Search NASA⌕ Search

SEARCH · Search NASA

Results for “POROUS WALL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Wind tunnel wall interference in closed, ventilated and adaptive test sections

A wall interference correction method for closed rectangular test sections was developed which uses measured wall pressures. Measurements with circular discs for blockage and a rectangular wing as a lift generator in a square closed test section validate this method. These measurements are intended to be a basis of comparison for measurements in the same tunnel using ventilated (in these case, slotted) walls. Using the vortex lattice method and homogeneous boundary conditions, calculations were performed which show sufficiently high pressure levels at the walls for correction purposes in test sections with porous walls. In Gottingen, an adaptive test section (which is a deformable rubber tube of 800 mm diameter) was built and a computer program was developed which is able to find the necessary wall adaptation for interference-free measurements in a single step. To check the program prior to the first run, the vortex lattice method was used to calculate wall pressure distributions in the nonadapted test section as input data for the one-step method. Comparison of the pressure distribution in the adapted test section with free-flight data shows nearly perfect agreement. An extension of the computer program can be made to evaluate the remaining interference corrections.

Holst, H.↗

Turbulent boundary layer over solid and porous surfaces with small roughness

Skin friction and profiles of mean velocity, axial and normal turbulence intensity, and Reynolds stress in the untripped boundary layer were measured directly on a large diameter, axisymmetric body with: (1) a smooth, solid surface; (2) a sandpaper-roughened, solid surface; (3) a sintered metal, porous surface; (4) a smooth, perforated titanium surface; (5) a rough solid surface made of fine, diffusion bonded screening, and (6) a rough, porous surface of the same screening. Results obtained for each of these surfaces are discussed. It is shown that a rough, porous wall simply does not influence the boundary layer in the same way as a rough solid wall. Therefore, turbulent transport models for boundary layers over porous surfaces either with or without injection or suction, must include both surface roughness and porosity effects.

Kong, F. Y.↗

Analysis of Laminar Incompressible Flow on Semiporous Channels

Perturbation solutions for laminar incompressible flow in semiporous and fully porous channels are compared. The perturbation parameter measures the amount of suction or blowing at the porous wall. The velocity profile and the wall friction parameter are more affected by suction or blowing for the semiporous channel than for the fully porous channel. For blowing through the wall, the pressure decreases in channel direction for both channels; with sufficiently high suction rates, the analysis showed that the pressure rises in flow direction for the fully porous channel.

PIPES↗

Reduction of wind tunnel wall interference by controlled wall flow

An alternate method of testing was developed in which flow through the porous walls of the tunnel was actively controlled so as to approximate free air conditions in the neighborhood of the model during the test. The amount and distribution of the controlled flow through the walls is computed using a potential flow representation of the model based on the measured lift. Theoretical analysis is presented to prove the convergence of the method to free air conditions and to substantiate the general three-dimensional theory of operation when the normal flow distribution is continuous. A two-dimensional tunnel was constructed to evaluate the concept. Results show that substantial reduction of wall interference may be achieved with relatively low values of porosity of actively controlled walls.

Bernstein, S.↗

Quiet wind tunnel

Simple and inexpensive technique suppresses background noise generated by pores in wind tunnel wall lining and makes aerodynamic data more accurate and reliable. Porous walls are covered with wire-mesh screen. Screen offers smoother surface to airflow and damps vortexes and resonance caused by wall perforations; yet it provides enough open area for perforations to cancel shock waves generated by model.

Howard, P. W.↗

Initial Calibrations and Wind Tunnel Test Results for an In-Flow Reference Array Using New In-Flow Acoustic Sources in Four Array Mount Configurations

This paper describes efforts to develop a small in-flow phased microphone array as a reference acoustic sensor and quantify its level-measurement accuracy with new in-flow calibration sources. The devices can be applied to a wide variety of in- and out-of-flow measurement applications and test facilities. Recent tests of the array and two calibration sources in the NASA Anechoic Chamber and Army 7- by 10-foot Wind Tunnel at NASA Ames Research Center demonstrated that the array was functional over a frequency range of 2 to 100 kilohertz for emission angles of 92 degrees, 108 degrees, and 120 degrees, and Mach numbers of 0, 0.15, and 0.25. The array and calibration sources were then used to assess the relative effects of array installation on background noise and level measurement accuracy by locating the array in the flow (strut- and wall-mounted) as well as outside the flow behind a porous wall screen and a free shear layer. The wind tunnel array measurements were compared with anechoic chamber measurements using discrete microphones at the same source distance and emission angles. At 92 degrees, the noise floor and attenuation spectra were comparable (within 5 decibels) for each installation from 2 to 30 kilohertz. At higher angles, the array installation behind the Kevlar screen had the lowest noise floor at M = 0.15 and 0.25. The array installation 10 inches (maximum available distance) behind a free shear layer had higher background noise that is typically reduced to a lower level by moving the array back further from the flow. For emission angles greater than 92 degrees, both the Kevlar and free shear layer installations exhibited stronger attenuations in measured level, beginning at lower frequencies than either the wall- or strut-mount configurations. Additional array and calibration source units of the same design are being tested at NASA’s Glenn Research Center and Langley Research Center in their aeroacoustic research facilities in an effort to improve measurement accuracy and repeatability.

