Search NASA⌕ Search

SEARCH · Search NASA

Results for “POLLUTION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Role of Monitoring in Controlling Water Pollution

The purpose of this paper is to provide an overview of trends in the national water pollution control effort and to describe the role of monitoring in that effort, particularly in relation to the responsibilities of the Environmental Protection Agency (EPA). I hope the paper will serve as a useful framework for the more specific discussions of monitoring technology to follow.

Hirsch, Allan↗

Development of a standard capture efficiency test method for residential kitchen ventilation

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality standards. However, airflow alone does not show how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood indoor air quality performance is capture efficiency -- the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. The current article summarizes the development of a range hood capture efficiency test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Standard Test Method for Reducing the Uncertainties in Measuring the Capture Efficiency of Range Hoods

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality (IAQ) standards. However, air flow alone does not tell us how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood IAQ performance is capture efficiency (CE)—the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. This paper summarizes the development of a range hood CE test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variable Streamflow Contributions in Nested Subwatersheds of a US Midwestern Urban Watershed

Quantification of runoff is critical to estimate and control water pollution in urban regions, but variation in impervious area and land-use type can complicate the quantification of runoff. We quantified the streamflow contributions of subwatersheds and the historical changes in streamflow in a flood prone urbanizing watershed in US Midwest to guide the establishment of a future pollution-control plan. Streamflow data from five nested hydrological stations enabled accurate estimations of streamflow contribution from five subwatersheds with variable impervious areas (from 0.5% to 26.6%). We corrected the impact of Missouri river backwatering at the most downstream station by comparing its streamflow with an upstream station using double-mass analysis combined with Bernaola-Galvan Heuristic Segmentation approach. We also compared the streamflow of the urbanizing watershed with seven surrounding rural watersheds to estimate the cumulative impact of urbanization on the streamflow regime. The two most urbanized subwatersheds contributed >365 mm streamflow in 2012 with 657 mm precipitation, which was more than fourfold greater than the two least urbanized subwatersheds. Runoff occurred almost exclusively over the most urbanized subwatersheds during the dry period. The frequent floods occurred and the same amount of precipitation produced ~100 mm more streamflow in 2008–2014 than 1967–1980 in the urbanizing watershed; such phenomena did not occur in surrounding rural watersheds. Our approaches provide comprehensive information for planning on runoff control and pollutant reduction in urban watersheds.

54 ENVIRONMENTAL SCIENCES↗

The economic impact of remote sensing data as the source of nonpoint pollution monitoring and control

Nonpoint pollution of streams with sediment as a result of runoff from alternative uses of land has become a socially unacceptable product of economic activity. This report describes a research approach to economically achieve correction of the nonpoint pollution problem. The research approach integrates the economic model with those data which may be obtainable from remotely sensed sources. The economic problem involves measurement of the direct benefits and costs associated with the changes in land management activities necessary to reduce the level of nonpoint pollution. Remotely sensed data from ERTS-1 may provide some of the information required for the economic model which indicates efficient solutions to the nonpoint pollution problem. Three classes of data (i.e., soil categories, vegetative cover, and water turbidity) have the potential to be measured by ERTS-1 systems. There is substantial research which indicates the ability of ERTS-1 to measure these classes of data under selected conditions.

Miller, W. L.↗

The Net Climate Impact of Coal-Fired Power Plant Emissions

Coal-fired power plants influence climate via both the emission of long-lived carbon dioxide (CO2) and short-lived ozone and aerosol precursors. Using a climate model, we perform the first study of the spatial and temporal pattern of radiative forcing specifically for coal plant emissions. Without substantial pollution controls, we find that near-term net global mean climate forcing is negative due to the well-known aerosol masking of the effects of CO2. Imposition of pollution controls on sulfur dioxide and nitrogen oxides leads to a rapid realization of the full positive forcing from CO2, however. Long-term global mean forcing from stable (constant) emissions is positive regardless of pollution controls. Emissions from coal-fired power plants until 1970, including roughly 1/3 of total anthropogenic CO2 emissions, likely contributed little net global mean climate forcing during that period though they may have induce weak Northern Hemisphere mid-latitude (NHml) cooling. After that time many areas imposed pollution controls or switched to low sulfur coal. Hence forcing due to emissions from 1970 to 2000 and CO2 emitted previously was strongly positive and contributed to rapid global and especially NHml warming. Most recently, new construction in China and India has increased rapidly with minimal application of pollution controls. Continuation of this trend would add negative near-term global mean climate forcing but severely degrade air quality. Conversely, following the Western and Japanese pattern of imposing air quality pollution controls at a later time could accelerate future warming rates, especially at NHmls. More broadly, our results indicate that due to spatial and temporal inhomogeneities in forcing, climate impacts of multi-pollutant emissions can vary strongly from region to region and can include substantial effects on maximum rate-of-change, neither of which are captured by commonly used global metrics. The method we introduce here to estimate regional temperature responses may provide additional insight.

