Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Commissioning of Robotic Inspection and Automated Analysis System for Assay of Gas Diffusion Piping - 19500

Robotic, in-pipe, nondestructive assay (NDA) is a revolutionary and important means for measuring, analyzing, and reporting radioactive holdup deposits in enrichment piping. This innovation promises vast advantages for efficiency, safety, and cost savings. Payoff, however, lies in utilization much more than innovation. Crossing that threshold from a technical capability to an everyday tool occurs only after rigorous commissioning, adoption, and infusion. This must meet the highest standard, and there can be no compromise. Certification of a new NDA technology must meet the highest standards for quality, safety, and efficacy. Prior to this work, there was no precedent of procedure and method for certification of a robotic methodology for this purpose. The best of robotics had not certified NDA. The best of NDA had not certified robotics. Hence, a great deal of discovery, resourcefulness, and collaboration contributed to this success. This paper chronicles the first-of-kind chartering, co-development, testing, documentation, and site integration that certified this trailblazing in-pipe, robotic NDA. Commissioning had to demonstrate and certify end-to-end NDA automation from robot traversal to computer analysis to report generation of contaminated process piping at the Portsmouth, Ohio gaseous diffusion facility. This was a rigorous campaign of tests, evaluations, and documentation. Highlights included multiple tests in four elevated pipes exercised the gamut of NDA and robotic capabilities. Each of the four test pipes presented a unique loading of U-235. The tests demonstrated operations in both 30- inch and 42-inch diameter pipes with varying lengths and terminated by a variety of valves and fittings. Tests in a fifth pipe at floor level demonstrated deployment and applicability for pipes at this ground height and robot recognition of another fitting type. All operations, calibration, deployment, auto-reporting, and analysis were handled by Portsmouth site personnel. These tests concluded a series of component-level acceptance tests which certified all constituent technologies and operational features. Test metrics included comparison of reported to ground truth results and assessment of data quality from quality assurance and replicate measurement comparison. Beyond the radiometry associated with any NDA method, this unique commissioning path exercised and evaluated all the robotic features that are intrinsic to automation. These include odometry, geometric modeling, autonomy, remote launch and recovery, and end-to-end data flow. Each of these required verification and certification. These evaluations were first-of-kind for the decommissioning community, requiring innovation and resourcefulness in their own right. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on the heat removal for fuel debris using heat pipes

Simple method to retrieve fuel debris by meta-stabilizing: Heat removal system is needed. Heat removal using heat pipes: Cover fuel debris with geopolymer. What is a heat pipe: Heat transport medium with cycles of evaporation and condensation. It consists of the container, working fluid, and the wick. Advantage: Internal vacuum structure, small amount of working fluid, Massive heat transfer due to high-speed movement of hydraulic fluid. Cycle of hydraulic fluid with capillary structure. Because the cycle works independently of gravity, we can set heat pipes at free angle. We evaluated the availability of heat pipes within PCV. Investigation of hydrogen and oxygen concentration of internal gas collected by water replacement method: Non-condensable gas was confirmed inside the heat pipe irradiated by gamma rays. The heat removal effect by the heat pipe greatly descends to the extent close to the copper pipe by Gamma ray irradiation. The above reason was presumed to be that non-condensable gas was generated by radiolysis and the active length of the condensation part of the heat pipe decreased. Counter measures to decrease the amount of non-condensable gas is necessary for using heat pipes under radiation environment. We are doing the experiments to check changes in non-condensable gas generation by using catalysts or other kinds of liquids under Gamma ray irradiation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phenomena Identification and Ranking Table (PIRT) for Heat Pipes

This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Sustainble dropwise condensation enabled ultraefficient heat pipes

Heat pipes play a critical role in determining the operations, safety, and energy efficiency of electronics. The main focus to improve the heat pipe performance is on the evaporator design or wicking structures. However, the intrinsic limitation comes from the condenser, which is fundamentally constrained by inefficient filmwise condensation (FWC). In this study, we successfully achieved a peak effective thermal conductivity (k eff ) of ~140 kW/(m·K) on widely used groove heat pipes by implementing sustainable dropwise condensation (DWC) and integrating with enhanced evaporator. To better understand the working mechanisms of the ultraefficient heat pipe, both the evaporator and condenser of the heat pipes have been modified accordingly. Our results show that up to 296% enhancements on the k eff can be achieved under various inclination angles by only inducing DWC in the condenser section. The drawback of temperature fluctuations induced by DWC in smooth heat pipes appears to be effectively solved using the grooves-wicking structure. Furthermore, by integrating the nanostructured evaporator, the k eff of the heat pipe can be boosted up to 517% compared to conventional groove heat pipes. This study, for the first time, demonstrates the huge potential of engineering both the condenser and evaporator simultaneously in developing ultraefficient heat pipes.

