Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Outlook for active plasma spectroscopy with entangled two-photon absorption

Entangled two-photon absorption (ETPA) exhibits a quantum-enhanced two-photon absorption cross-section and a linear scaling with incident power that exceeds classical two-photon absorption (TPA) at low photon flux. Here, we assess the feasibility and applications of ETPA for active plasma spectroscopy. The ETPA-absorbed power for an Ar + species in a helicon plasma scenario is calculated to be as high as 0.6 nW cm −1 along the incident beam path for nondegenerate-entangled photon pairs that are near-resonant with an intermediate level. The ETPA absorption power exceeds classical TPA and Bremsstrahlung emission, a necessary condition for a feasible fluorescence measurement. Applications of ETPA plasma spectroscopy may include trace impurity detection, ground-state excitation, and continuous-wave pumping for high-bandwidth turbulence measurements. Possible benefits of plasma measurements are less harm to optical components with lower incident flux and reduced stray light that can contaminate optical diagnostics.

active plasma spectroscopy↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Detection of Nitrogen and Neon in the X-ray Spectrum of GP Com with XMM/Newton

We report on X-ray spectroscopic observations with XMM/Newton of the ultra-compact, double white dwarf binary, GP Com. With the Reflection Grating Spectrometers (RGS) we detect the L(alpha) and L(beta) lines of hydrogen-like nitrogen (N VII) and neon (Ne X), as well as the helium-like triplets (N VI and Ne IX) of these same elements. All the emission lines are unresolved. These are the first detections of X-ray emission lines from a double-degenerate, AM CVn system. We detect the resonance (r) and intercombination (i) lines of the N VI triplet, but not the forbidden (f) line. The implied line ratios for N VI, R = f/i less than 0.3, and G = (f + i ) / r approx. = 1, combined with the strong resonance line are consistent with a dense, collision-dominated plasma. Both the RGS and EPIC/MOS spectra are well fit by emission horn an optically thin thermal plasma with an emission measure (EM) is a member of (kT/6.5 keV)(sup 0.8) (model cevmkl in XSPEC). Helium, nitrogen, oxygen and neon are required to adequately model the spectrum, however, the inclusion of sulphur and iron further improves the fit, suggesting these elements may also be present at low abundance. We confirm in the X-rays the under- abundance of both carbon and oxygen relative to nitrogen, first deduced from optical spectroscopy by Marsh et al. The average X-ray luminosity of approx. = 3 x 10(exp 30) ergs/s implies a mass accretion rate dot-m approx. = 9 x 10(exp -13) solar mass/yr. The implied temperature and density of the emitting plasma, combined with the presence of narrow emission lines and the low dot-m value, are consistent with production of the X-ray emission in an optically thin boundary layer just above the surface of the white dwarf.

Strohmayer, Tod E.↗

High Current Hollow Cathode Plasma Plume Measurements

Plasma plume measurements are reported for a hollow cathode assembly (HCA) operated at discharge currents of 50, 70, and 100 A at xenon flow rates between 19 - 46 standard cubic centimeter per minute. The HCA was centrally mounted in the NASA-300MS Hall Thruster and was operated in the "spot" and "plume" modes with additional data taken with an applied magnetic field. Langmuir probes, retarding potential analyzers, and optical emission spectroscopy were employed to measure plasma properties near the orifice of the HCA and to assess the charge state of the near-field plasma. Electron temperatures (2-6 electron volt) and plasma potentials are consistent with probe-measured values in previous investigations. Operation with an applied-field yields higher discharge voltages, increased Xe III production, and increased signals from the 833.5 nm C I line. While operating in plume mode and with an applied field, ion energy distribution measurements yield ions with energies significantly exceeding the applied discharge voltage. These findings are correlated with high-frequency oscillations associated with each mode.

High frequency analysis↗

Plasma interactions in the Space Shuttle Orbiter environment

Attempts to measure the ambient ionospheric plasma environment in the vicinity of the payload bay of the Space Shuttle Orbiter have shown that the plasma is quite different, in a variety of characteristics, from the ionospheric plasma at low earth orbit altitudes. It appears that the large size, complex geometry and various outgassing characteristics of a typical Orbiter payload can all contribute to modifications of the plasma environment of the Space Shuttle Orbiter. The measurements indicate that the plasma is often quite turbulent and contains populations more energetic than the ambient ionospheric plasma. Pronounced wake and ram effects have been observed, and at times the data can be interpreted as plasma number density enhancements of an order of magnitude or greater over the ambient, undisturbed plasma concentration. There is evidence that this enhanced plasma concentration contains molecular ions, not occurring naturally at low earth orbit altitudes. In addition to describing the observations, the electrodynamics of enhanced Orbiter-generated plasma and its possible impact on optical measurements from the Space Shuttle Orbiter will be discussed.

