Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

What Is a Polyolefin? A Critical Overview of Ethylene Copolymers Used as Solar Photovoltaic Module Encapsulants

In recent years, photovoltaic (PV) encapsulant films marketed as polyolefins (POs), more specifically as PO elastomers (POEs) and thermoplastic POs (TPOs), have gained significant market share and are projected to become the dominant encapsulation films by 2030. Relative to other industries, there are significant misconceptions about the term PO in the PV industry. Both in the scientific literature as well as in sales and advertising, the terms PO, POE, and TPO are often misused to describe the same type of material with comparable properties, while in reality these may each consist of separate material classes. This paper provides a comprehensive literature and market review, to showcase a broad range of PO and other ethylene copolymer encapsulants from recent studies, and discusses the materials' properties to clarify what constitutes a “polyolefin.” In addition, to promote a clearer comparison of encapsulant properties, we propose a two‐dimensional taxonomy to categorize polymers used in module manufacturing, including POs. In terms of improving the reliability of solar PV modules, PO‐based encapsulants have several advantages (including lower water uptake and ion diffusion), but might come with disadvantages too, such as a more complex processing and a higher sensitivity to the storage conditions and shelf life. All this might prospectively impact adhesion properties of the encapsulant to other materials' interfaces (glass, cells etc.) and end‐product quality. Because the track record of field‐deployed PV modules containing PO encapsulants is also limited, we hope to contribute to better material understanding and precision in communication in PV to secure quality.

14 SOLAR ENERGY↗

Venus atmospheric circulation - Observations and implications of the thermal structure

Thermal structure data obtained by Pioneer Venus (PV) were analyzed and used to make calculations concerning cyclostrophic circulation around Venus. These indicate a balanced zonal (east to west) circulation, with midlatitude jets of peak velocities in the 110-120 m/s range, located between 50 and 40 mb in each hemisphere of the planet near 45 deg latitude. The calculations indicate breakdown of the balance conditions near the upper and lower boundaries at low latitudes. A slight asymmetry in the balanced zonal circulation arises out of an asymmetry in the thermal field. The PV radio occultation data show evidence of a direct meridional circulation that may be important in sustaining the atmospheric circulation of Venus. The value of continuous radio occultation measurements is stressed for studying shortand long-term variations of the atmospheric circulation.

Limaye, S. S.↗

Understanding PV Polymer Backsheet Degradation through X-Ray Scattering

Understanding how photovoltaic (PV) module backsheet polymers age and degrade in response to environmental stresses is important for designing polymers that can maintain their structural integrity after decades of outdoor use. X-ray scattering is a powerful technique for exploring backsheet polymer structure at the angstrom- (wide-angle, WAXS) and nanometer- (small-angle, SAXS) length-scales. We present the use of SAXS and WAXS to study pristine and aged polymer backsheets. The structural insight from these techniques can be used to compare the degradation induced by accelerated testing with the degradation seen in field-aged PV materials.

14 SOLAR ENERGY↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Nanometer-Scale Measurement of Grid Finger Electrical Conduction Pathways to Detect Series Resistance Degradation of Utility-Scale Silicon Solar Cells

Here, we report on an electrical conduction mechanism for series resistance (Rs) degradation observed in a utility-scale photovoltaic power plant by imaging the local resistance at the Ag/Si interface of the c-Si front metallization. Scanning spreading resistance microscopy imaging with nanometer (nm) scale spatial resolution revealed that the number of point or small-area electrical contacts decreased substantially in a degraded cell compared to an unaffected cell, demonstrating the root cause of Rs degradation. The decrease in electrical contacts is likely caused by a structural change - the Ag particles in contact with the Si cell (or via a nm-thickness tunneling glass layer) aggregate into bulk Ag, and a highly resistive glass frit forms a belt shape at the Ag/Si interface. This resistive belt, with a thickness of ~1 um, blocks the current conduction from the cell emitter to the Ag grid. Our microscopy results help to unravel unambiguously the degradation mechanism and demonstrate an example of the multiscale characterization approach for understanding degradation in field-weathered PV module.

14 SOLAR ENERGY↗

PV Degradation - Mounting & Temperature

Several studies have found indications that PV degradation may increase in hotter climates. We show in this paper that degradation does correlate to higher module temperatures, but that these temperatures are significantly affected by the module mounting and. The mechanisms of degradation vary with module technology and quality. Using data from different HIT module installations we were able to extract an activation energy that is consistent with hydrogen passivation layer degradation. In addition, we show that low degradation in hot climates can be achieved for Al-BSF technology if properly installed to reduce heat transfer in order to thermally decouple the modules from the roof. We also found that monofacial and bifacial PERC module degradation is in line with historical degradation rates of Al-BSF.