42 ENGINEERING↗

System and method for passive assay of holdup deposits in nuclear piping

Disclosed herein are a method, apparatus, and software for passive, non-destructive assay of holdup deposits in nuclear piping by in-pipe apparatus. A detector deployed within a pipe is collimated to observe radiation impinging radially inward from decay of deposits that lie on the pipe wall. A radiation detector is centered in the pipe and collimated by a pair of coaxial shielding discs disposed equidistant from the detector. This arrangement causes radiation from a truncated cylinder of pipe deposit within a field of regard to impinge on the detector, while precluding radiation emanating from pipe walls beyond the field of regard from reaching the detector. Hence, observations are unique to a known cylindrical length of pipe. The detector assembly is translated through pipes by an autonomous mobile robotic apparatus. Computer software controls the robotic apparatus, logs data, and post-processes to assay deposits.

Whittaker, William Lawrence↗

Experimental analysis on a 1:2 scale model of the double light pipe, an innovative technological device for daylight transmission

In this paper the authors present the double light pipe, an innovative technological device, designed as an evolution of a traditional light pipe, which distributes daylight to underground areas of a building, illuminating, at the same time, the passage areas thanks to a larger collector and a second transparent pipe attached to the first one. Unlike the traditional light pipe, thanks to this double illuminating function it can be located in the middle of a room, despite its encumbrance. In this paper the technological design of the double light pipe is presented and the results of an experimental analysis on a reduced scale (1:2) model are shown. Internal illuminance data over horizontal and vertical work-planes were measured in various sky conditions with or without direct solar radiation. Being this innovative device obtained by a light pipe integrated with a second pipe, it performs like a traditional light pipe for the final room and, at the same time, illuminates the intermediate room giving it uniform and high quality light, particularly indicated for wide plant areas, such as show-rooms or museums. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The three-dimensional structure of swirl-switching in bent pipe flow

Swirl-switching is a low-frequency oscillatory phenomenon which affects the Dean vortices in bent pipes and may cause fatigue in piping systems. Despite thirty years worth of research, the mechanism that causes these oscillations and the frequencies that characterise them remain unclear. In this paper, we show that a three-dimensional wave-like structure is responsible for the low-frequency switching of the dominant Dean vortex. The present study, performed via direct numerical simulation, focuses on the turbulent flow through a $90^{\circ }$ pipe bend preceded and followed by straight pipe segments. A pipe with curvature 0.3 (defined as ratio between pipe radius and bend radius) is studied for a bulk Reynolds number $Re=11\,700$ , corresponding to a friction Reynolds number $Re_{\unicode[STIX]{x1D70F}}\approx 360$ . Synthetic turbulence is generated at the inflow section and used instead of the classical recycling method in order to avoid the interference between recycling and swirl-switching frequencies. The flow field is analysed by three-dimensional proper orthogonal decomposition (POD) which for the first time allows the identification of the source of swirl-switching: a wave-like structure that originates in the pipe bend. Contrary to some previous studies, the flow in the upstream pipe does not show any direct influence on the swirl-switching modes. Finally, our analysis further shows that a three-dimensional characterisation of the modes is crucial to understand the mechanism, and that reconstructions based on two-dimensional POD modes are incomplete.

42 ENGINEERING↗

Heat Pipe Cooled Microreactors

Microreactor technologies are required to provide reliable carbon-free power generation in remote applications. The heat pipe cooled microreactor concept in particular offers notable advantages due to the passive operation of heat pipes enabling increased reliability and simplicity in a more compact form factor. There is a significant need for experimental work to aid and expedite the deployment of heat pipe microreactors due to their unique technological characteristics. Thus, there has been increased interest in heat pipe experiments by numerous institutions in order to support these efforts. The present work is a comprehensive review of heat pipe experiments, describing instrumentation, methods, phenomena of interest, and recent developments. In addition, legacy work on the operation of high-temperature heat pipes under irradiation is reviewed and discussed. Furthermore, the verification and validation efforts for the flagship heat pipe simulation code Sockeye are reviewed and requirements for future experiments are outlined. Lastly, future directions are proposed for heat pipe experimentation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of Heat Pipe Failures in Microreactors

