Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE AMPLITUDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Low-power integrated-circuit driver for ferrite-memory word lines

Composite circuit uses both n-p-n bipolar and p-channel MOS transistors /BIMOS/. The BIMOS driver provides 1/ ease of integrated circuit construction, 2/ low standby power consumption, 3/ bidirectional current pulses, and 4/ current-pulse amplitudes and rise times independent of active device parameters.

Katz, S.↗

Miniature biotelemeter gives multichannel wideband biomedical data

A miniature biotelemeter was developed for sensing and transmitting multiple channels of biomedical data over a radio link. The design of this miniature, 10-channel, wideband (5 kHz/channel), pulse amplitude modulation/ frequency modulation biotelemeter takes advantage of modern device technology (e.g., integrated circuit operational amplifiers, complementary symmetry/metal oxide semiconductor logic, and solid state switches) and hybrid packaging techniques. The telemeter is being used to monitor 10 channels of neuron firings from specific regions of the brain in rats implanted with chronic electrodes. Design, fabrication, and testing of an engineering model biotelemeter are described.

Carraway, J. B.↗

A successive overrelaxation iterative technique for an adaptive equalizer

An adaptive strategy for the equalization of pulse-amplitude-modulated signals in the presence of intersymbol interference and additive noise is reported. The successive overrelaxation iterative technique is used as the algorithm for the iterative adjustment of the equalizer coefficents during a training period for the minimization of the mean square error. With 2-cyclic and nonnegative Jacobi matrices substantial improvement is demonstrated in the rate of convergence over the commonly used gradient techniques. The Jacobi theorems are also extended to nonpositive Jacobi matrices. Numerical examples strongly indicate that the improvements obtained for the special cases are possible for general channel characteristics. The technique is analytically demonstrated to decrease the mean square error at each iteration for a large range of parameter values for light or moderate intersymbol interference and for small intervals for general channels. Analytically, convergence of the relaxation algorithm was proven in a noisy environment and the coefficient variance was demonstrated to be bounded.

Kosovych, O. S.↗

High efficiency ground data transmission

It is demonstrated that state-of-the-art communications technology can be implemented and reliably operated on a global basis to increase the transmission rates and efficiencies on circuits with bandwidths greater than the typical speech channel. Optimization is affected by optimum clock recovery procedures, multilevel pulse amplitude modulation, single sideband amplitude modulation, transversal filter equalizers, data scrambling, and active compensation for phase instability.

Dickinson, W. B.↗

Plastic scintillation counters with an area of 2 sq m

Two designs of plastic scintillation counters with an area of 2 sq m scanned in each case by a single photomultiplier of the FEU-49 type are described. The radial dependence of their light collection at the place of the path of the detected particle does not exceed 10% while the half width of the differential distribution of the pulse amplitudes from nonfiltered cosmic radiation at sea level is 90 to 95%, and 65%, the plastic thickness being 5 cm and 10 cm, respectively. The temperature coefficient of the counter is 0.32% per 1 C.

Yegorov, T. A.↗

Evaluation of the amperex 56 TVP photomultiplier

Characteristics were measured for the Amperex 56 TVP 42 mm-diameter photomultiplier. Some typical photomultiplier characteristics-such as gain, dark current, transit and rise times-are compared with data provided. Photomultiplier characteristics generally not available such as the single photoelectron time spread, the relative collection efficiency, the relative anode pulse amplitude as a function of the voltage between the photocathode and focusing electrode, and the position of the photocathode sensing area were measured and are discussed for two 56 TVP's. The single photoelectron time spread, the relative collection efficiency, and the transit time difference as a function of the voltage between photocathode and focusing electrode were also measured and are discussed, particularly with respect to the optimization of photomultiplier operating conditions for timing applications.

Lo, C. C.↗

Studies in astronomical time series analysis. I - Modeling random processes in the time domain

Several random process models in the time domain are defined and discussed. Attention is given to the moving average model, the autoregressive model, and relationships between and combinations of these models. Consideration is then given to methods for investigating pulse structure, procedures of model construction, computational methods, and numerical experiments. A FORTRAN algorithm of time series analysis has been developed which is relatively stable numerically. Results of test cases are given to study the effect of adding noise and of different distributions for the pulse amplitudes. A preliminary analysis of the light curve of the quasar 3C 272 is considered as an example.

Scargle, J. D.↗

Synchronization for Optical PPM Signals

Method based on statistical properties of weak pulse-positionmodulated (PPM) signal enables synchronization of receiver clock with received-signal time base. Method applies to weak optical M-ary PPM signals, for which there is only one pulse of length Tp transmitted during one of timeslots of length T in each successive interval of M timeslots. Method requires small dead time, Td, at beginning and end of each timeslot, during which pulse amplitude is zero.

