Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Arterial Phase CTA Replacement by a Virtual Arterial Phase Reconstruction from a Venous Phase CTA: Preliminary Results Using Detector-Based Spectral CT

Objective: To assess the feasibility of creating virtual monoenergetic arterial images from venous phase CTA obtained on a detector-based spectral CT scanner and quantitatively compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios of the major arteries to those on polyenergetic true arterial phase images. Methods: In this retrospective study, 23 patients (15 men and 8 women, median age 68 years) who underwent triple-phase CTA on a spectral CT scanner for aortic endograft surveillance were included. The venous phase CTA of each study was reconstructed to generate virtual monoenergetic images at various keV, which were compared to true arterial phase CTA images. SNR and CNR of the aortoiliac arteries were evaluated by testing the differences in means and non-inferiority of virtual arterial images to true arterial images. Effective radiation dose was calculated for standard triple-phase studies in comparison with dual-phase and single-phase spectral CT examinations. Results: Virtual monoenergetic images demonstrated non-inferior (P < 0.05) arterial SNR and CNR compared to true arterial images at 40 keV for all arteries, at 45–50 keV for the thoracic and suprarenal aorta, and at 45–55 keV for the infrarenal aorta and iliac arteries. Significantly higher (P < 0.05) arterial attenuation was obtained at 40 keV for the aortoiliac arteries. Mean effective dose for conventional triple-phase studies was 32.5 mSv in comparison with 21.3 mSv for dual-phase non-contrast/venous scans and 11.3 mSv for single-phase venous scans. Conclusions: Detector-based spectral CT enables creation of virtual monoenergetic arterial images from venous phase CTA with equivalent and in some cases significantly higher SNR/CNR of major arteries compared to images from true arterial phase polyenergetic CTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. Finally, the characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning-Based Technique for Automated Sensor Characterization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert s time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Zepeda, Cuevas [Chicago U., KICP]↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗

Energy calibration of the ProtoDUNE-SP TPC

The single-phase liquid argon prototype at CERN (ProtoDUNE-SP) acts as a validation of the design for the DUNE single-phase far detector. With a total mass of 770 tons, it is the largest monolithic liquid argon single-phase time projection chamber in the world. ProtoDUNE-SP collected test-beam in autumn of 2018 and has been collecting cosmic and special calibration data since the end of 2018. To analyze data from the test-beam, a calibration plan using cosmic muons passing through the detector was developed. An outline of this plan and its impact on the calorimetric measurements of the detector will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

We report that large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay (0νββ) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas- or liquid-phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time-projection chambers to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for 0νββ at half-life sensitivities as long as 10 30 yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of space charge effects and energy calibration in ProtoDUNE-SP

The single-phase liquid argon prototype at CERN (ProtoDUNE-SP) acts as a validation of the design for the DUNE single-phase far detector. With a total mass of 770 tons, it is the largest monolithic liquid argon single-phase time projection chamber in the world. ProtoDUNE-SP collected test-beam in autumn of 2018 and has been collecting cosmic and special calibration data since the end of 2018.The accumulation of positive ions in a LArTPC located on the surface can distort the electric field and the reconstructed particle trajectories. It is critical to understand and correct for the space charge effects in order to achieve the desired spatial and calorimetric resolutions in the LArTPC. This talk will present the measurement of space charge effects and the calorimetric measurements of the detector in ProtoDUNE-SP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The construction of the phase-1 upgrade of the CMS pixel detector

The innermost layers of the original CMS tracker were built out of pixel detectors arranged in three barrel layers and two forward disks in each endcap. The original CMS detector was designed for the nominal instantaneous LHC luminosity of 1×10 34 cm -2 s -1 . Under the conditions expected in the coming years, which will see an increase of a factor two of the instantaneous luminosity, the CMS pixel detector would have seen a dynamic inefficiency caused by data losses due to buffer overflows. For this reason the CMS collaboration has installed a replacement pixel detector during the recent extended end of year shutdown. The phase-1 upgrade of the CMS pixel detector will operate at high efficiency at an instantaneous luminosity of 2×10 34 cm -2 s -1 with increased detector acceptance and additional redundancy for the tracking, while at the same time reducing the material budget. These goals are achieved using a new read-out chip and modified powering and read-out schemes, one additional tracking layer both in the barrel and in the disks, and new detector supports including a CO 2 based evaporative cooling system, that contribute to the reduction of the material in the tracking volume. This contribution will review the design and technological choices of the phase-1 detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ATLAS Inner Tracker Strip Detector System for the Phase-II Large Hadron Collider Upgrade

