Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Re-Evaluating the Current Safety Goals

The Safety Goals adopted by the US NRC consist of two qualitative safety goals (QSGs) backed up by two quantitative health objectives (QHOs). The QHOs establish risk limits for severe accidents in terms of their radiological consequences, in particular, the average individual health risks of early fatality and latent cancers from radiation exposure of members of the public living in the vicinity of a nuclear power plant. This paper is devoted to a re-examination of the coverage of the current safety goals in evaluating the actual risk posed by nuclear power plant operation. Experience of recent Level 3 PRAs suggests that given a high likelihood of evacuation of the close-in population before any release occurs, the current QHOs are satisfied by large margins. However, the experience of an actual severe accident at Fukushima showed that actual human health effects from released radiation were not the dominant consequences; there were no early fatalities and no measurable increases expected in cancer rates above the baseline rates in the Japanese population. Hence, regardless of accident probability, Fukushima-type accidents would satisfy the NRC’s health-related safety goals. However, there were very significant societal costs, in that large numbers of people were relocated for long periods. We argue that, in addition to the risks addressed in current safety goals, societal risk should also be evaluated. The paper discusses specific possibilities for a goal and an associated quantitative objective.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Statistical Testing Approach for Quantifying Software Reliability; Application to an Example System

The U.S. Nuclear Regulatory Commission (NRC) encourages the use of probabilistic risk assessment (PRA) technology in all regulatory matters, to the extent supported by the state-of-the-art in PRA methods and data. Although much has been accomplished in the area of risk-informed regulation, risk assessment for digital systems has not been fully developed. The NRC established a plan for research on digital systems to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems in the PRA's of nuclear power plants (NPPs), and, (2) incorporating digital systems in the NRC's risk-informed licensing and oversight activities. Under NRC's sponsorship, Brookhaven National Laboratory (BNL) explored approaches for addressing the failures of digital instrumentation and control (I and C) systems in the current NPP PRA framework. Specific areas investigated included PRA modeling digital hardware , development of a philosophical basis for defining software failure , and identification of desirable attributes of quantitative software reliability methods . Based on the earlier research, statistical testing is considered a promising method for quantifying software reliability. It is widely recognized that software failures are due to the triggering of pre-existing defects by the software's operational environment. Software defects can arise from errors made in user requirements or coding errors introduced during the developmental process. The software's operational environment includes factors such as the time history of digital system inputs, communication interfaces, the internal state of the digital system, and external conditions. Thus, software reliability is a function of both the number of pre-existing defects and the presence of a triggering condition caused by the manner in which the software is used. In this paper, we describe a statistical software-testing approach for quantifying software reliability and applied it to the loop-operating control system (LOCS) of an experimental loop of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The work involved collaboration between BNL and INL. The objectives of the study include: (1) Development of a statistical testing approach for estimating software failure probability on demand, the results of which are suitable for including in a probabilistic risk assessment (PRA); and, (2) Application of the approach to the LOCS to estimate its failure probability, and obtain insights into the feasibility, practicality, and usefulness of the estimation in models of digital systems for inclusion in nuclear power plants' PRAs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The NRC's SPAR Models: Current Status, Future Development, and Modeling Issues

Probabilistic risk assessments (PRAs) play an increasingly important role in the regulatory framework of the U.S. nuclear power industry. The Nuclear Regulatory Commission (NRC) relies on a set of plant-specific Standardized Plant Analysis Risk (SPAR) models to provide critical risk-based input to the regulatory process. The Significance Determination Process (SDP), Management Directive 8.3 - NRC Incident Investigation Program, Accident Sequence Precursor (ASP) and Mitigating Systems Performance Index (MSPI) programs are among the regulatory initiatives that receive significant input from the SPAR models. Other uses of the SPAR models include: Screening & Resolution of Generic Safety Issues, License Amendment reviews and Notice of Enforcement Discretion (NOEDs). This paper presents the current status of SPAR model development activities, future development objectives, and issues related to the development, verification and maintenance of the SPAR models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Fire Events Database to Support Fire PRA

Abstract: This paper provides a description of the updated and enhanced Fire Events Data Base (FEDB) developed by the Electric Power Research Institute (EPRI) in cooperation with the U.S. Nuclear Regulatory Commission (NRC). The FEDB is the principal source of fire incident operational data for use in fire PRAs. It provides a comprehensive and consolidated source of fire incident information for nuclear power plants operating in the U.S. The database classification scheme identifies important attributes of fire incidents to characterize their nature, causal factors, and severity consistent with available data. The database provides sufficient detail to delineate important plant specific attributes of the incidents to the extent practical. A significant enhancement to the updated FEDB is the reorganization and refinement of the database structure and data fields and fire characterization details added to more rigorously capture the nature and magnitude of the fire and damage to the ignition source and nearby equipment and structures

