Search NASA⌕ Search

SEARCH · Search NASA

Results for “Overall Cooling Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Crystallization during emplacement of lava flows

Thermal models of lava flows provide a way of estimating emplacement durations and eruption rates of planetary lava flows, which can help constrain magma ascent, rheology and composition. Most of the models that have been developed consider only the effects of cooling by radiation. However, heating due to crystallization can be a large component of the overall heat budget of a flow. Little is known about the amount of crystallization and latent heating during flow advance. Crystal size distribution (CSD) measurements were made to quantify and study the effects of crystallization in the 1984 Mauna Loa flow. For flows on Mars, we must assume that the amount of crystallization is similar to that in terrestrial flows and place minimum and maximum bounds on the latent heat effect. Unfortunately, as examples given here show, there can be anywhere from 0 to 60 percent crystallization during flow advance. To improve constraints for Martian flows, we need to search for correlations in terrestrial flows between flow morphology and the amount of crystallization during emplacement.

Crisp, J.↗

Daytime cooling efficiencies of urban trees derived from land surface temperature are much higher than those for air temperature

Accurately capturing the impact of urban trees on temperature can help optimize urban heat mitigation strategies. Recently, there has been widespread use of remotely sensed land surface temperature (T s ) to quantify the cooling efficiency (CE) of urban trees. However, remotely sensed T s reflects emitted radiation from the surface of an object seen from the point of view of the thermal sensor, which is not a good proxy for the air temperature (T a ) perceived by humans. The extent to which the CEs derived from T s reflect the true experiences of urban residents is debatable. Therefore, this study systematically compared the T s -based CE (CE T s ) with the T a -based CE (CE T a ) in 392 European urban clusters. CE T s and CE T a were defined as the reductions in T s and T a , respectively, for every 1% increase in fractional tree cover (FTC). The results show that the increase in FTC has a substantial impact on reducing T s and T a in most cities during daytime. However, at night, the response of T s and T a to increased FTC appears to be much weaker and ambiguous. On average, for European cities, daytime CE T s reaches 0.075 °C % -1 , which is significantly higher (by an order of magnitude) than the corresponding CE T a of 0.006 °C % -1 . In contrast, the average nighttime CE T s and CE T a for European cities are similar, both approximating zero. Overall, urban trees can lower daytime temperatures, but the magnitude of their cooling effect is notably amplified when using remotely sensed T s estimates compared to in situ T a measurements, which is important to consider for accurately constraining public health benefits. Our findings provide critical insights into the realistic efficiencies of alleviating urban heat through tree planting.

54 ENVIRONMENTAL SCIENCES↗

Comparison of different cooling regimes within a shortened liquid cooling/warming garment on physiological and psychological comfort during exercise

The aim of this study was to compare the effectiveness of different cooling regime intensities to maintain physiological and subjective comfort during physical exertion levels comparable to that engaged in during extravehicular activities (EVA) in space. We studied eight subjects (six males, two females) donned in our newly developed physiologically based shortened liquid cooling/warming garment (SLCWG). Rigorous (condition 1) and mild (condition 2) water temperature cooling regimes were compared at physical exertion levels comparable to that performed during EVA to ascertain the effectiveness of a lesser intensity of cooling in maintaining thermal comfort, thus reducing energy consumption in the portable life support system. Exercise intensity was varied across stages of the session. Finger temperature, rectal temperature, and subjective perception of overall body and hand comfort were assessed. Finger temperature was significantly higher in the rigorous cooling condition and showed a consistent increase across exercise stages, likely due to the restriction of heat extraction because of the intensive cold. In the mild cooling condition, finger temperature exhibited an overall decline with cooling, indicating greater heat extraction from the body. Rectal temperature was not significantly different between conditions, and showed a steady increase over exercise stages in both rigorous and mild cooling conditions. Ratings of overall comfort were 30% higher (more positive) and more stable in mild cooling (p<0.001). The mild cooling regime was more effective than rigorous cooling in allowing the process of heat exchange to occur, thus maintaining thermal homeostasis and subjective comfort during physical exertion.

