Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Update on the Juncture Flow PIV Results and Future Plans

A novel, embedded, 2D Particle Image Velocimetry system has been developed and implemented to obtain off-body velocity measurements in the junction of an 8% wing-body configuration in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. Although the initial purpose for implementing the system during this test was to evaluate system performance and identify potential risks, a considerable amount of data were obtained in the wing-fuselage junction near the trailing edge at a Reynolds Number of 2.4 Million and angle of attack of 5 degrees. In addition to providing notable efficiencies with regard to image acquisition and test operations, the PIV system captured unique details of the flow separation to complement the extensive suite of measurement techniques applied during the test. Instantaneous PIV vector fields reveal that the flow separation is not stationary but rather highly dynamic. Mean flow statistics calculated from the PIV measurements highlight where reverse flow and Reynolds stresses are concentrated in the separated region and agree well with results from the embedded Laser Doppler Velocimeter system and Computational Fluid Dynamics. The comparisons and ional insight gained during this effort will help guide system improvements for the upcoming entry in 2020.

Jenkins, Luther N.↗

Plug20 Test Report: Particle Image Velocimetry (PIV) Measurements

This report provides turbulent flow statistics made using particle image velocimetry (PIV) for several internally mixed exhaust systems with external plugs (Plug20 designs). The tests were conducted at the NASA Glenn Research Center’s Aero-Acoustic Propulsion Laboratory (AAPL) in May and June 2022. The corresponding acoustic data for the configurations and flows presented in this report can be found in an earlier Technical Memorandum, NASA/TM-20210010291, “Plug20 Test Report.” The Plug20 nozzle family was designed to represent commercial supersonic vehicles in the 2025 to 2035 timeframe with a bypass ratio around 4, having an internal mixer, with and without an external plug to improve nacelle boattail drag and shock. The flow conditions measured represent engine cycles for commercial supersonic aircraft at takeoff, having pressure ratios of 2.0 and heated fan and core streams, measured both with and without a flight stream surrounding the plume. A few unheated flow conditions were also tested to tie results to other baseline test results. The PIV measurements in both streamwise and cross-stream planes are described, along with brief analysis to visually catalog the contents and confirm their validity. In this analysis, the streamwise PIV is found to match benchmark datasets within its experimental error. However, the cross-stream turbulent quantities measured by two systems do not match each other or the streamwise measurements in amplitude—caution is required when using the cross-stream data. Data acquired and included in this report are (1) velocity statistics of the plumes in both a streamwise and several cross-stream planes, and (2) the hot nozzle geometry. Tabular forms of the data and computer-aided design (CAD) files of the hot geometry are presented as supplemental files described in Appendix A (TM-20230006779SUPPL1.zip) and Appendix B (TM-20230006779SUPPL2.zip).

Turbulence↗

SYSTEMATIC MULTI-INDEX VALIDATIONS OF SIDI ENGINE FLOW FIELD LES COMPUTATIONS USING CRANK ANGLE-RESOLVED PIV MEASUREMENTS

In-cylinder flow fields make significant impacts on the fuel atomization, fuel mixture formation, and combustion process in spark ignition direct injection (SIDI) engines. In recent years, model-based simulation approaches are preferred in regard to investigating the transient in-cylinder flow field characteristics. Most commonly, the simulation models are validated using single representative flow field at a typical crank angle measured by particle image velocimetry (PIV). However, it provides only limited knowledge about the flow field which is highly three-dimensional and of transient nature. In this study, crank angle-resolved Ply measurements are conducted on three distinct planes inside the cylinder to capture the transient process of flow field characteristics which vary with the crank angle. These three planes consist of one tumble plane through the spark plug tip, one tumble plane along two intake ports, and one swirl plane at 30 mm below the cylinder head. Large eddy simulation (LES) is employed for the numerical computations using the CONVERGE codes. On the basis of large datasets for both temporal and spatial domains, a multi-index systematic validation approach is conducted. Crank angle-resolved calculations of global indices and local indices are implemented using the flow fields velocity data obtained from both PIV and LES on select planes. Global indices reveal the trends in similarities of different crank angle degrees and locations, while local indices give the detail comparison results. In summary, with the systematic multi-index validation approach, the crucial crank angle degrees and locations for model verification will be detected. Furthermore, the corresponding critical flow features are analyzed. Practical guideline of flow field validation is proposed.

