Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES, FLAT - STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Simple Heat Transfer Model for Film Cooling Applications

This report describes the development of a simple engineering model for film cooling. This model is used to derive a relationship between local wall temperature variations and key cooling performance parameters like local heat transfer coefficients and film effectiveness. This relation and method new and different from previously published models. The scope of this report includes the derivation of regression model equations for a flat plate with and without film cooling. The model equation for a flat plate without film cooling can be used to estimate local heat transfer coefficients using surface temperatures measured from infrared thermography. The model equation for the flat plate with film cooling can be used to estimate film cooling effectiveness, $η_f$, and heat transfer augmentation from the film cooling jet(s).

42 ENGINEERING↗

Syracuse Univesity Test Report On Uptake Factor Resulting From A Dropped Storage Container - Phase II

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO 3 ) was selected in this study to represent relatively heavy powders (7.16 g/cm 3 specific gravity for WO 3 ). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in 3 (842.7 cm 3 ) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft 3 (24.1 m3). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours. A test procedure was developed and verified. A total of thirty two drop tests were performed, eight in Phase I and twenty four in Phase II, covering variations in dropping height (8 ft or 4 ft from the floor), room air movement (0.25-0.30 m/s or 0.10-0.15 m/s near the ceiling), landing scenario (on a flat plate or a block), and lid condition (¼” lid hole or no lid). There were ten tests with flat plate and ¼” lid hole, ten tests with flat plate no lid and twelve tests with block no lid.

42 ENGINEERING↗

Influence of Heave Plate Topology on Reaction Force

In this study, we explore the role of heave plate topology on fluid reaction forces using three, representative shapes: a hexagonal flat plate, a hexagonal conic with an open top, and the same with a closed top that encloses a fluid mass. We force each test article sinusoidally in a quiescent tank and decompose the reaction force using forms of the Morison equation for phase-invariant and phase-dependent parameterizations. We find that a flat plate generates 5.3 % more fluid reaction force than the open conic topology, and 21.4% more than the enclosed conic. Asymmetric topologies generate asymmetric reaction forces, but the magnitude of asymmetry is limited by nearly symmetric fluid inertia forces, which dominate over drag for these test articles. Additionally, we observe asymmetric vortex dynamics for the flat plate when the Keulegan-Carpenter number is between 1 and 2, accompanied by a shift in the phase of the peak force by of the oscillation period. As a consequence of this shift, the hydrodynamic coefficients estimated from the phase-dependent Morison equation decomposition are asymmetric, suggesting that phase-dependent representations may not provide physical insight in some hydrodynamic regimes.

added mass↗

ITER cold VDEs in the limit of perfectly conducting walls

Recently, it has been shown that a vertical displacement event (VDE) can occur in ITER even when the walls are perfect conductors, as a consequence of the current quench (CQ) [A. H. Boozer, Phys. Plasmas 26, 114501 (2019)]. We used the extended-MHD code M3D-C1 with an ITER-like equilibrium and induced a CQ to explore cold VDEs in the limit of perfectly conducting walls, using different wall geometries. In the case of a rectangular first wall with the side walls far away from the plasma, we obtained very good agreement with the analytical model developed by Boozer that considers a top/bottom flat-plates wall. We show that the solution in which the plasma remains at the initial equilibrium position is improved when bringing the side walls closer to the plasma. When approximating the ITER first wall as a perfect conductor, the plasma remains stable at the initial equilibrium position far beyond the value predicted by the flat-plates wall limit. When considering an opposite limit in which only the inner shell of the ITER vacuum vessel acts as a perfect conductor, the plasma is displaced during the CQ, but the edge safety factor remains above 2 longer in the current decay compared to the flat-plates wall limit. In all the simulated cases, the VDE is found to be strongly dependent on the plasma current, in agreement with a similar finding in the flat-plates wall limit, showing an important difference with hot VDEs in which the CQ is not a necessary condition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Evaluation of Heat Transfer in a High Temperature High Pressure Test Facility

Performance of film cooling holes is generally evaluated near ambient conditions, so scaling the film cooling performance from ambient to engine conditions is important. These performance metrics can be reported in terms of net heat flux reduction, heat transfer enhancement, and effectiveness. There are several challenges and penalties in conducting experiments on a real engine or even on a stationary flat plate test article at near engine conditions. In this study, an experimental methodology capable of delivering film cooling performance for the experiments conducted in the high-temperature high-pressure test facility at NETL will be explored. More specifically, this study focuses on various challenges that are present and how these concerns are addressed to evaluate the heat transfer coefficient on the test article. Steady state experiments were conducted on a flat plate test article whose surface temperature distribution was obtained using an IR camera calibrated with a combination of bench top experiments and in-situ calibrations based on embedded thermocouple measurements. A detailed radiation analysis is conducted to enable differentiation of heat transfer by convection from heat transfer by radiation. The estimated surface heat flux and heat transfer coefficient were found to be higher than the one obtained from flat plate correlation.