99 GENERAL AND MISCELLANEOUS↗

The Prognostic Value of TRAIL and its Death Receptors in Cervical Cancer

Purpose: Preclinical data indicate a synergistic effect on apoptosis between irradiation and recombinant human (rh) tumor necrosis factor-related apoptosis inducing ligand (TRAIL), making the TRAIL death receptors (DR) interesting drug targets. The aim of our study was to analyze the expression of DR4, DR5, and TRAIL in cervical cancer and to determine their predictive and prognostic value. Methods and Materials: Tissue microarrays were constructed from tumors of 645 cervical cancer patients treated with surgery and/or (chemo-)radiation between 1980 and 2004. DR4, DR5, and TRAIL expression in the tumor was studied by immunohistochemistry and correlated to clinicopathological variables, response to radiotherapy, and disease-specific survival. Results: Cytoplasmatic DR4, DR5, and TRAIL immunostaining were observed in cervical tumors from 99%, 88%, and 81% of the patients, respectively. In patients treated primarily with radiotherapy, TRAIL-positive tumors less frequently obtained a pathological complete response than TRAIL-negative tumors (66.3% vs. 79.0 %; in multivariate analysis: odds ratio: 2.09, p {<=}0.05). DR4, DR5, and TRAIL expression were not prognostic for disease-specific survival. Conclusions: Immunostaining for DR4, DR5, and TRAIL is frequently observed in the cytoplasm of tumor cells in cervical cancer patients. Absence of TRAIL expression was associated with a higher pathological complete response rate to radiotherapy. DR4, DR5, or TRAIL were not prognostic for disease-specific survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiovascular Morbidity After Radiotherapy or Chemoradiation in Patients With Cervical Cancer

Purpose: To evaluate the risk of cardiovascular events (CVE) in patients with cervical cancer treated with radiotherapy or chemoradiation. Methods and Materials: The incidence of CVE in patients treated between 1989 and 2002 by radiotherapy or chemoradiation was compared with a Dutch reference population. Standardized incidence ratios (SIRs) were calculated for myocardial infarction (MI), angina pectoris (AP), congestive heart failure (CHF), cerebrovascular accident (CVA) separately and for any cardiac event combined (MI, AP, and CHF). Results: In 277 patients with a median follow-up of 4.5 years (range, 0.1-17 years) and a median survival of 9.2 years, 27 cardiac events occurred. The 5-, 10-, and 15-year actuarial incidence of any cardiac event were 9, 14, and 16%, respectively. For the whole population, the SIR for MI was elevated (2.05, 95% CI: 1.12-3.43). The radiotherapy group (n = 132) was older and had more cardiovascular risk factors than the chemoradiation group (n = 145). The SIR for MI in the radiotherapy group was 2.88 (95% CI: 1.44-5.15) and in the chemoradiation group 1.00 (95% CI: 0.21-7.47). In multivariate analyses, there was no relation between treatment modality and the risk for MI. Conclusions: In this cohort of cervical cancer patients, an increased risk for developing a MI was observed. This increased risk of MI, in combination with the high prevalence of cardiovascular risk factors in cervical cancer patients, urges the need to explore strategies to reduce their risk for cardiovascular morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Cell Biological Markers in Cervical Cancer Patients Primarily Treated With (Chemo)radiation: A Systematic Review

The aim of this study was to systematically review the prognostic and predictive significance of cell biological markers in cervical cancer patients primarily treated with (chemo)radiation. A PubMed, Embase, and Cochrane literature search was performed. Studies describing a relation between a cell biological marker and survival in {>=}50 cervical cancer patients primarily treated with (chemo)radiation were selected. Study quality was assessed, and studies with a quality score of 4 or lower were excluded. Cell biological markers were clustered on biological function, and the prognostic and predictive significance of these markers was described. In total, 42 studies concerning 82 cell biological markers were included in this systematic review. In addition to cyclooxygenase-2 (COX-2) and serum squamous cell carcinoma antigen (SCC-ag) levels, markers associated with poor prognosis were involved in epidermal growth factor receptor (EGFR) signaling (EGFR and C-erbB-2) and in angiogenesis and hypoxia (carbonic anhydrase 9 and hypoxia-inducible factor-1{alpha}). Epidermal growth factor receptor and C-erbB-2 were also associated with poor response to (chemo)radiation. In conclusion, EGFR signaling is associated with poor prognosis and response to therapy in cervical cancer patients primarily treated with (chemo)radiation, whereas markers involved in angiogenesis and hypoxia, COX-2, and serum SCC-ag levels are associated with a poor prognosis. Therefore, targeting these pathways in combination with chemoradiation may improve survival in advanced-stage cervical cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fifteen-Year Radiotherapy Outcomes of the Randomized PORTEC-1 Trial for Endometrial Carcinoma

