Search NASA⌕ Search

SEARCH · Search NASA

Results for “Organic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Genetic algorithm optimization of tin–copper graded shielding for improved plutonium safeguards measurements

Plutonium nuclear material safeguards is essential to ensure that states do not divert plutonium to clandestine nuclear weapons programs. Traditional safeguards methods rely on correlated neutron measurements. Detection systems based on organic scintillators, which are sensitive to fast neutrons and photons, are gaining support for use in safeguards applications due to increased capabilities and shorter measurement times compared to the current state-of-the-art. A drawback of organic scintillators in plutonium measurements is data throughput limitations; 241 Am builds up in plutonium samples and emits 60-keV gamma rays with a high specific activity. In this work, a genetic algorithm is used to design graded shielding made of tin and copper to attenuate the 60-keV gamma rays. The shield is designed to limit the attenuation of the higher-energy, fission photons, because fission photons can be used as a signature. The genetic algorithm optimization takes days to run, while a complete search space exploration would take years. The genetic algorithm was run for different levels of 60-keV gamma-ray attenuation, and the thickness of the required shielding layers was determined at each level. Tin–copper shielding was placed in front of an array of organic scintillation detectors for a measurement of approximately 4.5 kg of alpha-phase, weapons-grade plutonium, an AmLi source, and a 252 Cf source. We show that the shield successfully attenuated low-energy, non-fission gamma rays, which significantly improved the organic scintillator performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Absolute light yield of the EJ-204 plastic scintillator

The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $γ$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 ± 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative analysis of new crystal and plastic scintillators for fast and thermal neutron detection

This paper considers scintillation and physical properties of efficient organic scintillators tested as single crystals and as components of plastics with pulse shape discrimination (PSD). For the first time, single crystals of 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) were grown for studies of the basic scintillation properties of this new compound. Comparison to classical organic crystals, like anthracene, trans-stilbene, and p-terphenyl, and to more recently introduced organic glass showed that the new crystal belongs to a group of the most efficient scintillators, with light output exceeding that of trans-stilbene and PSD comparable to that of p-terphenyl. Furthermore, additional studies were conducted to evaluate scintillation performance and physical properties, like hardness and dye leaching, of plastic scintillators prepared with PhF, organic glass, and liquid diisopropylnaphthalene (DIPN) that were considered as examples for potential replacement of PPO (2,5-diphenyloxazole) in current commercial PSD plastic scintillators. Comparison of the highest performing plastic scintillators prepared with these dyes shows that PhF formulations produced a record light output (LO) increase of 69 % relative to EJ-200. Similar improvements obtained with 6 Li-loaded formulations showed that future development of PSD plastics should not be limited to use of PPO but must involve the search and exploration of new efficient dyes that may lead to discovery of much brighter organic scintillators with improved physical properties required for fast and thermal neutron detection, fast neutron spectroscopy, and antineutrino detection applications.

9,9-dimethyl-2-phenyl-9H-fluorene↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Multiplicity Counting Diagnosis of Uranium Assemblies Interrogated by Cf-252 [Poster]

Researchers concluded: First neutron multiplicity counting of tens of kilograms of 235 U with organic scintillators; leakage multiplication estimates to be improved by incorporating detector cross-talk; provides data comparison for “Multiplicity Theory Beyond the Point Model;" promotes continued use of organic scintillators for NCERC and elsewhere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Expectation-propagation for weak radionuclide identification at radiation portal monitors

We propose a sparsity-promoting Bayesian algorithm capable of identifying radionuclide signatures from weak sources in the presence of a high radiation background. The proposed method is relevant to radiation identification for security applications. In such scenarios, the background typically consists of terrestrial, cosmic, and cosmogenic radiation that may cause false positive responses. We evaluate the new Bayesian approach using gamma-ray data and are able to identify weapons-grade plutonium, masked by naturally-occurring radioactive material (NORM), in a measurement time of a few seconds. We demonstrate this identification capability using organic scintillators (stilbene crystals and EJ-309 liquid scintillators), which do not provide direct, high-resolution, source spectroscopic information. Compared to the EJ-309 detector, the stilbene-based detector exhibits a lower identification error, on average, owing to its better energy resolution. Organic scintillators are used within radiation portal monitors to detect gamma rays emitted from conveyances crossing ports of entry. The described method is therefore applicable to radiation portal monitors deployed in the field and could improve their threat discrimination capability by minimizing “nuisance” alarms produced either by NORM-bearing materials found in shipped cargoes, such as ceramics and fertilizers, or radionuclides in recently treated nuclear medicine patients.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

High Multiplication Neutron Noise Measurements Using the 7uPCX Assembly

The Seven Percent Critical Experiment, or 7uPCX, is a system that mimics the physics of light water nuclear reactor systems by using uranium dioxide fuel pins at an enrichment of approximately 7%. 7uPCX is often used for benchmarking and nuclear data purposes. As part of a collaboration between Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, and the Institut de Radioprotection et de Sûreté Nucléaire, measurements were performed in support of a high-multiplication, subcritical benchmark candidate for a thermal system. The measurements were completed by making subcritical configurations using the fuel loading pattern of a well-documented configuration of the Seven Percent Critical Experiment at Sandia National Laboratories, which exists as a benchmark in the International Criticality Safety Benchmark Evaluation Project handbook. These measurements, which aimed to capture multiplications ranging from approximately 10 to 1,000, also serve as an intercomparison between both the fielded detector systems and analysis methodologies with the goal of better characterizing the detectors and their ability to capture the state of the criticality these types of systems. Los Alamos National Laboratory’s measurements for this collaboration were made with five linked helium-3 based neutron multiplicity detectors placed on the periphery of the reactor tank beyond the infinite reflector thickness of water, and four organic scintillators placed in dry-wells in-reactor near the edge of the upper fuel grid plate. This work captures the Los Alamos National Laboratory measurements, the Rossi-α and Feynman-Y results, provides an intercomparison between the results of the 3 He neutron detectors and the organic scintillators, compares to simulation where possible, and expands on future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