measure a detailed magneto-optical profile and the thickness of the ferromagnetic interfacial layer. Then, a combination of time-resolved and temperature-dependent optical measurements is used to disentangle several correlated electronic and magnetic processes driven by ultrafast, high-field THz pulses. Sub-picosecond non-equilibrium Joule heating of the electronic system is observed, ultrafast demagnetization of the ferromagnetic interfacial layer, and slower dynamics indicative of a change in the magnetic state of the superlattice due to the transfer of spin-angular momentum to the lattice. These findings suggest a promising avenue for the efficient control of 2D ferromagnetic states at oxide interfaces using ultrafast electric-field pulses.

X-ray spectroscopy and scattering↗

Unmanned Aerial Vehicle Path Generation for Image Collection to Assist Heliostat Field Optical Characterization

This paper focuses on applications of unmanned aerial vehicles (UAVs) for measuring optical error of heliostats in concentrating solar power (CSP) plants. In CSP, there is a need to measure solar-field optical errors, which is critical for future production improvement as well as for operations and maintenance of a heliostat field. This latter need is particularly challenging because of the large number of heliostats (over 10,000 for a utility-scale power plant) that individually track the sun in the field. To address this issue, a camera-equipped UAV, with an optimized drone flight path developed and uploaded to it, collects images of a precise reflection of the tower on each heliostat to evaluate optical error sources without interrupting plant operation. Generation of the drone path for capturing the reflected images is affected by a number technical and realistic constraints, which include the camera angle used to capture the image, the blocking of the camera view due to surrounding heliostats, the location of the camera in reference to the target heliostat, and the target heliostat position with reference to the tower. The effect of these constraints on calculating the camera position will be discussed in detail in this article. An effective drone-path algorithm is generated to fulfil the need of image collection under various constraints.

concentrated solar power↗

Subnanometer Visualization of Spatially Varying Local Field Resonances that Drive Tip-Enhanced Optical Spectroscopy

Our knowledge of the electromagnetic fields that power modern nanoscale optical measurements, including (non)linear tip-enhanced Raman and photoluminescence, chiefly stems from numerical simulations. Aside from idealized in silico vs heterogeneous (nano)structures in the laboratory, challenges in quantitative descriptions of nanoscale light–matter interactions more generally stem from the very nature of the problem, which lies at the interface of classical and quantum theories. This is particularly the case in ultrahigh spatial resolution measurements that are sensitive to local optical field variations that take place on subnanometer length scales. Here this work approaches this challenge through extinction-based spectral nanoimaging experiments. We demonstrate <1 nm spatial resolution in hyperspectral extinction measurements that track spatially varying plasmon resonances. We describe the principles behind our experiments and highlight more general implications of our observations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Depth Thermography: Noninvasive 3D Temperature Profiling Using Infrared Thermal Emission

Here, we introduce a technique based on infrared thermal emission, termed depth thermography, that can remotely measure the temperature distribution beneath the surface of certain objects. Depth thermography utilizes the thermal-emission spectrum in the semitransparent spectral region of the target object to extract its temperature as a function of depth, in contrast with conventional thermography, which uses the spectrally integrated thermally emitted power to measure the surface temperature. Coupled with two-dimensional imaging, for example using an infrared hyperspectral camera or scanning a single-pixel spectrometer, this technique can yield volumetric temperature distributions. Furthermore, we carried out a proof-of-concept experiment on an asymmetrically heated fused-silica window, extracting the temperature distribution throughout the sample. Depth thermography may enable noncontact volumetric temperature measurements of microscopic objects such as multilayer electronic devices or macroscopic volumes of liquids and gases, as well as simultaneous all-optical measurements of optical and thermal properties of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interactions Enhance Ramp Reversal Memory in Locally Phase Separated Materials

