Study of Mechanical and Thermal Impact of a Plasma Focus Discharge on Diagnostic Elements of PFM-72M Installation

Mechanical and thermal impact of the plasma focus discharge on structural elements of diagnostic windows of the PFM-72m discharge installation are calculated. The absence of critical impact at early discharge stages and during the first 300 ns after the “plasma focus” formation is shown. The possibility of shock impact on the surface of diagnostic windows at later times, which may result in their substantial deformation and destruction, is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on electron beam in a low energy plasma focus

Electron beam emission was investigated in a low energy plasma focus device (2.2 kJ) using copper hollow anode. Faraday cup was used to estimate the energy of the electron beam. XR100CR X-ray spectrometer was used to explore the impact of the electron beam on the target observed from top-on and side-on position. Experiments were carried out at optimized pressure of argon gas. The impact of electron beam is exceptionally notable with two different approaches using lead target inside hollow anode in our plasma focus device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filamentary structure of plasma produced by compression of puffing deuterium by deuterium or neon plasma sheath on plasma-focus discharge

The present experiments were performed on the PF-1000 plasma focus device at a current of 2 MA with the deuterium injected from the gas-puff placed in the axis of the anode face. The XUV frames showed, in contrast with the interferograms, the fine structure: filaments and spots up to 1 mm diameter. In the deuterium filling, the short filaments are registered mainly in the region of the internal plasmoidal structures and their number correlates with the intensity of neutron production. The longer filamentary structure was recorded close to the anode after the constriction decay. The long curve-like filaments with spots were registered in the big bubble formed after the pinch phase in the head of the umbrella shape of the plasma sheath. Filaments can indicate the filamentary structure of the current in the pinch. Together with the filaments, small compact balls a few mm in diameter were registered by both interferometry and XUV frame pictures. They emerge out of the dense column and their life-time can be greater than hundreds of ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Characteristics of the FN-II Dense Plasma Focus Device

The Fuego Nuevo II (FN-II) dense plasma focus device is a small machine (4.6 kJ), operating at the Instituto de Ciencias Nucleares, UNAM, in which neutrons, as well as soft and hard X rays have been studied with a number of diagnostics. Neutrons are studied with silver activation counters, and scintillator-photomultiplier detectors, while their angular distribution inside and outside the discharge chamber have been studied with CR-39 plastic track detectors. The soft X rays are studied with a multiple-pin-hole camera and PIN diodes, while the hard X-rays are observed with the scintillator-photomultiplier detectors mentioned above. When a needle is inserted on the inner electrode, a bright spot of hard x-rays can be concentrated, and used for the production of high-contrast radiography. Dosimetric measurements have been made for X-rays crossing a 300 micron aluminum window, through the axis of the machine, showing an average dose of 0.11{+-}0.01 mGy per shot. In contrast, the average dose with a hollow cathode is 0.077{+-}0.006 mGy per shot.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of the plasma current sheath in plasma focus discharges in different gases

The shape of the plasma current sheath (PCS) in the final stage of its radial compression, the dynamics of pinching, and the subsequent pinch decay in plasma focus (PF) discharges in different gases are studied using an improved multichannel system of electron-optical plasma photography and a newly elaborated synchronization system. The PCS structure in discharges in heavy gases (Ne, Ar) is found to differ significantly from that in discharges in hydrogen and deuterium. The influence of a heavy gas (Xe) additive to hydrogen and deuterium on the structure and compression dynamics of the PCS is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal and spatial study of neon ion emission from a plasma focus device

The temporal and spatial characteristics of the neon ion beam emissions from a low energy plasma focus device have been studied by employing a multiple Faraday cup assembly and the CR-39 track detectors at different angular and axial positions. In addition, the operating gas pressures were also varied to study the temporal and spatial characteristics of the neon ion beam emissions. The Faraday cup analyses show that the ion flux strongly depends on the operating gas pressure as well as the angular positions. The estimated ion energy measurements at the aperture of the Faraday cup indicate that the plasma focus device is a source of polyenergetic ions ranging from approximately a few keV to a few hundreds of keV, irrespective of the angular positions. The exposed CR-39 detectors have shown the formation of multiple ion tracks with diameter ranging from 2 to 13 {mu}m. The populations of lower diameter tracks (2-6 {mu}m) are observed to be more at 0 deg. and 10 deg. angles. It is also noticed that the most populated track counts have shifted toward the higher diameter as the angular positions change from 0 deg. to 70 deg. The present study enables us to predict a clear picture of ion flux and energy distribution inside the plasma focus chamber that will help to use the device for material irradiation application in a more controlled manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of driver impedance on dense plasma focus Z-pinch neutron yield