NASA Discipline Life Sciences Technologies↗

Thermal Characteristics of Urban Landscapes

Although satellite data are very useful for analysis of the urban heat island effect at a coarse scale, they do not lend themselves to developing a better understanding of which surfaces across the city contribute or drive the development of the urban heat island effect. Analysis of thermal energy responses for specific or discrete surfaces typical of the urban landscape (e.g., asphalt, building rooftops, vegetation) requires measurements at a very fine spatial scale (i.e., less than 15 m) to adequately resolve these surfaces and their attendant thermal energy regimes. Additionally, very fine scale spatial resolution thermal infrared data, such as that obtained from aircraft, are very useful for demonstrating to planning officials, policy makers, and the general populace the benefits of the urban forest. These benefits include mitigating the urban heat island effect, making cities more aesthetically pleasing and more habitable environments, and aid in overall cooling of the community. High spatial resolution thermal data are required to quantify how artificial surfaces within the city contribute to an increase in urban heating and the benefit of cool surfaces (e.g., surface coatings that reflect much of the incoming solar radiation as opposed to absorbing it thereby lowering urban temperatures). The TRN (thermal response number) is a technique using aircraft remotely sensed surface temperatures to quantify the thermal response of urban surfaces. The TRN was used to quantify the thermal response of various urban surface types ranging from completely vegetated surfaces to asphalt and concrete parking lots for Huntsville, AL.

Luvall, Jeffrey C.↗

The Use of the Airborne Thermal/Visible Land Application Sensor (ATLAS) to Determine the Thermal Response Numbers for Urban Areas

Although satellite data are very useful for analysis of the urban heat island effect at a coarse scale, they do not lend themselves to developing a better understanding of which surfaces across the city contribute or drive the development of the urban heat island effect. Analysis of thermal energy responses for specific or discrete surfaces typical of the urban landscape (e.g., asphalt, building rooftops, vegetation) requires measurements at a very fine spatial scale (i.e., < 15m) to adequately resolve these surfaces and their attendant thermal energy regimes. Additionally, very fine scale spatial resolution thermal infrared data, such as that obtained from aircraft, are very useful for demonstrating to planning officials, policy makers, and the general populace the benefits of the urban forest. These benefits include mitigating the urban heat island effect, making cities more aesthetically pleasing and more habitable environments, and aid in overall cooling of the community. High spatial resolution thermal data are required to quantify how artificial surfaces within the city contribute to an increase in urban heating and the benefit of cool surfaces (e.g., surface coatings that reflect much of the incoming solar radiation as opposed to absorbing it thereby lowering urban temperatures). The TRN (thermal response number)(Luvall and Holbo 1989) is a technique using aircraft remotely sensed surface temperatures to quantify the thermal response of urban surfaces. The TRN was used to quantify the thermal response of various urban surface types ranging from completely vegetated surfaces to asphalt and concrete parking lots for several cities in the United States.

Luvall, Jeffrey C.↗

Climate cooling benefits of cellulosic bioenergy crops from elevated albedo

Abstract Changes in land surface albedo can alter ecosystem energy balance and potentially influence climate. We examined the albedo of six bioenergy cropping systems in southwest Michigan USA: monocultures of energy sorghum ( Sorghum bicolor ), switchgrass ( Panicum virgatum L.), and giant miscanthus ( Miscanthus × giganteus) , and polycultures of native grasses, early successional vegetation, and restored prairie. Direct field measurements of surface albedo ( α s ) from May 2018 through December 2020 at half‐hourly intervals in each system quantified the magnitudes and seasonal differences in albedo (∆ α ) and albedo‐induced radiative forcing (RF ∆ α ). We used a nearby forest as a historical native cover type to estimate reference albedo and RF ∆ α change upon original land use conversion, and a continuous no‐till maize ( Zea mays L .) system as a contemporary reference to estimate change upon conversion from annual row crops. Annually, α s differed significantly ( p < 0.05) among crops in the order: early successional (0.288 ± 0.012SE) >> miscanthus (0.271 ± 0.009) ≈ energy sorghum (0.270 ± 0.010) ≥ switchgrass (0.265 ± 0.009) ≈ restored prairie (0.264 ± 0.012) > native grasses (0.259 ± 0.010) > maize (0.247 ± 0.010). Reference forest had the lowest annual α s (0.134 ± 0.003). Albedo differences among crops during the growing season were also statistically significant, with growing season α s in perennial crops and energy sorghum on average ~20% higher (0.206 ± 0.003) than in no‐till maize (0.184 ± 0.002). Average non‐growing season (NGS) α s (0.370 ± 0.020) was much higher than growing season α s (0.203 ± 0.003) but these NGS differences were not significant. Overall, the original conversion of reference forest and maize landscapes to perennials provided a cooling effect on the local climate (RF αMAIZE : −3.83 ± 1.00 W m −2 ; RF αFOREST : −16.75 ± 3.01 W m −2 ). Significant differences among cropping systems suggest an additional management intervention for maximizing the positive climate benefit of bioenergy crops, with cellulosic crops on average ~9.1% more reflective than no‐till maize, which itself was about twice as reflective as the reference forest.

