Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Custom Turnkey Time and Frequency Systems: A structured, expandable approach

Radiocode Clocks Ltd. have developed a Turnkey Time and Frequency Generation and Distribution, System strategy based upon a bus of three, 'core' signals from which any Time code, Pulse rate or Frequency can be produced. The heart of the system is a ruggedized 19 inch, 3U Single Eurocard chassis constructed from machined 10mm aluminum alloy plate and designed to meet stringent Military, Security and Telecommunications specifications. The chassis is fitted with an advanced multilayer backplane with separate ground planes for analog and digital signals ensuring no degradation of low noise frequency references in the proximity of high speed digital pulse transmissions. The system has been designed to be used in three possible configurations: 1) As a stand alone generation and distribution instrument; 2) As a primary distribution unit in a turnkey Time and Frequency system; and 3) As a secondary distribution unit at a remote location from the Turnkey Time and Frequency System providing regeneration of core signals and correction for transmission delays. When configured as a secondary distribution unit the system will continue to provide usable outputs when one, two or even all three of the 'core' signals are lost. The instrument's placement within a system as a possible single point of system failure has required the development of very high reliability translator, synthesizer, phase locked loop and distribution modules together with a comprehensive alarm and monitoring strategy.

Wright, David F.↗

Methods of Achieving and Maintaining Physical Fitness for Prolonged Space Flight

This final summary report covers the five experiments that were conducted over a 24-month period beginning May 1, 1967 and ending April 30, 1969. Experiment I revealed that running and riding a bicycle ergometer produced similar gains in physical fitness variables. In Experiment I the subjects exercising at a 180 heart rate made a greater improvement in physical fitness than did those exercising a t a 140 or 160 heart rate. In Experiment II the subjects who exercised sixty minutes per day made greater gains on specified components of physical fitness than did those who exercised twenty or forty minutes per day, twelve times per week made greater gains on specified components of physical fitness than did those who exercised three or six times per week. In Experiment V, it was found that subjects could maintain a moderate level of fitness by exercising at a pulse rate of 160 beats per minute for twenty-minute periods three times per week, that subjects who "overtrained" by exercising twice daily to near exhaustion increased in fitness and that those subjects who discontinued training decreased in fitness.

Olree, Harry D.↗

A Recommended New Approach on Motorization Ratio Calculations of Stepper Motors

Stepper motors are widely used on most spacecraft mechanisms requiring repeatable and reliable performance. The unique detent torque characteristics of these type of motors makes them behave differently when subjected to low duty cycle excitations where the applied driving pulses are only energized for a fraction of the pulse duration. This phenomenon is even more pronounced in discrete permanent magnet stepper motors used in the space industry. While the inherent high detent properties of discrete permanent magnets provide desirable unpowered holding performance characteristics, it results in unique behavior especially in low duty cycles. Notably, the running torque reduces quickly to the unpowered holding torque when the duty cycle is reduced. The space industry's accepted methodology of calculating the Motorization Ratio (or Torque Margin) is more applicable to systems where the power is continuously applied to the motor coils like brushless DC motors where the cogging torques are low enough not to affect the linear performance of the motors as a function of applied current. This paper summarizes the theoretical and experimental studies performed on a number of space qualified motors under different pulse rates and duty cycles. It is the intention of this paper to introduce a new approach to calculate the Motorization Ratios for discrete permanent magnet steppers under all full and partial duty cycle regimes. The recommended approach defines two distinct relationships to calculate the Motorization Ratio for 100 percent duty cycle and partial duty cycle, when the motor detent (unpowered holding torque) is the main contributor to holding position. These two computations reflect accurately the stepper motor physical behavior as a function of the command phase (ON versus OFF times of the pulses), pointing out how the torque contributors combine. Important points highlighted under this study are the torque margin computations, in particular for well characterized mechanisms. The rationale at CDR level versus TRR/TRB level will be discussed, aiming at avoiding too much conservatism for units that have extensive test and in flight heritage. A critical topic is related to the magnetic losses and how to sort out such phenomena as a function of the motor type being used. For instance, detent torque is a major contributor that has no reason to evolve during life and is not an uncontrolled torque loss.

Nalbandian, Ruben↗

Optical Flow-Field Techniques Used for Measurements in High-Speed Centrifugal Compressors

The overall performance of a centrifugal compressor depends on the performance of the impeller and diffuser as well as on the interactions occurring between these components. Accurate measurements of the flow fields in each component are needed to develop computational models that can be used in compressor design codes. These measurements must be made simultaneously over an area that covers both components so that researchers can understand the interactions occurring between the two components. Optical measurement techniques are being used at the NASA Lewis Research Center to measure the velocity fields present in both the impeller and diffuser of a 4:1 pressure ratio centrifugal compressor operating at several conditions ranging from design flow to surge. Laser Doppler Velocimetry (LDV) was used to measure the intrablade flows present in the impeller, and the results were compared with analyses obtained from two three-dimensional viscous codes. The development of a region of low throughflow velocity fluid within this high-speed impeller was examined and compared with a similar region first observed in a large low-speed centrifugal impeller at Lewis. Particle Image Velocimetry (PIV) is a relatively new technique that has been applied to measuring the diffuser flow fields. PIV can collect data rapidly in the diffuser while avoiding the light-reflection problems that are often encountered when LDV is used. The Particle Image Velocimeter employs a sheet of pulsed laser light that is introduced into the diffuser in a quasi-radial direction through an optical probe inserted near the diffuser discharge. The light sheet is positioned such that its centerline is parallel to the hub and shroud surfaces and such that it is parallel to the diffuser vane, thereby avoiding reflections from the solid surfaces. Seed particles small enough to follow the diffuser flow are introduced into the compressor at an upstream location. A high-speed charge-coupled discharge (CCD) camera is synchronized to the laser pulse rate; this allows it to capture images of seed particle position that are separated by a small increment in time. A crosscorrelation of a particle's position in two consecutive images provides an estimate of flow velocity and direction. Multiple image pairs obtained in rapid succession at a particular flow condition provide enough measurements for statistical significance. PIV provides simultaneous velocity measurements over the entire plane that is illuminated by the light sheet instead of at a single point, as is the case when LDV is used. PIV has a further advantage in that the laser light pulse can be triggered by an external source such as a high-response pressure transducer. This feature will allow PIV to synchronize flow imaging to physical phenomena such as rotating stall or stall precursor waves. We hope that this technique can be used to obtain images of the flow field during and just prior to stall.