Shindell, D.↗

Twenty-Five Years of Ecological Recovery of East Fork Poplar Creek: Review of Environmental Problems and Remedial Actions

In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Department of Energy s Y-12 National Security Complex (Y-12 Complex) in Oak Ridge, Tennessee, USA, allowing discharge of effluents to East Fork Poplar Creek (EFPC). The effluents ranged from large volumes of chlorinated oncethrough cooling water and cooling tower blow-down to smaller discharges of treated and untreated process wastewaters, which contained a mixture of heavy metals, organics, and nutrients, especially nitrates. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to meet two major objectives: demonstrate that the established effluent limitations were protecting the classified uses of EFPC, and document the ecological effects resulting from implementing a Water Pollution Control Program at the Y-12 Complex. The second objective is the primary focus of the other papers in this special series. This paper provides a history of pollution and the remedial actions that were implemented; describes the geographic setting of the study area; and characterizes the physicochemical attributes of the sampling sites, including changes in stream flow and temperature that occurred during implementation of the BMAP. Most of the actions taken under the Water Pollution Control Program were completed between 1986 and 1998, with as many as four years elapsing between some of the most significant actions. The Water Pollution Control Program included constructing nine new wastewater treatment facilities and implementation of several other pollution-reducing measures, such as a best management practices plan; area-source pollution control management; and various spill-prevention projects. Many of the major actions had readily discernable effects on the chemical and physical conditions of EFPC. As controls on effluents entering the stream were implemented, pollutant concentrations generally declined and, at least initially, the volume of water discharged from the Y-12 Complex declined. This reduction in discharge was of ecological concern and led to implementation of a flow management program for EFPC. Implementing flow management, in turn, led to substantial changes in chemical and physical conditions of the stream: stream discharge nearly doubled and stream temperatures decreased, becoming more similar to those in reference streams. While water quality clearly improved, meeting water quality standards alone does not guarantee protection of a waterbody s biological integrity. Results from studies on the ecological changes stemming from pollution-reduction actions, such as those presented in this series, also are needed to understand how best to restore or protect biological integrity and enhance ecological recovery in stream ecosystems. With a better knowledge of the ecological consequences of their decisions, environmental managers can better evaluate alternative actions and more accurately predict their effects.

54 ENVIRONMENTAL SCIENCES↗

Twenty-Plus Years of Environmental Change and Ecological Recovery of East Fork Poplar Creek: Background and Trends in Water Quality

In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Department of Energy's Y-12 National Security Complex (Y-12 Complex) in Oak Ridge, Tennessee, USA, allowing discharge of effluents to East Fork Poplar Creek (EFPC). The effluents ranged from large volumes of chlorinated once-through cooling water and cooling tower blow-down to smaller discharges of treated and untreated process wastewaters, which contained a mixture of heavy metals, organics, and nutrients, especially nitrates. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to meet two major objectives: demonstrate that the established effluent limitations were protecting the classified uses of EFPC, and document the ecological effects resulting from implementing a Water Pollution Control Program at the Y-12 Complex. The second objective is the primary focus of the other papers in this special series. This paper provides a history of pollution and the remedial actions that were implemented; describes the geographic setting of the study area; and characterizes the physicochemical attributes of the sampling sites, including changes in stream flow and temperature that occurred during implementation of the BMAP. Most of the actions taken under the Water Pollution Control Program were completed between 1986 and 1998, with as many as four years elapsing between some of the most significant actions. The Water Pollution Control Program included constructing nine new wastewater treatment facilities and implementation of several other pollution-reducing measures, such as a best management practices plan; area-source pollution control management; and various spill-prevention projects. Many of the major actions had readily discernable effects on the chemical and physical conditions of EFPC. As controls on effluents entering the stream were implemented, pollutant concentrations generally declined and, at least initially, the volume of water discharged from the Y-12 Complex declined. This reduction in discharge was of ecological concern and led to implementation of a flow management program for EFPC. Implementing flow management, in turn, led to substantial changes in chemical and physical conditions of the stream: stream discharge nearly doubled and stream temperatures decreased, becoming more similar to those in reference streams. While water quality clearly improved, meeting water quality standards alone does not guarantee protection of a waterbody's biological integrity. Results from studies on the ecological changes stemming from pollution-reduction actions, such as those presented in this series, also are needed to understand how best to restore or protect biological integrity and enhance ecological recovery in stream ecosystems. With a better knowledge of the ecological consequences of their decisions, environmental managers can better evaluate alternative actions and more accurately predict their effects.

