Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗

Topological controls on aluminosilicate glass dissolution: Complexities induced in hyperalkaline aqueous environments

Abstract Fly ash, an aluminosilicate composite consisting of disordered (major) and crystalline (minor) compounds, is a low‐carbon alternative that can partially replace ordinary portland cement (OPC) in the binder fraction of concrete. Therefore, understanding the reactivity of fly ash in the hyperalkaline conditions prevalent in concrete is critical to predicting concrete's performance; including setting and strength gain. Herein, temporal measurements of the solution composition (using inductively coupled plasma‐optical emission spectrometry: ICP‐OES) are used to assess the aqueous dissolution rate of monophasic synthetic aluminosilicate glasses analogous to those present in technical fly ashes, under hyperalkaline conditions (10 ≤ pH ≤ 13) across a range of temperatures (25°C ≤ T≤45°C). The dissolution rate is shown to depend on the average number of topological constraints per atom within the glass network (n c , unitless), but this dependence weakens with increasing pH (>10). This is postulated to be on account of: (a) time‐dependent changes in the glass’ surface structure, that is, the number of topological constraints; and/or (b) a change in the dissolution mechanism (eg from network hydrolysis to transport control). The results indicate that the topological description of glass dissolution is most rigorously valid only at very short reaction times (ie at high undersaturations), especially under conditions of hyperalkalinity. These findings provide an improved basis to understand the underlying factors that affect the initial and ongoing reactivity of aluminosilicate glasses such as fly ash in changing chemical environments, for example, when such materials are utilized in cementitious composites.

Oey, Tandré↗

Optical Imaging of Laser-Driven Fast Electron Weibel-like Filamentation in Overcritical Density Plasma

We report on the measurement of filamented transport of laser-generated fast electron beams in near-critical density plasma. A relativistic intensity long-wave-infrared laser irradiated a hydrodynamically shaped helium gas flow at an electron density n e ≃ 10 25 m − 3 , generating a large flux of fast electrons that propagated beyond the critical surface. The beam-to-background electron density ratio was sufficiently high to drive growth of Weibel-like filamentation, which was measured by optical probing to extend up to 800 μ m with radii ∼ 10 μ m . Particle-in-cell simulations reproduce the main features of the filamentation generation, suggesting that collisionless processes are dominant in these interactions. Expansion of the filaments after formation infers a fast electron heated plasma temperature ∼ 400 eV in the overcritical density plasma. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Multimodal study of the impact of stimulation pH on shale pore structure, with an emphasis on organics behavior in alkaline environments

The tight nature of shale formations calls for hydraulic fracturing techniques able of altering the pore architecture to facilitate the production of hydrocarbon resources. The composition, pH, salinity, density and chemistry of Hydraulic Fracturing Fluids (HFF) vary substantially depending on reservoir characteristics. pH is among the most important stimulation fluid properties, ranging from very acidic, for carbonate reservoirs, to basic, in the case of clay-rich formations. pH regulates what geochemical reactions take place between the stimulation fluid and shale, as well as pore architecture alteration. The dissolution of carbonates and pyrite, and the precipitation of common minerals such as barite, gypsum and iron oxides in acidic environments have been extensively documented. In contrast, alkali stimulation environments and the role of organic components have received less attention. This research provides insight into the role of both minerals and organic components during alkaline stimulation, and the resulting pore architecture alterations. Here, a set of reactive experiments are performed using three different shales, with varying organic matter (OM) content, at different pH (3, 6, 8, 10, 12). The analysis of pore architecture alteration induced by the reaction was performed via nitrogen (N2) gas adsorption and Time-Domain Nuclear Magnetic Resonance (TD-NMR). Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) was used to measure the composition of the stimulation fluid post-reaction. The system with a larger impact on the pore architecture (pH 12) underwent a more extensive analysis through the application of Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) and x-ray Diffraction (XRD). Results show that mineral dissolution contributed to the creation of secondary porosity, mainly through dissolution of clays and silicates. We show that the abundance and distribution of organic matter both play a significant role in changes in pore architecture. Most samples showed an increase in inter-organic porosity, likely due to the organic acids within kerogen reacting with the stimulation fluid. Samples with a larger amount and more widespread distribution of organic matter show the most significant alterations. Finally, we also highlight the dissolution process of iron-rich minerals, including framboidal pyrite, as another important source of secondary porosity.

04 OIL SHALES AND TAR SANDS↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute electron density fluctuation reconstruction for two-dimensional hydrogen beam emission spectroscopy

Scrape-off layer (SOL) and edge plasma turbulence significantly contribute to the radial particle and heat transport, lowering the plasma confinement and increasing the heat load on the plasma facing components. SOL turbulence is predominantly intermittent, which manifests in the occurrence of isolated density filaments or blobs. Filaments propagate radially outward toward plasma facing components, limiting their lifetime by erosion and sputtering. To characterize this phenomenon in detail, few diagnostic techniques are available. Beam emission spectroscopy is a diagnostic capable of measuring plasma turbulence in both SOL and edge plasmas. Due to the finite lifetime of the excitation states during the beam–plasma interaction and the misalignment between the optics and the magnetic field, spatial smearing is introduced in the measurement. In this paper, a novel method is introduced to overcome this hindering effect by inverting the fluctuation response matrix on an optimally smoothed signal. We show that this method is fast and provides significantly more accurate absolute density fluctuation reconstruction than the direct inversion technique. Here, the presented method is usable for all types of beam emission diagnostics where the spatial resolution is higher than the combined smearing of the atomic physics and the observation.

