Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Hierarchical, Grid-Aware, and Economically Optimal Coordination of Distributed Energy Resources in Realistic Distribution Systems

Renewable portfolio standards are targeting high levels of variable solar photovoltaics (PV) in electric distribution systems, which makes reliability more challenging to maintain for distribution system operators (DSOs). Distributed energy resources (DERs), including smart, connected appliances and PV inverters, represent responsive grid resources that can provide flexibility to support the DSO in actively managing their networks to facilitate reliability under extreme levels of solar PV. This flexibility can also be used to optimize system operations with respect to economic signals from wholesale energy and ancillary service markets. Here, we present a novel hierarchical scheme that actively controls behind-the-meter DERs to reliably manage each unbalanced distribution feeder and exploits the available flexibility to ensure reliable operation and economically optimizes the entire distribution network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

distribution network↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Session 3: Agrivoltaics Pathways [Slides]

This presentation was developed for a webinar series for the USAID's South Asia Group for Energy (SAGE) and South Asia Regional Energy Partnership (SAREP). The presentation includes insights into agrivoltaic site assessment planning, including what is needed for a farm assessment, solar panel system design from the agricultural perspective, variables that go into crop selection, and environmental impact, sustainability, and agritourism, technical parameters for developing an agrivoltaics project, including what makes up a PV feasibility study, understanding variables that go into technology and equipment selection, agrivoltaic installation and agricultural integration, and monitoring and maintenance throughout the life of the project, and agrivoltaic financial planning, risk mitigation, and debt equity issues.

14 SOLAR ENERGY↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows: Preprint

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 1.6% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

The Influence of Planetary Wave Transport on Arctic Ozone as Observed by POAM III

Three recent Arctic winters have been unusually warm or cold compared to the 1979-2001 mean, resulting in either a warm, disturbed vortex or a cold, quiet vortex. Interannual differences n ozone transport in the lower stratospheric Arctic vortex are investigated using data from the Polar Ozone and Aerosol Measurement (POAM) III satellite instrument obtained between May 1998 and April 2001. Time series of probability distribution functions (PDFs) of the FOAM data are used to identify seasonal and interannual variations in the transport processes controlling polar ozone. A major warming occurred in December, 1998, that caused the middle stratospheric vortex to be displaced from the pole for nearly a month and dissipate. Ozone transport is inferred from the PDFs and supported by potential vorticity (PV) analyses. The vortex reformed in January, 1999, filled with high O3 air from lower latitudes, which then cooled and descended. As a result, by the end of winter 1999, ozone at 500K in the vortex was 0.5-1.0 ppm higher than in the cold winter of 2000. The winter of 2000-1 had frequent wave disturbances, beginning with a fairly large event in November. However, at the end of this wave activity, the high PV core of the vortex was still intact, and by February, 03 in the vortex looked the same as in 2000. This study demonstrates that interannual variability in the 03-PV relationship can be caused by transport, independent of 03 loss by polar stratospheric clouds (PSCs). Ozone in the vortex in a very disturbed winter does not necessarily represent'pre-PSC' O3 levels in other years.

Strahan, Susan↗

Multi-Timescale Integrated Dynamic and Scheduling Model (MIDAS-Solar)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power system operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power systems steady-state and dynamic performance. This project helps meet and exceed the Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for electric grid planning and operation. This will be accomplished by developing temporally comprehensive, closed-loop simulation models that seamlessly simulate power systems operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). Both a multi-timescale grid model and an integrated PV model will be developed in this project to accurately study the impacts of PV variability and uncertainty on system reliability at multiple timescales. Using quasi-dynamic simulation methods and data-driven security assessment (DSA) criteria will allow the dynamic characteristics of PV to be fed forward into longer-timescale scheduling models for a complete understanding of the effect of short-term PV dynamics on bulk systems operations (e.g., reserve scheduling and deployment). Upon completion of the proposed model, this project will help operators accurately assess system reliability by deploying energy and reserve scheduling under critical contingency conditions and studying interactions among all types of essential reliability services provided by modern PV power plants.