54 ENVIRONMENTAL SCIENCES↗

Evolution of streamer groups in nonthermal plasma

Nonthermal plasmas (NTPs) induced by atmospheric nanosecond pulsed corona discharge have been studied for controlling pollution from combustors, such as boilers, incinerators, and diesel engines. In high-speed short-width high-voltage pulsed corona discharge-induced plasmas, primary streamer evolution is followed by secondary streamer evolution. Though this phenomenon is known experimentally, the details of the structures of the streamers and their evolution mechanisms have not been fully clarified. In this letter, we perform quasi two-dimensional numerical analysis of nonequilibrium NTP induced by a nanosecond positive pulsed corona discharge. The continuum fluid equations for two-temperature nonequilibrium NTP are used as governing equations. In this study, 197 gas phase reactions for 25 chemical species and 21 surface reactions on the inner glass wall surface are considered in an air plasma under atmospheric pressure. The simulated behavior of the streamer groups agrees with experimental observations. Soon after the voltage increases on the reactor, primary streamers are formed, which may transit the complete gap, disappearing near the peak voltage. Next, second streamers appear, disappearing at the end of the applied voltage pulse. The streamer wavelength and the distance between the streamers in the axial direction are determined. Moreover, ozone generation is shown to be more significant in the secondary streamer. This simulation will allow better predictions for nanosecond positive pulsed plasma systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Climate and air pollution implications of potential energy infrastructure and policy measures in India

India is a rapidly developing economy with interrelated air quality, sustainable development, and climate change mitigation goals. There are unique challenges to achieving each of these goals as well as potential tradeoffs among them. This study examines the implications of possible future energy, climate, and air pollution control policies and measures in India through 2050. We take a scenario approach using the GCAM global energy-climate-land model combined with the Hector simple climate model and the TM5-FASST air quality source-receptor model to examine energy, climate and air quality outcomes. Reducing use of traditional biomass in buildings can reduce primary carbonaceous particulate emissions well below 2015 levels. However, policies that are more ambitious than current plans would likely be required to reduce SO 2 and NO x emissions well below 2015 levels. Among single policy cases considered, pricing of greenhouse gas (GHG) emissions and expansion of natural gas infrastructure have the largest impacts on overall energy system changes relative to the reference scenario. Ambitious air pollution control and GHG policies lead to the largest reductions in air pollution concentrations and radiative forcing, respectively. However, ambitious air pollution control and GHG policies differ in the extent to which they support or impede other policy objectives. Forcing increases due to reduced aerosols from ambitious air pollution policies can be mitigated, at least in part, by applying air pollution control and GHG policies together.

India↗

Trace Element Sampling and Partitioning Modeling to Estimate Wastewater Composition and Treatment Performance at Coal Generators

The coal combusted at coal-fired power plants (CFPPs) contains several trace elements that impact human heath if released to the environment. Effective combinations of air pollution control devices (APCDs) and water pollution control devices (WPCDs) are critical to reducing these impacts. This work sampled pulverized CFPPs owned and operated by Louisville Gas & Electricity – Kentucky Utilities (LGE-KU) during baseload and cycling conditions. Next, an open-source and easy-to-implement trace element partitioning model was developed using publicly available datasets, literature studies of trace element partitioning, and sampling data to estimate trace element partitioning in APCDs to the gas, liquid, and solid phases exiting CFPPs. These estimates of the liquid phase trace element concentration in FGD wastewater were then used to estimate trace element behavior in WPCDs and evaluate treated wastewater effluent concentrations for compliance with the Effluent Limitation Guidelines (ELG) for the Steam Electric Generating Sector. Finally, cost estimates were developed for established and emerging wastewater treatment trains to identify the most cost-effective approaches for ELG compliance.

