Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER TRANSMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multi-mode power split hybrid transmission with two planetary gear mechanisms

A multi-mode, power-split hybrid transmission system having two planetary gear (PG) sets connected to one engine, two electric motors, one output shaft, and each other by several clutches, brakes, and direct connection elements. Depending on the specific location and actuation of the various clutch and brake elements, the multi-mode, power-split hybrid transmission system can be run in one of several modes (e.g. electric drive, power-split, parallel hybrid, series hybrid, electronic continuously variable transmission (eCVT), generator, neutral, and the like).

33 ADVANCED PROPULSION SYSTEMS↗

Integrating Variable Renewable Energy Into the Grid: Key Issues

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. The variability of solar and wind compared to traditional sources, coupled with growing demand for electricity, requires changes to power system planning and operations to meet these targets. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE), primarily wind and solar, to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE while maintaining or increasing system stability and reliability. To inform decarbonization strategies, policymakers, regulators, and system operators consider a variety of costs and opportunities associated with VRE integration, which can be organized into five topics: New renewable energy generation and transmission; Power system reliability; Transmission and distribution coordination; Cross-sectoral decarbonization opportunities; Energy equity and justice.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Convex Relaxations of Maximal Load Delivery for Multi-Contingency Analysis of Joint Electric Power and Natural Gas Transmission Networks

Recent increases in gas-fired power generation have engendered increased interdependencies between natural gas and power transmission systems. These interdependencies have amplified existing vulnerabilities in gas and power grids, where disruptions can require the curtailment of load in one or both systems. Although typically operated independently, coordination of these systems during severe disruptions can allow for targeted delivery to lifeline services, including gas delivery for residential heating and power delivery for critical facilities. To address the challenge of estimating maximum joint network capacities under such disruptions, we consider the task of determining feasible steady-state operating points for severely damaged systems while ensuring the maximal delivery of gas and power loads simultaneously, represented mathematically as the nonconvex joint Maximal Load Delivery (MLD) problem. To increase its tractability, we present a mixed-integer convex relaxation of the MLD problem. Then, to demonstrate the relaxation’s effectiveness in determining bounds on network capacities, exact and relaxed MLD formulations are compared across various multi-contingency scenarios on nine joint networks ranging in size from 25 to 1191 nodes. The relaxation-based methodology is observed to accurately and efficiently estimate the impacts of severe joint network disruptions, often converging to the relaxed MLD problem’s globally optimal solution within ten seconds.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MASK4 Test Campaign for Sandia WaveBot Device

This data and report details the findings from a wave tank test focused on production of useful work of a wave energy converter (WEC) device. The experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance. These data describe the "MASK4" wave tank test of the Sandia WaveBot device. The WaveBot device has been tested a number of times in different permutations at the US Navy's Maneuvering and Sea Keeping (MASK) basin. Each test in this series is referred to as MASK1, MASK2, etc. The WaveBot device was first tested in one degree of freedom (heave) in 2016. This MASK1 test focused primarily on system identification and modeling. After MASK1, major modifications were performed to improve the overall real-time control and measurement system, improve the heave drive train, and add surge and pitch degrees of freedom. The second set of testing, which was broken up in to two stages: MASK2A and MASK2B, focused on bench testing and closed-loop control performance as well as nonlinear modeling. MASK3 then focused on multi-input, multi-output modeling and control for maximization of electrical power. The attached report presents the results from MASK4, which focuses on detailed modeling of the power conversion chain and validation co-design principles by way of the introduction of a magnetic spring. The test log, report, and data from the MASK4 test of the WaveBot augmented with a tunable magnetic spring. Processing codes can be found at the Github link below.

16 TIDAL AND WAVE POWER↗

MASK4 Test Report

Wave energy converters (WECs) are designed to produce useful work from ocean waves. This useful work can take the form of electrical power or even pressurized water for, e.g., desalination. This report details the findings from a wave tank test focused on that production of useful work. To that end, the experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance.