Purpose: To evaluate the very long-term results of the randomized Post Operative Radiation Therapy in Endometrial Carcinoma (PORTEC)-1 trial for patients with Stage I endometrial carcinoma (EC), focusing on the role of prognostic factors for treatment selection and the long-term risk of second cancers. Patients and Methods: The PORTEC trial (1990-1997) included 714 patients with Stage IC Grade 1-2 or Stage IB Grade 2-3 EC. After surgery, patients were randomly allocated to external-beam pelvic radiotherapy (EBRT) or no additional treatment (NAT). Analysis was by intention to treat. Results: 426 patients were alive at the date of analysis. The median follow-up time was 13.3 years. The 15-year actuarial locoregional recurrence (LRR) rates were 6% for EBRT vs. 15.5% for NAT (p < 0.0001). The 15-year overall survival was 52% vs. 60% (p = 0.14), and the failure-free survival was 50% vs. 54% (p = 0.94). For patients with high-intermediate risk criteria, the 15-year overall survival was 41% vs. 48% (p = 0.51), and the 15-year EC-related death was 14% vs. 13%. Most LRR in the NAT group were vaginal recurrences (11.0% of 15.5%). The 15-year rates of distant metastases were 9% vs. 7% (p = 0.25). Second primary cancers had been diagnosed over 15 years in 19% of all patients, 22% vs. 16% for EBRT vs. NAT (p = 0.10), with observed vs. expected ratios of 1.6 (EBRT) and 1.2 (NAT) compared with a matched population (p = NS). Multivariate analysis confirmed the prognostic significance of Grade 3 for LRR (hazard ratio [HR] 3.4, p = 0.0003) and for EC death (HR 7.3, p < 0.0001), of age >60 (HR 3.9, p = 0.002 for LRR and 2.7, p = 0.01 for EC death) and myometrial invasion >50% (HR 1.9, p = 0.03 and HR 1.9, p = 0.02). Conclusions: The 15-year outcomes of PORTEC-1 confirm the relevance of HIR criteria for treatment selection, and a trend for long-term risk of second cancers. EBRT should be avoided in patients with low- and intermediate-risk EC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noncoding deletions reveal a gene that is critical for intestinal function

Large-scale genome sequencing is poised to provide a substantial increase in the rate of discovery of disease-associated mutations, but the functional interpretation of such mutations remains challenging. Here we show that deletions of a sequence on human chromosome 16 that we term the intestine-critical region (ICR) cause intractable congenital diarrhoea in infants. Reporter assays in transgenic mice show that the ICR contains a regulatory sequence that activates transcription during the development of the gastrointestinal system. Targeted deletion of the ICR in mice caused symptoms that recapitulated the human condition. We report transcriptome analysis revealed that an unannotated open reading frame (Percc1) flanks the regulatory sequence, and the expression of this gene was lost in the developing gut of mice that lacked the ICR. Percc1-knockout mice displayed phenotypes similar to those observed upon ICR deletion in mice and patients, whereas an ICR-driven Percc1 transgene was sufficient to rescue the phenotypes found in mice that lacked the ICR. Together, our results identify a gene that is critical for intestinal function and underscore the need for targeted in vivo studies to interpret the growing number of clinical genetic findings that do not affect known protein-coding genes.