ATLAS is currently preparing for the HL-LHC upgrade, with an all-silicon Inner Tracker (ITk) that will replace the current Inner Detector. The ITk will feature a pixel detector surrounded by a strip detector, with the strip system consisting of four barrel layers and 12 endcap disks. After successful completion of a large-scale prototyping program, final design reviews have been completed in key areas, such as sensors, modules, front-end electronics, and ASICs. We present an overview of the strip system and highlight the final design choices of sensors, modules, and ASICs. We summarize the results achieved during prototyping and the current status of production and pre-production on various detector components, with an emphasis on QA and QC procedures.

Duden, Emily (ORCID:0000000290929344)↗

The ATLAS ITk Strip detector system for the Phase-II LHC upgrade

In the view of the luminosity increase foreseen by the High-Luminosity Large Hadron Collider program at CERN, the ATLAS experiment initiated an R&D program to replace its complete inner detector (ID) system. The new Inner Tracker (ITk) system, anticipated to be installed by 2028, will be a new all-silicon based tracker including Strip and Pixel detector technologies. The new detector is designed to meet the requirements of operating under a harsh environment namely, high radiation levels, increased pile-up and data rates while decrease the material budget and maintain or even improve the performance. The Strip project has advanced in several areas the last years while facing challenges moving from pre-production to production. Here, this manuscript gives an overview of the ITk Strip system and describes the advancements and challenges to date.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark matter detection capabilities of a large multipurpose Liquid Argon Time Projection Chamber

Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground Neutrino Experiment (DUNE) . Here in this paper we take as a starting point the dual phase far detector design proposed by the DUNE experiment and ask what changes are necessary to allow one of the four 10 kt modules to be sensitive to heavy Weakly Interacting Massive Particle (WIMP) dark matter. We show that with control over backgrounds and the use of low radioactivity argon, which may be commercially available on that timescale, along with a significant increase in light detection, one DUNE-like module gives a competitive WIMP detection sensitivity, particularly above a dark matter mass of 100 GeV.

47 OTHER INSTRUMENTATION↗

Slicing with deep learning models at ProtoDUNE-SP

DUNE is a cutting-edge experiment aiming to study neutrinos in detail, with a special focus on the flavor oscillation mechanism. The prototype of the DUNE Far Detector Single Phase TPC (ProtoDUNE-SP) was built and operated at CERN with a full set of reconstruction tools. To implement these reconstruction tools, Pandora, a multi-algorithm framework, has been developed. A large number of these algorithms, some of them being exploiting traditional clustering, detector physics and deep learning approaches, have been applied to images to gradually build up a picture out of singular events. One of such algorithms is the Pandora slicing algorithm which aims to partition the detector hits of an event in sets called slices. Each slice represents a single interaction in the detector and should identify all the hits related to the interacting particle and its subsequent decay products. We expect the order of tens of slices per event in ProtoDUNE-SP. In this paper we present a deep learning approach to the problem, designing a model able to outperform the state-of-the-art slicing algorithm which is currently implemented within Pandora. We assess the performance of our tool in terms of efficiency and accuracy, while exploiting hardware accelerating setups. The ultimate goal is to incorporate this deep learning approach in the Pandora reconstruction tool.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Module Testing Procedures and Results for the CMS Phase-2 Outer Tracker Upgrade at Fermilab

The High-Luminosity LHC (HL-LHC) will operate at significantly increased luminosities and is expected to deliver about 3000 $fb^{-1}$ of proton-proton collision data at $\sqrt{s}=14$ TeV over a decade of operation. To maintain efficient tracking and triggering performance under high pileup and radiation conditions, the CMS experiment is upgrading its tracking detector for Phase-2 operations. The upgraded Outer Tracker (OT) will consist of Pixel-Strip (PS) and Strip-Strip (2S) silicon modules capable of providing tracking information to the Level-1 trigger at 40 MHz. Production and qualification of OT modules have been ongoing for about one year across several assembly and testing centers in the US, Europe, India, and Pakistan, requiring extensive testing to ensure stable operation in the HL-LHC environment. Fermilab is responsible for the production and testing of a significant fraction of the OT modules. The testing activities include IV characterization of silicon sensors, noise and pedestal measurements, verification of communication between module components, and burn-in studies using cold-box systems operated under controlled thermal conditions. Results from module testing and qualification studies performed during production will be presented.