Ramesh, Sridharan↗

Next Generation Photovoltaic Technologies For High-Performance Remote Power Generation (Final Report)

A unique, micro-scale architecture is proposed to create a novel hybrid concentrated photovoltaic system. Micro-scale (sub-millimeter wide), multi-junction cells are attached to a large-area silicon cell backplane (several inches wide) that can optimally collect both direct and diffuse light. By using multi- junction III-V cells, we can get the highest possible efficiency of the direct light input. In addition, by collecting the diffuse light in the large-area silicon cell, we can produce power on cloudy days when the concentrating cells would have minimal output. Through the use of micro-scale cells and lenses, the overall assembly will provide higher efficiency than conventional concentrators and flat plates, while keeping the form factor of a flat plate module. This report describes the hybrid concept, the design of a prototype, including the PV cells and optics, and the experimental results.

14 SOLAR ENERGY↗

Enhancing the quality of radiographic images acquired with point-like gamma-ray sources through correction of the beam divergence and attenuation

Radiographic images acquired with point-like gamma-ray sources exhibit a desirable low penumbra effects specially when positioned far away from the set object-detector. Such an arrangement frequently is not affordable due to the limited flux provided by a distant source. A closer source, however, has two main drawbacks, namely the degradation of the spatial resolution - as actual sources are only approximately punctual - and the non-homogeneity of the beam hitting the detector, which creates a false attenuation map of the object being inspected. This non-homogeneity is caused by the beam divergence itself and by the different thicknesses traversed the beam even if the object were an homogeneous flat plate. In this work, radiographic images of objects with different geometries, such as flat plates and pipes have undergone a correction of beam divergence and attenuation addressing the experimental verification of the capability and soundness of an algorithm formerly developed to generate and process synthetic images. The impact of other parameters, including source-detector gap, attenuation coefficient, ratio defective-to-main hull thickness and counting statistics have been assessed for specifically tailored test-objects aiming at the evaluation of the ability of the proposed method to deal with different boundary conditions. All experiments have been carried out with an X-ray sensitive Imaging Plate and reactor-produced {sup 198}Au and {sup 165}Dy sources. The results have been compared with other technique showing a better capability to correct the attenuation map of inspected objects unveiling their inner structure otherwise concealed by the poor contrast caused by the beam divergence and attenuation, in particular for those regions far apart from the vertical of the source.

07 ISOTOPE AND RADIATION SOURCES↗

Performance evaluation of a low-temperature solar Rankine cycle system utilizing R245fa

A low-temperature solar Rankine system utilizing R245fa as the working fluid is proposed and an experimental system is designed, constructed and tested. Both the evacuated solar collectors and the flat plate solar collectors are used in the experimental system; meanwhile, a rolling-piston R245fa expander is also mounted in the system. The new designed R245fa expander works stably in the experiment, with an average expansion power output of 1.73 kW and an average isentropic efficiency of 45.2%. The overall power generation efficiency estimated is 4.2%, when the evacuated solar collector is utilized in the system, and with the condition of flat plate solar collector, it is about 3.2%. The experimental results show that using R245fa as working fluid in the low-temperature solar power Rankine cycle system is feasible and the performance is acceptable. (author)

14 SOLAR ENERGY↗

The effects of leaf size and microroughness on the branch-scale collection efficiency of ultrafine particles

In this study, wind tunnel experiments were performed to explore how leaf size and leaf microroughness impact the collection efficiency of ultrafine particles (UFP) at the branch scale. A porous media model previously used to characterize UFP deposition onto conifers (Pinus taeda and Juniperus chinensis) was employed to interpret these wind tunnel measurements for four different broadleaf species (Ilex cornuta, Quercus alba, Magnolia grandiflora, and Lonicera fragrantissima) and three wind speed (0.3–0.9 ms -1 ) conditions. Among the four broadleaf species considered, Ilex cornuta with its partially folded shape and sharp edges was the most efficient at collecting UFP followed by the other three flat-shaped broadleaf species. The findings here suggest that a connection must exist between UFP collection and leaf dimension and roughness. This connection is shown to be primarily due to the thickness of a quasi-laminar boundary layer pinned to the leaf surface assuming the flow over a leaf resembles that of a flat plate. A scaling analysis that utilizes a three-sublayer depositional model for a flat plate of finite size and roughness embedded within the quasi-laminar boundary layer illustrates these connections. The analysis shows that a longer leaf dimension allows for thicker quasi-laminar boundary layers to develop. A thicker quasi-laminar boundary layer depth in turn increases the overall resistance to UFP deposition due to an increase in the diffusional path length thereby reducing the leaf-scale UFP collection efficiency. Finally, it is suggested that the effects of leaf microroughness are less relevant to the UFP collection efficiency than are the leaf dimensions for the four broadleaf species explored here.

