At least 73 records · Page 4

Performance of CsI:Tl Cyrstal with a Spectrum Matching Photomultiplier Tube

This report documents an effort to improve the energy resolution for a thallium doped cesium iodide (CsI:T1) scintillator paired with a spectrum matching photomultiplier tube (PMT). A comparison of the differences in the pulse height spectra from thallium doped (CsI:T1) and sodium doped (CsI:Na) single crystals with PMTs of different spectrum responses was performed. Results show that energy resolution of the detector only improves 0.5% at room temperature when these scintillators are coupled with a spectrum matching PMT. Based on a spectrum matching PMT, the best results for energy resolution are 7.39% and 7.88% for CsI:T1 and CsI:Na scintillators, respectively. The improvement is primarily attributed to the increase of photon statistics from the increase of photons (N) being detected in the spectrum matching PMT. Other factors, such as optical quantum yield and non-proportionality of the CsI:T1 and CsI:Na crystals, that can affect the energy resolution were also studied and reported. The results indicate that although the use of a spectrum matching PMT enhances the photon statistics, it also exacerbates the nonproportionality response. Consequently, a promised improvement on energy resolution due solely to photon statistics was not fully realized.

36 MATERIALS SCIENCE↗

Steps toward FNCL Cell Replacement (FY2021 Mid-Year Annual Report)

Evaluate compact replacement cells for the Fast Neutron Collar (FNCL). The current cells are 4x4x4 in 3 of EJ-309 instrumented with 8” tall PMTs, and the replacements are 4x4x3 in 3 cells instrumented with 1” tall SiPM arrays. The replacement cell materials are stilbene (organic crystal), EJ-309 (liquid scintillator), and EJ-299-33M (PSD-capable plastic).

42 ENGINEERING↗

Development of a New Neutron Electric Dipole Moment Experiment at LANL [Slides]

Conclusion: New timing filter amps and power supplies for the PMTs have been procured. The second switcher is built and will be tested with UCN soon. The second simultaneous spin analyzer is being built at Indiana University and will be tested this year. We plan to start taking production data from next year

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report on the Phase II Physics Proposal for T-1063: The Accelerator Neutrino Neutron Interaction Experiment (ANNIE)

The goal of ANNIE is to make the first detailed measurement of the number of neutrons produced by neutrinos interacting with nuclei. This measurement is important for understanding the results of previous and planned neutrino experiments, as neutrons carry away energy from the neutrino interactions that must be accounted for in determining the energy and neutrino type. This effort is also focused on using a new photodetector technology and key target material enhancements to enable advanced water-based neutrino detectors. The ANNIE detector has been installed in the Booster Neutrino Beam at Fermilab, which provides a pulsed source of neutrinos in the energy range of 300-1200 MeV, which is relevant for the next generation of neutrino experiments. In 2017-2018 measurements of the neutron background in this beam were made with a partially-instrumented ANNIE detector. These measurements guided our design of the upgraded detector now built. The upgrade has been realized by adding Large Area Picosecond Photodetectors (LAPPDs) for the first time, more conventional photomultiplier tubes (PMTs), as well as adding electronics channels to the existing data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \approx 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementation of a Time-domain Cosmic-Ray-Muon Tagger for the NEXUS Low-background Cryogenic Facility

Quantifying the effects of radiation on the operation of qubits both as quantum information systems as well as particle detectors has emerged as a pressing issue in quantum science in recent years. We present an overview of the design, operation, and deployment of a 90-$\mathrm{in}^2$ three-panel muon detector for use in the NEXUS experimental facility at Fermilab to temporally isolate correlated errors in qubits and determine if they possess an astrophysical origin. Constructed with three scintillator-attached PMTs read out with NIM modules in a triply-coincident logic scheme, we measure a surface-level muon luminosity of 9.7425 muons per second---consistent with an average surface-level cosmic-ray flux of approximately one muon per square centimeter per minute. Integrating the NIM modules with an MCC 128 DAQ HAT and Raspberry Pi, a Python script records exactly when a muon struck the detector and writes a timestamp to a log file for follow-up cross referencing. This experiment will broadly contribute to further studies aimed at understanding the source and mitigation of information loss in qubits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing Neutrino Event Simulation through Overlays at the ICARUS Experiment on the Short-Baseline Neutrino Program

In the pursuit of precise neutrino event simulation, the ICARUS experiment within the Short-Baseline Neutrino (SBN) program at Fermilab uses an overlay technique to closely align simulations with experimental data. This technique consists of taking signals from data from each of the each of the three subsystems (TPC, PMT, CRT) and overlaying a simulated neutrino interaction onto the event. The overlay procedure includes superimposing simulated waveforms from neutrino interactions from both Time Projection Chambers (TPC) and Photomultiplier Tubes (PMTs) onto their respective data counterparts. Furthermore, the Cosmic Ray Tagger (CRT) hits from both data and simulations are combined to form the overlay event. By combining signals in this manner, we can obtain a data-driven modeling of cosmic backgrounds as well as the detector response enabling a more precise handling of noise sources when using neutrino simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data vs. MC Comparison of Light Signal from Cosmic Rays in the ICARUS Detectors