Raitt, W. J.↗

Combined microwave and laser Rayleigh scattering diagnostics for pin-to-pin nanosecond discharges

In this work, the temporal decay of electrons produced by an atmospheric pin-to-pin nanosecond discharge operating in the spark regime was measured via a combination of microwave Rayleigh scattering (MRS) and laser Rayleigh scattering (LRS). Due to the initial energy deposition of the nanosecond pulse, a variation in the local gas density occurs on the timescale of electron decay. Thus, the assumption of a constant collisional frequency is no longer applicable when electron number data are extracted from MRS measurements. Furthermore, to recalibrate MRS measurements throughout the electron decay period, temporally resolved LRS measurements of the local gas density were performed over the event duration. The local gas density was calculated to be 30% of the ambient level during the later stages of electron decay, and it recovers at about 1 ms after discharge. A shock front traveling approximately 500 m/s was additionally observed. Coupled with plasma volume calibration via temporally resolved intensified charge-coupled device imaging, the corrected decay curves of the electron number and electron number density are presented with a measured peak electron number density of 4.5 × 1015 cm -3 and a decay rate of ~(0.1–0.35) × 10 7 s -1 . A hybrid MRS and LRS diagnostic technique can be applied for a broad spectrum of atmospheric-pressure microplasmas where a variation in the gas number density is expected due to energy deposition in the discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

FINAL REPORT

Explore the source record for details and available documents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Downward-deployed tethered satellite systems, measurement techniques, and instrumentation - A review

This paper describes a number of scheduled and proposed Shuttle-based downward-deployed tethered satellite systems (TSSs) the purpose of which is to determine the structure of the lower thermosphere and to measure the atmospheric and aerodynamic effects in the vicinity of the satellite, the aerothermodynamic effects on the satellite's surface, and the dynamics of the tether and its endmass, the satellite. The instruments for the downward-deployed tethered missions will include mass spectrometers and other density sensors, plasma instrumentation, optical spectrophotometers, magnetometers, and instrumentation to measure the effects on satellite surface (such as the surface temperature, heat transfer, and pressure; gas adsorption on surfaces, chemistry with other gas molecules and surface material, and desorption from the surface; and surface charging).

Brown, Kenneth G.↗

Density evolution after shock release from laser-driven polystyrene (CH) targets in inertial confinement fusion

The evolution of the plasma density in the rarefaction wave formed after a laser-driven shock is released from a CH foil was measured using optical interferometry. Here, it was found that the plasma density profile is very sensitive to the conditions at the back surface of the foil before the shock release. Dedicated experiments demonstrated that radiation preheat by coronal x-rays caused early expansion of the back surface and faster expansion of the rarefaction wave. Radiation-hydrodynamics simulations with accurate modeling of radiation preheat from the plasma corona are in good agreement with the experimental results. The early expansion of material interfaces due to coronal x-ray preheat must be evaluated in designing and interpreting laser-driven inertial confinement fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics Explorer measurements of particles, fields, and plasma drifts over a horse-collar auroral pattern

As shown from ground-based measurements and satellite-borne imagers, one type of global auroral pattern characteristic of quiet (usually northward IMF) intervals is that of a contracted but thickened emission region in which the dawn and dusk portions can spread poleward to very high latitudes, (the type of a pattern referred to as a 'horse-collar' aurora by Hones et al., 1989). In this report we use a DE data set to examine a case in which this horse-collar pattern was observed by the DE-1 auroral imager while at the same time the DE-2, at lower altitude, measured precipitating particles, electric and magnetic fields, and plasma drifts. There is close agreement between the optical signatures and the particle precipitation patterns. The particle, plasma, and field measurements made along the satellite track and the 2-D perspective of the imager provide a means of determining the configuration of convective flows in the high-latitude ionosphere during this interval of northward IMF. Recent mapping studies are used to relate the low-altitude observations to possible magnetospheric source regions.

Sharber, J. R.↗

The mass and speed dependence of meteor air plasma temperatures

The speed and mass dependence of meteor air plasma temperatures is perhaps the most important data needed to understand how small meteoroids chemically change the ambient atmosphere in their path and enrich the ablated meteoric organic matter with oxygen. Such chemistry can play an important role in creating prebiotic compounds. The excitation conditions in various air plasma emissions were measured from high-resolution optical spectra of Leonid storm meteors during NASA's Leonid Multi-Instrument Aircraft Campaign. This was the first time a sufficient number and range of temperature measurements were obtained to search for meteoroid mass and speed dependencies. We found slight increases in temperature with decreasing altitude, but otherwise nearly constant values for meteoroids with speeds between 35 and 72 km/s and masses between 10(-5) g and 1 g. We conclude that faster and more massive meteoroids produce a larger emission volume, but not a higher air plasma temperature. We speculate that the meteoric plasma may be in multiphase equilibrium with the ambient atmosphere, which could mean lower plasma temperatures in a CO(2)-rich early Earth atmosphere.

