Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Chemical Bonding Technology: Direct Investigation of Interfacial Bonds

This is the third Flat-Plate Solar Array (FSA) Project document reporting on chemical bonding technology for terrestrial photovoltaic (PV) modules. The impetus for this work originated in the late 1970s when PV modules employing silicone encapsulation materials were undergoing delamination during outdoor exposure. At that time, manufacturers were not employing adhesion promoters and, hence, module interfaces in common with the silicone materials were only in physical contact and therefore easily prone to separation if, for example, water were to penetrate to the interfaces. Delamination with silicone materials virtually vanished when adhesion promoters, recommended by silicone manufacturers, were used. The activities related to the direct investigation of chemically bonded interfaces are described.

Koenig, J. L.↗

Technoeconomic feasibility of photovoltaic recycling

Abstract Photovoltaic (PV) modules are a key technology to aid the imminent transition from carbon‐based energy. End‐of‐life crystalline silicon PV modules produce a waste stream that is predominantly landfilled due to the recycling challenges associated with PV reuse economics. Current practices recycle the aluminum frame and repurpose the junction box but landfill the rest of the module. The primary challenge in recycling the remaining module is finding a technoeconomically viable method for separating the silicon and glass from the ethylene vinyl acetate (EVA) layers. This issue will rapidly expand with time as it is estimated that flat glass production for solar panels is currently unable to meet the demand for PV. Current literature suggests that chemical, thermal, and mechanical delamination offer economically feasible solutions under ideal circumstances. In this work we evaluate these methods using end‐of‐life panels and assess the economic viability. The technoeconomic study presented here suggests the most economically viable option for disposing of end‐of‐life solar panels, given current technology, is landfilling. Thermal delamination may offer an alternative route in the future. Financial incentives, which can be quantified with this work, may be required to kickstart PV recycling to help bridge externalities around environmental impact.

Crespo, Beatrice↗

Photovoltaic module on-orbit assembly for Space Station Freedom

One of the elements of the Space Station Freedom power system is the Photovoltaic (PV) module. These modules will be assembled on-orbit during the assembly phase of the program. These modules will be assembled either from the shuttle orbiter or from the Mobile Servicing Center (MSC). The different types of assembly operations that will be used to assemble PV Modules are described.

Sours, Thomas↗

Photovoltaic module on-orbit assembly for Space Station Freedom

One of the elements of the Space Station Freedom power system is the photovoltaic (PV) module. These modules will be assembled on-orbit during the assembly phase of the program. These modules will be assembled either from the Shuttle Orbiter or from the Mobile Servicing Center (MSC). The different types of assembly operations that will be used to assemble PV modules are described.

Sours, T.↗

Long-term photothermal/humidity testing of photovoltaic module polymer insulations and cover films

The life expectancies of Tedlar and other polymer films considered for use as cover materials in terrestrial photovoltaic (PV) modules were investigated by exposing them for more than 13,000 h on an outdoor test stand and for up to 10,000 h in several accelerated multistress environments. Visual observations and diagnostic analyses of weight and mechanical strength losses were periodically conducted to assess the nature and rate of degradation of mechanical properties and to assess the effects of film thickness and UV stabilizer content. Spectroscopic analyses of pristine and degraded materials linked weight and mechanical property losses to the underlying photothermal/photooxidation chemistry. It is shown that heavy doses of UV stabilizers prolong, while elevated temperatures shorten, the useful life of these materials; humidity plays only a minor role. The most heavily UV-stabilized films are expected to operate usefully in a PV module front-cover application for only five to ten years. The performance of none of the tested films appears consistent with the 20-30 year life goals of the PV industry.

Mon, G.↗

Tough Break: Many Factors Make Glass Breakage More Likely

We have seen cases of glass in PV modules breaking differently, and more often, than it did five years ago. There have been many changes to PV module design and materials in that time. But there is probably no single change that is responsible for the problem. Here we summarize the current thinking on PV glass breakage in utility-scale power plants. We share insights from multiple still-running projects at NREL.