14 SOLAR ENERGY↗

Plasma volume shifts and exercise thermoregulation with water immersion and six-degree head-down tilt

The hypothesized fluid shifts and resultant responses that occur during spaceflight are simulated by six-degree head down tilt (HDT) and water immersion (WI). The purpose of this study was to compare exercise thermoregulation before and after physiologic mechanisms reduce plasma volume (PV) in response to 24-hr HDT (HDT24). A secondary study utilized WI to reproduce the PV reduction of HDT24. Seven males were studied in two conditions: during 70 minutes of supine cycling ergometry at 58 percent of peak oxygen consumption following 1-hr HDT (HDT1) and HDT24; and up to 6 hr WI at 34.5 C. Plasma volume was reduced by 10.4 percent in HDT24 when compared to HDT1. Pre-exercise rectal temperature, T(sub re), was an average 0.22 C higher after HDT24. Rectal temperature increased during exercise with no interaction between time and treatment. The reduced PV and elevated pre-exercise T(sub re) had offsetting effects on thermoregulatory mechanisms, suggesting no alteration in the response at a given T(sub re). Plasma volume was reduced by 4.3 +/- 2.3 percent and 1.1 +/- 1.8 percent following HDT24 and WI, respectively, compared to upright chair rest. Although the reductions in PV were not significantly different, great intra-individual variability was evident. The ability to reproduce PV changes consistently with HDT and WI is limited by this variability.

Ertl, Andrew Carl↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Optimal Sizing of PV and Energy Storage in an Electric Vehicle Extreme Fast Charging Station

This paper proposes an optimization model for the optimal sizing of photovoltaic (PV) and energy storage in an electric vehicle extreme fast charging station considering the coordinated charging strategy of the electric vehicles. The proposed model minimizes the annualized cost of the extreme fast charging station, including investment and maintenance cost of PV and energy storage, cost of purchasing energy from utility and demand charge. The decision variables are capacity of invested PV and the power and energy ratings of invested energy storage. To further reduce the annualized cost of the extreme fast charging station, the charging strategy of electric vehicles are integrated into the optimization model and coordinated with the power output of PV and charging/discharging of energy storage. Results of numerical simulations indicate that investment of PV and energy storage could help reduce the annualized cost of the extreme fast charging station significantly. Meanwhile, the impacts of various parameters on the optimal solution are investigated by sensitivity analysis.

Liu, Guodong↗

Vertical Jump Height is more Strongly Associated with Velocity and Work Performed Prior to Take-off

Vertical jump (VJ) height is commonly used as a measure of athletic capability in strength and power sports. Although VJ has been shown to be a predictor of athletic performance, it is not clear which kinetic ground reaction force (GRF) variables, such as peak force (PF), peak power (PP), peak velocity (PV), total work (TW) or impulse (Imp) are the best correlates. To determine which kinetic variables (PF, PP, PV, TW, and Imp) best correlate with VJ height. Twenty subjects (14 males, 6 females) performed three maximal countermovement VJs on a force platform (Advanced Mechanical Technology, Inc., Watertown, MA, USA). VJ jump height was calculated as the difference between standing reach and the highest reach point measured using a Vertec. PF, PP, PV, TW, and Imp were calculated using the vertical GRF data sampled at 1000 Hz from the lowest point in the countermovement through the concentric portion until take-off. GRF data were normalized to body mass measured using a standard scale (Detecto, Webb City, MO, USA). Correlation coefficients were computed between each GRF variable and VJ height using a Pearson correlation. VJ height (43.4 plus or minus 9.1 cm) was significantly correlated (p less than 0.001) with PF (998 plus or minus 321 N; r=0.51), PP (1997 plus or minus 772 W; r=0.69), PV (2.66 plus or minus 0.40 m (raised dot) s(sup -1); r=0.85), TW (259 plus or minus 93.0 kJ; r=0.82), and Imp (204 plus or minus 51.1 N(raised dot)s; r=0.67). Although all variables were correlated to VJ height, PV and TW were more strongly correlated to VJ height than PF, PP, and Imp. Therefore, since TW is equal to force times displacement, the relative displacement of the center of mass along with the forces applied during the upward movement of the jump are critical determinants of VJ height. PV and TW are key determinants of VJ height, and therefore successful training programs to increase VJ height should focus on rapid movement (PV) and TW by increasing power over time rather than focusing on PF alone.