Aeroacoustic Wind Tunnel Research↗

Drag Measurements of Porous Plate Acoustic Liners

This paper presents the results of direct drag measurements on a variety of porous plate acoustic liners. The existing literature describes numerous studies of drag on porous walls with injection or suction, but relatively few of drag on porous plates with neither injection nor suction. Furthermore, the porosity of the porous plate in existing studies is much lower than typically used in acoustic liners. In the present work, the acoustic liners consisted of a perforated face sheet covering a bulk acoustic absorber material. Factors that were varied in the experiment were hole diameter, hole pattern, face sheet thickness, bulk material type, and size of the gap (if any) between the face sheet and the absorber material.

Wolter, John D.↗

Prediction and rational correlation of thermophoretically reduced particle mass transfer to hot surfaces across laminar or turbulent forced-convection gas boundary layers

A formulation previously developed to predict and correlate the thermophoretically-augmented submicron particle mass transfer rate to cold surfaces is found to account for the thermophoretically reduced particle mass transfer rate to overheated surfaces such that thermophoresis brings about a 10-decade reduction below the convective mass transfer rate expected by pure Brownian diffusion and convection alone. Thermophoretic blowing is shown to produce effects on particle concentration boundary-layer (BL) structure and wall mass transfer rates similar to those produced by real blowing through a porous wall. The applicability of the correlations to developing BL-situations is demonstrated by a numerical example relevant to wet-steam technology.

Gokoglu, Suleyman A.↗

Experimental investigation of wall shock cancellation and reduction of wall interference in transonic testing

A series of experiments were performed to evaluate the effectiveness of a three-dimensional land and groove wall geometry and a variable permeability distribution to reduce the interference produced by the porous walls of a supercritical transonic test section. The three-dimensional wall geometry was found to diffuse the pressure perturbations caused by small local mismatches in wall porosity permitting the use of a relatively coarse wall porosity control to reduce or eliminate wall interference effects. The wall porosity distribution required was found to be a sensitive function of Mach number requiring that the Mach number repeatability characteristics of the test apparatus be quite good. The effectiveness of a variable porosity wall is greatest in the upstream region of the test section where the pressure differences across the wall are largest. An effective variable porosity wall in the down stream region of the test section requires the use of a slightly convergent test section geometry.

Ferri, A.↗

Solutions of laminar-boundary-equations which result in specific-weight-flow profiles locally exceeding free-stream values

Revised solutions of the laminar-boundary-layer equations for cases which involved cooling at the wall combined with large pressure gradients in the main stream produced specific-weight-flow profiles which locally exceeded free-stream values. Heat-transfer and friction coefficients, boundary-layer thicknesses, and velocity, temperature, and specific-weight-flow distributions resulting from the revised solutions are presented for Euler numbers of 0.5 and 1, stream-to-wall temperature ratios of 2 and 4, and cooling-air flow rates through porous walls designated by flow parameters of 0, -0.5, and -1.

HEAT TRANSFER, AERODYNAMIC↗

Transpiration Cooling Experiment

The transpiration cooling method was considered for a scram-jet engine to accommodate thermally the situation where a very high heat flux (200 Btu/sq. ft sec) from hydrogen fuel combustion process is imposed to the engine walls. In a scram-jet engine, a small portion of hydrogen fuel passes through the porous walls of the engine combustor to cool the engine walls and at the same time the rest passes along combustion chamber walls and is preheated. Such a regenerative system promises simultaneously cooling of engine combustor and preheating the cryogenic fuel. In the experiment, an optical heating method was used to provide a heat flux of 200 Btu/sq. ft sec to the cylindrical surface of a porous stainless steel specimen which carried helium gas. The cooling efficiencies by transpiration were studied for specimens with various porosity. The experiments of various test specimens under high heat flux have revealed a phenomenon that chokes the medium flow when passing through a porous structure. This research includes the analysis of the system and a scaling conversion study that interprets the results from helium into the case when hydrogen medium is used.

Song, Kyo D.↗

Cascaded Perforates as One-Dimensional, Bulk Absorbers

Porous cell honeycomb liners for aircraft engine nacelles offer the possibility of exploiting extended reaction effects to improve liner attenuation bandwidth as generally attributed to the performance of bulk absorbers. This paper describes an analytical procedure, starting with an impedance prediction model for a single perforated plate, to estimate the bulk-absorber parameters for a cascade of such perforates - a first step to modeling a porous wall honeycomb structure. The objective is to build confidence in a lumped element impedance model, when applied to a uniformly-spaced set of porous plates to predict its .bulk. absorber properties. The model is based upon a modified version of the two-parameter flow resistance model of the form A + BV(sub inc), where A and B are physics-based, semi-empirical parameters that are adjusted to provide an optimum fit to a composite dataset from three plate porosities of 2.5, 5 and 10%. The composite dataset is achieved by reformulating the two-parameter flow resistance model into a .reduced pressure drop coefficient. dependency on perforate hole Reynolds number. The resulting impedance model is employed to calculate surface impedance spectra for N and 2N-layer perforate cascades. The well-known two-thickness method for experimental determination of bulk-absorber parameters is then applied to these .synthesized. data sets to predict the characteristic impedance and propagation constant for the perforate cascades. These results are then compared with experimental results reported in a companion paper.

