Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOGRAPHIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermophysical Property Measurements in the MSFC ESL

Electrostatic Levitation (ESL) is an advanced technique for containerless processing of metals, ceramics, and semiconductors. Because no container is required, there is no contamination from reaction with a crucible, allowing processing of high temperature, highly reactive melts. The high vacuum processing environment further reduces possible contamination of the samples. Finally, there is no container to provide heterogeneous nucleation sites, so the undercooled range is also accessible for many materials. For these reasons, ESL provides a unique environment for measuring thermophysical properties of liquid materials. The properties that can be measured in ESL include density, surface tension, viscosity, electrical and thermal conductivity, specific heat, phase diagram, TTT- and CCT- curves, and other thermodynamic properties. In this paper, we present data on surface tension and viscosity, measured by the oscillating drop technique, and density, measured by an automated photographic technique, measured in the ESL at NASA Marshall Space Flight Center.

Hyers, R. W.↗

ON THE ACCURACY OF MEASUREMENTS MADE UPON FILMS PHOTOGRAPHED BY BAKER-NUNN SATELLITE TRACKING CAMERAS

The photographs taken by the Baker-Nunn cameras of the Smithsonian Astrophysical Observatory were formerly measured with Van Biesbroeck goniometers, but are now measured exclusively with Mann two-screw comparators. Instead of measuring point images, we usually have to measure oblong images, either trails or breaks (the latter produced by interruption of the exposure). We can therefore expect that the accuracy of the determination of their positions is more influenced by the personal errors than it is in conventional astrometry. Approximately 800 measurements were made on 34 images of different length, and, from these, the frequency distribution of settings was determined. Then the relationship between this distribution and the length of the image (trail or break) was examined, and the relationship between the "magnitude error" and the length of image was determined. Measurements were made at different angles formed by the trails and the reticle lines, and it was found that the accuracy was not affected by the angle of the setting. Position determinations have been made using reference stars at different distances. On the basis of these results, we can conclude that the accuracy is neither influenced by the distortion of the emulsion nor by the optical distortion within an area of a diameter of S cm (5°.8). We believe that we are justified in using the linear plate constant method, at least within this area. From numerous double and multiple measurements, the following standard errors were determined for a single position.

ASTROMETRY↗

Photography and photographic-photometry of the solar aureole

This paper describes procedures for taking solar aureole photographs with conventional small format (35- or 70-mm) cameras and films and discusses photographic-photometry techniques for obtaining accurate solar aureole radiance measurements from these photographs, the measurements being used for retrieving atmospheric aerosol characteristics. The photographic data reduction techniques discussed here include sensitometry, densitometry, off-axis illumination distribution measurement, photogrammetry and photometry relations, etc. Comparison tests show that photographic measurements of the solar aureole radiance agree well with simultaneous photoelectric measurements.

Deepak, A.↗

Measuring internal dimensions of small transparent objects

Technique individually photographs first the orifice in the transparent object and then a microscopic scale immersed in a liquid having the same index of refraction as the transparent object. Using a scale photograph, the orifice photograph is measured.

Mills, S. M.↗

The usefulness of a flying spot digitizer for the measurement of the coordinates of star images on photographic plates

The flying spot digitizer can measure the coordinates of star images on photographic plates in one pass with an accuracy of 4.8 microns r.m.s. error. A field of the size 50 x 100 square millimeters is measured in a few seconds. Suggestions are made as to how a better accuracy can be achieved through the way in which the measurements are arranged and by repetition of the measurements. It is suggested that the speed of photographic astrometric measurements can be improved by about two orders of magnitude, at no loss of accuracy, by proper use of the FSD.

Eichhorn, H.↗

Effects of shuttle bay environment on UV sensitive photographic film results of measurements aboard STS-7 and STS-8

Schumann emulsions, having low gelatin content and no protective gelatin overcoating, are extremely sensitive to environmental conditions and handling. Experiments using this emulsion are to be flown on the space shuttle within the cargo-bay. Because the environment of the cargo-bay is unknown, a Get-Away-Special payload was designed to expose Kodak-type SO 652 Schumann emulsion to the residual atmosphere of the cargo-bay. The experiment was programmed to make exposures for various time periods to determine the maximum length of time the film could be exposed in making a measurement and what precautions would be required to preserve the film during ascent into orbit and reentry. The results of the STS-7 and STS-8 flights indicated that long exposures in the shuttle bay do not produce high fog levels in orbit. Observations of severe bleaching of the latent image makes protection of the emulsion during reentry manditory and increase of fog levels with time set a limit of four weeks (preferably less than three) between installation and recovery of the emulsion for processing.

Kreplin, R. W.↗

Photographic time studies of airplane paths

The object of this report is the description of a method which seems to be practicable for determining the path of an airplane, especially in taking off and landing. This report tells how, by means of a camera, preferably a kinetograph, which simultaneously photographs a stop watch the distance of an airplane from the camera and its height above the ground can be determined.

TIMING APPARATUS - SPEED PHOTOGRAPHIC↗

Determination of dynamic corrections to point coordinates of photographs obtained by the Zond 6 and Zond 8 spacecraft

The linear and angular motions of the Zond 6 and Zond 8 spacecraft imaging camera during the exposure cause displacements of the optical image points. In the case of instantaneous exposure of each individual point and the nonsimultaneous exposure of the complete frame, this leads to finite geometric shifts of the points without causing blurring of the photographic image. Therefore, when measuring the resulting photographic pictures, the problem arises of reducing the picture point positions to a common instant of time. This reduction is performed by means of dynamic corrections to the measured picture point coordinates. These corrections are found by using formulas of dynamic photogrammetry. Their use with the Zond space probe photographs is described.

Kiselev, V. V.↗

Photographic films as remote sensors for measuring albedos of terrestrial surfaces

To test the feasibility of remotely measuring the albedos of terrestrial surfaces from photographic images, an inquiry was carried out at ground level using several representative common surface targets. Problems of making such measurements with a spectrally selective sensor, such as photographic film, have been compared to previous work utilizing silicon cells. Two photographic approaches have been developed: a multispectral method which utilizes two or three photographic images made through conventional multispectral filters and a single shot method which utilizes the broad spectral sensitivity of black and white infrared film. Sensitometry related to the methods substitutes a Log Albedo scale for the conventional Log Exposure for creating characteristic curves. Certain constraints caused by illumination goemetry are discussed.

Pease, S. R.↗

Radiative transfer effects behind reflected shock waves

Theoretical studies are reported which were largely centered on the nonequilibrium coupling of collisional, ionization, and radiative transfer processes behind reflected shock waves in nitrogen. Experimental studies included broad-band photomultiplier radiative intensity measurements, luminosity photographs of the reflected shock wave front, end-wall heat transfer measurements, and reflected shock velocity time-history measurements. The results of these activities are summarized, and comparisons between the theoretical and experimental results are discussed.

Nerem, R. M.↗

The intercrater plains of Mercury and the Moon: Their nature, origin and role in terrestrial planet evolution. Measurement and errors of crater statistics

Planetary imagery techniques, errors in measurement or degradation assignment, and statistical formulas are presented with respect to cratering data. Base map photograph preparation, measurement of crater diameters and sampled area, and instruments used are discussed. Possible uncertainties, such as Sun angle, scale factors, degradation classification, and biases in crater recognition are discussed. The mathematical formulas used in crater statistics are presented.

Leake, M. A.↗