Currently, the ICARUS-T600 liquid argon TPC is collecting data exposed to Booster Neutrino and Numi off-axis beams within the SBN program at Fermilab. A light detection system, based on PMTs deployed behind the TPC wire chambers, is in place to detect vacuum ultraviolet photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its operations at shallow depths, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates. This contribution will primarily focus on the comparative study (data vs. MC) of light signal of cosmic muons to validate the light emulation.

43 PARTICLE ACCELERATORS↗

Demonstration of <2 ns timing resolution for neutrino interaction in the MicroBooNE detector

The MicroBooNE detector, located in the Booster Neutrino Beamline (BNB) at Fermilab, collected data from 2015 to 2021. MicroBooNE’s Liquid Argon Time Projection Chamber is accompanied by a Photon Detection System consisting of 32 PMTs used to measure the argon scintillation light and determine the timing of the neutrino interactions. This work employs improved analysis techniques combining light signals and reconstructed tracks achieving neutrino interaction timing resolution <2 ns. The result obtained allows MicroBooNE to access the 2 ns neutrino pulse structure of the BNB for the first time. The timing resolution achieved enables significant enhancement of cosmic background rejection for all neutrino analyses. Furthermore, the ns timing resolution opens the door for searching new long-lived-particles (e.g. Heavy Neutral Leptons, Higgs Portal Scalars) in MicroBooNE, as well in future large LArTPC experiments, namely SBN and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Yield Calibration in MicroBooNE

The MicroBooNE detector is a Liquid Argon Time Projection Chamber (LArTPC) located along the Booster Neutrino Beam (BNB) at Fermilab. Its primary physics goal is to contribute to addressing the elusive short-baseline MiniBooNE low energy excess. MicroBooNE records and utilises both the ionisation charge and scintillation light produced inside the TPC to select and reconstruct neutrino interactions. The scintillation light collected using a plane of PhotoMultiplier Tubes (PMTs) is also used for accurate event timing and cosmic muon rejection with the latter being an important background for detectors, such as MicroBooNE, located on the surface. A good understanding of light modeling and its related systematic uncertainties is crucial to evaluate their impact on physics analyses. The experience acquired from MicroBooNE regarding how the stability of the scintillation light behaves and evolves during the 5 years of the primary physics run will be discussed as well as the calibration method used. This experience will help with understanding the physics of scintillation light in LArTPCs for the future long-running Short-Baseline Neutrino (SBN) and Deep Underground Neutrino Experiment (DUNE) programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Light Yield with Isolated Protons in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are precision detectors used extensively in neutrino physics. The MicroBooNE experiment at Fermilab is one of the experiments employing this technique and has collected 5 years of data from 2015-2021. The primary signal in LArTPCs is ionisation, but argon also emits large quantities of scintillation light, which can be used for calorimetry, timing and background rejection. Prompt scintillation light in MicroBooNE is recorded with an array of 32 PhotoMultiplier Tubes (PMTs). To enable the full use of scintillation light in the experiment, it is important to characterize the efficiency of light collection in the detector, i.e. the light yield. We present a new method of measuring the light yield using isolated proton interactions, which enables a position-dependent light yield measurement to map the response of the detector across its volume. This method can be used to calibrate the light response in large-scale LArTPC detectors as well as to test assumptions used in simulating scintillation light.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and Timing Performance of the Light Detection System in the ICARUS Detector

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. It aims to investigate the possible existence of sterile neutrinos with $\Delta m^2 \approx \SI{1}{eV^2}$ using the Booster Neutrino Beam (BNB) and explore physics beyond the Standard Model with the Neutrinos at the Main Injector (NuMI) beam. The ICARUS light detection system, comprising 360 TPB-coated large-area Photo-Multiplier Tubes (PMTs), is crucial for triggering and event reconstruction. Due to its shallow installation, the detector is exposed to a high flux of cosmic rays, necessitating precise timing to reject background events and align neutrino interactions with the beam time profile. This talk will detail the timing inter-calibration procedures for the ICARUS light detection system, which achieve sub-nanosecond resolution. Additionally, the performance of the system in reconstructing the timing of neutrino interactions from the BNB and NuMI beams will be discussed. The results highlight the effectiveness of the ICARUS light detection system in enhancing the detector's capability for precise and reliable neutrino selection.

