Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Machining Specific Fourier Power Spectrum Profiles into Plastics for High Energy Density Physics Experiments [Machining Specific Fourier Power Spectrum Profiles into Plastics for HEDP Experiments]

In this paper, the High Energy Density Physics program at Los Alamos National Laboratory (LANL) has had a multiyear campaign to verify the predictive capability of the interface evolution of shock propagation through different profiles machined into the face of a plastic package with an iodine-doped plastic center region. These experiments varied the machined surface from a simple sine wave to a double sine wave and finally to a multitude of different profiles with power spectrum ranges and shapes to verify LANL’s simulation capability. The MultiMode-A profiles had a band-pass flat region of the power spectrum, while the MultiMode-B profile had two band-pass flat regions. Another profile of interest was the 1-Peak profile, a band-pass concept with a spike to one side of the power spectrum. All these profiles were machined in flat and tilted orientations of 30 and 60 deg. Tailor-made machining profiles, supplied by experimental physicists, were compared to actual machined surfaces, and Fourier power spectra were compared to see the reproducibility of the machining process over the frequency ranges that physicists require.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fate in humans of the plasticizer, DI (2-ethylhexyl) phthalate, arising from transfusion of platelets stored in vinyl plastic bags

Platelet concentrates were shown to contain 18-38 mg/100 ml of a phthalate plasticizer (DEHP) which arose by migration from the vinyl plastic packs in which the plateletes were prepared and stored. Transfusion of these platelets into 6 adult patients with leukemia resulted in peak blood plasma levels of DEHP ranging from 0.34 - 0.83 mg/100 ml. The blood levels fell mono-exponentially with a mean rate of 2.83 percent per minute and a half-life of 28.0 minutes. Urine was assayed by a method that would measure unchanged DEHP as well as all phthalic acid-containing metabolities. In two patients, at most 60 and 90% of the infused dose, respectively, was excreted in the urine collected for 24 hours post-transfusion. These estimates, however, could be high due to the simultaneous excretion of DEHP remaining from previous transfusions or arising from uncontrolled environmental exposures.

Rubin, R. J.↗

Practical solution of plastic deformation problems in elastic-plastic range

A practical method for solving plastic deformation problems in the elastic-plastic range is presented. The method is one of successive approximations and is illustrated by four examples which include a flat plate with temperature distribution across the width, a thin shell with axial temperature distribution, a solid cylinder with radial temperature distribution, and a rotating disk with radial temperature distribution.

COLUMNS, TUBULAR↗

Design and Development of Thin Plastic Foil, Conical Approximation, High Through-out X-Ray Telescope: Light Weight, Thin Plastic Foil, X-Ray Telescopes

We present results from a program to develop an X-ray telescope made from thin plastic shells. Our initial results have been obtained from multi-shell cylindrical lenses that are used in a point-to-point configuration to image the small focal spot of a an X-ray tube on a microchannel plate detector. We describe the steps that led up to the present design and present data from the tests that have been used to identify the properties of the plastic material that make it a suitable X-ray reflector. We discuss two applications of our technology to X-ray missions that are designed to address some of the scientific priorities set forth in NASA's long term plans for high energy astrophysics. One mission will observe in the 1 - 10 keV band, the other will extend up to ca. 100 keV.

Schnopper, Herbert W.↗

Practical Solution of Plastic Deformation Problems in Elastic-Plastic Range

A practical method for solving plastic deformation problems in the elastic-plastic range is presented. The method is one of successive approximations and is illustrated by four examples which include a flat plate with temperature distribution across the width. a thin shell with axial temperature distribution, a solid cylinder with radial temperature distribution, and a rotating disk with radial temperature distribution.

Mendelson, A.↗

A comparison of plastic and visco-plastic constitutive models for accurate predictions in PM-HIP

Powder metallurgy hot isostatic pressing (PM-HIP) is an advanced manufacturing process that can efficiently produce near net shape parts with high material utilization and uniform microstructures. While the PM-HIP process is used frequently to produce small-scale components, its application to large-scale components is still limited due to inadequate understanding of its complex processes that cause unpredictable post-HIP shape distortions. A computational model can be a cost-effective alternative to exhaustive experimentation required to understand the PM-HIP process fully. Therefore, we present a comparison of plastic and visco-plastic models that are frequently used to model the PM-HIP process. We show that the predictions of powder densification behavior and shape distortions obtained from both the models are similar under most conditions and agree well with experimental observations.

Sarkar, Subrato [ORNL]↗

Characterization of wood plastic composites made from landfill-derived plastic and sawdust: Volatile compounds and olfactometric analysis

