A microwave lens system for plasma diagnostics
Lens system for provision of plane waves at microwave frequency for plasma probing
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lens system for provision of plane waves at microwave frequency for plasma probing
Existence of magnetohydrodynamic waves in interplanetary space from measurements of plasma probe on Mariner II space probe
Techniques for using electrical probes for plasma diagnostics are reviewed. Specific consideration is given to the simple Langmuir probe, the symmetric double probe of Johnson and Malter, the variable-area probe of Fetz and Oeschsner, and a floating probe technique. The advantages and disadvantages of each technique are discussed.
Plans for SEPAC, an instrument array to be used on Spacelab 1 to study vehicle charging and neutralization, beam-plasma interaction in space, beam-atmospheric interaction exciting artificial aurora and airglow, and the electromagnetic-field configuration of the magnetosphere, are presented. The hardware, consisting of electron beam accelerator, magnetoplasma arcjet, neutral-gas plume generator, power supply, diagnostic package (photometer, plasma probes, particle analyzers, and plasma-wave package), TV monitor, and control and data-management unit, is described. The individual SEPAC experiments, the typical operational sequence, and the general outline of the SEPAC follow-on mission are discussed. Some of the experiments are to be joint ventures with AEPI (INS 003) and will be monitored by low-light-level TV.
Supersonic plasma stream diagnostics using immersed microwave probes
Measurement of low frequency impedance of Langmuir probe in plasma to obtain electron density and temperature
Transient ion sheath effects on spherical metallic plasma probe complex admittance at different frequencies, comparing numerical results with experiment
Engineering developments in plasma probes, ionized gas, electron emission, electrochemical fuel cells, solar-thermal energy conversion, and nonlinear heat transfer phenomena
Explorer x plasma probe measurements of positively charged particle fluxes and magnetic fields
Parameters of DC discharge between concentric cylinders calculated for plasma probes by pressure theory, noting ion neutral collisions and magnetic field effects
Sensitive, high resolution plasma probes for analysis of the distribution functions and plasma wave instruments for measurements of electromagnetic and electrostatic wave modes are commonly flown together to provide information on plasma instabilities and wave particle interactions. Analysis of the data for the ISEE 3 mission is provided.
Increasingly long-duration space missions require a better understanding of the failure mechanisms of hollow cathodes to enable prediction of lifetime. Energetic ions have been measured in the plume of hollow cathodes but the energies are higher than can be explained classically. One of the mechanisms that appears to be contributing to the ion heating is ion acoustic turbulence (IAT), which has been investigated with plasma probes recently at JPL. In this work the ion velocity distribution has been measured using laser-induced fluorescence (LIF) at several high-current operating conditions on the centerline of a 100 A class hollow cathode at JPL. A retarding potential analyzer was (RPA) was used to measure the ion energy profile in the far plume and a Langmuir probe was used to measure electron temperature and plasma potential fluctuations. RPA energies are shown to correlate with the values measured by LIF. The ion temperature is shown to increase with distance downstream of the cathode. A parametric study of the ion heating as a function of discharge current and cathode flow rate was performed. It was found that for increasing current the ion temperature evolution did not vary even though the wave IAT wave energy increased. The effect of flow rate was more pronounced, with higher values reducing both ion temperature and wave energy linearly. These results indicate that IAT is at least partially responsible for energetic ion production in the hollow cathode plume.
The current-voltage characteristics of cylindrical probes in a high velocity collisionless plasma flow have been investigated experimentally and theoretically. The plasma was generated by a focused laser pulse incident on a metallic target in vacuum. An analysis, developed from a stationary plasma analog to the flowing case, demonstrated a failure of plasma shielding of probe potential in the electron attracting region. Modifications of relatively simple previous treatments were found to be valid for computing electron current to a probe. The electron characteristics derived from the present analysis agree well with experimental results. The ion and electron portions of the characteristics are consistent with each other and with independent diagnostic measurements.
An enhancement of plasma density observed during a neutral gas injection in Space Experiments with Particle Accelerators by the Space Shuttle/Spacelab-1 is presented. When a plume of nitrogen gas was injected from the orbiter into space, a large amount of plasma was detected by an onboard plasma probe. The observed density often increased beyond the background plasma density and was strongly dependent on the attitude of the orbiter with respect to the velocity vector. This effect has been explained by a collisional interaction between the injected gas molecules and the ionospheric ions relatively drifting at the orbital speed.
Plasma probe manipulators, electromagnetic shielding, receiver signal to noise ratio, and plasma parameters for experiment and measurements on plasma properties
An analysis of the major plasma processes involved in the SERT 2 spacecraft experiments was conducted to aid in the interpretation of recent data. A plume penetration model was developed for neutralization electron conduction to the ion beam and showed qualitative agreement with flight data. In the SERT 2 configuration conduction of neutralization electrons between thrusters was experimentally demonstrated in space. The analysis of this configuration suggests that the relative orientation of the two magnetic fields was an important factor in the observed results. Specifically, the opposed field orientation appeared to provide a high conductivity channel between thrusters and a barrier to the ambient low energy electrons in space. The SERT 2 neutralizer currents with negative neutralizer biases were up to about twice the theoretical prediction for electron collection by the ground screen. An explanation for the higher experimental values was a possible conductive path from the neutralizer plume to a nearby part of the ground screen. Plasma probe measurements of SERT 2 gave the clearest indication of plasma electron temperature, with normal operation being near 5 eV and discharge only operation near 2 eV.
Floating emissive probe plasma potential data are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring-cusp ion thruster. Discharge plasma data are presented with beam extraction at throttling conditions comparable to the NASA TH Levels 8, 12, and 15. The operating conditions of the Extended Life Test (ELT) of the Deep Space One (DS1) flight spare ion engine, where anomalous discharge keeper erosion occurred, were TH 8 and TH 12 consequently they are of specific interest in investigating discharge keeper erosion phenomena. The data do not validate the presence of a potential hill plasma structure downstream of the DCA, which has been proposed as a possible erosion mechanism. The data are comparable in magnitude to data taken by other researchers in ring-cusp electron-bombardment ion thrusters. The plasma potential structures are insensitive to thruster throttling level with a minimum as low as 14 V measured at the DCA exit plane and increasing gradually in the axial direction. A sharp increase in plasma potential to the bulk discharge value of 26 to 28 volts, roughly 10 mm radially from DCA centerline, was observed. Plasma potential measurements indicate a low-potential plume structure that is roughly 20 mm in diameter emanating from the discharge cathode that may be attributed to a free-standing plasma double layer.
Radio technique for probing solar plasma during superior conjunction of Mariner 6 and 7 spacecraft