Baradia, Sweta [UC, Davis (main)]↗

Detector R&D for ANNIE and Future Neutrino Experiments

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is designed to serve as a test bed for new detector technologies in future water and liquid scintillator based neutrino experiments. Located on the Booster Neutrino Beam at Fermilab, ANNIE will be the first gadolinium-loaded water Cherenkov detector on a neutrino beam and will provide high statistics measurements of neutron yields from neutrino interactions in water. It is also the first particle physics application of the new photosensor technology: Large Area Picosecond Photodetectors (LAPPDs). With single photon time resolutions of roughly 50 psec and mm-level imaging capabilities, LAPPDs bring considerable new capabilities for neutrino reconstruction in Cherenkov and scintillator detectors. Leveraging this technology to make detailed neutrino measurements, ANNIE will serve as a first demonstration of their impact on physics. In addition to LAPPDs, the ANNIE R&D program will likely explore other new technologies such as the addition of water-based liquid scintillator. The ANNIE Phase II detector is currently under construction and will start to take data in the summer of 2019. In this talk, I will present on the ANNIE detector R&D program and its relevance to current and future neutrino experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS

A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC)has been designed to read out and correlate hits from pairs of tracker sensors, forming so called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase 2 Outer Tracker Analyzer of Test Outputs - POTATO!

The Phase-2 upgrade of the Large Hadron Collider (LHC), also known as the High-Luminosity LHC (HL-LHC) is designed to achieve peak instantaneous luminosities which is about an order of magnitude higher than the nominal design value of $10^{34}~cm^{-2}s^{-1}$ delivering a total of atleast $3000 fb^{-1}$ data over 10 years of operation at $\sqrt{s}~=~14~TeV$. One crucial aspect of the CMS Phase-2 detector upgrade is the replacement of the existing tracking detector in order to deal with the extreme HL-LHC conditions, retaining and further expanding the physics performances achieved in the previous years. The outer part of the upgraded tracker (OT), will be equipped with over 13,000 macro Pixel-Strip (PS) and Strip-Strip (2S) modules! Module production is distributed across centers worldwide and necessitates coordinated efforts and standardized procedures. Along with production and assembly of the modules, Fermilab OT group is also working on a tool, Phase 2 Outer Tracker Analyzer of Test Outputs (POTATO) that will analyze, grade, upload and manage the large quantity of files to be stored in the centralized Database (DB). In this contribution a brief overview of the module testing and the power and dire need of POTATO to handle this large number of test outputs will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CMS Phase 2 Outer Tracker Analyzer of Test Outputs - POTATO!

The Phase-2 upgrade of the Large Hadron Collider (LHC), also known as the High-Luminosity LHC (HL-LHC) is designed to achieve peak instantaneous luminosities which is about an order of magnitude higher than the nominal design value of $10^{34}~cm^{-2}s^{-1}$ delivering a total of atleast $3000 fb^{-1}$ data over 10 years of operation at $\sqrt{s}~=~14~TeV$. One crucial aspect of the CMS Phase-2 detector upgrade is the replacement of the existing tracking detector in order to deal with the extreme HL-LHC conditions, retaining and further expanding the physics performances achieved in the previous years. The outer part of the upgraded tracker (OT), will be equipped with over 13,000 macro Pixel-Strip (PS) and Strip-Strip (2S) modules! Module production is distributed across centers worldwide and necessitates coordinated efforts and standardized procedures. Along with production and assembly of the modules, Fermilab OT group is also working on a tool, Phase 2 Outer Tracker Analyzer of Test Outputs (POTATO) that will analyze, grade, upload and manage the large quantity of files to be stored in the centralized Database (DB). In this contribution a brief overview of the module testing and the power and dire need of POTATO to handle this large number of test outputs will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