Crank angle-resolved PIV↗

Stereoscopic PIV measurements of swirling flow entering a catalyst substrate

This experimental study investigates the stagnation region of a swirling flow entering an automotive catalyst substrate. A methodology is established using stereoscopic particle image velocimetry (PIV) to determine three-component velocity distributions up to 0.2 mm from the catalyst entrance face. In adverse conditions of strong out-of-plane velocity, PIV operating parameters are adjusted for maximum spatial correlation strength. The measurement distance to the catalyst is sufficiently small to observe radial flow spreading. A scaling analysis of the stagnation flow region provides a model for the flow uniformization as a function of the catalyst pressure drop. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Local gas and liquid phase velocity measurement in a miniature stirred vessel using PIV combined with a new image processing algorithm

A method which combines standard two-dimensional particle image velocimetry (PIV) with a new image processing algorithm has been developed to measure the average local gas bubble velocities, as well as the local velocities of the liquid phase, within small stirred vessel reactors. The technique was applied to measurements in a gas-liquid high throughput experimentation (HTE) vessel of 45 mm diameter, but it is equally suited to measurements in larger scale reactors. For the measurement of liquid velocities, 3 {mu}m latex seeding particles were used. For gas velocity measurements, a separate experiment was conducted which involved doping the liquid phase with fluorescent Rhodamine dye to allow the gas-liquid interfaces to be identified. The analysis of raw PIV images enabled the detection of bubbles within the laser plane, their differentiation from obscuring bubbles in front of the laser plane, and their use in lieu of tracer particles for gas velocity analysis using cross-correlation methods. The accuracy of the technique was verified by measuring the velocity of a bubble rising in a vertical glass column. The new method enabled detailed velocity fields of both phases to be obtained in an air-water system. The overall flow patterns obtained showed a good qualitative agreement with previous work in large scale vessels. The downward liquid velocities above the impeller were greatly reduced by the addition of the gas, and significant differences between the flow patterns of the two-phases were observed. (author)

42 ENGINEERING↗

A histogram-based technique for rapid vector extraction from PIV photographs

A new analysis technique, performed totally in the image plane, is proposed which rapidly extracts all available vectors from individual interrogation regions on PIV photographs. The technique avoids the need for using Fourier transforms with the associated computational burden. The data acquisition and analysis procedure is described, and results of a preliminary simulation study to evaluate the accuracy of the technique are presented. Recently obtained PIV photographs are analyzed.

Humphreys, William M., Jr.↗

PIV Data Validation Software Package

A PIV data validation and post-processing software package was developed to provide semi-automated data validation and data reduction capabilities for Particle Image Velocimetry data sets. The software provides three primary capabilities including (1) removal of spurious vector data, (2) filtering, smoothing, and interpolating of PIV data, and (3) calculations of out-of-plane vorticity, ensemble statistics, and turbulence statistics information. The software runs on an IBM PC/AT host computer working either under Microsoft Windows 3.1 or Windows 95 operating systems.

Blackshire, James L.↗

Rotor Wake Vortex Definition: Initial Evaluation of 3-C PIV Results of the Hart-II Study

An initial evaluation is made of extensive three-component (3C) particle image velocimetry (PIV) measurements within the wake across a rotor disk plane. The model is a 40 percent scale BO-105 helicopter main rotor in forward flight simulation. This study is part of the HART II test program conducted in the German-Dutch Wind Tunnel (DNW). Included are wake vortex field measurements over the advancing and retreating sides of the rotor operating at a typical descent landing condition important for impulsive blade-vortex interaction (BVI) noise. Also included are advancing side results for rotor angle variations from climb to steep descent. Using detailed PIV vector maps of the vortex fields, methods of extracting key vortex parameters are examined and a new method was developed and evaluated. An objective processing method, involving a center-of-vorticity criterion and a vorticity 'disk' integration, was used to determine vortex core size, strength, core velocity distribution characteristics, and unsteadiness. These parameters are mapped over the rotor disk and offer unique physical insight for these parameters of importance for rotor noise and vibration prediction.

Burley, Casey L.↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indecies of the fluid, the pump casing and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 90 mmHg and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 2.9%.

