Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE PULSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

N 2 vibrational excitation in atmospheric pressure ns pulse and RF plasma jets

Time-resolved N 2 vibrational temperature and translational–rotational temperature in quasi-two-dimensional atmospheric pressure plasma jets sustained by ns pulse and RF discharges in nitrogen/noble gas mixtures are measured by the broadband vibrational Coherent Anti-Stokes Raman Scattering (CARS) . The results indicate a much stronger vibrational excitation in the RF plasma jet, due to the lower reduced electric field and higher discharge power. In a ns pulse discharge in N 2 /He, N 2 vibrational temperature is significantly lower compared to that in N 2 /Ar, due to the more rapid vibration–translation (V–T) relaxation of nitrogen by helium atoms. In the RF plasma jets in N 2 /Ne and N 2 /Ar, the vibrational excitation increases considerably as the nitrogen fraction in the mixture is reduced. The experimental data in the RF plasma jet in N 2 /Ar jet are compared with the kinetic modeling predictions. The results indicate that nitrogen vibrational excitation in N 2 /Ar plasma jets with a small N 2 fraction in the mixture (several percent) is controlled primarily by electron impact, anharmonic vibration–vibration (V–V) pumping, and V–T relaxation by N atoms. In comparison, V–V energy transfer from the vibrationally excited molecules in the first excited electronic state, N 2 (A 3 Σ u + , v), which are generated primarily by the energy transfer from the metastable Ar atoms, has a minor effect on the vibrational populations of the ground electronic state, N 2 (X 1 Σ g + , v). Although the discharge energy fraction going to electronic excitation is significant, the predicted quasi-steady-state N 2 (A 3 Σ u + ) number density, controlled by the energy pooling and quenching by N atoms, remains relatively low. Because of this, the net rate of N 2 (X 1 Σ g + ) vibrational excitation by the V–V energy transfer from N 2 (A 3 Σ u + ) is much lower compared to that by the direct electron impact. Furthermore, the results show that atmospheric pressure RF plasma jets can be used as sources of highly vibrationally excited N 2 molecules and N atoms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma dynamics, instabilities and OH generation in a pulsed atmospheric pressure plasma with liquid cathode: a diagnostic study

Abstract While plasma–liquid interactions have been an important focus in the plasma research community, the impact of the strong coupling between plasma and liquid on plasma properties and processes remains not fully understood. In this work, we report on the impact of the applied voltage, pulse width and liquid conductivity on the plasma morphology and the OH generation for a positive pulsed DC atmospheric pressure plasma jet with He–0.1% H 2 O mixture interacting with a liquid cathode. We adopted diagnostic techniques of fast imaging, 2D laser induced fluorescence of OH and Thomson scattering spectroscopy. We show that plasma instabilities and enhanced evaporation occur and have a significant impact on the OH generation. At elevated plasma energies, it is found that the plasma contracts due to a thermal instability through Ohmic heating and the contraction coincides with a depletion in the OH density in the core due to electron impact dissociation. For lower plasma energies, the instability is suppressed/delayed by the equivalent series resistor of the liquid electrode. An estimation of the energy flux from the plasma to the liquid shows that the energy flux of the ions released into the liquid by positive ion hydration is dominant, and significantly larger than the energy needed to evaporate sufficient amount of water to account for the measured H 2 O concentration increase near the plasma–liquid interface.

Physics↗

Short term /1 and 3 day/ cardiovascular adjustments to suspension antiorthostasis in rats

Antiorthostasis (AO) results in responses reflective of thoracic vessel loading. Initial findings included fluid and electrolyte shifts (diuresis and natriuresis) in AO but not in orthostatic (O) rats. This study aims at obtaining supportive evidence for cardiovascular responses, E.g., blood pressure and related parameters, in light of the original hypothesis. Tilting rats rapidly head-up from either horizontal (O) or head-down (AO) positions was used to assess cardiovascular sensitivities. O and AO rats were used after 1 or 3 days of suspension. Rats were controls (C), pre-tilted O and AO, tilted O and AO (rapid head-up 70-80 deg); post-tilted (to original postures). MAP in C rats was 108 +2 mmHg, in O, (117 + or - 1.02) and AO, (120 + or - 0.58). MAP, diastolic pressure (DP) and pulse pressure were consistently elevated in AO rats on day 3. With rapid head-up tilt, only MAP and DP showed significant increases. These changes were seen as cardiovascular responses to AO and support further use of this rat model for AO studies.