Temperature↗

Understanding the depletion of electrons in dusty plasmas at atmospheric pressure

The nucleation and growth of NPs in the gas phase using atmospheric-pressure plasma systems is an important approach to synthesizing novel dimensionally-controlled materials. In this paper, we investigated the effect of the NPs on a typical type of continuous-flow, substrate-free plasma at atmospheric pressure to understand their potential contribution to electron density changes. A tandem plasma system was set up consisting of one plasma reactor that produced carbonaceous NPs from mixtures of argon and hexane, and another identical plasma reactor where the as-grown particles were injected and non-intrusive electrical and optical measurements were performed. The electron densities obtained from conductivity measurements and a plasma fluid model were found to decrease in the presence of NPs. However, control experiments revealed that the main source of the electron depletion was residual vapor or reaction byproducts in the form of molecular species or nanoclusters and not the particles themselves. These results were validated by constant number Monte Carlo simulations which showed that at the experimentally-measured conditions, the NPs were not of sufficiently high enough concentration to reduce the electron density; however, if molecules or clusters are ionizable, they remain in sufficient concentration to deplete electron densities. Our study shows that at atmospheric pressure, because of their typically larger electron density values, particle-producing plasmas are distinct from those at low pressure, and nanoparticle formation does not have the same impact while molecular-scale species may be a more important consideration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond ultraviolet laser absorption spectroscopy for simultaneous measurements of temperature and OH concentration

This Letter reports a femtosecond ultraviolet laser absorption spectroscopy (fs-UV-LAS) for simultaneous in situ measurements of temperature and species. Here, this fs-UV-LAS technique was demonstrated based on X 2 Π-A 2 Σ + transitions of OH radicals near 308 nm generated in low temperature plasmas and flames. The fs-UV-LAS technique has revealed three major diagnostic benefits. First, a series of absorption features within a spectral bandwidth of ~3.2 nm near 308 nm were simultaneously measured and then enabled simultaneous multi-parameter measurements with enhanced accuracy. The results show that the temperature and OH concentration could be measured with accuracy enhanced by 29–88% and 58–91%, respectively, compared to those obtained with past two-narrow-line absorption methods. Second, an ultrafast time resolution of ~120 picoseconds was accomplished for the measurements. Third, due to the large OH X 2 Π-A 2 Σ + transitions in the UV range, a simple single-pass absorption with a 3-cm path length was allowed for measurements in plasmas with low OH number density down to ~2 × 10 13 cm –3 . Also due to the large OH UV transitions, single-shot fs absorption measurements were accomplished in flames, which was expected to offer more insights into chemically reactive flow dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of CO 4th Positive Radiation in CO2-Ar Mixtures

This paper presents measurements and simulations of CO 4th Positive spectra obtained in NASA Ames Research Center's Electric Arc Shock Tube (EAST) and CentraleSupelec's Plasma Torch. The experiments were aimed at measuring optically thin emission for the main band features of CO 4th Positive by using test gas mixtures of CO2 and Ar. By using mixtures of CO2 and Ar, the temperature of the flow (and consequently black-body curve) is increased compared to using pure CO2 (or CO2 / N2 mixtures). This temperature increase allows for emission spectroscopy of features that would nominally be black-body limited for conditions relevant to Mars entry. The CO 4th Positive system is the focus of this study as it accounts for a large percentage of the emitted radiation for Martian entry, and also due to the difficulties of obtaining experimental validation data due to the emission appearing in the Vacuum Ultraviolet (VUV) spectral range. The focus of this paper is to provide a comprehensive comparison between the EAST and plasma torch data along with various CO 4th Positive databases available in the literature. Previously reported VUV CO2 / N2 EAST data required a larger temperature than would be predicted based upon equilibrium shock relations. The need for the temperature increase implies that the EAST experiment did not fully equilibrate. Thus, it is presumed that the EAST data did not obtain an equilibrium condition. The plasma torch data, on the other hand, is very consistent with equilibrium assumptions. Thus, the equilibrium data obtained in the plasma torch is utilized to construct the CO 4th Positive emission model, which is then applied to the EAST data with a non-equilibrium interpretation.

A. M. Brandis↗

Conceptual design and performance predictions for 2D beam emission spectroscopy turbulence measurements at Wendelstein 7-X

A conceptual design for a 2D beam emission spectroscopy diagnostic system to measure ion gyro-scale plasma turbulence at Wendeslstein 7-X is described. The conceptual design identifies field-aligned viewing geometries and ports for cross-field turbulence measurements in the neutral beam volume. A 2D sightline grid covers the outer plasma region, and the grid configuration provides sufficient k-space coverage in radial and poloidal directions for ion temperature gradient and trapped-electron mode turbulence measurements. Emission intensity estimates, optical transmission losses, and detector noise levels indicate that the measurements will be sensitive to plasma density fluctuations as small as δn/n ≈ 0.5% with a bandwidth of 1 MHz. Implementation challenges include a small beam emission Doppler shift due to nearly radial heating beams and reduced optical throughput due to collection aperture limitations.

47 OTHER INSTRUMENTATION↗