14 SOLAR ENERGY↗

Electromigration in thin-film photovoltaic module metallization systems

Electromigration as a possible thin-film module failure mechanism was investigated using several specially made, fully aluminized thin-film photovoltaic (TF-PV) modules. The effect of electromigration, as determined experimentally by measuring increases in electrical resistance across scribe lines, can be expressed as the product of a damage function, which correlates degradation rate with operating conditions such as current density and temperature, and a susceptibility function, which is defined by module design parameters, particularly aluminum purity and the configuration of the intercell region. Experimental measurements and derived acceleration factors suggest that open-circuit failure resulting from electromigration should not be a serious problem in present state-of-the-art TF-PV modules. Nevertheless, significant intercell resistance increases can result from long-term electromigration exposure, especially in future high-efficiency modules. The problem can be alleviated, however, by appropriate metallization applications and/or proper design of the intercell region.

Wen, L.↗

Nature of innovations affecting photovoltaic system costs

Innovations improve technology costs through various kinds of engineering advancements, including changes to materials choices and device or process designs. Understanding how these innovations relate to cost change can reveal aspects of the process of technology evolution, yet developing such understanding is often not possible with a strictly quantitative approach due to data limitations. In this paper we develop a hybrid quantitative-qualitative framework for relating specific innovations to cost change by using the variables in a quantitative technology cost change model as an organizing principle. We demonstrate this framework by applying it to the cost decline in photovoltaic (PV) systems over the last five decades. This framework generates new understanding of a set of innovations that contributed to PV modules’ sustained cost decline and the more modest trends observed in balance-of-system (BOS) costs. The results show the great diversity of innovations that affected PV costs, drawing on wide-ranging fields of expertise within scientific research and practice. We find that there are differences in the characteristics of innovations that reduced the cost of PV modules compared to innovations influencing BOS costs. Numerous module innovations reduced costs by advancing manufacturing tools and processes that improved material quality. Many BOS innovations reduced costs through a combination of component design changes, integration, automation, digitalization, and standardization. Overall, most innovations in our sample affected PV hardware. However, some also target ‘soft technologies’ such as task durations through innovations like fast-track permitting, which require improved collaboration and process streamlining. This framework also provides insight into the nature of knowledge spillovers between technologies. Both module and BOS hardware innovations show the benefits of PV’s position within an ‘ecosystem’ of continuously advancing technologies in many industries, in particular semiconductors and electronics, and also point to the importance of public institutions for accelerating testing, permitting, and training.

14 SOLAR ENERGY↗

Lessons from the IEC Durability of Adhesion Accelerated Test Sequence

The IEC 62788-1-1 and IEC 63209-2 standards use aging sequences for durability of adhesion in photovoltaic (PV) modules, which may be evaluated using the single cantilever beam (SCB) test. Because the encapsulant forms critical interfaces with the front glass and solar cells, degradation at those interfaces under ultraviolet (UV) exposure, elevated temperature, and humidity can lead to interfacial delamination - compromising the long-term reliability. In this work, adhesion durability of UV-transmitting poly(ethylene-co-vinyl acetate) (EVA) encapsulant to glass and to silicon solar cells is evaluated after sequenced UV and damp heat aging (85C/85%RH). Laminates were prepared using StarPhire solar front glass with thin glass or PERC cells, and two EVA formulations with different concentrations of siloxane coupling agent. Adhesion was quantified by measuring critical debond energy using the SCB method. Both formulations exhibit similar qualitative trends, while different adhesion is observed at the periphery despite the use of low-shrink manufacturing. The results show that while glass/EVA adhesion remains stable or increases after UV exposure and shows only moderate changes after damp heat, the EVA/cell interface exhibits an irreversible loss of adhesion following UV and then damp heat exposure. Although glass/EVA interfaces generally exhibit lower debond energies, the EVA/cell interface is significantly more vulnerable to UV-driven degradation, identifying it as the dominant reliability risk location through early- and intermediate-module life. These results demonstrate that accelerated aging sequences can expose large, interface-specific losses in adhesion durability and underscore the importance of interface engineering for long-term PV module reliability.