Musacchia, X. J.↗

Responses of heart rate and blood pressure to KC-135 hyper-gravity

Many investigators have clarified the effects of hyper gravitational-inertial forces (G) upon the cardiovascular system, using the centrifugal apparatus with short rotating radius. We investigated the cardiovascular responses to KC-135 hyper-G flight with negligibly small angular velocity. Six normal, healthy subjects 29 to 40 years old (5 males and 1 female) took part in this experiment. Hyper gravitational-inertial force was generated by the KC-135 hyper-G flight, flown in a spiral path with a very long radius of 1.5 miles. Hyper-G was sustained for 3 minutes with 1.8 +Gz in each session and was repeatedly exposed to very subject sitting on a chair 5 times. The preliminary results of blood pressure and R-R interval are discussed. An exposure of 1.8 +Gz stress resulted in a remarkable increase of systolic and diastolic blood pressure, while the pulse pressure did not change and remained equal to the control level regardless of an exposure of hyper-G. These results in blood pressure indicate an increase of resistance in the peripheral vessels, when an exposure of hyper-G was applied. The R-R interval was calculated from ECG. R-R interval in all subjects was changed but not systematically, and R-R interval became obviously shorter during the hyper-G period than during the 1 +Gz control period although R-R interval varied widely in some cases. The coefficient of variation of R-R interval was estimated to determine the autonomic nerve activity, but no significant change was detectable.

Satake, Hirotaka↗

Maximal exercise as a countermeasure to orthostatic intolerance after spaceflight

Previous investigators have suggested that maximal exercise performed 24 h before the end of bed rest, a spaceflight analog, restores prebed rest plasma volume, baroreflex responses, and orthostatic tolerance. PURPOSE: In this case report, we examined the effect of a similar exercise protocol 24 h before a Shuttle landing on the orthostatic responses of four crewmembers (EX) after spaceflights of 8-14 d. Four additional crewmembers (CON) served as controls and did not perform exercise during the final day of the flight. METHODS: Each crewmember performed a 10-min stand test approximately 10 d before launch (L-10) and within 1-2 h of landing (R+0). Cardiac stroke volume was measured (Doppler ultrasound) supine and during each min of standing for three EX and three CON subjects. RESULTS: Preflight, all crewmembers completed the stand test and each group had similar heart rate and blood pressure responses. Postflight, all subjects also completed the 10-min stand test. Each group had similarly elevated supine and standing heart rates, elevated diastolic and mean arterial blood pressures, and reduced pulse pressures compared to L-10. However, postflight cardiac output, mean +/- SEM, (EX: 4.5+/-0.6 L x min(-1); CON: 3.1+/-0.3 L x min(-1)) and stroke volume (EX: 43+/-7 mL x beat; CON: 30+/-6 mL x beat) were higher after 10 min standing in the EX subjects compared to CON subjects. CONCLUSIONS: For these four crewmembers, maximal exercise performed 24 h before landing may have helped maintain stroke volume but did not maintain heart rate and blood pressure responses during standing compared to preflight.

Flight Experiment↗

Cardiopulmonary baroreceptor control of muscle sympathetic nerve activity in heat-stressed humans

Whole body heating decreases central venous pressure (CVP) while increasing muscle sympathetic nerve activity (MSNA). In normothermia, similar decreases in CVP elevate MSNA, presumably via cardiopulmonary baroreceptor unloading. The purpose of this project was to identify whether increases in MSNA during whole body heating could be attributed to cardiopulmonary baroreceptor unloading coincident with the thermal challenge. Seven subjects were exposed to whole body heating while sublingual temperature, skin blood flow, heart rate, arterial blood pressure, and MSNA were monitored. During the heat stress, 15 ml/kg warmed saline was infused intravenously over 7-10 min to increase CVP and load the cardiopulmonary baroreceptors. We reported previously that this amount of saline was sufficient to return CVP to pre-heat stress levels. Whole body heating increased MSNA from 25 +/- 3 to 39 +/- 3 bursts/min (P < 0. 05). Central blood volume expansion via rapid saline infusion did not significantly decrease MSNA (44 +/- 4 bursts/min, P > 0.05 relative to heat stress period) and did not alter mean arterial blood pressure (MAP) or pulse pressure. To identify whether arterial baroreceptor loading decreases MSNA during heat stress, in a separate protocol MAP was elevated via steady-state infusion of phenylephrine during whole body heating. Increasing MAP from 82 +/- 3 to 93 +/- 4 mmHg (P < 0.05) caused MSNA to decrease from 36 +/- 3 to 15 +/- 4 bursts/min (P < 0.05). These data suggest that cardiopulmonary baroreceptor unloading during passive heating is not the primary mechanism resulting in elevations in MSNA. Moreover, arterial baroreceptors remain capable of modulating MSNA during heat stress.