The Z-pinch phase of a dense plasma focus (DPF) heats the plasma by rapid compression and accelerates ions across its intense electric fields, producing neutrons through both thermonuclear and beam-target fusion. Driver characteristics have empirically been shown to affect performance, as measured by neutron yield per unit of stored energy. We are exploring the effect of driver characteristics on DPF performance using particle-in-cell (PIC) simulations of a kJ scale DPF. In this work, our PIC simulations are fluid for the run-down phase and transition to fully kinetic for the pinch phase, capturing kinetic instabilities, anomalous resistivity, and beam formation during the pinch. The anode-cathode boundary is driven by a circuit model of the capacitive driver, including system inductance, the load of the railgap switches, the guard resistors, and the coaxial transmission line parameters. It is known that the driver impedance plays an important role in the neutron yield: first, it sets the peak current achieved at pinch time; and second, it affects how much current continues to flow through the pinch when the pinch inductance and resistance suddenly increase. Here we show from fully kinetic simulations how total neutron yield depends on the impedance of the driver and the distributed parameters of the transmission circuit. Direct comparisons between the experiment and simulations enhance our understanding of these plasmas and provide predictive design capability for neutron source applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of pulsed (plasma focus) neutron source with image plate and application to neutron radiography

Plasma focus device of Mather type developed in house has been used first time for neutron radiography of different objects. The device gives (1.2{+-}0.3) Multiplication-Sign 10{sup 9} neutrons per pulse produced by D-D fusion reaction with a pulse width of 50{+-}5 ns. The method involves exposing sample to be radiographed to thermalized D-D neutrons and recording the image on Fuji-film BAS-ND image plates. The thermal neutron component of the moderated beam was estimated using two image plates: a conventional IP for X-rays and gamma rays, and an IP doped with Gd for detecting neutrons.

07 ISOTOPE AND RADIATION SOURCES↗

Scaling, stability, and fusion mechanisms. Studies using plasma focus devices from tens of kilojoules to tenth of joules

Fusion studies using plasma focus devices from tens of kilojoules to less than one joule performed at the Chilean Nuclear Energy Commission are presented. The similarity of the physical behavior and the scaling observed in these machines are emphasized. Experiments on actual devices show that scaling holds at least through six order of magnitude. In particular all of these devices, from the largest to the smallest, keep the same quantity of energy per particle. Therefore, fusion reactions are possible to be obtained in ultraminiature devices (driven by generators of 0.1 J), as they are in the bigger devices (driven by generators of 1 MJ). However, the stability of the plasma depends on the size and energy of the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Backward high energy ion beams from plasma focus

High energy neutrons, more than 2.45 MeV from deuteron-deuteron fusion reaction, have been measured in backward direction of plasma focus devices in many laboratories. However the experimental evidence for high energy deuterons responsible for such neutrons has not been reported so far. In this brief communication, backward high energy deuteron beam from NX2 plasma focus [M. V. Roshan et al., Phys. Lett. A 373, 851 (2009)] is reported, which was measured with a direct and unambiguous technique of nuclear activation. The relevant nuclear reaction for the target activation is {sup 12}C(d,n){sup 13}N, which has a deuteron threshold energy of 328 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Description of plasma focus current sheath as the Turner relaxed state of a Hall magnetofluid

The central mystery of plasma focus research is the two orders-of-magnitude-higher-than-thermal fusion reaction rate and the fact that both the space-resolved neutron spectra and space-resolved reaction proton spectra show features which can be ascribed only to a rotational motion of the center-of-mass of the reacting deuteron population. It has been suggested earlier [S. K. H. Auluck, IEEE Trans. Plasma Sci. 25, 37 (1997)] that this and other experimental observations can be consistently explained in terms of a hypothesis involving rotation of the current carrying plasma annulus behind the imploding gas-dynamic shock. Such rotation (more generally, mass flow) is an in-built feature of relaxed state of a two-fluid plasma [R. N. Sudan, Phys. Rev. Lett. 42, 1277 (1979)]. Relaxation in the 'Hall magnetofluid' approximation, in which the generalized Ohm's law includes the Hall effect term and the magnetic convection term but omits the contributions to the electric field from resistive dissipation, electron pressure gradient, thermoelectric effect, electron inertia, etc., has been extensively studied by many authors. In the present paper, Turner's [IEEE Trans. Plasma Sci. PS-14, 849 (1986)] degenerate solution for the relaxed state of the Hall magnetohydrodynamic plasma has been adapted to the case of an infinitely long annular current carrying plasma, a tractable idealization of the current sheath of a plasma focus. The resulting model is consistent with experimental values of ion kinetic energy and observation of predominantly radially directed neutron emission in good shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of the structure of the plasma current sheath in a plasma focus discharge