54 ENVIRONMENTAL SCIENCES↗

Numerical analysis of three complex three-dimensional shock wave / turbulent boundary layer interaction flows

A set of Reynolds-averaged Navier-Stokes (RANS) computations with turbulence closure provided by the Spalart-Allmaras (SA) model have been carried out for prediction of shock-induced three-dimensional (3D) turbulent separated flows. The experimental data for different aerodynamic test configurations have been used for assessing credibility of the numerical method employed. Particularly, shock wave / turbulent boundary layer interactions (SWTBLI) in the vicinity of an asymmetric sharp double-fin (DF) with different (7° and 11°) deflection angles mounted on a flat plate and two conically sharp cylindrical bodies at varying interbody distances and nose cone angles 60° and 40° mounted over a flat plate at freestream Mach number 4, as well as a transonic fan stage operating in the near-stall regime are considered. The gas dynamic structure and topology of 3D separated flows, surface flow patterns, and pressure distributions as well as body aerodynamic force prediction are analyzed. A transonic fan stage operating in the near-stall regime and a possibility of applying flow control is investigated. High Performance Computing was employed to make high resolution computations of these flows possible, and advanced 3D visualization techniques were employed in order to improve understanding of the separating flow phenomena.

42 ENGINEERING↗

A Light Sail Inspired Model to Harness Casimir Forces for Propellantless Propulsion

The model used to calculate Casimir forces for variously shaped conducting plates in this paper assumes the vacuum energy pervades all space and that photons randomly pop into and out of existence. While they exist, they possess energy and momentum that can be transferred by reflection as in a light sail. Quantum mechanics in the model is entirely bound up in the Casimir equation of force per unit area. This model is compared with two different experiments: that of Chen and Mohideen demonstrating lateral Casimir forces for sinusoidally corrugated spherical and flat plates and Lamoreaux demonstrating normal Casimir forces between a conducting sphere and flat plate. The calculated forces using this model were compared to the forces obtained in these experiments as well as with calculations using the proximity force approximation. In both cases the results (when compared to the actual plates measured and calculated using non-corrected equations) were less than a few parts per thousand different for the range of separation distances used. When the model was used to calculate forces on the opposite plates, different force magnitudes were obtained seemingly indicating prospects for propellentless propulsion but requiring skeptical verification.

42 ENGINEERING↗

High Flux Metallic Membranes for Hydrogen Recovery and Membrane Reactors

We made and tested over 250 new alloys for use as lower cost, higher flux hydrogen extraction membrane materials. Most of these were intermetallic, or contained significant intermetallic content, particularly based on B2 alloy compositions with at least one refractory component; B2 intermetallics resemble BCC alloys, in structure, but the atoms have relatively fixed positions, with one atom at the corners of the cube, the other at the centers. The target materals we were looking for would contain little or no expensive elements, no strongly toxic or radioactive elements, would have high flux to hydrogen, while being fabricable, brazable, and relatively immune to hydrogen embrittlement and corrosion in operation. The best combination of properties of the membrane materials we developed was, in my opinion, a Pd-coated membrane consisting of V -9 atomic % Pd. This material was relatively cheap, had 5 times the flux of Pd under the same pressure differential, was reasonably easy to fabricate and braze, and not bad in terms of embrittlement. Based on all these factors we project, about 1/3 the cost of Pd, on an area basis for a membrane designed to last 20 years, or 1/15 the cost on a flux basis. Alternatives to this membrane replaced significant fractions of the Pd with Ni and or Co. The cost for these membranes was lower, but so was the flux. We produced successful brazed products from the membrane materials, and made them into flat sheets. We tested, unsuccessfully, several means of fabricating thematerials into tubes, and eventually built a membrane reactor using a new, flat-plate design: a disc and doughnut arrangement, a design that seems well- suited to clean hydrogen production from coal. The membranes and reactor were tested successfully at Western Research. A larger equipment company (Chart Industries) produced similar results using a different flat-plate reactor design. Cost projections of the membrane are shown to be attractive.