Parrott, T. L.↗

Determination of boundary shape of cooled porous region

The shape of a cooled porous wall section is found that will provide a uniform surface temperature, as dictated by material limitations, when the surface is subjected to spatially nonuniform heating. In the analysis, local temperatures and pressures in the porous material are expressed in terms of a potential function. From the imposed thermal conditions, this potential function is governed by the dual constraints of both its value and its normal derivative being specified along the heated surface. The unknown shape of this surface is obtained by meeting these dual conditions. The analytical method uses a generalized conformal mapping procedure that includes a curved boundary. The coolant flow can be compressible or incompressible, and its viscosity can depend on temperature.

Snyder, A.↗

Reduction of wind-tunnel wall interference by controlled wall flow

Corrections for wind tunnel wall interferences are applied successfully to high lift models when the model to tunnel size ratio is small. The accuracy of the corrections becomes poorer when larger models are tested. An alternate method of testing was developed in which flow through the porous walls of the tunnel was actively controlled so as to approximate free air conditions in the neighborhood of the model during the test. The amount and distribution of the controlled flow through the walls is computed using a potential flow representation of the model based on the measured lift. Theoretical analysis is presented to prove the convergence of the method to free air conditions and to substantiate the general three dimensional theory of operation when the normal flow distribution is continuous. A two dimensional tunnel was constructed to evaluate the concept. Results show that substantial reduction of wall interference may be achieved with relatively low values of porosity of actively controlled walls.

Bernstein, S.↗

Flow Simulation of Solid Rocket Motors: Sub-Scale Air Flow Simulation of Port Flows - 2

The injection-flow issuing from a porous medium in the cold-flow simulation of internal port flows in solid rocket motors is characterized by a spatial instability termed pseudoturbulence that produces a rather non-uniform (lumpy) injection-velocity profile. The objective of this study is to investigate the interaction between the injection- and the developing axial-flows. The findings show that this interaction generally weakens the lumpy injection profile and affects the subsequent development of the axial flow. The injection profile is found to depend on the material characteristics, and the ensuing pseudoturbulence is a function of the injection velocity, the axial position and the distance from the porous wall. The flow transition (from laminar to turbulent) of the axial-flow is accelerated in flows emerging from smaller pores primarily due to the higher pseudoturbulence produced by the smaller pores in comparison to that associated with larger pores. In flows with rather uniform injection-flow profiles (weak or no pseudoturbulence), the axial and transverse velocity components in the porous duct are found to satisfy the sine/cosine analytical solutions derived from inviscid assumptions. The transition results from the present study are compared with previous results from surveyed literature, and detailed flow development measurements are presented in terms of the blowing fraction, and characterizing Reynolds numbers.

Yeh, Y. P.↗

Improved Models for the Porous Surface with Passive Control

A computational investigation of afterbody flow using a passive control method is conducted. The passive control method consists of a porous surface placed over a plenum. The purpose of the passive control method is to exploit the adverse pressure gradient present in afterbody flow in an attempt to reduce boundary layer separation and afterbody drag. Four different porous wall models are used to model the transpiration velocity in the region of passive control. A three-dimensional, time-dependent, Reynolds-averaged, simplified Navier-Stokes solver, PAB3D, is used to simulate afterbody flow with and without passive control. Three afterbody configurations with boat-tail angles of 10, 20, and 30 deg. are used to obtain two-dimensional solutions with a freestream Mach number of 0.6 and nozzle pressure ratio of 6. The region of passive control was initially placed from 20-60% of the nozzle length. The effect of the porous placement and porous extent is also studied. Baseline (no porosity) two-dimensional solutions are qualitatively similar to experimental data but under-predict the magnitude of the pressure recovery. Results for the subsonic solutions show losses in the pressure recovery for some cases with passive control. Three-dimensional effects are also investigated and seen to be very significant. Three-dimensional baseline solutions, for both sub- and super-critical freestream Mach numbers, compare very favorably with the experimental data in comparison to the two-dimensional solution. Future work is required to examine three-dimensional afterbody flows with passive porosity.

Kraushaar, Sandra L.↗

Method of electroforming a rocket chamber

A transpiration cooled rocket chamber is made by forming a porous metal wall on a suitably shaped mandrel. The porous wall may be made of sintered powdered metal, metal fibers sintered on the mandrel or wires woven onto the mandrel and then sintered to bond the interfaces of the wires. Intersecting annular and longitudinal ribs are then electroformed on the porous wall. An interchamber wall having orifices therein is then electroformed over the annular and longitudinal ribs. Parallel longitudinal ribs are then formed on the outside surface of the interchamber wall after which an annular jacket is electroformed over the parallel ribs to form distribution passages therewith. A feed manifold communicating with the distribution passages may be fabricated and welded to the rocket chamber or the feed manifold may be electroformed in place.

Fortini, A.↗