Sankovic, John M.↗

Characterization of Unsteady Flow Structures Near Leading-Edge Slat: PIV Measurements - Part 1

A comprehensive computational and experimental study has been performed at the NASA Langley Research Center as part of the Quiet Aircraft Technology (QAT) Program to investigate the unsteady flow near a leading-edge slat of a two-dimensional, high-lift system. This paper focuses on the experimental effort conducted in the NASA Langley Basic Aerodynamics Research Tunnel (BART) where Particle Image Velocimetry (PIV) data was acquired in the slat cove and at the slat trailing edge of a three-element, high-lift model at 4, 6, and 8 degrees angle of attack and a freestream Mach Number of 0.17. Instantaneous velocities obtained from PIV images are used to obtain mean and fluctuating components of velocity and vorticity. The data show the recirculation in the cove, reattachment of the shear layer on the slat lower surface, and discrete vortical structures within the shear layer emanating from the slat cusp and slat trailing edge. Detailed measurements are used to examine the shear layer formation at the slat cusp, vortex shedding at the slat trailing edge, and convection of vortical structures through the slat gap. Selected results are discussed and compared with unsteady, Reynolds-Averaged Navier-Stokes (URANS) computations for the same configuration in a companion paper by Khorrami, Choudhari, and Jenkins (2004). The experimental dataset provides essential flow-field information for the validation of near-field inputs to noise prediction tools.

Jenkins, Luther N.↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indices of the fluid, the pump casing, and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 12 kPa and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 22.9%.

Sankovic, John M.↗

The NASA Subsonic Jet Particle Image Velocimetry (PIV) Dataset

Many tasks in fluids engineering require prediction of turbulence of jet flows. The present document documents the single-point statistics of velocity, mean and variance, of cold and hot jet flows. The jet velocities ranged from 0.5 to 1.4 times the ambient speed of sound, and temperatures ranged from unheated to static temperature ratio 2.7. Further, the report assesses the accuracies of the data, e.g., establish uncertainties for the data. This paper covers the following five tasks: (1) Document acquisition and processing procedures used to create the particle image velocimetry (PIV) datasets. (2) Compare PIV data with hotwire and laser Doppler velocimetry (LDV) data published in the open literature. (3) Compare different datasets acquired at the same flow conditions in multiple tests to establish uncertainties. (4) Create a consensus dataset for a range of hot jet flows, including uncertainty bands. (5) Analyze this consensus dataset for self-consistency and compare jet characteristics to those of the open literature. The final objective was fulfilled by using the potential core length and the spread rate of the half-velocity radius to collapse of the mean and turbulent velocity fields over the first 20 jet diameters.

Bridges, James↗

A Dual-Plane PIV Study of Turbulent Heat Transfer Flows

Thin film cooling is a widely used technique in turbomachinery and rocket propulsion applications, where cool injection air protects a surface from hot combustion gases. The injected air typically has a different velocity and temperature from the free stream combustion flow, yielding a flow field with high turbulence and large temperature differences. These thin film cooling flows provide a good test case for evaluating computational model prediction capabilities. The goal of this work is to provide a database of flow field measurements for validating computational flow prediction models applied to turbulent heat transfer flows. In this work we describe the application of a Dual-Plane Particle Image Velocimetry (PIV) technique in a thin film cooling wind tunnel facility where the injection air stream velocity and temperatures are varied in order to provide benchmark turbulent heat transfer flow field measurements. The Dual-Plane PIV data collected include all three components of velocity and all three components of vorticity, spanning the width of the tunnel at multiple axial measurement planes.

Turbulent heat transfer↗

Stability Analysis of the Flow Over a Swept Forward-Facing Step Using PIV Base Flows

Step excrescences are a type of surface imperfection encountered on swept wings of commercial aircraft, commonly because accessibility requirements prevent creating the wing’s surface from a single panel. If the step height is too large, super-critical, the flow can undergo an early transition to turbulence, which can be highly detrimental for the performance of the wing. In the case of a forward-facing step on a swept wing in a low-disturbance environment, stationary crossflow vortices can develop a significant amplitude upstream of the step and hence dominate the structure of the boundary-layer flow over the step. The main goal of the present investigation is to illuminate the path to transition supported by the fascinatingly complex flow field in the direct downstream vicinity of a step with a super critical height. The high-resolution, stereographic Particle Image Velocimetry (PIV) measurement dataset presently available for this flow field provides a complete description of the laminar flow for the execution of BiGlobal stability analysis in a plane parallel to the step. Although the notorious sensitivity of stability results to the description of the base flow demands a very careful uncertainty analysis of those results, it is argued that this very fact can be leveraged to produce new insight into the supported perturbation dynamics. In performing the analysis, several unsteady mode families are discovered that display the explosive perturbation expected for early transition to be induced. In considering domain widths equal to an integer-multiple of the incident crossflow-vortex wavelength and analyzing an extent of 5 crossflow-vortex wavelengths parallel to the step, it is found that the stability results converge while increasing the domain width. It is demonstrated, moreover, that the results for the wider domains can be approximated by appropriately averaging the results on neighboring single-crossflow-vortex-wavelength domains covering the same region. Besides being useful for computational purposes, this observed property suggests interpreting the instability mechanism as a distorted primary mechanism rather than a “proper” secondary mechanism. This follows in the context of the secondary in-stability analysis of three-dimensional boundary layers, because the secondary mechanism is usually characterized by being localized in a pocket of strong shear, while the distorted primary mechanism typically has an infinite support in the direction parallel to the step. Even though the growth rates are found to be sensitive to the interrogation-window size inherent to the PIV post-processing procedure, the spatial structure of the eigenfunctions is found to be relatively insensitive. Lastly, the spatial structure of the eigenfunctions corresponding to all velocity components are matched with the shape functions determined by computing the Spectral Proper Orthogonal Decomposition (SPOD) of a time-resolved measurement of the perturbation content.

