Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOELECTRON COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Synthesis and crystal chemistry of microporous titanates K{sub x}(Ti,M){sub 8}O{sub 16} where M=Sc–Ni

Through salt-flux methods, single crystals of eight novel hollandite-type titanates have been grown with the stoichiometry K{sub x}(Ti{sub 8−y}M{sub y}){sub 8}O{sub 16} for x=y≈1.5 where M{sup 3+}=Sc, Ti, V, Cr, Mn, and Fe, and for x/2=y≈0.75 where M{sup 2+}=Co and Ni. Single crystal and powder X-ray diffraction reveals phase pure crystals with tetragonal space group I4/m. These titanates are microporous oxides with 1-dimensional channels where the non-framework cation, K, resides. In addition to diffraction, spectroscopic methods were used to characterize the chemical composition of both the bulk and surface. X-ray photoelectron spectroscopy affords the oxidation states of the substituted transition metals M on the surface and energy dispersive X-ray spectroscopy the metal ratios, including that of potassium, for an overall accurate description of the chemical composition of both the bulk and surface. Magnetization versus temperature measurements indicate that all phases are Curie paramagnets with effective magnetic moments consistent with the d-electron count given by combined X-ray diffraction and elemental analysis techniques. - Highlights: • Single crystal growth of K{sub x}(Ti,M){sub 8}O{sub 16} for M=Sc–Ni via molten salt flux. • Single crystal and powder X-ray diffraction utilized for structure of all compounds. • Oxidation states for all metals determined by X-ray photoelectron spectroscopy. • Cation stoichiometry confirmed by energy dispersive spectroscopy. • Effective moments from magnetization coincide with spectroscopy results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The minimum crystal size needed for a complete diffraction data set

A formula for absolute scattering power is derived to include spot fading arising from radiation damage and the crystal volume needed to collect diffraction data to a given resolution is calculated. In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 Å resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 µm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 µm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low intensity X-ray and gamma-ray spectrometer

A low intensity X-ray and gamma ray spectrometer for imaging, counting, and energy resolving of single invisible radiation particles is described. The spectrometer includes a converting device for converting single invisible radiation particles to visible light photons. Another converting device converts the visible light photons to photoelectrons. A fiber optics coupling device couples together the two converting devices. An intensifying device intensifies the photoelectrons by an average gain factor of between 10 to the 4th power and 10 to the 7th power. The tensifying device is an anti-ion feedback microchannel plate amplifier which is operated substantially below saturation. A displaying device displays the intensified photoelectrons. The displaying device 32 indicates the spatial position, number, and energy of the incoming single invisible radiation particles.

Yin, L. I.↗

Simulation of laser-induced coupled electron-nuclear dynamics and time-resolved harmonic spectra in complex systems

We present a theoretical approach for the simulation of time-resolved harmonic spectra, including the effect of nuclear dynamics, which is applicable to complex systems involving many nuclear degrees of freedom. The method is based on the combination of our semiclassical field-induced surface hopping approach for the treatment of laser-induced nuclear dynamics with the time-dependent density functional theory for electron dynamics. We apply our method to the simulation of ultrafast nonadiabatic dynamics and time-resolved harmonic spectra in small silver clusters (Ag{sub 2} and Ag{sub 8}), which exhibit discrete molecularlike electronic transitions. We demonstrate that the harmonic signal is highly sensitive to the nuclear dynamics and thus can be used as a probe of coupled electron-nuclear dynamics, which is complementary to common pump-probe methods such as time-resolved photoelectron spectroscopy. Our simulations allowed us also to determine the mechanism and the time scale of nonradiative relaxation in the 'magic' Ag{sub 8} cluster and have provided a fundamental insight into ultrafast dynamics of metal nanoclusters in the size regime where 'each atom counts'. The excited-state dynamics of Ag{sub 8} involves an isomerization process from the initial structure with T{sub d} symmetry to the quadratic antiprism structure with D{sub 4d} symmetry which takes place on a time scale of {approx}3600 fs and is clearly identified in a time-resolved harmonic signal. Our theoretical approach is generally applicable for the prediction of time-resolved harmonic spectra in complex systems with many nuclear degrees freedom and should serve to stimulate new ultrafast experiments utilizing harmonic signals as a probe for nonadiabatic processes in molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rare-earth transition-metal indium sulphides RE{sub 3}FeInS{sub 7} (RE=La–Pr), RE{sub 3}CoInS{sub 7} (RE=La, Ce), and La{sub 3}NiInS{sub 7}