14 SOLAR ENERGY↗

Evolution of integrated panel structural design and interfaces for PV power plants

The evolution of integrated photovoltaic (PV) panel design at ARCO Solar is discussed. Historically, framed PV modules of about 1 x 4-ft size were individually mounted in the field on fixed support structures and interconnected electrically with cables to build higher-power arrays. When ARCO Solar saw the opportunity in 1982 to marry its PV modules with state-of-the-art heliostat trackers developed by ARCO Power Systems, it became obvious that mounting individual modules was impractical. For this project, the framed modules were factory-assembled into panels and interconnected with cables before being mounted on the trackers. Since then, ARCO Solar made considerable progress and gained substantial experience in the design and fabrication of large PV panels. Constraints and criteria considered in these design activities included static and dynamic loads; assembly and transportation equipment and logistics, structural and electrical interfaces, and safety and grounding concerns.

Arnett, J. C.↗

Investigation of test methods, material properties, and processes for solar cell encapsulants

Photovoltaic (PV) modules consist of a string of electrically interconnected silicon solar cells capable of producing practical quantities of electrical power when exposed to sunlight. To insure high reliability and long term performance, the functional components of the solar cell module must be adequately protected from the environment by some encapsulation technique. The encapsulation system must provide mechanical support for the cells and corrosion protection for the electrical components. The goal of the program is to identify and develop encapsulation systems consistent with the PV module operating requirements of 30 year life and a target cost of $0.70 per peak watt ($70 per square meter) (1980 dollars). Assuming a module efficiency of ten percent, which is equivalent to a power output of 100 watts per square meter in midday sunlight, the capital cost of the modules may be calculated to be $70.00 per square meter. Out of this cost goal, only 20 percent is available for encapsulation due to the high cost of the cells, interconnects, and other related components. The encapsulation cost allocation may then be stated as $14.00 per square meter, included all coatings, pottant and mechanical supports for the cells.

Source record↗

Flat-plate solar array project. Volume 1: Executive summary

In 1975, the U.S. Government contracted the Jet Propulsion Lab. to develop, by 1985, in conjunction with industry, the photovoltaics (PV) module and array technology required for widespread use of photovoltaics as a significant terrestrial energy source. As a result, a project that eventually became known as the Flat Plate Solar Array (FSA) Project was formed to manage an industry, university, and Government team to perform the necessary research and development. The original goals were to achieve widespread commercial use of PV modules and arrays through the development of technology that would allow them to be profitably sold for $1.07/peak watts (1985 dollars). A 10% module conversion efficiency and a 20 year lifetime were also goals. It is intended that the executive summary provide the means by which one can gain a perspective on 11 years of terrestrial photovoltaic research and development conducted by the FSA Project.

Callaghan, W.↗

Solar Photovoltaics Resilient Fasteners Levelized Cost of Energy (LCOE) Tool

Solar photovoltaics (PV) module fasteners are one of the most common structural failure points on PV systems, particularly in high winds and coastal areas with ocean spray. Some fastener types have been shown to survive these conditions at higher rates than others. The fastener type, material, quantity, and placement all impact performance. Fasteners that fail less often typically have a higher upfront cost, but this investment can pay off in savings from less frequent torque audits (which reduces O&M costs), reduced system damage, and decreased system downtime. We developed an Excel-based tool to evaluate different module fasteners for a PV system - either a new or retrofit project - and compare differences in upfront and outyear costs to determine the expected life cycle costs and simple payback periods of different fastener options. The tool is site-specific, with inputs including system attributes (such as system size, location, price of power) and fastener attributes (such as design, washer type, nut type, use of locking hardware, materials, installation time, and torque audit requirements). A baseline fastener scenario can be compared to up to four proposed fastener scenarios. In addition to presenting expected life cycle cost implications of the different fastener options, the tool produces results showing the reductions in outyear costs needed to offset any initial cost premiums for more reliable fasteners across four categories: preventative O&M, avoided damage, reduced downtime, and reduced insurance premiums. These numbers can serve as decision aids for users when considering fastener options on new or existing projects. This poster will present the tool, methodology, and scenarios using example sites to highlight the tool capabilities and how it can inform different fastener decisions on different projects. Future work includes incorporating lifetime expected damage costs by embedding damage function curves that the authors are developing from field data.

