Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASOR MEASUREMENT UNIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Measurement Source Authentication Methodology for Power System Cyber Security Enhancement

This letter proposes a spatial signature-based power system measurement source identification and authentication methodology. A mathematical morphology method is used to decompose the power system measurement signals and obtain the intrinsic components, which sparsity trends and roughness values are further derived to establish the time-frequency (TF) sparsity mapping. Then random forest classification is utilized to correlate the correct measurement source for each measurement signal based on the derived TF sparsity mapping. Finally, experiment results using five phasor measurement units has validated the effectiveness of this methodology.

42 ENGINEERING↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

FOA 1861 Data Curation Overview

This document describes the process executed to collect, examine, and consolidate Phasor Measurement Unit (PMU) data from multiple transmission operators into a common dataset. The consolidated PMU data set was further anonymized and distributed to the Department of Energy Funding Opportunity Announcement (FOA) 1861 Big Data Analysis of Synchrophasor Data awardees.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adversarial Attacks on Deep Neural Network-based Power System Event Classification Models

Online event classification is essential to strengthening the reliability of the power transmission system. Recently, deep learning based methods have achieved great success in numerous domains such as computer vision and natural language processing. Researchers began to adopt deep learning based methods to solve the power system event identification problem and achieved effective results. However, these previous works do not consider that deep learning models are vulnerable to adversarial attacks, potentially influencing real-world applications' reliability. In this paper, we adopt several adversarial attack mechanisms by adding tailored noise signal to the input Phasor Measurement Units (PMU) time series and make the deep learning model misclassify the power system event. This numerical study discloses that current state-of-the-art deep learning based power system event classifiers are extremely vulnerable to adversarial attacks, which may jeopardize the reliability of the power transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronized Phasor Data for Analyzing Wind Power Plant Dynamic Behavior and Model Validation

The U.S. power industry is undertaking several initiatives that will improve the operations of the power grid. One of those is the implementation of 'wide area measurements' using phasor measurement units (PMUs) to dynamically monitor the operations and the status of the network and provide advanced situational awareness and stability assessment. This project seeks to obtain PMU data from wind power plants and grid reference points and develop software tools to analyze and visualize synchrophasor data for the purpose of better understanding wind power plant dynamic behaviors under normal and contingency conditions.

17 WIND ENERGY↗

Synchrophasor Applications for Wind Power Generation

The U.S. power industry is undertaking several initiatives that will improve the operations of the electric power grid. One of those is the implementation of wide-area measurements using phasor measurement units to dynamically monitor the operations and status of the network and provide advanced situational awareness and stability assessment. The overviews of synchrophasors and stability analyses in this report are intended to present the potential future applications of synchrophasors for power system operations under high penetrations of wind and other renewable energy sources.

17 WIND ENERGY↗

PMU and Communication Infrastructure Restoration for Post-Attack Observability Recovery of Power Grids

This paper is concerned about recovering the observability of cyber-physical power grids after massive cyber attacks, which helps to achieve the cyber-physical resilience of the grids. For recovering the observability of the grid, the measurability of the Phasor Measurement Units (PMUs) and the connectivity of the communication network are needed to be restored. The PMU and communication infrastructure restoration problem is jointly formulated as a Mixed Integer Linear Programming (MILP) problem to minimize the observability loss of the grid over time after a cyber attack while considering the constraint of limited resources. The efficacy of the proposed optimal restoration strategy is verified by comparing with heuristic methods on the IEEE 57-bus system.

cyber security↗

Anomaly Detection Using Optimally-Placed μPMU Sensors in Distribution Grids

IEEE As the distribution grid moves toward a tightly-monitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. Here, focusing on Micro-Phasor Measurement Unit (μPMU) data, we propose a hierarchical architecture for monitoring the grid and establish a set of analytics and sensor fusion primitives for the detection of abnormal behavior in the control perimeter. And due to the key role of the μPMU devices in our architecture, a source-constrained optimal μPMU placement is also described that finds the best location of the devices with respect to our rules. The effectiveness of the proposed methods are tested through the synthetic and real μPMU data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applications of synchrophasor technologies in power systems

Synchrophasors are time-synchronized electrical measurements that represent both the magnitude and phase angle of the electrical sinusoids. Synchrophasors are measured by fast time-stamped devices called phasor measurement units (PMUs) to constitute the basis of real-time monitoring and control actions in the electric grid. Due to its enhanced situational awareness capabilities, many applications of PMUs are presented in the literature in the past decades. This paper presents a comprehensive summary of synchrophasor technology, its architecture, optimal placement techniques and its applications in electric power transmission and distribution systems. These applications include wide-area situational awareness and monitoring, state estimation, fault location and protective relaying, islanding detection etc. This review also covers some of the existing challenges in its implementation and its potential applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Computational Viability of Quantum Optimization for PMU Placement