14 SOLAR ENERGY↗

Potential Vorticity Mixing in a Tangled Magnetic Field

A theory of potential vorticity (PV) mixing in a disordered (tangled) magnetic field is introduced. The analysis is in the context of β -plane MHD, with a special focus on the physics of momentum transport in the stably stratified, quasi-2D solar tachocline. A physical picture of mean PV evolution by vorticity advection and tilting of magnetic fields is proposed. In the case of weak field perturbations, quasi-linear theory predicts that the Reynolds and magnetic stresses balance as turbulence Alfvénizes for a larger mean magnetic field. Jet formation is explored quantitatively in the mean field–resistivity parameter space. However, since even a modest mean magnetic field leads to large magnetic perturbations for large magnetic Reynolds number, the physically relevant case is that of a strong but disordered field. We show that numerical calculations indicate that the Reynolds stress is modified well before Alfvénization—i.e., before fluid and magnetic energies balance. To understand these trends, a double-average model of PV mixing in a stochastic magnetic field is developed. Calculations indicate that mean-square fields strongly modify Reynolds stress phase coherence and also induce a magnetic drag on zonal flows. The physics of transport reduction by tangled fields is elucidated and linked to the related quench of turbulent resistivity. We propose here a physical picture of the system as a resisto-elastic medium threaded by a tangled magnetic network. Applications of the theory to momentum transport in the tachocline and other systems are discussed in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

UV + Damp Heat Induced Power Losses in Fielded Utility N-Type Si PV Modules

A recent trend in commercial PV modules is a transition to n-type silicon cells, including passivated emitter rear totally diffused (n-PERT), tunnel oxide passivated contact (TOPCon), and silicon heterojunction (SHJ). There is evidence via lab studies that some of these cells are more susceptible to UV induced degradation (UVID), yet there is a lack of confirmation that such degradation occurs in the field. Current IEC standards designed to screen for early module failures require only minimal UV exposure (15 kWh/m2 280-400 nm, ~2-3 months equivalent outdoor exposure). Here, we investigate fielded n-PERT silicon (Si) modules from a commercial utility that show power losses of ~2%/year. We present a comprehensive picture of the physics and chemistry of degradation supported by both module and cell electronic characterization (EL, PL, IV, EQE, and DLIT) and materials-level morphological and chemical analysis (SEM, EDS, XPS, FTIR, and HPLC). All sampled site modules show short circuit current (Isc) and open circuit voltage (Voc) losses when compared to unfielded spares, with the most severely degraded also having losses in fill factor (FF). We identify two different degradation modes contributing to overall power loss: (1) external quantum efficiency (EQE) measurements show losses in the blue range of the spectra, indicative of cell surface recombination losses, and (2) variations in high series resistance (Rs) at the cell level that are correlated with compositional differences in cell metallization. Using unfielded spares, we were able to reproduce Voc, Isc, and EQE losses via a minimum UV stress of 67.5 kWh/m2 (280-400 nm), 4.5x the exposure currently required in IEC 61215-2 (MQT 10). Degradation continued with additional UV dosage equivalent to the fielded modules (405 kWh/m2 total), with power loss leveling out at an average of 6.1%. Subsequent 1000 h of 85% RH/85degrees C damp heat testing showed that cells exposed to UV underwent additional severe series resistance degradation, even those without the susceptible paste composition seen in the field, whereas non-UV exposed cells saw little change. We attribute this to higher concentrations of acetic acid generated on the UV exposed area of the module, leading to degradation of the gridline/cell interface and high Rs. This study is unique in that it reproduces field observed utility scale UVID with an accelerated test and supports the need for standards development for longer UV exposure combined with other stress factors to catch materials interplay within a module package.