NASA Discipline Cardiopulmonary↗

Certain cardiovascular indices predict syncope in the postural tachycardia syndrome

Patients with postural tachycardia syndrome (POTS) represent a patient population with orthostatic intolerance; some are prone to syncope, others are not. The underlying neurocardiovascular mechanisms are not completely understood. The current study was undertaken to assess if certain cardiovascular indices are predictive of syncope in POTS. We compared the response to tilt-up and the Valsalva maneuver in four groups: POTS patients who fainted (POTS-f; n = 11;31 +/- 11 years): POTS patients who did not faint (POTS-nf; n = 9; 29 +/- 9 years); normal controls (NLS; n = 13; 39 +/- 11 years); patients with generalized autonomic failure with orthostatic hypotension and syncope (n = 10; 59 +/- 14 years). Beat-to-beat heart rate (HR), systolic arterial pressure, diastolic arterial pressure (DAP) and pulse pressure (PP) were monitored using Finapres. Cardiac output, stroke volume (SV) and end-diastolic volume (EDV), and calculated total peripheral resistance (TPR) were recorded using thoracic electrical bioimpedance. An autonomic reflex screen which quantitates the distribution and severity of autonomic failure was also done. With the patient supine, all POTS patients (POTS-nf; POTS-f) had increased HR (p < 0.001) and reduced SV/EDV (p < 0.001) when compared with NLS. On tilt-up, POTS-f patients were significantly different from both NLS and POTS-nf patients; the most consistent alteration was a fall instead of an increase in TPR; other changes were a greater reduction in PP, a reduction (instead of an increment) in DAP, and a different pattern of changes during the Valsalva maneuver (excessive early phase II, attenuated or absent late phase II). Our results suggest alpha-adrenergic impairment with increased pooling or hypovolemia in POTS-f patients. We conclude that it is possible to identify the mechanism of syncope in POTS patients, and perhaps other patients with orthostatic intolerance and an excessive liability to syncope.

NASA Discipline Number 14-10↗

Passive fetal monitoring sensor

An ambulatory, passive sensor for use in a fetal monitoring system is discussed. The invention is comprised of a piezoelectric polymer film, combined with a metallic mounting plate fastened to a belt, and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted by a fetus inside an expectant mother. Additionally, the monitor will filter out pressure pulses arising from other sources, such as the maternal heart.

Zuckerwar, Allan J.↗

Energy storage and dissipation in the magnetotail during substorms. I - Particle simulations. II - MHD simulations

2D electromagnetic particle simulations are used to investigate the dynamics of the tail during development of substorms under the influence of the pressure in the magnetospheric boundary layer and the dawn-to-dusk electric field. It is shown that pressure pulses result in thinning of the tail current sheet as the magnetic field becomes pinched near the region where the pressure pulse is applied. The pinching leads to the tailward flow of the current sheet plasma and the eventual formation and injection of a plasmoid. Surges in the dawn-to-dusk electric field cause plasma on the flanks to convect into the center of the current sheet, thereby thinning the current sheet. The pressure in the magnetospheric boundary laser is coupled to the dawn-to-dusk electric field through the conductivity of the tail. Changes in the predicted evolution of the magnetosphere during substorms due to changes in the resistivity are investigated under the assumption that MHD theory provides a suitable representation of the global or large-scale evolution of the magnetotail to changes in the solar wind and to reconnection at the dayside magnetopause. It is shown that the overall evolution of the magnetosphere is about the same for three different resistivity distributions with plasmoid formation and ejection in each case.

Winglee, R. M.↗

Ionospheric response to the CME Passage of September 24,1998

On September 24, 1998, a solar coronal mass ejection struck the Earth's magnetosphere. The magnetosphere/ionosphere system exhibited a response in several ways one of which was an increase in ion outflow from the ionosphere, ionospheric mass ejections in response to the pressure pulse from the shock passage at the front of the magnetosphere. However, the timing of the incidence of the pressure pulse and the ionospheric response has not been examined in detail. Images from the Ultraviolet Imager show a brightening in the dayside aurora at the same time the shock is seen at Polar at about 23:45 UT on the 24th. . We examine the temporal and spatial relationship (using simple models ) of these two events to determine the correlation of the particles seen at Polar and the regions of increased energy input seen in the aurora and discuss the physical implications of the results.