08 HYDROGEN↗

Theoretical modeling of a bottom-raised oscillating surge wave energy converter structural loadings and power performances

Here, this study presents theoretical formulations to evaluate the fundamental parameters and performance characteristics of a bottom-raised oscillating surge wave energy converter (OSWEC) device. Employing a flat plate assumption and potential flow formulation in elliptical coordinates, closed-form equations for the added mass, radiation damping, and excitation forces/torques in the relevant pitch-pitch and surge-pitch directions of motion are developed and used to calculate the system's response amplitude operator and the forces and moments acting on the foundation. The model is benchmarked against numerical simulations using WAMIT and WEC-Sim, showcasing excellent agreement. The sensitivity of plate thickness on the analytical hydrodynamic solutions is investigated over several thickness-to-width ratios ranging from 1:80 to 1:10. The results show that as the thickness of the benchmark OSWEC increases, the deviation of the analytical hydrodynamic coefficients from the numerical solutions grows from 3% to 25%. Differences in the excitation forces and torques, however, are contained within 12%. While the flat plate assumption is a limitation of the proposed analytical model, the error is within a reasonable margin for use in the design space exploration phase before a higher-fidelity (and thus more computationally expensive) model is employed. A parametric study demonstrates the ability of the analytical model to quickly sweep over a domain of OSWEC dimensions, illustrating the analytical model's utility in the early phases of design.

13 HYDRO ENERGY↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Expanded verification and validation studies of hypersonic aerodynamics with multiple physics-fidelity models

Hypersonic aerothermodynamics is an important domain of modern multiphysics simulation. The Multi-Fidelity Toolkit is a simulation tool being developed at Sandia National Laboratories to predict aerodynamic properties for compressible flows from a range of physics fidelities and computational speeds. These models include the Reynolds-averaged Navier–Stokes (RANS) equations, the Euler equations with momentum-energy integral technique (MEIT), and modified Newtonian aerodynamics with flat-plate boundary layer (MNA+FPBL) equations, and they can be invoked independently or coupled with hierarchical Kriging to interpolate between high-fidelity simulations using lower-fidelity data. However, as with any new simulation capability, verification and validation are necessary to gather credibility evidence. This work describes formal code- and solution-verification activities, as well as model validation with uncertainty considerations. Code verification activities on the MNA+FPBL model build on previous work by focusing on the viscous portion of the model. Viscous quantities of interest are compared against those from an analytical solution for flat-plate, inclined-plate, and cone geometries. The code verification methodology for the MEIT model is also presented. Test setup and results of code verification tests on the laminar and turbulent models within MEIT are shown. Solution-verification activities include grid-refinement studies on simulations that model the HIFiRE-1 wind tunnel experiments. These experiments are used for validation of all model fidelities. A thorough validation comparison with prediction error and uncertainty is also presented. Three additional HIFiRE-1 experimental runs are simulated in this study, and the solution verification and validation work examines the effects of the associated parameter changes on model performance. Finally, a study is presented that compares the computational costs and fidelities from each of the different models.

42 ENGINEERING↗

A New Model to Determine Installed System Cost and LCOE for ARPA-E's MOSAIC Micro-Concentrator PV Program: Preprint

The US Department of Energy's Advanced Research Projects Agency-Energy (ARPA-E) started a three-year program in December 2015 called Microscale Optimized Solar-cell Arrays with Integrated Concentration (MOSAIC). It consists of 11 teams from across the United States. Its goal is to have project teams leverage expertise from conventional flat-plate photovoltaic (PV) system configuration and concentrated photovoltaic (CPV) module technology to produce a new class of modules for residential, commercial, and utility-scale markets. The intent is to increase performance and facilitate cost-effective deployment of solar power systems across a wide range of geographical locations in part by concentrating both direct and diffuse components of the sun's irradiance. This paper describes a collaboration of ARPA-E and the National Renewable Energy Laboratory (NREL) to develop a bottom-up system cost model for MOSAIC research teams. The model includes an estimate of regional, all-in, CPV installed cost, and levelized cost of energy (LCOE) by using customized inputs parameters, such as module efficiency, cost, and physical dimensions. This techno-economic cost model can help researchers analyze tradeoffs among different design parameters and then prioritize their distinct research opportunities. Moreover, it establishes a standardized cost benchmarking for MOSAIC micro-CPV systems and a normalized comparison against traditional CPV and today's highly competitive flat-plate PV systems. The model is a valuable design tool within the program, helping validate the various technical approaches and compare future deployed system competitiveness versus incumbent technologies in the PV industry.

14 SOLAR ENERGY↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