16 TIDAL AND WAVE POWER↗

Aluminum Ultra-conductors for Energy-Efficient Aerospace Busbar Applications (Abstract)

In this project, we will develop aluminum ultra-conductors with graphene additives demonstrating enhanced electrical conductivity at 90 °C compared to electric grade aluminum alloy AA1100 (43% IACS at 90 °C). While ultra-conductivity has been developed in copper and copper alloys, it is yet to be reported extensively in aluminum-based materials. This project will scale initial work done at PNNL on aluminum ultra-conductors using shear-assisted processing and extrusion (ShAPETM), a novel solid phase processing technique. Ultra-conductors are an emerging class of composites, comprised of a metal substrate with small quantities of nanocrystalline additives such as graphene or carbon nanotubes that demonstrate enhanced conductivity at relevant operating temperatures. Aluminum ultra-conductors can improve efficiency and power density while reducing the demand for copper in a wide range of applications, such as power transmission cables and electric motors. Busbars are an important component in aerospace systems that require lightweight and high-current power distribution including both future electric vertical take-off and landing (eVTOL) aircrafts and current aircraft electrical systems. We will accelerate aluminum ultra-conductor composite formulation development using combinatorial synthesis and testing methods aided by process/microstructure modeling, developed previously at PNNL. Eaton will test the properties of the ShAPE aluminum ultra-conductor feedstock (used to make the busbars) in relevant operating conditions (20 – 90 °C), predict the improvement in busbar performance when manufactured with ultra-conductors over commercial conductors (such as AA1100), and perform technoeconomic analysis to evaluate the potential for commercialization of ShAPE aluminum ultra-conductors. The project is expected to have a budget of $\$375$K, with $\$300$K in federal funding and $\$75$K in-kind cost-share contribution from Eaton over a period of performance of 24 months. Of the $\$300$K of federal funds, $\$140$K is allocated for CRADA activities that generate intellectual property (IP), and the remaining $\$160$K is reserved for modeling, material testing, characterization, travel, and reporting-related activities.

36 MATERIALS SCIENCE↗

Disaggregating Future Retail Electricity Rate Growth [Slides]

Recent Berkeley Lab research found that modest retail rate increases over the past 10 years were mostly driven by large increases in capital expenditures (CapEx) that were offset in part by substantial wholesale price reductions. Decision-makers are increasingly concerned about the potential future rate impacts of a number of policies and industry trends that support rapid decarbonization, electrification, and grid modernization. Using historical FERC Form 1 data and the existing literature on policies and industry trends that are likely to affect utility-incurred costs and retail sales, Berkeley Lab researchers developed ranges of forecasted growth rates for cost-related rate drivers (i.e., fuel and purchased power; transmission, distribution, generation, and other categories of both non-fuel operations & maintenance and CapEx) and non-cost related rate drivers (i.e., retail sales, peak demand, and customers). These were then used as inputs to a pro-forma utility financial model (FINDER) that estimated the growth in retail electric rates between 2020 and 2030 for a prototypical vertically-integrated investor-owned utility in the United States. The analysis produced the following results: 1. Assuming average growth rates in all rate drivers, future retail rate growth is driven by sizable increases in all CapEx costs, where fuel and purchased power costs are replaced by generation CapEx as the largest rate component between 2020 and 2030. 2. Growth in sales/peak demand/customers, generation CapEx costs, and fuel and purchased power (FPP) costs, in isolation, produce the most uncertainty in rate growth. Specifically, a 1% increase in the compound annual growth rate (CAGR) of retail sales, coincident peak demand (CP), and customers (Sales-CP-Cust) results in a 0.88-0.93% decrease in the CAGR of rates, in isolation. However, a 1% increase in the CAGR of generation CapEx budgets results in a 0.07-0.14% increase in the CAGR of rates, while a 1% increase in the CAGR of FPP costs causes a 0.10-0.14% increase in the CAGR of rates, all else being equal. 3. Taking into account the correlation and variability of the growth in all rate drivers jointly, generation CapEx is expected to be both the largest and most uncertain rate component by 2030 (20-25% share of the retail rate). Transmission and distribution CapEx, along with fuel and purchased power costs are each expected to comprise between 12% and 17% of retail rates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Control of the Energy-Saving Hybrid Hydraulic-Electric Architecture (HHEA) for Off-Highway Mobile Machines

Most off-highway constructions and agriculture equipment use hydraulics, which has unmatched power density, for power transmission and throttling as a means for control. A novel hybrid hydraulic-electric architecture (HHEA) has recently been proposed to improve efficiency for high-power machines that would have been cost-prohibitive to electrify directly. HHEA uses a set of common pressure rails (CPRs) to transmit the majority of power hydraulically and small electric motor drives to modulate that power and to achieve precise control. This article proposes a computationally efficient Lagrange multiplier method (LMM) for computing the optimal sequence of pressure rail selections to minimize energy use. This is needed to evaluate HHEA's energy-saving potential and for iterative architecture design and sizing. An interesting complication is that the cost function is not fully defined until the candidate control sequence is fully specified. This issue is dealt with by decomposing the original problem into a set of sub-problems with additional constraints that can be solved efficiently. Computational effort can be further reduced if actuators are optimized individually instead of together. However, additional steps are required to prevent the constraint functions from becoming discontinuous with respect to the Lagrange multipliers, which is necessary for meeting the constraints. Lastly, a case study of a construction machine demonstrates the efficacy of the method and shows that the HHEA reduces energy consumption by 68%-73% compared to the baseline load-sensing architecture.