forward-facing step↗

Effects of Porous Gap Fillers on Leading-Edge Slat Noise of 30P30N. Part II: PIV Measurements

The leading edge slat of a high-lift system is one of the main contributors to the airframe noise during approach conditions. This paper, the second of two parts, continues our previous studies on the slat gap filler as a passive noise control device on the two-dimensional, 30P30N multielement airfoil. Whereas the earlier study was focused on the effects of an impermeable gap filler that completely blocks the flow through the gap, this follow-on assessment is devoted to permeable slat gap fillers that allow limited amounts of flow to pass through the gap. Part I of this two-part abstract described the aerodynamic and acoustic effects of the permeable gap fillers, as inferred from both the measurements of static and unsteady surface pressures and the microphone array data for the radiated noise. To understand the physical mechanism responsible for the noise reduction documented in Part I, as well as for the accompanying aerodynamic penalty due to the porous gap fillers, Particle Image Velocimetry (PIV) is used in this paper to measure the flow details in the slat-cove region of the 30P30N model. A single angle of attack (𝛼 = 5.5◦) and a chord based Reynolds number of 1.71𝑒6 are selected as the test conditions. The PIV results show that the slat flow features are significantly altered with the presence of the porous gap filler, resulting in a more stable slat-cove shear layer and, thus, reduced velocity fluctuations with a successive decrease in the permeability. The porous gap filler with the lowest permeability acts similar to the solid gap filler. However, flow separation is observed on the upper side of the porous interface, which leads to an aerodynamic performance penalty via a reduction in lift on the main wing.

slat noise↗

Micro-PIV measurements of multiphase flow of water and liquid CO 2 in 2-D heterogeneous porous micromodels

We present an experimental study of pore-scale flow dynamics of liquid CO 2 and water in a two-dimensional heterogeneous porous micromodel, inspired by the structure of a reservoir rock, at reservoir-relevant conditions (80 bar, 21°C). The entire process of CO 2 infiltration into a water-saturated micromodel was captured using fluorescence microscopy and the micro-PIV method, which together reveal complex fluid displacement patterns and abrupt changes in velocity. The CO 2 front migrated through the resident water in an intermittent manner, forming dendritic structures, termed fingers, in directions along, normal to, and even opposing the bulk pressure gradient. Such characteristics indicate the dominance of capillary fingering through the micromodel. Velocity burst events, termed Haines jumps, were also captured in the heterogeneous micromodel, during which the local Reynolds number was estimated to be ~21 in the CO 2 phase, exceeding the range of validity of Darcy's law. Furthermore, these drainage events were observed to be cooperative (i.e., across multiple pores simultaneously), with the zone of influence of such events extending beyond tens of pores, confirming, in a quantitative manner, that Haines jumps are nonlocal phenomena. After CO 2 completely breaks through the porous section, shear-induced circulations caused by flowing CO 2 were also observed, in agreement with previous studies using a homogeneous porous micromodel. To our knowledge, this study is the first quantitative measurement that incorporates both reservoir-relevant conditions and rock-inspired heterogeneity, and thus will be useful for pore-scale model development and validation.

42 ENGINEERING↗

PIV Logon Configuration Guidance

This document details the configurations and enhancements implemented to support the usage of federal Personal Identity Verification (PIV) Card for logon on unclassified networks. The guidance is a reference implementation of the configurations and enhancements deployed at the Los Alamos National Laboratory (LANL) by Network and Infrastructure Engineering – Core Services (NIE-CS).

97 MATHEMATICS AND COMPUTING↗