14 SOLAR ENERGY↗

PV Reference Cells for Outdoor Use: Comparison of First-Year Field Measurements

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as low-cost alternatives to thermopile pyranometers. But reference cell characteristics, such as directional and spectral response, fundamentally differ from pyranometers, and measurements made by the former cannot be substituted for or directly compared with the latter. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of multiple products from different manufacturers that are mounted at a fixed tilt, on a single-axis tracker, and on a dual-axis tracker. This report provides an analysis of the data collected during the first year of operation at the NREL location. An overall assessment is made by comparing the total energy measured by each instrument to the other instruments having the same orientation. These totals are calculated for three different scenarios: (1) using the factory calibration factors, (2) using the previously determined NREL Cell Lab calibration factors, and (3) using the newly determined field calibration factors derived from the recorded measurements. Because the true or correct measurement values are unknown, pair-wise comparisons are made. The results show that the difference between the highest and lowest measured energy can exceed 3% when using the factory calibration factors. Consistency among instruments improves when Cell Lab calibrations are used, and it further improves when using field calibration factors.

14 SOLAR ENERGY↗

Field‐representative evaluation of PID‐polarization in TOPCon PV modules by accelerated stress testing

Abstract Potential‐induced degradation‐polarization (PID‐p) can reduce module power, but how to project the extent to which PID‐p may occur in field conditions considering the factors of system voltage, condensed moisture, temperature, and illumination has not been clarified. Using tunnel oxide passivated contact (TOPCon) modules, this work demonstrates a method to test full‐size crystalline silicon PV modules for PID‐p to provide field‐representative results. In initial screening tests with positive or negative 1000 V electrical bias applied at 60°C for 96 h using Al foil electrodes on the glass surfaces, the module type exhibited reversible PID‐p only on the front face when the cell circuit was in negative voltage potential. No PID was detected on the rear after testing in either polarity. We then evaluated the PID‐p sensitivity on the front side under different UV irradiances while maintaining the glass surface wet to estimate real‐world susceptibility to PID‐p. The magnitude of the observed behavior was fit using a previously developed charge transfer and depletion by light model. Whereas power loss with −1000 V applied to the cell circuit at 60°C for 96 h in the dark was about 30%, testing the module front under 0.051 W·m −2 nm −1 at 340 nm UVA irradiation using fluorescent tubes, the mean degradation was only 3%. When the modules were tested in the dark for PID‐p with in situ dark current–voltage (I‐V) characterization, the thermal activation energy for degradation was 0.71 eV; for recovery in the dark, it was 0.58 eV. Whereas recovery from the degraded state at 60°C in the dark without voltage bias was 5% absolute in 38 h, rapid recovery of about 5% absolute was observed with 1000 W·s/m 2 exposure at 25°C using a flash tester.

14 SOLAR ENERGY↗

Nanomechanical and Fluorescence Characterizations of Weathered PV Module Encapsulation

Nanoindentation and fluorescence spectroscopy provide spatially resolved mechanical and chemical characterization for degradation of poly (ethylene-co-vinyl acetate) (EVA) encapsulants aged under accelerated weathering and in field deployed photovoltaic (PV) modules. For the accelerated weathering tests, two different EVA formulations in the glass/EVA/glass-laminated coupons were exposed to ultraviolet (UV) light for 180 days at three different temperatures (40, 60, and 80 °C) and UV intensities (0.4, 2.2, and 2.9 W/m2/nm at 340 nm). The fluorescence spectra and moduli were uniform through the cross section of both EVA formulations at the lowest temperature and UV intensity; however, under the highest temperature and UV intensity, the UV irradiated sides showed lower moduli and higher fluorescence compared to the opposite sides. For EVA obtained from PV modules deployed 27 years in Sacramento, CA, USA, changes in fluorescence intensity across the thickness were relatively greater than changes in modulus. On the other hand, for EVA obtained from the same type of module stored in the shed for 27 years, no fluorescence was observed, and a uniform modulus was seen through the EVA layer, but with substantially higher values than those obtained from the field-deployed modules. The different extent of changes between laboratory and field exposures suggests the importance of considering effects of temperature and UV intensity for designing a reliable accelerated testing. This study uniquely demonstrates the capability of microscale characterization using nanoindentation and fluorescence microscopy to monitor mechanical and chemical degradation of EVA encapsulants in PV modules.

14 SOLAR ENERGY↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

Field studies of PERC and Al-BSF PV module performance loss using power and I-V timeseries

We have studied the degradation of both full-sized modules and minimodules with PERC and Al-BSF cell variations in fields while considering packaging strategies. We demonstrate the implementations of data-driven tools to analyze large numbers of modules and volumes of timeseries data to obtain the performance loss and degradation pathways. This data analysis pipeline enables quantitative comparison and ranking of module variations, as well as mapping and deeper understanding of degradation mechanisms. The best performing module is a half-cell PERC, which shows a performance loss rate ( PLR ) of −0.27 ± 0.12% per annum (%/ a ) after initial losses have stabilized. Minimodule studies showed inconsistent performance rankings due to significant power loss contributions via series resistance, however, recombination losses remained stable. Overall, PERC cell variations outperform or are not distinguishable from Al-BSF cell variations.