47 OTHER INSTRUMENTATION↗

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

Investigation of impurity driven corrosion behavior in molten 2LiF-BeF 2 salt

A 1000 -h corrosion experiment of 316H stainless steel at 700 °C investigated the role of metal fluoride impurities CrF 2 and FeF 2 in LiF-BeF 2 (66-34 mole %) (FLiBe) salt. Inductively coupled plasma-optical emission spectroscopy (ICP-OES) demonstrated the ability to measure changes in the concentration of these fluorides in FLiBe salt. Cyclic voltammetry (CV) showed the potential for real-time quantitative concentration measurement of corrosion products in the molten salt. Materials characterization revealed that both impurity species influence the dissolution of Cr from the alloy. The collective results from these analysis methods advance the understanding of the influence impurities have on materials corrosion.

2LiF-BeF2↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

Design Considerations to Ensure Robustness of the ITER Diagnostics Residual Gas Analyzer

Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.

Quinlan, Brendan↗

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Accelerated microwave-assisted synthesis and in situ X-ray scattering of tungsten-substituted vanadium dioxide (V 1-x W x O 2 )

Vanadium dioxide (VO 2 ) has been widely studied due to its metal-insulator phase transition at 68°C, below which it is a semiconducting monoclinic phase, P2 1 /c, and above it is a metallic tetragonal phase, P4 2 /mnm. Substituting vanadium with transition metals allows transition temperature tunability. An accelerated microwave-assisted synthesis for VO 2 and 5d tungsten substituted VO 2 presented herein decreased synthesis time by three orders of magnitude while maintaining phase purity, particle size, and transition character. Tungsten substitution amount was determined using inductively coupled plasma-optical emission spectroscopy. Differential scanning calorimetry, superconducting quantum interference device measurements, and in-situ heating and cooling experiments monitored through synchrotron x-ray diffraction (XRD) confirmed the transition temperature decreased with increased tungsten substitution. Scanning electron microscopy analyzed through the line-intercept method produced an average particle size of 3 – 5 μm. Average structure and local structure phase purity was determined through Rietveld analysis of synchrotron XRD and least-squares refinement of pair-distribution function data.

36 MATERIALS SCIENCE↗

Elemental Analysis of Bio-Oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Laboratory Analytical Procedure (LAP), Issue Date: May 13, 2022

Concentrations of inorganic elements is a key quality metric for bio-oils as certain elements impact upgrading processes and product quality. Unless reduced or removed during production and processing, alkali and alkaline metals native to lignocellulosic biomass can carry over into bio-oils contributing to ash content and degraded catalyst performance during upgrading to hydrocarbon fuels or chemical products. Non-metallic elements such as sulfur and phosphorus can also negatively impact upgrading catalysts and product quality. Inductively coupled plasma optical emission spectroscopy (ICP-OES) can be used to measure inorganic elements of interest in bio-oils. This procedure covers the preparation and analysis of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils. The concentrations of these elements can indicate potential bio-oil quality from the perspective of deoxygenation processes. The implications of elemental composition will depend on process parameters such as upgrading catalyst sensitivities. This Laboratory Analytical Procedure (LAP) covers two methods for quantification of inorganic elements by ICP-OES: Procedure A uses microwave assisted digestion with concentrated nitric acid, and Procedure B is an organic ICP-OES method utilizing a diglyme solvent.

09 BIOMASS FUELS↗

Chemical durability assessment of enhanced low-activity waste glasses through EPA method 1313

In this work, we report the progress of the Glass Leaching Assessment for Durability (GLAD) program on the implementation of the United States Environmental Protection Agency (EPA) Leaching Environmental Assessment Framework pH-dependent leach test (EPA Method 1313) to low-activity nuclear waste (LAW) glasses. The GLAD program seeks to develop new strategies to understand the chemical durability of nuclear waste glasses for the disposal in near-surface conditions. A series of 16 high-waste loading LAW glasses, currently under development, were selected using machine learning methods to study the corrosion behavior using EPA Method 1313. Reacted glass powders were examined using scanning electron microscopy and the eluate compositions were examined using inductively coupled plasma-optical emission spectroscopy. Compositional modeling was used to fit the measured elemental releases from EPA Method 1313. The compositional models demonstrated that elements such as Si reduce elemental release while B can increase elemental release (consistent with elemental modeling of the Product Consistency Test and Vapor Hydration Test) while other elements, such as Fe, exhibit pH-dependent behavior. The amount of acid added during the EPA testing was found to significantly impact the observed result, which was only apparent after preforming the present matrix study. The overall titration curves were able to be compositionally modeled for future process optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge

Toroidal current profile measurements in the tokamak plasma edge are critical for fusion plasma physics research and model validation. A three-wave Faraday-effect polarimeter-interferometer with a sub-centimeter spatial resolution is proposed on the DIII-D tokamak to determine the edge current profile via Abel inversion. By using probe beams with 316 µm wavelength, a low-field-side, vertical-view, single-pass optical layout covering the plasma edge region (R = 2.15–2.27 m) is assessed. Measurements with no greater than 0.1° polarimetric systematic uncertainty, no greater than 0.01° polarimetric root-mean-square noise (1 kHz bandwidth), and a 0.8 cm radial chord spacing are considered feasible based on the achieved performance of existing systems using similar wavelengths on fusion devices. Furthermore, synthetic diagnostic calculations taking various factors into account, such as diagnostic uncertainty and quality of magnetic flux surfaces, find that the edge current profile can be determined with up to 0.12 MA/m 2 uncertainty, or about 10% of the peak current density in the pedestal of an investigated high-confinement plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