Vilnrotter, V. A.↗

Transient vibration test criteria for spacecraft hardware

Transient vibration test criteria, developed for spacecraft hardware, provide a test rationale to verify the capability of the hardware to withstand the low and mid frequency transient vibration environments induced by launch vehicle events. A test method, consisting of a series of discrete frequency, limited cycle, modulated sine wave pulses, was developed to avoid the slow swept sine drawbacks, yet provide a repeatable test that would excite all frequencies. The shape of the waveform is that of the classic response of the mass of a one degree of freedom system when it is base-excited by an exponentially decayed sine wave transient. Criteria were developed to define pulse amplitudes, shapes, and center frequencies from spacecraft loads analyses. Test tolerance criteria were also developed and specified. The transient vibration test criteria were implemented on spacecraft flight hardware and provided a more realistic test simulation (i.e., less conservative) for qualification of spacecraft hardware without risk of undertest.

Kern, D. L.↗

Radiation effects induced in pin photodiodes by 40- and 85-MeV protons

PIN photodiodes were bombarded with 40- and 85-MeV protons to a fluence of 1.5 x 10 to the 11th power p/sq cm, and the resulting change in spectral response in the near infrared was determined. The photocurrent, dark current and pulse amplitude were measured as a function of proton fluence. Changes in these three measured properties are discussed in terms of changes in the diode's spectral response, minority carrier diffusion length and depletion width. A simple model of induced radiation effects is presented which is in good agreement with the experimental results. The model assumes that incident protons produce charged defects within the depletion region simulating donor type impurities.

Becher, J.↗

Sub-Optimal Control of Nonlinear Flexible Space Structures

A simple yet effective method is presented for the on-line vibration control of nonlinear distributed parameter systems, with constant or time-varying properties, responding to a wide class of dynamic environments. The control procedure uses pulse generators located at selected positions throughout a given system. The degree of system oscillation near each controller determines the controller's activation time and pulse amplitude. The direct method of Liapunov is used to establish that the response of the controlled nonlinear system is Lagrange stable. Analytical and experimental studies of a wing-like plate demonstrate the feasibility, reliability, and robustness of the proposed vibration-suppression method.

Dehghanyar, T. J.↗

Cosmic-ray backgrounds in infrared bolometers

Model calculations for the production of cosmic ray events in IR detectors by energy impulses due to fast charged particles' ionization trails are presently compared to the pulse-amplitude spectrum observed from a balloon at an altitude of 38 km. The results are pertinent to the current understanding of cosmic ray backgrounds found in all high sensitivity bolometer applications. The observed signal transients are in all details consistent with the modeling of known cosmic charged particle flux characteristics and with the detector response. Generally, the optics design should minimize detector/substrate cross section.

Nolt, I. G.↗

Photoelectronic Monitor of Motion Sickness

Instrument includes gallium arsenide light-emitting diode (LED) and silicon phototransistor with infrared filter, all cast in single plastic housing. Housing attached to subject's face with transparent doublesided adhesive tape. LED directs pulses of infrared light to skin, which reflects them to phototransistor. Phototransistor produces signal that is processed by external circuits to yield plot of infrared reflectance with time. External circuits temperature-compensated and respond only to pulsed component of detector output, rejecting those components caused by stray light. Circuits also extract blood-volume pulse amplitude and heart rate.

Oman, C. M.↗

PIN photodiodes irradiated with 40- and 85-MeV protons

PIN photodiodes were bombarded with 40- and 85-MeV protons to a fluence of 1.5 x 10 to the 11th p/sq cm, and the resulting change in spectral response in the near infrared was determined. The photocurrent, dark current, and pulse amplitude were measured as a function of proton fluence. Changes in these three measured properties are discussed in terms of changes in the diode's spectral response, minority carrier diffusion length, and depletion width. A simple model of induced radiation effects is presented which is in good agreement with the experimental results. The model assumes that incident protons produce charged defects within the depletion region simulating donor type impurities.

Reft, C. S.↗

Rapid variability of P Cygni lines in massive X-ray binaries

In early-type X-ray binaries, the recombination time scales for ions such as C IV, Si IV, and N V in the stellar winds of their massive OB companion stars can be very short compared to typical X-ray pulsation or fluctuation time scales. Thus, the authors predict that the 'bleached zones', in which these ions are removed from the stellar wind by X-ray photoionization, will track the X-ray beam as it rotates and that the P Cygni line profiles due to these ions will pulsate. With the IUE satellite the authors obtained low-resolution UV spectra of the binary X-ray system HD 77581/4U 0900-40 resolved into six phase bins of the 283 s pulse period; the observed upper limit to the pulse amplitude of the equivalent width of C IV 1550 A was less than the predicted value. However, the pulsations should be easy to observe with the Hubble Space Telescope.

Kallman, Timothy R.↗

A lower bound on the minimum Euclidean distance of trellis-coded modulation schemes

A lower bound on the minimum free Euclidean distance of trellis-coded modulation (TCM) is derived that guarantees the existence of good TCM codes of any complexity. The bound is used to compare trellis codes combined with phase-shift keying, pulse amplitude modulation, and quadrature amplitude-shift keying modulation. This random coding bound is the first lower bound on the free distance of trellis codes, is tighter than any upper bound for large constraint lengths, and predicts the asymptotic performance of TCM when the complexity of the code becomes large. The bound can be used with any code rate and any modulation scheme and shows that the free distance increases linearly with the constraint length for large values of the constraint length.

Rouanne, Marc↗