Lagrange multiplier↗

Queued Up: 2026 Edition, Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2025 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with https://www.interconnection.fyi. Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 50 non-ISO balancing areas), which collectively represent ~98% of currently installed U.S. electric generating capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electron Bernstein wave conversion of high-field side injected X-modes in QUEST

This paper presents a detailed design of the Q-shu University experimental steady state spherical tokamak's (QUEST's) high-field side (HFS) injection system for electron Bernstein wave (EBW) excitation and the results of an experimental comparison of the HFS eXtraordinary X-mode and low-field side (LFS) ordinary O-mode injection of 8.2 GHz radio frequency (RF) power. Waveguides, as an alternative to mirror polarizers for transmitting RF X-mode power from LFS to HFS for EBW conversion, were used instead of the installation of an RF mirror. Testing of LFS-to-HFS RF power transmission at 8.2 GHz, using an RG-50-type vacuum waveguide in a bench-scale device filled with SF6 gas at 0.03 Mpa, revealed that an RF power of 10.8 kW could traverse the fundamental electron cyclotron resonance layer for 60 s without breakdown. The short-length, open-ended waveguide antenna used in the HFS injection-induced wave diffraction reduced the efficiency of power delivery to the upper hybrid resonance (UHR) by approximately 7% at an electron temperature of 50 eV. The HFS injection was able to produce brighter camera images than the standard LFS injection. The location of the UHR, as estimated by measuring the density with an interferometer, agreed with its location as measured by plasma radiation low-field, side-edge positions shown by fast camera imaging. This indicates that the plasma was produced by mode-converted EBW. The HFS injection had an absorption efficiency of 96%, compared to 40% for LFS. A greater fluctuation of floating potential adjustable to the lower hybrid wave (LHW) was observed in the HFS case by installing a Langmuir probe, confirming that EBW conversion efficiency was higher in the HFS case. Moreover, after setting the poloidal field to B PF = 7.6 mT, plasma current (I P ) in the HFS peaked at 1.3 kA, as opposed to 0.3 kA for LFS, despite LFS injection having a total power of 55 kW, compared to 40 kW for HFS. However, as the impurity level was comparatively high, it is believed that this I P is dominated by pressure-drive, which makes it difficult to analyze EBWCD. Finally, the line-integrated density in the HFS injection peaked at 1.6 × 10 18 m -2 , compared to 8 × 10 17 m -2 in the LFS one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subcutaneous power supply by NIR-II light

Implantable medical devices are wished to be recharged via contactless power transfer technologies without interventional operations. Superior to subcutaneous power supply by visible light or electromagnetic wave, second near-infrared (NIR-II) light is predicted to possess 60 times subcutaneous power transmission but hard to be utilized. Here we report a photo-thermal-electric converter via the combination of photothermal conversion and thermoelectric conversion. It is able to generate an output power as high as 195 mW under the coverage of excised tissues, presenting advantages of non-invasion, high output power, negligible biological damage, and deep tissue penetration. As an in vivo demonstration, the output power of a packaged converter in the abdominal cavity of a rabbit reaches 20 mW under NIR-II light irradiation through the rabbit skin with a thickness of 8.5 mm. This value is high enough to recharge an implanted high-power-consumption wireless camera and transfer video signal out of body in real-time.

60 APPLIED LIFE SCIENCES↗

Implantable photoelectronic charging (I-PEC) for medical implants

Medical implants with functionalities such as sensing, health monitoring, stimulation, diagnosis, and physiological treatment are rapidly growing. With the increasing functional sophistication and addition of modules such as data transmission, on-chip processing, and data storage, energy demand of the implantable system is also growing. Using implantable energy harvester either to recharge or ultimately replace hazardous battery is essential to provide a long-term sustainable solution. Furthermore, energy harvesting techniques using piezoelectric, thermoelectric, radio frequency power transmission, biofuel, and photoelectronic (or sometimes termed as “photovoltaic” in terms of solar light harvesting, i.e., PV) conversion, have been attempted for the implantable, but these methods are currently limited by insufficient power output, large footprint, and low efficiency. Nevertheless, the planar PV with potential of lighter weight, higher energy density, and higher efficiency, provides promising power solution for in-body medical implants. In this short review, we will discuss the potential opportunities and challenges associated with PV's for medical implants, covering materials, to devices, and to system level requirements.