01 COAL, LIGNITE, AND PEAT↗

Electro Catalytic Oxidation (ECO) Operation

The power industry in the United States is faced with meeting many new regulations to reduce a number of air pollutants including sulfur dioxide, nitrogen oxides, fine particulate matter, and mercury. With over 1,000 power plants in the US, this is a daunting task. In some cases, traditional pollution control technologies such as wet scrubbers and SCRs are not feasible. Powerspan's Electro-Catalytic Oxidation, or ECO{reg_sign} process combines four pollution control devices into a single integrated system that can be installed after a power plant's particulate control device. Besides achieving major reductions in emissions of sulfur dioxide (SO{sub 2}), nitrogen oxides (NOx), fine particulate matter (PM2.5) and mercury (Hg), ECO produces a highly marketable fertilizer, which can help offset the operating costs of the process system. Powerspan has been operating a 50-MW ECO commercial demonstration unit (CDU) at FirstEnergy Corp.'s R.E. Burger Plant near Shadyside, Ohio, since February 2004. In addition to the CDU, a test loop has been constructed beside the CDU to demonstrate higher NOx removal rates and test various scrubber packing types and wet ESP configurations. Furthermore, Powerspan has developed the ECO{reg_sign}{sub 2} technology, a regenerative process that uses a proprietary solvent to capture CO{sub 2} from flue gas. The CO{sub 2} capture takes place after the capture of NOx, SO{sub 2}, mercury, and fine particulate matter. Once the CO{sub 2} is captured, the proprietary solution is regenerated to release CO{sub 2} in a form that is ready for geological storage or beneficial use. Pilot scale testing of ECO{sub 2} began in early 2009 at FirstEnergy's Burger Plant. The ECO{sub 2} pilot unit is designed to process a 1-MW flue gas stream and produce 20 tons of CO{sub 2} per day, achieving a 90% CO{sub 2} capture rate. The ECO{sub 2} pilot program provided the opportunity to confirm process design and cost estimates, and prepare for large scale capture and sequestration projects. The objectives of this project were to prove at a commercial scale that ECO is capable of extended operations over a range of conditions, that it meets the reliability requirements of a typical utility, and that the fertilizer co-product can be consistently generated, providing ECO with an economic advantage over conventional technologies currently available. Further objectives of the project were to show that the ECO system provides flue gas that meets the inlet standards necessary for ECO{sub 2} to operate, and that the outlet CO{sub 2} and other constituents produced by the ECO{sub 2} pilot can meet Kinder-Morgan pipeline standards for purposes of sequestration. All project objectives are consistent with DOE's Pollution Control Innovations for Power Plants program goals.

54 ENVIRONMENTAL SCIENCES↗

Surface Brightening in Eastern and Central China Since the Implementation of the Clean Air Action in 2013: Causes and Implications

Surface brightening has been observed in China since 2005. However, it remains unclear whether the brightening has accelerated recently in response to the strictest ever air pollution control policies since 2013. By combining intensive surface and satellite observations, we find an unprecedented rapid increasing trend in surface solar radiation (SSR) of 0.70–1.16 W m-2 yr-1 over the eastern and central China for 2014–2019. Using a novel method to identify the relative contributions of aerosol and cloud radiative effects to the SSR trends, we find that the strongly declining aerosol radiative effect due to the strict air pollution controls is the main cause of the upward SSR trends; cloud variations should not be the main reason. Distinction exists in seasonal trends of SSR, with decreasing trends in winter and increasing trends in other seasons. Air pollution controls play an important role in regulating SSR, which has valuable implications for photovoltaic power generation.

Shi, Hongrong↗

Mercury Remediation in Oak Ridge, Tennessee; Successes and Remaining Challenges - 19390