The study is aimed at investigating the fine structure of the plasma current sheath (PCS) in the PF-3 plasma focus facility. The PCS dynamics in a deuterium discharge was studied. The PCS parameters were measured using absolutely calibrated magnetic probes installed at different positions with respect to the facility axis and the anode surface. A magneto-optical probe recording both the magnetic signal and the PCS optical luminosity was first applied to analyze the PCS structure. This made it possible to spatially resolve the current and shock-wave regions. It is demonstrated that the current distribution is different in different discharge stages. It is shown that the neutron yield is determined by the value of the current compressed toward the axis, rather then the amplitude of the total discharge current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolved high-resolution x-ray spectroscopy of high-current plasma-focus discharges

Soft x-ray emission from a Mather-type plasma-focus device (PF-1000) operated at {approx}400 kJ was measured. The high density and temperature plasma were generated by the discharge in the deuterium-argon gas mixture in the modified (high-current) plasma-focus configuration. A spherically bent mica crystal spectrograph viewing the axial output of the pinch region was used to measure the x-ray spectra. Spatially resolved spectra including the characteristic x-ray lines of highly ionized Ar and continua were recorded by means of an x-ray film. The x-ray emission of PF-1000 device was studied at different areas of the pinch.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the dense plasma focus for short-pulse applications

The dense plasma focus (DPF) has long been considered a compact source for pulsed neutrons and has traditionally been optimized for the total neutron yield. Here, we describe the efforts to optimize the DPF for short-pulse applications by introducing a reentrant cathode at the end of the coaxial plasma gun. We reduced the resulting neutron pulse widths by an average of 21±921±9% from the traditional long-drift DPF design. Pulse widths and yields achieved from deuterium-tritium fusion at 2 MA are 61.8±30.761.8±30.7 ns FWHM and 1.84±0.49×10121.84±0.49×10 12 neutrons per shot. Simulations were conducted concurrently to elucidate the DPF operation and confirm the role of the reentrant cathode. Furthermore, a hybrid fluid-kinetic particle-in-cell modeling capability demonstrates correct sheath velocities, plasma instabilities, and fusion yield rates. Consistent with previous findings that the DPF is dominated by beam-target fusion from superthermal ions, we estimate that the thermonuclear contribution is at the 1% level.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Runaway electrons as a source of impurity and reduced fusion yield in the dense plasma focus

Impurities produced by the vaporization of metals in the electrodes may be a major cause of reduced fusion yields in high-current dense plasma focus devices. We propose here that a major, but hitherto-overlooked, cause of such impurities is vaporization by runaway electrons during the breakdown process at the beginning of the current pulse. This process is sufficient to account for the large amount of erosion observed in many dense plasma focus devices on the anode very near to the insulator. The erosion is expected to become worse with lower pressures, typical of machines with large electrode radii, and would explain the plateauing of fusion yield observed in such machines at higher peak currents. Such runaway electron vaporization can be eliminated by the proper choice of electrode material, by reducing electrode radii and thus increasing fill gas pressure, or by using pre-ionization to eliminate the large fields that create runaway electrons. If these steps are combined with monolithic electrodes to eliminate arcing erosion, large reductions in impurities and large increases in fusion yield may be obtained, as the I{sup 4} scaling is extended to higher currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Characteristics of Four Small Dense Plasma Focus Devices

Four small (in the energy range 2-7 kJ) dense plasma focus devices were elaborated and put into operation in the last several years: ING-103, DPF-10, PF-5M, and DPF-6. Each device has its own parameters (energy, current rise-time and magnitude, pulse duration of ionizing radiation of different types, weight, etc.) and together with the specific discharge chambers they are optimized for various applications. Comparative description of functioning parameters of these devices together with the results of the most successful applications is presented in the report.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by {approx_equal}1 MJ plasma focus

The spectra of neutrons outside the plasma focus device PF-1000 with an upper energy limit of {approx_equal}1 MJ was measured using a Bonner spheres spectrometer in which the active detector of thermal neutrons was replaced by nine thermoluminescent chips. As an a priori spectrum for the unfolding procedure, the spectrum calculated by means of the Monte Carlo method with a simplified model of the discharge chamber was selected. Differences between unfolded and calculated spectra are discussed with respect to properties of the discharge vessel and the laboratory layout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma focus ion beam fluence and flux—For various gases

A recent paper derived benchmarks for deuteron beam fluence and flux in a plasma focus (PF) [S. Lee and S. H. Saw, Phys. Plasmas 19, 112703 (2012)]. In the present work we start from first principles, derive the flux equation of the ion beam of any gas; link to the Lee Model code and hence compute the ion beam properties of the PF. The results show that, for a given PF, the fluence, flux, ion number and ion current decrease from the lightest to the heaviest gas except for trend-breaking higher values for Ar fluence and flux. The energy fluence, energy flux, power flow, and damage factors are relatively constant from H{sub 2} to N{sub 2} but increase for Ne, Ar, Kr and Xe due to radiative cooling and collapse effects. This paper provides much needed benchmark reference values and scaling trends for ion beams of a PF operated in any gas.