60 APPLIED LIFE SCIENCES↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Eye-Safe 1.5 and 2.0 Micron Laser Power Conversion Using Metamorphic InGaAs Photovoltaic Devices

Laser power transmission at 1.5 and 2.0 microns are considered eye-safe up to 0.1 W/cm2 irradiance. Further, the atmospheric bands at these two wavelengths may provide the highest optical transmission through the atmosphere in hazy conditions. By slowly changing the lattice-constant of InGaAs with a Compositionally Graded Buffer (CGB), we have fabricated InGaAs photovoltaic (PV) devices over a wide range of bandgaps useful for multijunction concentrating photovoltaic devices, thermophotovoltaic devices, and Laser Power Converters (LPC). Here, we have demonstrated monochromatic power conversion of 1.5-micron light with an eye-safe efficiency of 39.8% at 0.1 W/cm2 with InGaAs devices lattice-matched to InP with an Antireflection Coating (ARC). We have also demonstrated 30.2% and 24.5% eye-safe LPC efficiency of metamorphic InGaAs devices grown on GaAs substrates using GaInP and AlGaAsP CGBs, respectively. Finally, we have demonstrated metamorphic InGaAs devices grown on InP and GaAs substrates that are estimated to have eye-safe LPC efficiencies at 2.0 microns of 27.4% and 20.9% respectively. The efficiencies of all these LPC devices continues to increase up to about 30-70 times the eye-safe irradiance.

eye-safe↗

Experimental Evaluation of Interference in 2.4 GHz Wireless Network

To attain automation across different applications, nuclear power plants are beginning to leverage advancements in wireless communication technologies. A “one-size-fits-all” solution cannot be applied since wireless technologies are selected according to application needs, quality of service requirements, and economic restrictions. To balance the trade-off between technical and economic requirements, a multi-band heterogeneous wireless network architecture is needed. Numerous wireless technologies including Wi-Fi, Zigbee, and Bluetooth share the 2.4 GHz industrial, scientific, and medical band. However, due to different channel access mechanisms and transmit power levels, and very importantly, uncoordinated use, coexistence of these devices in the same vicinity can cause interference and degradation in performance. This report provides the technical basis for understanding the coexistence of these wireless technologies through an experimental evaluation of their performance. This report investigates interactions encompassing variables such as transmission power level, distance between the devices, data rates, and the utilization of co-channel or adjacent channels. The results show that the operation of both Zigbee and Bluetooth is severely compromised when coexisting with Wi-Fi within the same frequency spectrum. On the other hand, the performance of Bluetooth is not impaired by Zigbee and vice versa unless there exists any external interference from Wi-Fi.

2.4 GHz↗

Role of p-GaN layer thickness in the degradation of InGaN-GaN MQW solar cells under 405 nm laser excitation

GaN-based solar cells with InGaN multiple quantum wells (MQWs) are promising devices for application in space environment, concentrator solar systems, wireless power transmission and multi-junction solar cells. It is therefore important to understand their degradation kinetics when submitted to high-temperature and high-intensity stress. We submitted three samples of GaN-InGaN MQW solar cells with p-AlGaN electron-blocking-layer with different thickness of the p-GaN layer to constant power stress at 310 W/cm 2 , 175 °C for several hundred hours. The main degradation modes are a reduction of open-circuit voltage, short-circuit current, external quantum efficiency, power conversion efficiency and electroluminescence. In particular, we observed that a thinner p-GaN layer results in a stronger degradation observed on the cell operating parameters. The analysis of the dark I-V characteristics showed an increase in low-forward bias current and the analysis of electroluminescence showed a decrease in the electroluminescene emitted by the (forward biased) cell, as a consequence of stress. This work highlights that the cause of degradation is possibly related to a diffusion mechanism, which results in an increase of defect density in the active region. Finally, the impurities involved in the diffusion processes possibly originate from the p-side of the devices, therefore a thicker p-GaN layer reduces the amount of defects reaching the active region.

14 SOLAR ENERGY↗