59 BASIC BIOLOGICAL SCIENCES↗

Development and validation of a mathematical model of heart rate response to fluid perturbation

Physiological closed-loop controlled (PCLC) medical devices monitor and automatically adjust the patient’s condition by using physiological variables as feedback, ideally with minimal human intervention to achieve the target levels set by a clinician. PCLC devices present a challenge when it comes to evaluating their performance, where conducting large clinical trials can be expensive. Virtual physiological patients simulated by validated mathematical models can be utilized to obtain preclinical evidence of safety and assess the performance of the PCLC medical device during normal and worst-case conditions that are unlikely to happen in a limited clinical trial. A physiological variable that plays a major role during fluid resuscitation is heart rate (HR). For in silico assessment of PCLC medical devices regarding fluid perturbation, there is currently no mathematical model of HR validated in terms of its predictive capability performance. This paper develops and validates a mathematical model of HR response using data collected from sheep subjects undergoing hemorrhage and fluid infusion. The model proved to be accurate in estimating the HR response to fluid perturbation, where averaged between 21 calibration datasets, the fitting performance showed a normalized root mean square error (NRMSE) of 7.41 ± 2.8%. The model was also evaluated in terms of model predictive capability performance via a leave-one-out procedure (21 subjects) and an independent validation dataset (6 subjects). Two different virtual cohort generation tools were used in each validation analysis. The generated envelope of virtual subjects robustly met the defined acceptance criteria, in which 95% of the testing datasets presented simulated HR patterns that were within a deviation of 50% from the observed data. In addition, out of 16000 and 18522 simulated subjects for the leave one-out and independent datasets, the model was able to generate at least one virtual subject that was close to the real subject within an error margin of 9.56 ± 3.15% and 11.1 ± 1.22% NRMSE, respectively. In conclusion, the model can generate valid virtual HR physiological responses to fluid perturbation and be incorporated into future non-clinical simulated testing setups for assessing PCLC devices intended for fluid resuscitation.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of special nuclear materials with the associate particle technique

In the frame of the French trans-governmental R and D program against chemical, biological, radiological, nuclear and explosives (CBRN-E) threats, CEA is studying the detection of Special Nuclear Materials (SNM) by neutron interrogation with fast neutrons produced by an associated particle sealed tube neutron generator. The deuterium-tritium fusion reaction produces an alpha particle and a 14 MeV neutron almost back to back, allowing tagging neutron emission both in time and direction with an alpha particle position-sensitive sensor embedded in the generator. Fission prompt neutrons and gamma rays induced by tagged neutrons which are tagged by an alpha particle are detected in coincidence with plastic scintillators. This paper presents numerical simulations performed with the MCNP-PoliMi Monte Carlo computer code and with post processing software developed with the ROOT data analysis package. False coincidences due to neutron and photon scattering between adjacent detectors (cross talk) are filtered out to increase the selectivity between nuclear and benign materials. Accidental coincidences, which are not correlated to an alpha particle, are also taken into account in the numerical model, as well as counting statistics, and the time-energy resolution of the data acquisition system. Such realistic calculations show that relevant quantities of SNM (few kg) can be distinguished from cargo and shielding materials in 10 min acquisitions. First laboratory tests of the system under development in CEA laboratories are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and characterization of amorphous Fe2.75Dy-oxide thin films demonstrating room-temperature semiconductor, magnetism, and optical transparency

Recently, amorphous/disordered oxide thin films made from Fe and lanthanides like Dy and Tb have been reported to have a rich set of magnetic, optical, and electronic properties, as well as room-temperature magneto-electric coupling with multiferroics [A. Malasi et al., Sci. Rep. 5, 18157 (2015); H. Taz et al., Sci. Rep. 6, 27869 (2016); and H. Taz et al., Sci. Rep. 10, 1–10 (2020)]. Here, we report the synthesis and detailed characterization of Fe2.75Dy-oxide thin films prepared on various substrates using electron beam co-evaporation. The structure, chemistry, electric, magnetic, and optical properties were studied for the as-prepared and annealed (373 K, in air, 1 h) films of thickness 40 nm. High resolution transmission electron microscopy and electron diffraction study showed that the films were amorphous in both the as-prepared and annealed states. The electron energy-loss spectroscopy studies quantified that metal oxygen stoichiometry changed from Fe2.75Dy-O1.5 to Fe2.75Dy-O1.7 upon annealing. Synchrotron-based x-ray absorption spectroscopy investigation confirmed that the as-prepared films were highly disordered with predominantly metallic Fe and Dy states that became slightly oxidized with annealing in air. The as-prepared amorphous films demonstrated significantly high value of ordinary (∼10 cm2/V s) and anomalous (∼102 cm2/V s) Hall mobility and high electrical conductivity of ∼103 S/cm at room temperature. The cryogenic magnetic property measurement shows two-step magnetization below 200 K, suggesting exchange-spring magnetic interaction. The nature of the field cooled and zero-field cooled curves suggested a spin-glass like transition between 78 K and 80 K, with a characteristic broad peak. The Tauc plot analysis from optical transmission spectra confirms the existence of an optical bandgap of ∼2.42 eV that increased slightly to ∼2.48 eV upon annealing. This rich set of transport, optical, and magnetic properties in these thin films is very exciting and points to potential applicability in low-cost multifunctional devices requiring a combination of transparent, semiconducting, and magnetic responses, such as in spintronics.