Lei, Cheyenne↗

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Effective properties of semitransparent radiative cooling materials with spectrally variable properties

Radiative cooling is a promising solid-state, non-vapor-compression technology for passive refrigeration and air conditioning. Although this phenomenon occurs naturally, achieving a significant amount of cooling to make it a technically and economically viable technology requires highly engineered, spectrally selective radiative surfaces. These characteristics make radiative cooling difficult to estimate, particularly when it is integrated with other systems such as photovoltaic panels or building envelopes. The complexity further increases when the substrate also participates in the radiative cooling (along with the radiative coating). Energy estimation is becoming increasingly critical because of the recent focus on the semitransparent radiative coatings that transmit a variety of colors to enhance the aesthetic appeal of the system. In this work, we propose an iterative method to calculate the effective radiative properties, which provides the same net radiative cooling that would be observed using the spectral properties at both the coating and substrate surfaces. Compared to traditional methods that rely on either computationally expensive full spectral analysis or methods for averaging each radiative surface parameter locally, our proposed method focuses on calculating effective properties that provide the same the net cooling effect as a full spectral analysis by accounting the emissivity, absorptivity, and transmissivity collectively, thereby providing an overall estimation error of less than 0.2%. We believe that this study will be beneficial to the engineering communities that employ complex simulation codes and require lumped solar and thermal radiation related parameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The radiative effects of clouds and their impact on climate

The radiative effects of clouds on the climate system are reviewed on the basis of data published over the last 15-20 years and some relevant unpublished model studies. Emphasis is placed on the impact of clouds on the incoming and outgoing radiation at the top of the atmosphere and the two-way interaction of clouds with other variables of the climate system, i.e., the cloud/climate feedback problem, as revealed by climate model simulations. Investigations aimed at determining the overall effects of clouds on the climate system (climate forcing) show that clouds have a net cooling effect. Two estimates of the global annual average effect of clouds on the net flux at the top of the atmosphere, based on recent satellite observations, show wide discrepancies. The sign of cloud feedback is found to be positive when the spatial distribution of clouds is allowed to vary in response to climate change. It is concluded that clouds may have a strong influence on climate change, but the magnitude of this influence is unknown.

Arking, Albert↗

RP-2 Thermal Stability and Heat Transfer Investigation for Hydrocarbon Boost Engines

A series of electrically heated tube tests were performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the use of RP-2 as a fuel for next generation regeneratively cooled hydrocarbon boost engines. The effect that test duration, operating condition and test piece material have on the overall thermal stability and materials compatibility characteristics of RP-2 were evaluated using copper and 304 stainless steel test sections. The copper tests were run at 1000 psia, heat flux up to 6.0 Btu/in.2-sec, and wall temperatures up to 1180 F. Preliminary results, using measured wall temperature as an indirect indicator of the carbon deposition process, show that in copper test pieces above approximately 850 F, RP-2 begins to undergo thermal decomposition resulting in local carbon deposits. Wall temperature traces show significant local temperature increases followed by near instantaneous drops which have been attributed to the carbon deposition/shedding process in previous investigations. Data reduction is currently underway for the stainless steel test sections and carbon deposition measurements will be performed in the future for all test sections used in this investigation. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-2.

VanNoord, J. L.↗

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

Environmental Co‐Benefits of Maintaining Native Vegetation With Solar Photovoltaic Infrastructure

Abstract Co‐locating solar photovoltaics with vegetation could provide a sustainable solution to meeting growing food and energy demands. However, studies quantifying multiple co‐benefits resulting from maintaining vegetation at utility‐scale solar power plants are limited. We monitored the microclimate, soil moisture, panel temperature, electricity generation and soil properties at a utility‐scale solar facility in a continental climate with different site management practices. The compounding effect of photovoltaic arrays and vegetation may homogenize soil moisture distribution and provide greater soil temperature buffer against extreme temperatures. The vegetated solar areas had significantly higher soil moisture, carbon, and other nutrients compared to bare solar areas. Agrivoltaics in agricultural areas with carbon debt can be an effective climate mitigation strategy along with revitalizing agricultural soils, generating income streams from fallow land, and providing pollinator habitats. However, the benefits of vegetation cooling effects on electricity generation are rather site‐specific and depend on the background climate and soil properties. Overall, our findings provide foundational data for site preservation along with targeting site‐specific co‐benefits, and for developing climate resilient and resource conserving agrivoltaic systems.

14 SOLAR ENERGY↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light Absorption in the Stratosphere: Trend, Soot Aerosol Concentration and Contribution by...

The light absorption coefficient, Beta(a) of the stratospheric aerosol is an important quantity that determines its radiative effects. When combined with the aerosol scattering coefficient, Beta(a) it becomes possible to evaluate the aerosol single scatter albedo, omega = Beta(s)/(Beta(s) + Beta(a)) which is essential for modeling the overall radiative effects of the stratospheric aerosol. Pollack1 determined that omega = 0.98 is a critical value that separates stratospheric cooling from warming.

Pueschel, R. F.↗