Six quaternary rare-earth-containing sulphides RE{sub 3}MInS{sub 7} (M=Fe, Co, Ni) have been prepared by reactions of the elements at 1050–1150 °C. They are the first examples of chalcogenides RE{sub 3}MM'Ch{sub 7} adopting related La{sub 3}CuSiS{sub 7}- or ordered Ce{sub 3}Al{sub 1.67}S{sub 7}-type structures in which the M' component is indium. They crystallize in the noncentrosymmetric hexagonal space group P6{sub 3} with Z=2 and cell parameters in the ranges of a=9.95–10.15 Å and c=6.25–6.29 Å for RE{sub 3}FeInS{sub 7} (RE=La–Pr), RE{sub 3}CoInS{sub 7} (RE=La, Ce), and La{sub 3}NiInS{sub 7}. The crystal structure consists of parallel chains of face-sharing M-centred octahedra and stacks of In-centred tetrahedra, all pointing in the same polar direction, with seven-coordinate La atoms in the intervening spaces. X-ray photoelectron spectra support the valence assignments implied by the formulation (RE{sup 3+}){sub 3}(M{sup 2+})(In{sup 3+})(S{sup 2−}){sub 7}. Magnetic measurements are suggestive of antiferromagnetic coupling between the M moments. Band structure calculations reveal that a band gap of 0.25 eV is present in La{sub 3}FeInS{sub 7}, whereas the increased electron count in La{sub 3}CoInS{sub 7} and La{sub 3}NiInS{sub 7} causes the Fermi level to cut narrow bands. - Graphical abstract: RE{sub 3}MInS{sub 7} (M=Fe, Co, Ni) consists of chains of face-sharing M-centred octahedra and stacks of In-centred tetrahedra. - Highlights: • Six members of noncentrosymmetric sulphide series RE{sub 3}MInS{sub 7} have been prepared. • They are the first examples of chalcogenides RE{sub 3}MM'Ch{sub 7} with In atoms in M' site. • X-ray photoelectron spectra support the formulation (RE{sup 3+}){sub 3}(M{sup 2+})(In{sup 3+})(S{sup 2−}){sub 7}. • Band structure calculations suggest semiconducting or metallic behaviour.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing dissociative molecular dications by mapping vibrational wave functions

We present high-resolution photoelectron-Auger-electron coincidence spectra of methane (CH{sub 4}). Since the vibrational structure in the photoelectron spectrum is resolved, the Auger spectra corresponding to different vibrational levels can be separated. The seven final states of CH{sub 4}{sup 2+} are either dissociative or metastable, but in any case are populated in a repulsive part of their potential-energy curve via the Auger decay. The Auger line shapes can therefore be obtained by mapping the vibrational wave functions of the core-hole state into energy space. We have implemented this connection in the data analysis. By simultaneously fitting the different Auger spectra, detailed information on the energies of the dicationic states and their repulsive potential-energy curves is derived.

74 ATOMIC AND MOLECULAR PHYSICS↗

A photoelectron velocity map imaging spectrometer for experiments combining synchrotron and laser radiations

A velocity map imaging/ion time-of-flight spectrometer designed specifically for pump-probe experiments combining synchrotron and laser radiations is described. The in-house built delay line detector can be used in two modes: the high spatial resolution mode and the coincidence mode. In the high spatial resolution mode a kinetic energy resolution of 6% has been achieved. The coincidence mode can be used to improve signal-to-noise ratio for the pump-probe experiments either by using a gate to count electrons only when the laser is present or by recording coincidences with the ion formed in the ionization process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation and characterization of the smallest borospherene, B{sub 28}{sup −} and B{sub 28}

Free-standing boron nanocages or borospherenes have been observed recently for B{sub 40}{sup −} and B{sub 40}. There is evidence that a family of borospherenes may exist. However, the smallest borospherene is still not known. Here, we report experimental and computational evidence of a seashell-like borospherene cage for B{sub 28}{sup −} and B{sub 28}. Photoelectron spectrum of B{sub 28}{sup −} indicated contributions from different isomers. Theoretical calculations showed that the seashell-like B{sub 28}{sup −} borospherene is competing for the global minimum with a planar isomer and it is shown to be present in the cluster beam, contributing to the observed photoelectron spectrum. The seashell structure is found to be the global minimum for neutral B{sub 28} and the B{sub 28}{sup −} cage represents the smallest borospherene observed to date. It is composed of two triangular close-packed B{sub 15} sheets, interconnected via the three corners by sharing two boron atoms. The B{sub 28} borospherene was found to obey the 2(n + 1){sup 2} electron-counting rule for spherical aromaticity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon-counting image sensors for the ultraviolet

An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

Jenkins, E. B.↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗

Soft X-ray photoemission with the SSX-100 spectrometer

Photoemission and SEXAFS experiments were conducted using a double crystal monochromator at the Stanford Synchrotron Radiation Laboratory. Photoelectrons were detected using a Surface Science Laboratories SSX-100 electron analyzer, which employs a magnetic/electrostatic lens, hemispherical geometry, and a two-dimensional position-sensitive detector. In the kinetic energy range of interest (1000-2000 eV), a significant improvement in count rate was observed over a single channel cylindrical mirror analyzer system. Ten second scans of the KLL silicon Auger peak manifold were recorded at a large number of photon energies for subsequent determination of SEXAFS spectra.