43 PARTICLE ACCELERATORS↗

Characterization of High-Temperature SiPM Noise

Introduction • Background: Silicon photomultipliers (SiPMs) are compact, low-power, and high-efficiency detectors that are increasingly used in radiation detection applications like medical imaging and nuclear safeguards. The have advantages of PMTs because they are smaller, operate at lower voltages, and offer high photon detection efficiency. • Challenges: SiPMs suffer from increased dark count rate (DCR) and optical crosstalk (OCT), which degrades performance. • Purpose of study: This study compares the Advansid ASD-NUV3S-P-40, Broadcom AFBR-S4K33C0147L, and Onsemi MicroFJ-30035-TSVTR under four different temperatures to compare their performance in harsh environments.

Fritchie, Jacob↗

Neutron Identification Capabilities in MicroBooNE Through the Application of Machine Learning with Blips

Neutrinos (ν) are subatomic particles first observed in 1956 by LANL physicists Clyde Cowan and Frederick Reines but first theorized by Wolfgang Pauli in 1930. Neutrinos are the least massive known particle and are classified as leptons with 3 flavors corresponding to their leptonic counterparts (electron, muon, and tau). We know that they are abundant, 65 billion neutrinos travel through your fingertip every second, and elusive, a single neutrino could fly through a lightyear of lead without interacting at all. Though, there is much still unknown and a better characterization of these “ghostly” particles can give us clues as to the matter/anti-matter asymmetry in the early universe and possible glimpses into new physics. To measure a particle that is extremely light and rarely interacting, physicists have developed an extremely sensitive detector known as a Liquid Argon Time Projection Chamber (LArTPC). The fiducial volume (or TPC) is bombarded with neutrinos, some of which interact with argon (Ar) atoms to produce particles that in turn excite and ionize the Ar. The products of these are free electrons which then drift through the TPC’s applied magnetic field towards a multi-plane wire readout system. The electrons’ charge is collected at this anode and the light from the initial interactions is collected by photomultiplier tubes (PMTs). In conjunction, these mechanisms allow LArTPCs to achieve millimeter spatial resolution and sub-MeV energy thresholds. The detector of interest in this study is the MicroBooNE Experiment at Fermilab. MicroBooNE is an above ground LArTPC with dimensions of approximately 10m × 2.5m × 2.3m, about the size of a school bus. Its purpose is to study neutrinos, so to improve rates of measured ν interactions, the detector is squarely in the path of the Booster Neutrino Beam (BNB) at Fermilab. A major challenge in neutrino studies is energy reconstruction, much of the neutrino’s original energy is lost in interactions that the detector is not sensitive to, often due to low-energy products. The initial goal of this analysis was to better identify neutrons, the main source of poor energy reconstruction in neutrino events. Because neutrons are neutral particles, like neutrinos, we can only directly measure the products of their interactions in LArTPCs. Most of these products are low-energy signals and while each one contributes a negligible amount of energy, collectively these signals make up most of the lost energy in each neutrino event. We define these signals as blips; point-like, isolated depositions of charge in the detector. Blips have MeV-scale energies and are the size of a single hit (charge deposition) or a cluster of a few hits on at least two wire planes. Blips are the principal detector features used to study low-energy physics; thus, they are the key to unlocking information not only about neutrons but gamma photons, supernova and solar neutrinos as well as helping us better identify certain particles. Therefore, this analysis strives to use blips for improved neutron identification (ID) and characterization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geant4 Simulations and Experimental Results for the Pacific-Ocean Neutrino Experiment (P-ONE)

The Pacific-Ocean Neutrino Experiment (P-ONE) is an upcoming large-volume neutrino telescope planned to be built off the coast of Vancouver Island, Canada. It aims to detect high-energy neutrinos via the Cherenkov radiation produced in water by secondary particles born from high-energy neutrino interactions. Its first set of detectors is planned to be commissioned this year. However, since the telescope is still in its early stages of development, many tests and simulations must still be run to characterize the efficacy of the detectors. One necessary simulation must be devoted towards examining whether the polarization of the incoming Cherenkov light impacts the strength of the signals by the PMTs, and it must be supported by experimental data. In this report, I detail what I have completed during my SULI internship at the Los Alamos National Lab (LANL); I present the preliminary results of a Geant4 polarization simulation as well as preliminary laboratory measurements that will later be used to inform the future P-ONE design.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tagging Cosmic Ray Background in the Icarus Detector

ICARUS T-600 will be the Far Detector of the upcoming SBN program, for which it will leverage a ∼ 1ns response and a high resolution for neutrino event reconstruction. ICARUS will respond to the challenge of the cosmic flux at the surface thanks to its Cosmic Ray Tagging (CRT) system. The work conducted during the Summer Students at Fermilab program contributed to the calibration activities that are ongoing in view of the second physics run in late 2022: the timing of CRT and PMT signals was analysed, highlighting the need for corrections to the PMTs. The timing delay for the global trigger signal for a section of the side CRT. The possibility of calibrating the light yield of the side CRTs with run data was finally explored.

47 OTHER INSTRUMENTATION↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