14 SOLAR ENERGY↗

Fundamental Studies of Soiling and Cementation of PV Cover Glass Materials: Addressing Reliability with Advanced X-ray Scattering/Spectroscopy and First Principles Modeling (Final Technical Report)

Accumulation of soils and other particulate matter on the front cover glass of solar photovoltaic (PV) modules results in transmission losses that detrimentally affect the power output of PV installations. The conventional solution to this problem is manual abrasive scrubbing of modules, which entails significant water usage and manpower. To further combat this issue, there is a concerted effort within the PV industry to develop anti-soiling (AS) coatings to mitigate power losses due to soiling of PV modules, which can exceed 35% in some cases. However, relatively little is known about the fundamental physical and chemical mechanisms that enable anti-soiling behavior. In this project, a combination of advanced X-ray analysis tools and first principles computational modeling has employed to understand the physical and chemical interactions between environmental soils and PV cover glass materials. The specific objectives were: 1) investigate soiling interactions and cementation behavior of relevant PV materials, including bare glass, conventional antireflective (AR) coatings, and a commercial AS coating, using a library of representative particulate soils, and 2) utilize first principles computational spectroscopy modeling to interpret the experimental X-ray spectroscopy measurements and determine the detailed surface chemistry changes that occur on these surfaces in the presence of soiling and cementation.

14 SOLAR ENERGY↗

Leveling-Up for Big-Format Modules

Like Mario grabbing a super mushroom, PV modules just keep getting bigger! As they grow, so do the challenges of handling, installing, and testing them in the field. At NREL, we've embarked on our own New Hope - adapting to this size revolution across our tools, transportation, ergonomics, and field compatibility. Join us as we navigate this galactic expansion and keep PV testing at the cutting edge.

14 SOLAR ENERGY↗

DuraMAT FY24 Annual Report: Five Results to Help America's Photovoltaic Industry

The Durable Module Materials Consortium's overarching goal is to understand photovoltaic (PV) module degradation and enable high-energy-yield modules with a 50-year lifespan. One of DuraMAT's milestones this year was to identify cases where the whole of DuraMAT really mattered and made an impact that was greater than the sum of the project results. We identified five key results that demonstrate progress toward enabling 50-year modules for a resilient PV industry: 1) Resilient PV Systems; 2) Proactive Materials Screening; 3) Understanding Wear-Out; 4) Identifying Which Cracks Matter; and 5) Software Tools and Data Resources This annual report summarizes these key results, as well as reviewing our other ongoing work in fiscal year 2024.

14 SOLAR ENERGY↗

Ultralight amorphous silicon alloy photovoltaic modules for space applications

Ultralight and ultrathin, flexible, rollup monolithic PV modules have been developed consisting of multijunction, amorphous silicon alloys for either terrestrial or aerospace applications. The rate of progress in increasing conversion efficiency of stable multijunction and multigap PV cells indicates that arrays of these modules can be available for NASA's high power systems in the 1990's. Because of the extremely light module weight and the highly automated process of manufacture, the monolithic a-Si alloy arrays are expected to be strongly competitive with other systems for use in NASA's space station or in other large aerospace applications.

Hanak, J. J.↗

Scientific frontiers of agrivoltaic cropping systems

Agrivoltaic (AV) systems integrate agriculture with electricity conversion through photovoltaic (PV) modules. Compared with conventional ground-mounted PV systems, AV systems can reduce land-use competition and offer agronomic and economic advantages, such as more stable crop production and additional farm income. However, AV systems can decrease agricultural performance and are typically 20-90% costlier to install than conventional PV systems. Here, in this Review, we analyse the implementation of AV cropping systems to preserve agricultural activities and highlight challenges and barriers. The global electricity potential of AV systems is ~66-385 PWh annually, depending on PV technology and installation density, if deployed in the most suitable areas, without accounting for grid availability. Scaling up has been hindered by crop selection for shading conditions, decreased energy conversion per unit of land area and issues with social acceptance, landscape impact and environmental sustainability. These issues can be addressed by developments such as wavelength-selective PV; system configurations, such as optimizing module spacing to reduce shading; and operational methods, such as optimizing tracking strategies and integrating agricultural infrastructure. Cross-sector policies can support AV systems by addressing the needs of diverse stakeholders over shared land resources. Further development will require collaboration among the design, performance, deployment and systems research communities.

14 SOLAR ENERGY↗