72 records · Page 4

Emulsion Chamber Technology Experiment (ECT)

The experimental objective of Emulsion Chamber Technology (ECT) was to develop space-borne emulsion chamber technology so that cosmic rays and nuclear interactions may subsequently be studied at extremely high energies with long exposures in space. A small emulsion chamber was built and flown on flight STS-62 of the Columbia in March 1994. Analysis of the several hundred layers of radiation-sensitive material has shown excellent post-flight condition and suitability for cosmic ray physics analysis at much longer exposures. Temperature control of the stack was 20 +/-1 C throughout the active control period and no significant deviations of temperature or pressure in the chamber were observed over the entire mission operations period. The unfortunate flight attitude of the orbiter (almost 90% Earth viewing) prevented any significant number of heavy particles (Z greater than or equal to 10) reaching the stack and the inverted flow of shower particles in the calorimeter has not allowed evaluation of absolute primary cosmic ray-detection efficiency nor of the practical time limits of useful exposure of these calorimeters in space to the level of detail originally planned. Nevertheless, analysis of the observed backgrounds and quality of the processed photographic and plastic materials after the flight show that productive exposures of emulsion chambers are feasible in low orbit for periods of up to one year or longer. The engineering approaches taken in the ECT program were proven effective and no major environmental obstacles to prolonged flight are evident.

Gregory, John C.↗

Aging properties of Kodak type 101 emulsions

Aging tests for several batches of Kodak type 101 emulsion show that storage conditions significantly influence how well the film will maintain its sensitometric properties, with sensitivity and density increasing to a maximum during this period. Any further aging may result in higher fog levels and sensitivity loss. It is noted that storage in an environment free of photographically active compounds allows film property optimization, and that film batches with different sensitivities age differently. Emulsions with maximum 1700-A sensitivity are 2.5 times faster than those at the low end of the sensitivity scale. These sensitive emulsions exhibit significantly accelerated changes in aging properties. Their use in space applications requires careful consideration of time and temperature profiles, encouraging the use of less sensitive emulsions when the controllability of these factors is limited.

Dohne, B.↗

Studies on immiscible alloys

To illustrate the behavior of immiscible liquids of different densities in zero-gravity and to determine the rate of coalescence like droplets, a demonstration experiment was performed on the Skylab 4 mission. Dispersions of oil-in-water and of water-in-oil were prepared by the astronauts and their appearance photographed over a time span of 10 hours. The experiment indicated that all emulsions were stable over this period and that the coalescent rate was at least 3 times 10 to the 5th power times smaller on Skylab than on earth. The recorded melting of a cylindrical piece of ice on Skylab 3 is used to study the mode of heat transfer for the latent heat of melting in low-gravity.

Otto, G.↗

Holographic studies of the vapor explosion of vaporizing water-in-fuel emulsion droplets

Holographic studies were performed which examined the fragmentation process during vapor explosion of a water-in-fuel (hexadecane/water) emulsion droplet. Holograms were taken at 700 to 1000 microseconds after the vapor explosion. Photographs of the reconstructed holograms reveal a wide range of fragment droplet sizes created during the explosion process. Fragment droplet diameters range from below 10 microns to over 100 microns. It is estimated that between ten thousand and a million fragment droplets can result from this extremely violent vapor explosion process. This enhanced atomization is thus expected to have a pronounced effect on vaporization processes which are present during combustion of emulsified fuels.

Sheffield, S. A.↗

Examples of oil cavitation erosion in positive displacement pumps

The effects of cavitation flow on piston type, positive displacement, hydraulic pumps are discussed. The operating principles of the pump and the components which are most subject to erosion effects are described. The mechanisms of cavitation phenomena are identified from photographic records. Curves are developed to show the solubility of air in water, oil-water emulsion, and industrial hydraulic oil.

Halat, J. A.↗

Metric remote sensing experiments in preparation for Spacelab flights

Aerial and ground photographs of Wallis mountains and of Dolomiti di Cortina d'Ampezzo in Italy were made using spectrozonal emulsions and optical multichannel filters. A metric camera was used in the perspective of the first Spacelab flight aboard the space shuttle. Elementary forms of alpine geomorphology and ice or snow phenomena are detectable on these metric scenes.