Microreactors provide new opportunities for nuclear reactor applications given their long-lived fuel source, compact size, portability, reliability as it relates to safety and their self-regulating nature. To take advantage of these opportunities there are technological challenges that need to be overcome. One advancing technology often used in conjunction with microreactor designs are heat pipes, which are used for heat removal from the reactor core to the power conversion system. Heat pipes are a substitute for the traditional system in which the same fluid used as coolant in the reactor is then used as the working fluid in the power conversion system. This document describes how heat pipes operate, what happens when a heat pipe fails, and what codes can be used to simulate the results. Our analyses show that a single/double heat pipe failure results in a temperature increase of 15-50°C respectively in surrounding heat pipes. Heat pipe microreactors could be easily designed such that this increase is within the maximum parameters allowable for safety and does not result in cascading heat pipe failure. Thus, such failures do not lead to severe degradation of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial Evaluation of Nek-2P for Modeling of Liquid Metal Heat Pipes

A heat pipe is two-phase heat transfer device which relies on surface tension and capillary pressure to provide a very efficient heat transfer mechanism. Currently, there is interest in designing micro nuclear power reactors using high temperature heat pipes to provide totally passive cooling. To support this, heat pipe simulation capabilities must be developed. The spectral element multiphase CFD code, Nek-2P is being considered for use in providing high-fidelity results which will drive the development of reduced order models. This work is focused on an initial evaluation of the capabilities of Nek-2P to meet this goal. The two-fluid model is used in Nek-2P along with a set of closure models formulated for simulating heat pipes. Specifically, an interfacial force modeling the surface tension effect in the pores of the wick is included. Initial simulations using this model have been performed for conditions approaching nominal values for a sodium heat pipe. Nek-2P is able to qualitatively reproduce the expected results for the volume fraction, velocity, and pressure distributions with reasonable results for the phasic temperatures. This indicates the viability of using Nek-2P to perform more in-depth investigations. However, significant quantitative differences are noted between results and conditions typical of a sodium heat pipe. These differences in results are expected to diminish as the differences between the simulated conditions and the target conditions decreases. Additionally, challenges in simulating heat pipes with Nek-2P have been identified. Future work will focus on addressing these challenges and performing investigations of the operational limits of sodium heat pipes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Project Title: Development of a Pipe Crawler Inspection Tool for Fossil Energy Power Plants (Final Report)

This research effort focuses on the development of a pipe crawler inspection tool for fossil energy power plants. The pipe crawler is tethered and can navigate through 2 inch pipes that are often found in various systems within a power plant. The crawler can navigate through straight pipes and 180 degree elbows and includes instrumentation that can assess the integrity of the pipes. The sensors include a UT sensor for measuring the thickness of the pipe, a range finder and a camera. An additional module is used to prep the surface of the pipe prior to taking thickness measurements. Both bench scale and engineering scale testing was conducted to demonstrate the concept. Multiple crawlers were created and tethered together to distribute the load of the tether so that the crawler can navigate longer pipe distances.

01 COAL, LIGNITE, AND PEAT↗

Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki↗

Friction Stir Welding of Line-Pipe Steels

Friction stir welding (FSW) offers both economic and technical advantages over conventional fusion welding practices for welding line-pipe. For offshore line-pipe construction, the economic savings has been shown to be considerable, approaching a calculated 25%. Offshore pipe is relatively small diameter but heavy wall compared to onshore pipe. One concern is the ability to achieve consistent full weld penetration in an on-site offshore FSW operation, e.g., on a lay-barge. In addition, depending on the size and morphology of the unwelded zone, lack of penetration at the weld root can be difficult if not impossible to detect by conventional NDE methods. Thus, an approach to assure consistent full penetration via process control is required for offshore line-pipe construction using FSW. For offshore construction, an internal structural mandrel can be used offering the opportunity to use a sacrificial anvil FSW approach. With this approach, a small volume of sacrificial material can be inserted into the structural anvil. The FSW tool penetrates into the sacrificial anvil, beyond the inner diameter of the pipe wall, thus assuring full penetration. The sacrificial material is subsequently removed from the pipe inner wall. In the work presented herein, FSW studies were completed on both 6 mm and 12 mm wall thickness line-pipe. Lastly, post-FSW evaluations including radiography, root-bend tests, and metallography demonstrated the merits of the sacrificial anvil approach to achieve consistent full penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RCUT: A Non-Invasive Method for Detection, Location, and Quantification of Radiological Contaminants in Pipes and Ducts - 12514