Bentley, J. R.↗

Opportunities for Hybrid Wind and Solar PV Plants in India

The share of variable renewable energy (VRE) on India's grid has surpassed 100 GW, and the government has ambitious plans reach 450 GW by 2030. One strategy to increase wind and solar PV deployment is through the co-location of wind and solar PV plants to form a single hybrid power plant. Hybrid plants have the potential to reduce transmission infrastructure costs and variability in the output power profile compared to a standalone plant with a single technology, and this resource analysis aims to take a first step towards quantifying the potential savings from hybridizing wind and solar PV plants in India and the size of this opportunity. We utilize a brute-force optimization to minimize the levelized cost of energy (LCOE) for standalone wind, standalone solar PV, and hybrid wind/solar PV plants across all of India. By comparing these LCOEs, we determine that locations where hybrid plants exhibit potential cost savings and grid benefits exhibit both; a high interconnection cost and; a wind capacity factor between roughly 34% and 38%. However, because our work does not capture the value of the electricity generated by looking at energy prices, nor does it quantify the potential of hybrids to provide other value streams such as firm capacity and reserves. Further, because the work does not compare solar PV and wind hybrids to alternative generation technologies or storage systems, it cannot be considered a holistic cost-benefit analysis.

14 SOLAR ENERGY↗

On the Path to SunShot. Emerging Issues and Challenges in Integrating High Levels of Solar into the Electrical Generation and Transmission System

This report examines how the bulk power system may need to evolve to accommodate the increased photovoltaic (PV) penetration resulting from achievement of the U.S. Department of Energy's SunShot cost targets. The variable and uncertain nature of PV-generated electricity presents grid-integration challenges. For example, the changing net load associated with high midday PV generation and low electricity demand can create 'overgeneration' that requires curtailment of PV output and reduces PV's value and cost-competitiveness. Accommodating the changes in net load resulting from increased variable generation requires enhancements to a power system's 'flexibility,' or ability to balance supply and demand over multiple time scales through options including changes in system operation, flexible generation, reserves from solar, demand response, energy storage, and enhanced transmission and regional coordination. For utility-scale PV with a baseline SunShot levelized cost of electricity (LCOE) of 6 cents/kWh, increasing the annual energy demand met by solar energy from 10% to 20% would increase the marginal LCOE of PV from 6 cents/kWh to almost 11 cents/kWh in a California grid system with limited flexibility. However, increasing system flexibility could minimize solar curtailment and keep PV cost-competitive at penetrations at least as high as 25%. In the longer term, energy storage technologies--such as concentrating solar power with thermal energy storage--could facilitate the cost-effective integration of even higher PV penetration. Efficient deployment of the grid-flexibility options needed to maintain solar's value will require various innovations, from the development of communication, control, and energy storage technologies to the implementation of new market rules and operating procedures.

14 SOLAR ENERGY↗

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Providing Ancillary Services with Photovoltaic Generation in Multi-Timescale Grid Operation: Preprint

With photovoltaic (PV) generation substantially increases, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV generation. On the one hand, the increase of PV generation necessitates the needs of more flexible resources. On the other hand, PV generation, because of its low operation cost, has been replacing the conventional generation in the system which is the main flexible resources in the current system. Consequently, there is a trend to require the renewable generation including PV to provide flexible ancillary services to further accommodate more PV integration. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. It shows that not only the system reliability but also PV's profitability can be improved with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Ecovoltaic solar energy development can promote grassland bird communities

Ecologically informed photovoltaic (PV) developments that co-prioritize PV electricity generation with ecosystem function (‘ecovoltaics’) have emerged as a promising land sharing strategy to minimize ecological conflicts associated with PV solar energy development. While habitat-focused ecovoltaic designs can conceptually benefit biodiversity by offsetting or enhancing impacts of PV development, foundational field research is needed to examine how wildlife respond to these novel ecosystems. We conducted passive acoustic monitoring (PAM) in 2023 and 2024 at 13 solar facilities and paired control sites to investigate avian community responses to ecovoltaic facilities in the Midwestern United States. Compared to control sites (row crop agricultural fields), we found that ecovoltaic sites supported more grassland bird species throughout a 17-week monitoring period between May and September. Grassland bird communities on ecovoltaic sites were also more stable than on agricultural controls, as measured by the Jaccard dissimilarity index. We also used PAM-based weekly species occurrences in an occupancy-modelling framework to investigate the influence of PV development and other landscape variables on grassland bird occupancy. 10 out of 13 modelled grassland bird species had greater predicted occupancy probabilities (ψ) on PV sites than control sites. Synthesis and applications. Our findings suggest that properly sited and developed ecovoltaic solar facilities in human altered landscapes can improve habitat for birds and other wildlife, but further research is needed to understand which species may benefit most from these novel ecosystems.

14 SOLAR ENERGY↗