Mercury remediation is a high priority for the US Department of Energy's (DoE's) Environmental Management program in Oak Ridge, Tennessee because of large historical losses of mercury to the environment, and the potential health risks to humans and wildlife primarily through fish consumption. Remedial solutions for mercury contaminated aquatic systems are limited - many aquatic systems have diffuse sources of mercury (Hg) and depending on the environmental conditions, these low concentrations of inorganic Hg can result in fish consumption advisories due to the production of the more toxic methylmercury (MeHg) and its bioaccumulation and biomagnification. From the 1980's to the present, long-term monitoring of mercury concentrations in water and fish downstream of DOE facilities in Oak Ridge have provided an opportunity to assess the performance and effectiveness of various remedial and abatement actions to address mercury. Early actions in the mid-1980's focused on pollution control that positively affected mercury discharges to one local stream, including consolidation and elimination of untreated discharges, sanitary sewer relining, the construction of a pollution control facility, and the replacement of a contaminated settling basin. The 1990's were an intensive period of facility remedial actions designed to improve stream water quality and reduce mercury discharges. Actions included dechlorinating cooling water discharges, an additional phase of storm sewer relining, the addition of flow from a nearby reservoir, the addition of two small-scale mercury treatment systems, the bypass of stream flow around the settling basin, and the removal of high mercury-contaminated floodplain soils. Because of these multiple remedial actions total mercury concentrations in receiving streams decreased significantly; however, mercury concentrations in fish did not respond commensurately and remain a challenge to the present day. Although the mercury remedial strategy in Oak Ridge will continue to focus in the near-term on upstream facility source reduction, recent research suggests that understanding mercury transport, methylation, and bioaccumulation processes in the downstream environment is essential to reducing mercury fish concentrations. Since 2014, mercury remediation research and technology development activities have been underway to develop potential remedial solutions for the downstream environment, including use of sorbents to control soil leaching and the potential use of chemical or biological manipulations. The Oak Ridge mercury remediation story is a valuable case study for flowing systems that can inform our national-level understanding of potential mercury cleanup actions and their likely environmental response. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Emission, Transport, and Deposition of Mercury and Fine Particulate Matter from Coal-Based Power Plants in the Ohio River Valley Region

As stated in the proposal: Ohio University, in collaboration with CONSOL Energy, Advanced Technology Systems, Inc (ATS) and Atmospheric and Environmental Research, Inc. (AER) as subcontractors, evaluated the impact of emissions from coal-fired power plants in the Ohio River Valley region as they relate to the transport and deposition of mercury and associated fine particulate matter. This evaluation involved two interrelated areas of effort: ambient air monitoring and regional-scale modeling analysis. The scope of work for the ambient air monitoring included the deployment of a surface air monitoring (SAM) station in southeastern Ohio. The SAM station contains sampling equipment to collect and measure mercury (including speciated forms of mercury and wet and dry deposited mercury), particulate matter (PM) mass, PM composition, and gaseous criteria pollutants (CO, NOx, SO2, O3, etc.). Laboratory analyses of time-integrated samples were used to obtain chemical speciation of ambient PM composition and mercury in precipitation. Nearreal- time measurements were used to measure the ambient concentrations of PM mass and all gaseous species including Hg0 and RGM. Approximately 30 months of field data were collected at the SAM site to validate the proposed regional model simulations for episodic and seasonal model runs. The ambient air quality data provides mercury, and fine particulate matter data that can be used by Ohio Valley industries to assess performance on multi-pollutant control systems. The scope of work for the modeling analysis includes (1) development of updated inventories of mercury emissions from coal plants and other important sources in the modeled domain; (2) adapting an existing 3-D atmospheric chemical transport model to incorporate recent advancements in the understanding of mercury transformations in the atmosphere; (3) analyses of the flux of Hg0, RGM, and fine particulate matter in the different sectors of the study region to identify key transport mechanisms; (4) comparison of cross correlations between species from the model results to observations in order to evaluate characteristics of specific air masses associated with long-range transport from a specified source region; and (5) evaluation of the sensitivity of these correlations to emissions from regions along the transport path. This is accomplished by multiple model runs with emissions simulations switched on and off from the various source regions. To the greatest extent possible, model results were compared to field data collected at other air monitoring sites in the Ohio Valley region, operated independently of this project. These sites may include (1) the DOE National Energy Technologies Laboratory’s monitoring site at its suburban Pittsburgh, PA facility; (2) sites in Pittsburgh (Lawrenceville) PA and Holbrook, PA operated by ATS; (3) sites in Steubenville, OH and Pittsburgh, PA operated by the USEPA and/or its contractors; and (4) sites operated by State or local air regulatory agencies. Field verification of model results and predictions provides critical information for the development of cost effective air pollution control strategies by the coal-fired power plants in the Ohio River Valley region.