Skoch, Gary J.↗

Counter Patent

Circuit for measuring wide range of pulse rates by utilizing high capacity counter

Baumer, W. E.↗

Inflight exercise and work tolerance, experiment M003

The response of the cardiovascular system to a known exercise workload is used as index of the general physical condition of crewmembers during long duration space flight. Day-to-day evaluations of pulse rates before and after exercise periods were not remarkable. The response of the cardiovascular system to a calibrated workload was relatively constant for a given individual during space flights of as many as 14 days in connection with the Gemini Program.

Dietlein, L. F.↗

Continued development of the Combined Pulsed Neutron Experiment (CPNE) for lunar and planetary surfaces

Current progress is reported on the inelastic scattering, capture, and activation gamma ray portions of the Combined Pulsed Neutron Experiment (CPNE). Experiments are described which have enabled a reduction in weight of the experimental probe to 7.3 kg. Parametric studies are described which enabled the optimization of experimental parameters (e.g., gate time settings, neutron pulse rate, etc.). Estimated detection sensitivities using this light weight probe and the optimized experimental parameters are discussed.

Mandler, J. W.↗

Cardiac arrhythmias during exercise testing in healthy men.

Clinically healthy male executives who participate in a long-term physical conditioning program have demonstrated cardiac arrhythmia during and after periodic ergometric testing at submaximal and maximal levels. In 1,385 tests on 248 subjects, it was found that 34% of subjects demonstrated an arrhythmia at some time and 13% of subjects developed arrhythmia on more than one test. Premature systoles of ventricular origin were most common, but premature systoles of atrial origin, premature systoles of junctional origin, paroxysmal atrial tachycardia, atrioventricular block, wandering pacemaker, and pre-excitation were also seen. Careful post-test monitoring and pulse rate regulated training sessions are suggested for such programs.

Beard, E. F.↗

High power laser apparatus and system

A high-power, continuous-wave laser was designed for use in power transmission and energy-collecting systems, and for producing incoherent light for pumping a laser material. The laser has a high repetitive pulsing rate per unit time, resulting in a high-power density beam. The laser is composed of xenon flash tubes powered by fast-charging capacitors flashed in succession by a high-speed motor connected to an automobile-type distributor.

Evans, J. C., Jr.↗

Effects of ionizing radiation on CCD's

The effects of 1.2 MeV gamma radiation and 20 MeV electrons on the operational characteristics of CCDs are studied. The effects of ionizing radiation on the charge transfer efficiency, dark current, and input/output circuitry are described. The improved radiation hardness of buried channel CCDs is compared to surface channel results. Both ion implanted and epitaxial layer buried channel device results are included. The advantages of using a single thickness SiO2 gate dielectric are described. The threshold voltage shifts and surface state density changes of dry, steam, and HCl doped oxides are discussed. Recent results on the recovery times and total dose effects of high dose rate pulses of 20 MeV electrons are reported.

Hartsell, G. A.↗

A new flight test data system for NASA aeronautical flight research

The airborne integrated flight test data system (AIFTDS) is described. This system integrates an airborne digital computer with a high-bit-rate pulse code modulation system. Its design was influenced by in-house technical experience with similar modules and by the multiproject environment in which it was expected to operate. The present work describes events leading to the development of the system, reviews factors that influenced the objectives for the system and the resulting design, and describes the elements themselves. Block diagrams supplement the text.

Sanderson, K. C.↗

Outlook for metal lasers

Lasers utilizing atomic metallic vapors are considered with emphasis on a double discharge technique and multiply pulsed experiments. Data are presented on the effect of time delay after the first electrical discharge and the effect of lasant temperature along with results of absorption measurements utilizing a 13 mm diameter laser tube. Data obtained from multiply pulsed experiments for discharge diameters varying from 1 to 4 cm indicate that the efficiency increases with the pulsing rate.

Russell, G. R.↗

Study of optimal training protocols and devices for developing and maintaining physical fitness in females prior to and during space flight

Pedalling a bicycle at least ten minutes a day at 85% of maximum pulse rate, three days a week for ten weeks will produce moderate increases in overall strength and physical work capacity in college-age females. The longer the training session, up to thirty minutes per session, the greater are the increases in physical work capacity that result when college-age females are trained three days a week for ten weeks at 85% of their maximum heart rate.

Olree, H. D.↗