Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

System and method for preventing stator permanent magnet demagnetization during vacuum pressure impregnation

A permanent magnet electrical machine includes a stator having conductive windings wound thereon and one or more permanent magnets embedded in the stator. A magnetic keeper element is positioned on the stator so as to form a magnetic flux path with the permanent magnets, with the magnetic keeper element closing the magnetic flux path of the permanent magnets by providing a low reluctance flux path to magnetic flux generated by the permanent magnets. A vacuum pressure impregnation (VPI) process is performed on the stator to increase a thermal conductivity of the windings, with the VPI process including a curing step that is performed at a selected temperature. The magnetic keeper element sets an operating point of the permanent magnets to an internal flux density level above a demagnetization threshold associated with the selected temperature at which the curing step is performed.

42 ENGINEERING↗

MnBi 2 Is a Permanent Magnet

Creating and understanding new permanent magnets requires an understanding of the impact of orbital angular momentum on coercivity. A simple approach to interrogating this relationship is by incorporating high Z (where Z is the atomic number) elements into binary compounds to maximize spin–orbit coupling. The Mn–Bi system is an appealing platform for these studies since it contains MnBi, a permanent magnet with a large coercive field. We previously identified a new compound in the Mn–Bi system, MnBi 2 , but could not elucidate its magnetic properties ex situ due to its decomposition upon decompression. Here, we harnessed synchrotron X-ray magnetic circular dichroism to probe the magnetism of MnBi 2 at high pressure within a diamond anvil cell. Our results indicate that MnBi 2 exhibits ferromagnetic hysteresis at both 10 K and room temperature. Through calculations and experiments, we show that orbital angular momentum and spin–orbit coupling from Bi impart magnetic anisotropy in MnBi 2 . Comparing the Mn–Bi family of compounds, we consider the Bi p and d orbitals to explain the differences in magnetic behavior within the system. Collectively, these results validate leveraging high-Z elements in the synthesis of new hard permanent magnets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of atom substitutions on the magnetic properties in Ce 2 Fe 17 : Toward permanent magnet applications

Due to the rapidly developing technologies and huge market demand, there has been increasing interest internationally in exploring permanent magnet formulations in addition to the well-known Nd 2 Fe 14 B and SmCo 5 /Sm 2 Co 17 . Given Fe's low materials cost and generally high magnetization, Fe-rich rare earth binaries such as Ce 2 Fe 17 comprise a rich “hunting ground” for such new materials. While this compound suffers from a low ordering point and is a heli magnet, these difficulties are easily remedied by the substitution of appropriate amounts of cobalt for Fe, with room-temperature saturation magnetization as high as 1.5 T. In this work, we try to switch the all-important magnetic anisotropy from planar to uniaxial behavior in Ce 2 Fe 17 via 18 h - and 6 c -type atom substitutions with Si, Ir, and numerous other atoms. The uniaxial magnetocrystalline anisotropy is successfully achieved in the 6 c -site-substituted Ce 2 Fe 15 Ir 2 systems, along with large magnetization. We find that iridium substitution, in particular, induces a substantial uniaxial anisotropy of 11.25 MJ/m 3 , which is comparable to most of the current rare earth permanent magnets. Although the iridium substitution is costly, the finding of Ir-triggered uniaxial magnetic anisotropy indicates the potential of Ce–Fe-based alloys for permanent magnets.

36 MATERIALS SCIENCE↗

Permanent-Magnet Meissner Bearing

Permanent-magnet meissner bearing features inherently stable, self-centering conical configuration. Bearing made stiffer or less stiff by selection of magnets, springs, and spring adjustments. Cylindrical permanent magnets with axial magnetization stacked coaxially on rotor with alternating polarity. Typically, rare-earth magnets used. Magnets machined and fitted together to form conical outer surface.

Robertson, Glen A.↗

Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source

Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar{sup 4+} ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Periodic permanent magnet focused klystron

A periodic permanent magnet (PPM) klystron has beam transport structures and RF cavity structures, each of which has permanent magnets placed substantially equidistant from a beam tunnel formed about the central axis, and which are also outside the extent of a cooling chamber. The RF cavity sections also have permanent magnets which are placed substantially equidistant from the beam tunnel, but which include an RF cavity coupling to the beam tunnel for enhancement of RF carried by an electron beam in the beam tunnel.

43 PARTICLE ACCELERATORS↗

Design and instrumentation for permanent magnet samples exposed to a radiation environment

This work is part of a larger program to study the effects of radiation on permanent magnets in an accelerator environment. In order to be sure that the permanent magnet samples are accurately placed, measured, and catalogued we have developed a system of sample racks, holders and measuring apparatuses. We have combined these holders and measurement racks with electronics to allow a single computer to catalogue the position and intensity of the magnet measurements. We outline the design of the apparatus, the collection software, and the methodology we will use to collect the data.

Accelerator Physics↗

Selecting the Rotor’s Magnetic System in Electromechanical Energy Converters with Highly Coercive Permanent Magnets

The selection of the optimal magnetic system for a quadrupole electromechanical energy converter with highly coercive permanent magnets is considered, in the case of nonsteady operation in generator mode. The type of magnetic system corresponding to different optimality criteria is identified. The eddy-current losses in the highly coercive permanent magnets are analyzed.