Galibert, G.↗

Photographic films for the Multi-Spectral Solar Telescope Array

The rocketborne Multi-Spectral Solar Telescope Array (MSSTA) uses an array of Ritchey-Chretien, Cassegrain, and Herschelian telescopes to produce ultrahigh-resolution full-disk images of the sun within the soft X-ray, EUV, and FUV ranges. Such imaging of the solar disk and corona out to several solar radii placed great demands on the MSSTA's data storage capabilities; in addition, its photographic films required very low outgassing rates. Results are presented from calibration tests conducted on the MSSTA's emulsions, based on measurements at NIST's synchrotron facility.

Hoover, Richard B.↗

Post-development image intensification by autoradiography

A method of post-development intensification of photographic images using a newly developed autoradiographic procedure is described. Radioactive Thiourea-S35 is combined with silver in the developed emulsion, which is then contact printed with a receiver emulsion. The beta decay from S35 produces an enhanced autoradiographic image. The laboratory technique is described and results of astronomical applications are presented.

Askins, B. S.↗

Effects of Shuttle bay environment on UV sensitive photographic film - Instrumentation for Get-Away-Special

An account is given of a Get-Away-Special experiment flown on Space Shuttles 7 and 8 investigating the effect of the space environment on Shumann emulsions. Shumann emulsions, having low gelatin content and no protective gelatin overcoating, are useful detectors of ultraviolet radiation shorter than 2200 angstroms but are extremely sensitive to environmental conditions and handling. The instrument required no interface with the Shuttle. It was turned on by an aneroid switch at an altitude of 50,000 feet. After that, its operation was controlled completely by a CMOS digital controller. Each hour, two temperatures and one voltage were read and stored in a CMOS programmable read only memory. At intervals, valves were opened and closed to expose SO 652 film strips of three sensitivities to the cargo bay environment for various time periods. The design and operation of the instrument package is described.

Kreplin, R. W.↗

S-190 exposure verification flight test

A flight test was conducted to determine the optimum exposures for the Skylab S-190A experiment. An aircraft multispectral photographic system (AMPS) which is installed in the NASA Earth Resources aircraft NP3A was used to simulate the S-190A system. The same film emulsions to be used for S-190A were used in the flight test. These rolls were on factory-loaded spools for use in the AMPS camera system. It was found that some variation is to be expected between these rolls and the S-190A flight loads.

Perry, L.↗

An Investigation of a Photographic Technique of Measuring High Surface Temperatures

A photographic method of temperature determination has been developed to measure elevated temperatures of surfaces. The technique presented herein minimizes calibration procedures and permits wide variation in emulsion developing techniques. The present work indicates that the lower limit of applicability is approximately 1,400 F when conventional cameras, emulsions, and moderate exposures are used. The upper limit is determined by the calibration technique and the accuracy required.

Siviter, James H., Jr.↗

The calibration of photographic and spectroscopic films: 1: A microscopic analysis of IIaO films. 2: The effects of agitation and soaking on IIaO films. 3: The effects of electric field on IIaO films. 4: The effects of X-ray radiation on IIaO films

The grain structure of the emulsion using both reflected and transmission light was examined along with the effects of soaking. The effect of a static charge by a Tesla-coil, and the effects of airport equipment, and dental X-rays on the film were also analyzed.

Hammond, E. C., Jr.↗

Photographic film image enhancement

A series of experiments were undertaken to assess the feasibility of defogging color film by the techniques of optical spatial filtering. A coherent optical processor was built using red, blue, and green laser light input and specially designed Fourier transformation lenses. An array of spatial filters was fabricated on black and white emulsion slides using the coherent optical processor. The technique was first applied to laboratory white light fogged film, and the results were successful. However, when the same technique was applied to some original Apollo X radiation fogged color negatives, the results showed no similar restoration. Examples of each experiment are presented and possible reasons for the lack of restoration in the Apollo films are discussed.