Prasad Koirala, Krishna (ORCID:000000029137917X)↗

Applicability Analysis of Validation Evidence for Biomedical Computational Models

Computational modeling has the potential to revolutionize medicine the way it transformed engineering. However, despite decades of work, there has only been limited progress to successfully translate modeling research to patient care. One major difficulty which often occurs with biomedical computational models is an inability to perform validation in a setting that closely resembles how the model will be used. For example, for a biomedical model that makes in vivo clinically relevant predictions, direct validation of predictions may be impossible for ethical, technological, or financial reasons. Unavoidable limitations inherent to the validation process lead to challenges in evaluating the credibility of biomedical model predictions. Therefore, when evaluating biomedical models, it is critical to rigorously assess applicability, that is, the relevance of the computational model, and its validation evidence to the proposed context of use (COU). However, there are no well-established methods for assessing applicability. In this paper, we present a novel framework for performing applicability analysis and demonstrate its use with a medical device computational model. The framework provides a systematic, step-by-step method for breaking down the broad question of applicability into a series of focused questions, which may be addressed using supporting evidence and subject matter expertise. The framework can be used for model justification, model assessment, and validation planning. While motivated by biomedical models, it is relevant to a broad range of disciplines and underlying physics. Finally, the proposed applicability framework could help overcome some of the barriers inherent to validation of, and aid clinical implementation of, biomedical models.

97 MATHEMATICS AND COMPUTING↗

Assessing the reliability of medical resource demand models in the context of COVID-19

Abstract Background Numerous medical resource demand models have been created as tools for governments or hospitals, aiming to predict the need for crucial resources like ventilators, hospital beds, personal protective equipment (PPE), and diagnostic kits during crises such as the COVID-19 pandemic. However, the reliability of these demand models remains uncertain. Methods Demand models typically consist of two main components: hospital use epidemiological models that predict hospitalizations or daily admissions, and a demand calculator that translates the outputs of the epidemiological model into predictions for resource usage. We conducted separate analyses to evaluate each of these components. In the first analysis, we validated various hospital use epidemiological models using a recent validation framework designed for epidemiological models. This allowed us to quantify the accuracy of the models in predicting critical aspects such as the date and magnitude of local COVID-19 peaks, among other factors. In the second analysis, we evaluated a range of demand calculators for ventilators, medical gowns, and COVID-19 test kits. To achieve this, we decoupled these demand calculators from the underlying epidemiological models and provided ground truth data for their inputs. This approach enabled a direct comparison of the demand calculators, comparing them against each other and actual usage data when available. The code is available athttps://doi.org/10.5281/zenodo.13712387. Results Performance varied greatly across the epidemiological models, with greater variability in COVID-19 hospital use predictions than for COVID-19 deaths as analyzed previously. Some models did not have any peaks. Among those that did, the models under-estimated date of peak approximately as often as they over-estimated, but were more likely to under-estimate magnitude of peak, with typical relative errors around 50%. Regarding demand calculator predictions, there was significant variability, including five-fold differences in predictions for gown models. Validation against actual or surrogate usage data illustrated the potential value of demand models while demonstrating their limitations. Conclusions The emerging field of demand modeling holds promise in averting medical resource shortages during future public health emergencies. However, achieving this potential necessitates focused efforts on standardization, transparency, and rigorous model validation before placing reliance on demand models in critical public health decision-making.

Medical Informatics↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

Solar and Storage Integration in the U.S. Southeast: Implications for Resource Adequacy [Slides]

In this study, we evaluate how an iterative portfolio approach compares to a more traditional capacity credit method, using the U.S. Southeast as a case study region. Using open-source planning and resource adequacy tools, we compare results using a capacity credit approximation method with those from iterating behind the two. We also explore how the iterative approach performs under a range of sensitivities, including higher load growth, regional coordination, and alternative weather years. We find that traditional capacity credit approximation methods can function well in today's system, but may face challenges for systems with higher levels of solar and storage. As such, integrating planning and resource adequacy models can address some of these gaps, helping planners deliver more reliable systems.

14 SOLAR ENERGY↗