Craven, Paul D↗

Rat Cardiovascular Responses to Whole Body Suspension: Head-down and Non-Head-Down Tilt

The rat whole body suspension technique mimics responses seen during exposure to microgravity and was evaluated as a model for cardiovascular responses with two series of experiments. In one series, changes were monitored in chronically catheterized rats during 7 days of Head-Down Tilt (HDT) or Non-Head-Down Tilt (N-HDT) and after several hours of recovery. Elevations of mean arterial (MAP), systolic, and diastolic pressures of approx. 20 % (P less than 0.05) in HDT rats began as early as day 1 and were maintained for the duration of suspension. Pulse pressures were relatively unaffected, but heart rates were elevated approx. 10 %. During postsuspension (2-7 h), most cardiovascular parameters returned to presuspension levels. N-HDT rats exhibited elevations chiefly on days 3 and 7. In the second series, blood pressure was monitored in 1- and 3-day HDT and N-HDT rats to evaluate responses to rapid head-up tilt. MAP, systolic and diastolic pressures, and HR were elevated (P less than 0.05) in HDT and N-HDT rats during head-up tilt after 1 day of suspension, while pulse pressures remained un changed. HDT rats exhibited elevated pretilt MAP and failed to respond to rapid head-up tilt with further increase of MAP on day 3, indicating some degree of deconditioning. The whole body suspended rat may be useful as a model to better understand responses of rats exposed to microgravity.

Musacchia, X. J.↗

The nonlinear transient response of thin, rectangular elastic plates

The results of experiments and theoretical analysis of the nonlinear, transient response of thin, rectangular, elastic, simply supported plates are presented. In the experiments, a plane wave tube with a special pulse generator at one end and a thin glass plate mounted at the other end was used to subject the glass plate to pressure pulses of different magnitudes. Whole-field measurements of the response of the plate were obtained by the reflected moire grid technique. The largest ratio of center deflection to thickness of the plate during the experiments was 5.6. The theoretical response of the glass plate to the pressure pulses was computed by solving the von Karman equations governing large deflections in elastic plates by two methods - (1) the finite-difference method, and (2) Galerkin's method. Good agreement was found between theoretically predicted and experimentally measured response.

Rajagopal, G.↗

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Abstract In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10 −12 to 3.2 × 10 −7 m 2 /s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term

Guglielmi, Yves↗

Simulations of effects of fiber rigidity on wet press

A previously developed lattice-Boltzmann lattice-spring method is applied to simulate a wet press process. In simulations, multi-individual flexible fibers are settled on a wire screen by the force of gravity, and a fiber network is formed on the top surface of the wire screen. Next, the coordinates and velocities of fluid and fiber solid particles are copied to a computer press simulator composed of two perforated plates. A pressure pulse is imposed at the fluid contact line of the two press plates. Water is squeezed out of the fiber network by the pressure. Finally, during simulations, fiber rigidity, fiber concentrations, and pressure pulses are varied and their effects on water removal and re-wet phenomena are systematically studied.

42 ENGINEERING↗

Solar wind dynamic pressure variations and possible ground signatures of flux transfer events

The effects of a series of solar wind dynamic pressure pulses are followed through the solar wind, across the bow shock and magnetosheath, into the magnetosphere, and down to the dayside ionosphere. Each pressure pulse had an intrinsic solar wind origin, i.e., was not generated by processes occurring at the earth's bow shock. Both upstream and downstream of the earth's bow shock, the pulses were identified by depressed magnetic field strengths and enhanced plasma densities. The pulses compressed the magnetosheath and magnetosphere, causing satellites in the magnetosphere to briefly observe enhanced magnetic field strengths, and/or enter the low-latitude boundary layer or magnetosheath. Satellites already in the magnetosheath observed a brief burst of enhanced magnetosheath flow caused by the relative inward motion of magnetosheath flow patterns. Alfven and fast mode compressional waves propagated rapidly down to the polar ionosphere, where they produced transient ionospheric flows at latitudes equatorward of the convection reversal boundary. The flow patterns moved westward around the auroral oval.

Sibeck, D. G.↗

'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

NASA Discipline Cardiopulmonary↗