The ramp-reversal memory (RRM) effect in metal–insulator transition metal oxides (TMOs), a non-volatile resistance change induced by repeated temperature cycling, has attracted considerable interest in neuromorphic computing and non-volatile memory devices. Our previous defect motion model successfully explained RRM in vanadium dioxide (VO 2 ), capturing observed critical temperature shifts and memory accumulation throughout the sample. However, this approach lacked interactions between metallic and insulating domains. Here, we extend our model by combining a correlated Random Field Ising Model with defect diffusion-segregation, enabling accurate hysteresis modeling while predicting the relationship between RRM and domain interactions. Our simulations demonstrate that the maximum RRM occurs when the turnaround temperature approaches the inflection point. This peak in RRM vs. turnaround temperature is consistent with prior transport measurements, as well as our own optical measurements reported here. Significantly, we find that increasing nearest-neighbor interactions enhances the maximum memory effect, thus providing a clear mechanism for optimizing RRM performance. Since our model employs minimal assumptions, we predict that RRM should be a widespread phenomenon in materials exhibiting patterned phase coexistence of electronic domains. This work not only advances fundamental understanding of memory behavior in TMOs but also establishes a much-needed theoretical framework for optimizing device applications.

36 MATERIALS SCIENCE↗

Heliostat error detection

The present disclosure describes non-intrusive optical (NIO) characterization methods which efficiency measures optical errors (such as mirror surface slope error, mirror canting error, and heliostat tracking error) of a heliostat field. The methods utilize photogrammetry and deflectometry to analyze an image taken of a heliostat to determine optical errors and increase the amount of solar energy delivered by the heliostat to the receiver.

Zhu, Guangdong↗

Quantum Enhanced Probes of Magnetic Circular Dichroism

Magneto-optical microscopies, including optical measurements of magnetic circular dichroism, are increasingly ubiquitous tools for probing spin-orbit coupling, charge-carrier g-factors, and chiral excitations in matter, but the minimum detectable signal in classical magnetic circular dichroism measurements is fundamentally limited by the shot-noise limit of the optical readout field. Here, a two-mode squeezed light source is used to improve the minimum detectable signal in magnetic circular dichroism measurements by 3 decibels compared with state-of-the-art classical measurements, even with relatively lossy samples like terbium gallium garnet. Furthermore, these results provide a framework for new quantum-enhanced magneto-optical microscopies that are particularly critical for environmentally sensitive materials and for low temperature measurements where increased optical power can introduce unacceptable thermal perturbations.

42 ENGINEERING↗

The DEHVILS in the details: Type Ia supernova Hubble residual comparisons and mass step analysis in the near-infrared

Measurements of type Ia supernovae (SNe Ia) in the near-infrared (NIR) have been used both as an alternate path to cosmology compared to optical measurements and as a method of constraining key systematics for the larger optical studies. With the DEHVILS sample, the largest published NIR sample with consistent NIR coverage of maximum light across three NIR bands ( Y, J , and H ), we check three key systematics: (i) the reduction in Hubble residual scatter as compared to the optical, (ii) the measurement of a “mass step” or lack thereof and its implications, and (iii) the ability to distinguish between various dust models by analyzing slopes and correlations between Hubble residuals in the NIR and optical. We produce SN Ia simulations of the DEHVILS sample and find that it is harder to differentiate between various dust models than previously understood. Additionally, we find that fitting with the current SALT3-NIR model does not yield accurate wavelength-dependent stretch-luminosity correlations, and we propose a limited solution for this problem. From the data, we see that (i) the standard deviation of Hubble residual values from NIR bands treated as standard candles are 0.007–0.042 mag smaller than those in the optical, (ii) the NIR mass step is not constrainable with the current sample size of 47 SNe Ia from DEHVILS, and (iii) Hubble residuals in the NIR and optical are correlated in the data. We test a few variations on the number and combinations of filters and data samples, and we observe that none of our findings or conclusions are significantly impacted by these modifications.

Astronomy & Astrophysics↗