Hecht, M. H.↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Characteristics of differential charging of ATS-6

Thirteen days of data collected by the Auroral Particle Experiment onboard the ATS 6 were analyzed emphasizing peculiarities in the electron data attributed to differential charging. On one of these days the satellite was eclipsed by the earth at local midnight. Spectrograms were used to examine the data. It is concluded that differential charging is responsible for returning photoelectrons to the spacecraft up to a couple hundred eV, depending on the spacecraft charge. It is believed that the Minnesota experiment on ATS 6 is largely responsible for producing a potential barrier that returns particles and produces intense spon spots in the count rates.

Johnson, B.↗

Characterizing the radiation response of Cherenkov glass detectors with isotopic sources

Abstract Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gammaray response are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection, Classification and Estimation of Radioactive Contraband from Uncertain Low-Count Measurements

In this final report we discuss the development of the Statistical Radiation Detection System (SRaDS), the next-generation radiation detection software system capable of extracting all available physics information, photon-by-photon, employing Bayesian model-based sequential statistical processing techniques and capable of making a decision when statistically justified. It is a system of computational algorithms consisting of a simple photoelectron processor for the basic system with a combined photoelectron/downscatter processor for the advanced system. Both algorithms have been demonstrated on laboratory data and are available for integration into standard radiation detectors and acquisition systems as well as specialized embedded processing hardware for real-time operations. This report incorporates the basic research performed leading to the development of SRaDS in the form of attached publications discussing the theory, development and validation of the processor and subsequent designs for this powerful solution to the detection problem plaguing the radiation area for a long time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory Characterization and Modeling of a Near-Infrared Enhanced Photomultiplier Tube

The photon-starved channel for optical communications from deep space requires the development of detector technology that can achieve photon-counting sensitivities with high bandwidth. In this article, a near-infrared enhanced photomultiplier tube (PMT) with a quantum e.ciency of 0.08 at a 1.06- m wavelength is characterized in the laboratory. A Polya distribution model is used to compute the probability distribution function of the emitted secondary photoelectrons from the PMT. The model is compared with measured pulse-height distributions with reasonable agreement. The model accounts for realistic device parameters, such as the individual dynode stage gains and a shape parameter that is representative of the spatial uniformity of response across the photocathode and dynodes. Bit-error rate (BER) measurements also are presented for 4- and 8-pulse-position modulation (PPM) modulation schemes with data rates of 20 to 30 Mb/s. A BER of 10-2 is obtained for a mean of 8 detected photons.

Biswas, A.↗

Breaking through the false coincidence barrier in electron–ion coincidence experiments

Photoelectron Photoion Coincidence (PEPICO) spectroscopy holds the promise of a universal, isomer-selective, and sensitive analytical technique for time-resolved quantitative analysis of bimolecular chemical reactions. Unfortunately, its low dynamic range of ~10 3 has largely precluded its use for this purpose, where a dynamic range of at least 10 5 is generally required. This limitation is due to the false coincidence background common to all coincidence experiments, especially at high count rates. Electron/ion pairs emanating from separate ionization events but arriving within the ion time of flight (TOF) range of interest constitute the false coincidence background. Although this background has uniform intensity at every m/z value, the Poisson scatter in the false coincidence background obscures small signals. In this paper, temporal ion deflection coupled with a position-sensitive ion detector enables suppression of the false coincidence background, increasing the dynamic range in the PEPICO TOF mass spectrum by 2–3 orders of magnitude. The ions experience a time-dependent electric deflection field at a well-defined fraction of their time of flight. This deflection defines an m/z- and ionization-time dependent ion impact position for true coincidences, whereas false coincidences appear randomly outside this region and can be efficiently suppressed. When cold argon clusters are ionized, false coincidence suppression allows us to observe species up to Ar 9 + , whereas Ar 4 + is the largest observable cluster under traditional operation. As a result, this advance provides mass-selected photoelectron spectra for fast, high sensitivity quantitative analysis of reacting systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