Horner, J. L.↗

Computer simulation of the effects of transmission-averaging in microdensitometry

One of the principal advantages of electrography when compared to photography is the nearly linear relationship between source intensity versus resulting image density. This property allows for simplified and more accurate photometric calibration and permits a certain degree of extrapolation of the calibration to beyond the limits of the faintest photoelectric standard on an exposure. The desires to extract quantitative photometric information from electrographic (or photographic) negatives and to convert this information into a digital format for computer analysis or enhancement led to the widespread use of scanning microdensitometers to perform this A-to-D conversion. Therefore it is of vital importance to understand and, if practical, to avoid any nonlinearities which may be introduced during microdensitometry of electrographic emulsions.

Heckathorn, H. M.↗

Photometric calibration of NGS/POSS and ESO/SRC plates using the NOAO PDS measuring engine. II - Surface photometry

In this paper we present a method to calibrate surface photometry of faint sources measured from direct photographic plates, such as those of the NGS/POSS and ESO/SRC Sky Survey. This calibration procedure does not require scanning sensitometer spots on the plates, but instead uses measurements of the brightness profiles of many faint stars of known brightness to fit a linearized approximation to the characteristic curve. The approximation is valid for only low- to medium-density emulsions, so this technique is appropriate only for relatively faint emission. Comparison between measurements of representative extended sources on the NGS/POSS and CCD images indicates that surface photometry can be obtained from the Sky Survey plates accurate to 0.1-0.3 mag in the range mu(B) between 23 and 27 and mu(R) between 22 and 26 mag/sq arcsec.

Cutri, Roc M.↗

EUV/FUV response characteristics of photographic films for the Multi-Spectral Solar Telescope Array

The photographic film employed by NASA's Multi-Spectral Solar Telescope Array must have high-to-ultrahigh resolution; since the spacecraft bearing the telescope must be evacuated to prevent the failure of delicate EUV and soft X-ray filters due to acoustic vibration during launch, the films must also have very low outgassing rates. An account is presently given of the properties of important new emulsions selected for flight, together with response-characteristics data for the experimental XUV 100 film and an uncoated Spectroscopic 649 emulsion.

Hoover, Richard B.↗

Quantitative analysis of autoradiographic image intensification using Thiourea-S35

Photographic images enhanced by the method of Thiourea-S35 autoradiography are evaluated in terms of signal-to-noise ratio, detective quantum efficiency (DQE), and Wiener spectrum analysis using digitized images. It is determined that the original signal-to-noise ratio is not degraded by the intensification process which allows an increase in the practical working DQE as a function of density. These results apply at all spatial frequencies that were tested. The advantage given by autoradiography is the ability to produce usable images from emulsions originally exposed to the low densities corresponding to maximum DQE and movement of faint image densities above the level of the threshold for detection.

Askins, B. S.↗

ON THE ACCURACY OF MEASUREMENTS MADE UPON FILMS PHOTOGRAPHED BY BAKER-NUNN SATELLITE TRACKING CAMERAS

The photographs taken by the Baker-Nunn cameras of the Smithsonian Astrophysical Observatory were formerly measured with Van Biesbroeck goniometers, but are now measured exclusively with Mann two-screw comparators. Instead of measuring point images, we usually have to measure oblong images, either trails or breaks (the latter produced by interruption of the exposure). We can therefore expect that the accuracy of the determination of their positions is more influenced by the personal errors than it is in conventional astrometry. Approximately 800 measurements were made on 34 images of different length, and, from these, the frequency distribution of settings was determined. Then the relationship between this distribution and the length of the image (trail or break) was examined, and the relationship between the "magnitude error" and the length of image was determined. Measurements were made at different angles formed by the trails and the reticle lines, and it was found that the accuracy was not affected by the angle of the setting. Position determinations have been made using reference stars at different distances. On the basis of these results, we can conclude that the accuracy is neither influenced by the distortion of the emulsion nor by the optical distortion within an area of a diameter of S cm (5°.8). We believe that we are justified in using the linear plate constant method, at least within this area. From numerous double and multiple measurements, the following standard errors were determined for a single position.