Radiological Characterization Using Tracers (RCUT) is a minimally invasive method for detection and location of residual radiological contamination in pipes and ducts. The RCUT technology utilizes reactive gaseous tracers that dissociate when exposed to gamma and/or beta radiation emitting from a radiological contaminant in a pipe or duct. Sulfur hexafluoride (SF{sub 6}) was selected as a tracer for this radiological application, because it is a chemically inert gas that is both nonflammable, nontoxic, and breaks down when exposed to gamma radiation. Laboratory tests demonstrated that the tracer pair of SF{sub 6} and O{sub 2} formed SO{sub 2}F{sub 2} when exposed to a gamma or beta radioactive field, which indicated the presence of radiological contamination. Field application of RCUT involves first injecting the reactive tracers into the pipe to fill the pipe being inspected and allowing sufficient time for the tracer to interact with any contaminants present. This is followed by the injection of an inert gas at one end of the pipe to push the reactive tracer at a known or constant flow velocity along the pipe and then out the exit and sampling port at the end of the pipeline where its concentration is measured by a gas chromatograph. If a radiological contaminant is present in the pipe being tested, the presence of SO{sub 2}F{sub 2} will be detected. The time of arrival of the SO{sub 2}F{sub 2} can be used to locate the contaminant. If the pipe is free of radiological contamination, no SO{sub 2}F{sub 2} will be detected. RCUT and PCUT are both effective technologies that can be used to detect contamination within pipelines without the need for mechanical or human inspection. These methods can be used to detect, locate, and/or estimate the volume of a variety of radioactive materials and hazardous chemicals such as chlorinated solvents, petroleum products, and heavy metals. While further optimization is needed for RCUT, the key first step of identification of a tracer compound appropriate for the application of detecting radioactive pipeline contamination through the detection of decomposition products of SF{sub 6} has been demonstrated. Other tracer gases that will also undergo radiolysis will be considered in the future. The next step for the RCUT development process is conducting laboratory scale tests using short pipelines to define analytical requirements, establish performance boundaries, and develop strategies for lower exposure levels. Studies to identify additional analytical techniques using equipment that is more field rugged than a GC/MS would also be beneficial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Screen-Covered Grooved Sodium Heat Pipes for Microreactor Applications

New nuclear reactor designs that incorporate heat pipes are being investigated for possible near-term deployment in terrestrial applications. Here, this study explores the use of screen-covered axially grooved sodium heat pipes and their applicability for providing heat removal for microreactors. A sodium working fluid is appropriate for microreactors operating in the 5 to 20 MW(thermal) range at approximately 650°C. HTPIPE, a legacy software code, was validated for the case of screen-covered grooves and used to perform steady-state analyses to determine the performance limits of a proposed heat pipe design. The performance limits of a sodium heat pipe with a screen-covered square grooved wick structure is compared to that of an equivalent heat pipe with an annular wick. In a horizontal orientation at an operating temperature of 650°C,the performance limits for the heat pipe with an annular wick configuration are 15% higher than for the screen-covered grooved wick. At operating temperatures below 777°C, the annular wick outperforms the screen-covered grooved wick, and at temperatures above 777°C, the screen-covered grooved wick outperforms the annular wick. However, the marginal performance gain at higher temperatures may not justify the use of heat pipes with a screen-covered grooved wick structure due to increased manufacturing costs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical Analysis of JNES Seismic Tests on Degraded Combined Piping System

Nuclear power plant safety under seismic conditions is an important consideration. The piping systems may have some defects caused by fatigue, stress corrosion cracking, etc., in aged plants. These cracks may not only affect the seismic response but also grow and break through causing loss of coolant. Therefore, an evaluation method needs to be developed to predict crack growth behavior under seismic excitation. This paper describes efforts conducted to analyze and better understand a series of degraded pipe tests under seismic loading that was conducted by Japan Nuclear Energy Safety Organization (JNES). A special 'cracked-pipe element' (CPE) concept, where the element represented the global moment-rotation response due to the crack, was developed. This approach was developed to significantly simplify the dynamic finite element analysis in fracture mechanics fields. In this paper, model validation was conducted by comparisons with a series of pipe tests with circumferential through-wall and surface cracks under different excitation conditions. These analyses showed that reasonably accurate predictions could be made using the abaqus connector element to model the complete transition of a circumferential surface crack to a through-wall crack under cyclic dynamic loading. The JNES primary loop recirculation piping test was analyzed in detail. This combined-component test had three crack locations and multiple applied simulated seismic block loadings. Comparisons were also made between the ABAQUS finite element (FE) analyses results to the measured displacements in the experiment. Good agreement was obtained, and it was confirmed that the simplified modeling is applicable to a seismic analysis for a cracked pipe on the basis of fracture mechanics. Pipe system leakage did occur in the JNES tests. The analytical predictions using the CPE approach did not predict leakage, suggesting that cyclic ductile tearing with large-scale plasticity was not the crack growth mode for the acceleration excitations considered here. Hence, the leakage was caused by low-cycle fatigue with small-scale yielding. The procedure used to make predictions of low-cycle fatigue crack growth with small-scale yielding was based on the Dowling {Delta}J procedure, which is an extension of linear-elastic fatigue crack growth methodology into the nonlinear plasticity region. The predicted moments from the CPE approach were used using a cycle-by-cycle crack growth procedure. The predictions compare quite well with the experimental measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE↗