Using optimal phasor measurement unit placement as a prototypical problem, we assess the computational viability of the current generation D-Wave Systems 2000Q quantum annealer for power systems design problems. We reformulate minimum dominating set for the annealer hardware, solve the reformulation for a standard set of IEEE test systems, and benchmark solution quality and time to solution against the CPLEX optimizer and simulated annealing. For some problem instances the 2000Q outpaces CPLEX. For instances where the 2000Q underperforms with respect to CPLEX and simulated annealing, we suggest hardware improvements for the next generation of quantum annealers.

hardware↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

A Coherence Method for Detecting and Analyzing Oscillations

In this paper, a coherence method is proposed to detect and analyze forced oscillations from phasor measurement unit data. The calculation of coherence spectrum is reviewed, and forced oscillations are related to the peaks in the coherence spectrum. Using simulation and field measurement data, the proposed coherence method’s performance is compared with the power spectral density method. When applied to detect and analyze forced oscillations under low signal noise ratio conditions, the proposed coherence method shows better performance.

coherence↗

Optimal PMU Restoration for Power System Observability Recovery After Massive Attacks

Cyber-physically resilient power system operation requires rapid recovery of situational awareness after disastrous scenarios such as massive cyber attacks. In this article, the concept of optimal sequential restoration of Phasor Measurement Units is introduced, aiming at rapid recovery of power system observability in post-attack scenarios. Additionally, the observability recovery problem is formulated as a Mixed Integer Linear Programming problem to maximize the cumulative observability level gained over time during the restoration process. Three alternative objective functions-maximizing the number of observable buses, the number of observable branches, and the total amount of observable power flow-are considered. The effectiveness of the proposed optimal strategy is verified by comparing it with heuristic approaches on the IEEE 57-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PMU Data Event Detection: A User Guide for Power Engineers

This user guide is intended to accompany a software package containing a Matrix Laboratory (MATLAB) script and related functions for processing phasor measurement unit (PMU) data. This package and guide have been developed by the National Renewable Energy Laboratory and the University of Texas at Austin. The objective of this data processing exercise is to discover events in the vast quantities of data collected by PMUs. This document attempts to cover some of the theory behind processing the data to isolate events as well as the functioning of the MATLAB scripts. The report describes (1) the algorithms and mathematical background that the accompanying MATLAB codes use to detect events in PMU data and (2) the inputs required from the user and the outputs generated by the scripts.

17 WIND ENERGY↗

Power System Event Identification Based on Deep Neural Network With Information Loading

Online power system event identification and classification are crucial to enhancing the reliability of transmission systems. In this study, we develop a deep neural network (DNN) based approach to identify and classify power system events by leveraging real-world measurements from hundreds of phasor measurement units (PMUs) and labels from thousands of events. Two innovative designs are embedded into the baseline model built on convolutional neural networks (CNNs) to improve the event classification accuracy. First, we propose a graph signal processing based PMU sorting algorithm to improve the learning efficiency of CNNs. Second, we deploy information loading based regularization to strike the right balance between memorization and generalization for the DNN. Numerical results based on real-world dataset from the Eastern Interconnection of the U.S power transmission grid show that the combination of PMU based sorting and the information loading based regularization techniques help the proposed DNN approach achieve highly accurate event identification and classification results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pioneer Design of Non-contact Synchronized Measurement Devices Using Electric and Magnetic Field Sensors

Here, traditional synchrophasors rely on CTs and PTs physically connected to transmission lines or buses to acquire input signals for phasor measurement. However, it is challenging to install and maintain traditional phasor measurement units in some remote areas due to lack of facilities. Since transmission lines naturally generate alternating electrical and magnetic fields in the surrounding atmosphere, this paper presents two innovative designs for non-contact synchronized measurement devices (NCSMD), including an electric field sensor based non-contact SMD (E-NCSMD) and a magnetic field sensor based non-contact SMD (M-NCSMD). Compared with conventional synchrophasors, E-NCSMD and M-NCSMD are much more flexible to be deployed and have much lower costs, making E-NCSMDs and M-NCSMD highly accessible and useful for a wide array of phasor measurement applications. Laboratory and field experiment results verified the effectiveness of the designs of both E-NCSMD and M-NCSMD.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discovery of Signatures, Anomalies, and Precursors in Synchrophasor Data with Matrix Profile and Deep Recurrent Neural Networks (Final Project Report)

The widespread deployment of phasor measurement unit (PMU) across the U.S. together with the burgeoning machine learning technology made it possible to develop data-driven PMU data analytics to improve grid security and reliability in a more insightful and effective manner. Although PMU applications have been explored for over a decade, the representative PMU usage is limited to the bulk power system monitoring mainly due to the data integrity issues associated with PMUs (typically missing, fragmented, and wrongly amplified data). To forge a breakthrough on this stalemate and embrace PMUs for power system control and protection as well, we applied various advanced machine learning and big data analysis technology to the power system event detection and classification as the first step toward the power system control and protection pertaining to grid security enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