Curran, Alan J.↗

Economic viability of photovoltaic power for development assistance applications

This paper briefly discusses the development assistance market and examines a number of specific photovoltaic (PV) development assistance field tests, including water pumping/grain grinding (Tangaye, Upper Volta), vaccine refrigerators slated for deployment in 24 countries, rural medical centers to be installed in Ecuador, Guyana, Kenya and Zimbabwe, and remote earth stations to be deployed in the near future. A comparison of levelized energy cost for diesel generators and PV systems covering a range of annual energy consumptions is also included. The analysis does not consider potential societal, environmental or political benefits associated with PV power. PV systems are shown to be competitive with diesel generators, based on life cycle cost considerations, assuming a system price of $20/W(peak), for applications having an annual energy demand of up to 6000 kilowatt-hours per year.

Bifano, W. J.↗

Ecovoltaic solar energy development can promote grassland bird communities

Ecologically informed photovoltaic (PV) developments that co-prioritize PV electricity generation with ecosystem function (‘ecovoltaics’) have emerged as a promising land sharing strategy to minimize ecological conflicts associated with PV solar energy development. While habitat-focused ecovoltaic designs can conceptually benefit biodiversity by offsetting or enhancing impacts of PV development, foundational field research is needed to examine how wildlife respond to these novel ecosystems. We conducted passive acoustic monitoring (PAM) in 2023 and 2024 at 13 solar facilities and paired control sites to investigate avian community responses to ecovoltaic facilities in the Midwestern United States. Compared to control sites (row crop agricultural fields), we found that ecovoltaic sites supported more grassland bird species throughout a 17-week monitoring period between May and September. Grassland bird communities on ecovoltaic sites were also more stable than on agricultural controls, as measured by the Jaccard dissimilarity index. We also used PAM-based weekly species occurrences in an occupancy-modelling framework to investigate the influence of PV development and other landscape variables on grassland bird occupancy. 10 out of 13 modelled grassland bird species had greater predicted occupancy probabilities (ψ) on PV sites than control sites. Synthesis and applications. Our findings suggest that properly sited and developed ecovoltaic solar facilities in human altered landscapes can improve habitat for birds and other wildlife, but further research is needed to understand which species may benefit most from these novel ecosystems.

14 SOLAR ENERGY↗

Supply Chain Cybersecurity Recommendations for Solar Photovoltaics

Solar photovoltaic (PV) cybersecurity is a growing field of research. As deployments of solar PV has increased, cyber risk has also increased. However, utility solar PV installations are not required to comply with North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) unless they meet a minimum generation threshold of 75 Megawatts (MW). Individual residential scale solar PV deployments will not meet that generation threshold and are therefore excluded from NERC CIP requirements. With most solar installations below 75MW, solar PV has been deployed with minimal oversight and highly variable cybersecurity maturity. The resources that make up the digital supply chain can include software, code, data, as well as other digital components. However as clean energy technology advances, cybersecurity threats and vulnerabilities continue to evolve and grow in sophistication. Solar PV faces a unique challenge in which it can be deployed in residential buildings and purchased by a consumer directly. This makes the supply chain of PV a unique challenge, where responsible parties for cybersecurity vary widely depending on the type of solar PV being deployed. Supply chain cybersecurity for solar PV represents a critical area for ensuring safe operations as the U.S. moves towards a clean energy future.

14 SOLAR ENERGY↗

DER Digital Supply Chain Gap Analysis

Solar photovoltaic (PV) cybersecurity is a growing field of research. As deployments of solar PV have increased, cyber risk has also increased. Utility solar PV installations, however, are not required to comply with the North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) plan unless they meet a minimum generation threshold of 75 MW. Individual residential-scale solar PV deployments will not meet that generation threshold and are therefore excluded from the NERC CIP requirements. With most solar installations less than 75 MW, solar PV has been deployed with minimal oversight and highly variable cybersecurity maturity. The resources that comprise the digital supply chain can include software, code, data, and other digital components. But as clean energy technologies advance, cybersecurity threats and vulnerabilities continue to evolve and grow in sophistication. Supply chain cybersecurity represents a critical area for ensuring safe operations as the U.S. moves toward a clean energy future.

cybersecurity↗