Graphical abstract: This work details the characterization of VOCs of WPC, produced from residual materials which would have landfills as current destination, and evaluates their odor profile. Highlights: ► More than 140 volatile compounds were identified in raw materials and WPC products. ► Markers were related to the thermal degradation, sawdust or coupling agents. ► WPC prototype showed a characteristic odor profile of burnt, sweet and wax-like. ► Aldehydes, carboxylic acids, ketones and phenols were odor descriptors of WPC. - Abstract: Application of wood plastic composites (WPCs) obtained from recycled materials initially intended for landfill is usually limited by their composition, mainly focused on release of volatile organic compounds (VOCs) which could affect quality or human safety. The study of the VOCs released by a material is a requirement for new composite materials. Characterization and quantification of VOCs of several WPC produced with low density polyethylene (LDPE) and polyethylene/ethylene vinyl acetate (PE/EVA) films and sawdust were carried out, in each stage of production, by solid phase microextraction in headspace mode (HS-SPME) and gas chromatography–mass spectrometry (GC–MS). An odor profile was also obtained by HS-SPME and GC–MS coupled with olfactometry analysis. More than 140 compounds were observed in the raw materials and WPC samples. Some quantified compounds were considered WPC markers such as furfural, 2-methoxyphenol, N-methylphthalimide and 2,4-di-tert-butylphenol. Hexanoic acid, acetic acid, 2-methoxyphenol, acetylfuran, diacetyl, and aldehydes were the most important odorants. None of the VOCs were found to affect human safety for use of the WPC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online Characterization of Mixed Plastic Waste Using Machine Learning and Mid-Infrared Spectroscopy

To recycle the mixed plastic wastes (MPW), it is important to obtain the compositional information online in real time. We present a sensing framework based on a convolutional neural network (CNN) and mid-infrared spectroscopy (MIR) for the rapid and accurate characterization of MPW. The MPW samples are placed on a moving platform to mimic the industrial environment. The MIR spectra are collected at the rate of 100 Hz, and the proposed CNN architecture can reach an overall prediction accuracy close to 100%. Therefore, the proposed method paves the way toward the online MPW characterization in industrial applications where high throughput is needed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The influence of hold time on the onset of plastic deformation in silicon

The transformation of diamond-cubic silicon to the metallic β-Sn phase is known to be “sluggish,” even when the critical pressure (∼11 GPa) for the transformation is reached. In this letter, we use nanoindentation to apply pressures to just above the critical threshold. In this regime, the sample displays purely elastic behavior at zero hold time. As the hold time at maximum load is increased up to 180 s, the percentage of indents that plastically deform also increase. Interestingly, the indents deform via one of two distinct processes: either via a phase transformation to a mixed bc8/r8-Si end phase, or by initiation of crystalline defects. Raman spectroscopy and cross-sectional transmission electron microscopy are used to show that the two deformation mechanisms are mutually exclusive under the indentation conditions presented here, and elastic modelling was utilized to propose a model for this mutually exclusive behavior. Hence, this behavior enhances the potential for application of the exotic bc8/r8-Si end phase.

36 MATERIALS SCIENCE↗

In situ friction and wear behavior of rubber materials incorporating various fillers and/or a plasticizer in high-pressure hydrogen

Polymers are used routinely for equipment and infrastructure in hydrogen vehicle refueling stations, but significant gaps remain in understanding their hydrogen compatibility. The tribological properties of these materials in a high-pressure hydrogen environment is important in preventing component failure and the need for frequent replacement. We present in situ tribological studies on model rubbers, which include common fillers and plasticizer, using an in situ tribometer developed previously. Results suggest a clear, yet complicated, combined effect of the high-pressure hydrogen and the additives on the tribological performance of the chosen materials, as compared to matching experiments performed in ambient air. We find that the additives improved wear resistance in EPDM but deteriorated that in NBR due to disparate additive-polymer interactions.

Kuang, Wenbin↗

Rapid atom-efficient polyolefin plastics hydrogenolysis mediated by a well-defined single-site electrophilic/cationic organo-zirconium catalyst

Polyolefins comprise a major fraction of single-use plastics, yet their catalytic deconstruction/recycling has proven challenging due to their inert saturated hydrocarbon connectivities. Here a very electrophilic, formally cationic earth-abundant single-site organozirconium catalyst chemisorbed on a highly Brønsted acidic sulfated alumina support and characterized by a broad array of experimental and theoretical techniques, is shown to mediate the rapid hydrogenolytic cleavage of molecular and macromolecular saturated hydrocarbons under mild conditions, with catalytic onset as low as 90 °C/0.5 atm H 2 with 0.02 mol% catalyst loading. For polyethylene, quantitative hydrogenolysis to light hydrocarbons proceeds within 48 min with an activity of > 4000 mol(CH 2 units)·mol(Zr) –1 ·h –1 at 200 °C/2 atm H 2 pressure. Under similar solventless conditions, polyethylene-co–1-octene, isotactic polypropylene, and a post-consumer food container cap are rapidly hydrogenolyzed to low molecular mass hydrocarbons. Regarding mechanism, theory and experiment identify a turnover-limiting C-C scission pathway involving ß-alkyl transfer rather than the more common σ-bond metathesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Average neutron time-of-flight instrument response function inferred from single D-T neutron events within a plastic scintillator

The apparent ion temperature and neutron-reaction history are important characteristics of a fusion plasma. Extracting these quantities from a measured neutron-time-of-flight signal requires accurate knowledge of the instrument response function (IRF). This paper describes a novel method for obtaining the IRF directly for single DT neutron interactions by utilizing n-alpha coincidence. The t(d,α)n nuclear reaction was produced at Sandia National Laboratories’ Ion Beam Laboratory using a 300 keV Cockcroft-Walton generator to accelerate a 2.5 μA beam of 175 keV D + ions into a stationary ErT 2 target. The average neutron IRF was calculated by taking a time-corrected average of individual neutron events within an EJ-228 plastic scintillator. The scintillator was coupled to two independent photo-multiplier tubes operated in the current mode: a Hamamatsu 5946 mod-5 and a Photek PMT240. Finally, the experimental setup and results will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