42 ENGINEERING↗

Magnetized sheath near positively biased wall between two permanent magnetic plates

The characteristics of magnetized electron sheath near a positively biased conducting wall parallel to magnetic field formed between two permanent magnetic plates were experimentally investigated in a double plasma device. The magnetic field strength between the magnetic plates is about 1200 G which is sufficient to magnetize the plasma such that the ion gyroradius is comparable to the electron Debye length. A virtual cathode (or potential dip) structure was found between the electron-rich sheath and bulk plasma. For a given neutral gas pressure, the potential minimum (dip position) remains almost the same for different positive biases on the wall. For a given bias on the wall, however, the electron sheath thickness and the potential drop from the bulk plasma to the dip decrease with the increase of the neutral gas pressure. In addition, the electron sheath and potential dip appear to be wider and deeper in the downstream side of the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

Comparison of Achievable Magnetic Fields with Superconducting and Cryogenic Permanent Magnet Undulators – A Comprehensive Study of Computed and Measured Values

Magnetic modeling was performed to estimate achievable magnetic field strengths of superconducting undulators (SCUs) and to compare them with those of cryogenically cooled permanent magnet undulators (CPMUs). Starting with vacuum (beam stay-clear) gaps of 4.0 and 6.0 mm, realistic allowances for beam chambers (in the SCU case) and beam liners (in the CPMU case) were added. (A 6.0-mm vacuum gap is planned for the upgraded APS). The CPMU magnetic models consider both CPMUs that use NdFeB magnets at ~150 K and PrFeB magnets at 77 K. Parameters of the magnetic models are presented along with fitted coefficients of a Halbach-type expression for the field dependence on the gap-to-period ratio. Field strengths for SCUs are estimated using a scaling law for planar SCUs; an equation for that is given. The SCUs provide higher magnetic fields than the highest-field CPMUs – those using PrFeB at 77 K – for period lengths longer than ~14 mm for NbTi-based SCUs and ~10 mm for Nb3Sn-based SCUs. To show that the model calculations and scaling law results are realistic, they are compared to CPMUs that have been built and NbTi-based SCUs that have been built. Brightness tuning curves of CPMUs (PrFeB) and SCUs (NbTi) for the upgraded APS lattice are also provided for realistic period lengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Remote Distributed Vibration Sensing Through Opaque Media Using Permanent Magnets

Vibration sensing is critical for a variety of applications from structural fatigue monitoring to understanding the modes of airplane wings. In particular, remote sensing techniques are needed for measuring the vibrations of multiple points simultaneously, assessing vibrations inside opaque metal vessels, and sensing through smoke clouds and other optically challenging environments. Here, in this paper, we propose a method which measures high-frequency displacements remotely using changes in the magnetic field generated by permanent magnets. We leverage the unique nature of vibration tracking and use a calibrated local model technique developed specifically to improve the frequency-domain estimation accuracy. The results show that two-dimensional local models surpass the dipole model in tracking high-frequency motions. A theoretical basis for understanding the effects of electronic noise and error due to correlated variables is generated in order to predict the performance of experiments prior to implementation. Simultaneous measurements of up to three independent vibrating components are shown. The relative accuracy of the magnet-based displacement tracking with respect to the video tracking ranges from 40 to 190 μm when the maximum displacements approach ±5 mm and when sensor-to-magnet distances vary from 25 to 36 mm. Finally, vibration sensing inside an opaque metal vessel and mode shape changes due to damage on an aluminum beam are also studied using the wireless permanent-magnet vibration sensing scheme.

42 ENGINEERING↗

Permanent magnets for ELM suppression in tokamaks: feasibility and operational compatibility

Permanent magnets can provide static magnetic fields without power supplies or feed lines, offering a simpler alternative to conventional electromagnets in tokamaks. This work examines permanent magnet arrays (PMAs) for edge localized mode (ELM) control in double-null (DN) configurations, where traditional RMP coils exhibit limited effectiveness. Linear plasma response calculations using IPEC assess high-field-side (HFS) permanent magnet placement, benchmarking performance against DIII-D low-field-side (LFS) internal coils (I-coils) while evaluating engineering constraints. Modeling results demonstrate that HFS permanent magnet configurations generate HFS plasma response amplitudes more than 5 times larger than conventional I-coil systems. While other resonant response metrics show comparable or reduced response relative to I-coils, the combination of conventional RMP systems and permanent magnets is expected to provide enhanced performance. Operational impact assessments of persistent magnetic fields, including sideband field effects and startup/ramp-up compatibility, reveal acceptable performance within established operational boundaries. This analysis establishes PMAs as a technically viable approach for DN ELM control with reductions in system complexity, motivating further experimental validation on existing tokamak facilities.

3D magnetic perturbation↗

Studies on the effect of the axial magnetic field on the x-ray bremsstrahlung in a 2.45 GHz permanent magnet microwave ion source

A compact microwave ion source has been designed and developed for operation at a frequency of 2.45 GHz. The axial magnetic field is based on two permanent magnet rings, operating in the “off-resonance” mode and is tunable by moving the permanent magnets. In order to understand the electron energy distribution function, x-ray bremsstrahlung has been measured in the axial direction. Simulation studies on the x-ray bremsstrahlung have been carried out to compare with the experimental results. The effect of the axial magnetic field with respect to the microwave launching position and the position of the extraction electrode on the x-ray bremsstrahlung have been studied.

43 PARTICLE ACCELERATORS↗