01 COAL, LIGNITE, AND PEAT↗

A cost-benefit analysis of a pellet boiler with electrostatic precipitator versus conventional biomass technology: A case study of an institutional boiler in Syracuse, New York

Background: Biomass facilities have received increasing attention as a strategy to increase the use of renewable fuels and decrease greenhouse gas emissions from the electric generation and heating sectors, but these facilities can potentially increase local air pollution and associated health effects. Comparing the economic costs and public health benefits of alternative biomass fuel, heating technology, and pollution control technology options provides decision-makers with the necessary information to make optimal choices in a given location. Methods: For a case study of a combined heat and power biomass facility in Syracuse, New York, we used stack testing to estimate emissions of fine particulate matter (PM{sub 2.5}) for both the deployed technology (staged combustion pellet boiler with an electrostatic precipitator) and a conventional alternative (wood chip stoker boiler with a multicyclone). We used the atmospheric dispersion model AERMOD to calculate the contribution of either fuel-technology configuration to ambient primary PM{sub 2.5} in a 10 km×10 km region surrounding the facility, and we quantified the incremental contribution to population mortality and morbidity. We assigned economic values to health outcomes and compared the health benefits of the lower-emitting technology with the incremental costs. Results: In total, the incremental annualized cost of the lower-emitting pellet boiler was $190,000 greater, driven by a greater cost of the pellet fuel and pollution control technology, offset in part by reduced fuel storage costs. PM{sub 2.5} emissions were a factor of 23 lower with the pellet boiler with electrostatic precipitator, with corresponding differences in contributions to ambient primary PM{sub 2.5} concentrations. The monetary value of the public health benefits of selecting the pellet-fired boiler technology with electrostatic precipitator was $1.7 million annually, greatly exceeding the differential costs even when accounting for uncertainties. Our analyses also showed complex spatial patterns of health benefits given non-uniform age distributions and air pollution levels. Conclusions: The incremental investment in a lower-emitting staged combustion pellet boiler with an electrostatic precipitator was well justified by the population health improvements over the conventional wood chip technology with a multicyclone, even given the focus on only primary PM{sub 2.5} within a small spatial domain. Our analytical framework could be generalized to other settings to inform optimal strategies for proposed new facilities or populations. - Highlights: • PM{sub 2.5} emissions vary greatly across alternative biomass fuels and technologies. • A pellet boiler had a factor of 23 lower emissions than a conventional alternative. • The incremental annualized cost of the lower-emitting technology was $190,000. • The monetary value of annual health benefits of reduced emissions was $1.7 million. • Our analytical framework provides insight about optimal biomass technologies.

09 BIOMASS FUELS↗

Mercury Remediation in Oak Ridge, Tennessee; Successes and Remaining Challenges

Mercury remediation is a high priority for the US Department of Energy’s (DOE’s) Environmental Management program in Oak Ridge, Tennessee because of large historical losses of mercury to the environment, and the potential health risks to humans and wildlife primarily through fish consumption. Remedial solutions for mercury contaminated aquatic systems are limited – many aquatic systems have diffuse sources of mercury (Hg) and depending on the environmental conditions, these low concentrations of inorganic Hg can result in fish consumption advisories due to the production of the more toxic methylmercury (MeHg) and its bioaccumulation and biomagnification. From the 1980s to the present, long-term monitoring of mercury concentrations in water and fish downstream of DOE facilities in Oak Ridge have provided an opportunity to assess the performance and effectiveness of various remedial and abatement actions to address mercury. Early actions in the mid-1980s focused on pollution control that positively affected mercury discharges to one local stream, including consolidation and elimination of untreated discharges, sanitary sewer relining, the construction of a pollution control facility, and the replacement of a contaminated settling basin. The 1990s were an intensive period of facility remedial actions designed to improve stream water quality and reduce mercury discharges. Actions included dechlorinating cooling water discharges, an additional phase of storm sewer relining, the addition of flow from a nearby reservoir, the addition of two small-scale mercury treatment systems, the bypass of stream flow around the settling basin, and the removal of high mercury-contaminated floodplain soils. Because of these multiple remedial actions total mercury concentrations in receiving streams decreased significantly; however, mercury concentrations in fish did not respond commensurately and remain a challenge to the present day. Although the mercury remedial strategy in Oak Ridge will continue to focus in the near-term on upstream facility source reduction, recent research suggests that understanding mercury transport, methylation, and bioaccumulation processes in the downstream environment is essential to reducing mercury fish concentrations. Since 2014, mercury remediation research and technology development activities have been underway to develop potential remedial solutions for the downstream environment, including use of sorbents to control soil leaching and the potential use of chemical or biological manipulations. The Oak Ridge mercury remediation story is a valuable case study for flowing systems that can inform our national-level understanding of potential mercury cleanup actions and their likely environmental response.

Peterson, Mark J.↗