Search NASA⌕ Search

SEARCH · Search NASA

Results for “PVC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A novel process for separation of polycarbonate, polyvinyl chloride and polymethyl methacrylate waste plastics by froth flotation

Highlights: • KMnO{sub 4} treatment changes selectively flotation behavior of PC, PVC and PMMA plastics. • Ternary waste plastics are separated efficiently by froth flotation. • Recycling of KMnO{sub 4} solutions is conducted to make the process green. • A novel process is proposed for separation of waste plastics by froth flotation. - Abstract: A novel process was proposed for separation of ternary waste plastics by froth flotation. Pretreatment of plastics with potassium permanganate (KMnO{sub 4}) solution was conducted to aid flotation separation of polycarbonate (PC), polyvinyl chloride (PVC) and polymethyl methacrylate (PMMA) plastics. The effect of pretreatment parameters including KMnO{sub 4} concentration, treatment time, temperature and stirring rate on flotation recovery were investigated by single factor experiments. Surface treatment with KMnO{sub 4} changes selectively the flotation behavior of PC, PVC and PMMA, enabling separation of the plastics by froth flotation. Mechanism of surface treatment was studied by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray photoelectron spectrum (XPS). Effect of frother concentration and flotation time on flotation behavior of plastic mixtures was further studied for flotation separation. The optimized conditions for separation of PC are KMnO{sub 4} concentration 2 mmol L{sup −1}, treatment time 10 min, temperature 60 °C, stirring rate 300 rpm, flotation time 1 min and frother concentration 17.5 mg L{sup −1}. Under optimum conditions, PVC and PMMA mixtures are also separated efficiently by froth flotation associated with KMnO{sub 4} treatment. The purity of PC, PVC and PMMA is up to 100%, 98.41% and 98.68%, while the recovery reaches 96.82%, 98.71% and 98.38%, respectively. Economic analysis manifests remarkable profits of the developed process. Reusing KMnO{sub 4} solution is feasible, enabling the process greener.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Effects in the Poly-N-Vinylcaprolactam/Titanium(IV) Oxides Nanocomposite System and Their Nature

Nanocomposites based on poly-N-vinylcaprolactam (PVC), characterized by different drying temperatures of aqueous PVC solution at 25°С (PVC25) and 40°С (PVC40), with titanium(IV) oxide nanoparticles (TONs) (η-phase (TP: TiO{sub 2–x} · mH{sub 2}O) with a superstructure to the anatase structure and ordered solid solution with partial replacement of oxygen atoms in the η-phase with peroxo group O {sub 2}{sup 2–} (PP: TiO{sub x}(O{sub 2}){sub 2–x} · nH{sub 2}O)) have been obtained for the first time and characterized by X-ray diffraction and IR spectroscopy. It is found that a common feature of TP/PVC and PP/PVC obtained by dry mixing and grinding is the decrease in the number of water molecules for TP and PP in the interlayer space of the structure and their attachment to the PVC amide groups; the differences are related to the specificity of PVC behavior in these systems: mechanodestruction of PVC in PP/PVC40 and different numbers of water molecules in PVC25 and PVC40.

36 MATERIALS SCIENCE↗

Electrochemical Deconstruction of Ortho-Phthalate Plasticizers and Recovery of Plasticizing Moieties

Electrochemical methods for the direct reduction of alkyl esters have been understudied but provide a potential advantage for addressing specific waste streams given that such strategies often require only a minimal chemical profile. One such waste stream that could benefit from electrochemical remediation is poly(vinyl chloride) (PVC) plastics. PVC recycling often faces challenges due to the complexity of such waste. Solvent-based recycling methods pose several advantages for addressing post-use PVC; however, such methods are complicated by the high amounts of toxic legacy plasticizers (ortho-phthalates) present in PVC. A potential solution to addressing such phthalates is to address them electrochemically, coupled with recovery of the resulting valuable products. Presented herein is an optimized electrochemical method for ester activation that is leveraged to separate and recover the aromatic and alkyl components of ortho-phthalate plasticizers. The resulting aliphatic alcohols may be reused to prepare other non-toxic plasticizers. This electro-degradation method is demonstrated on six phthalates that have been identified to pose health concerns in addition to plasticizers recovered from commercial samples of PVC.

di-(2-ethylhexyl) phthalate↗

Mechanistic insights into the pyrolysis of poly (vinyl chloride)

The accumulation of unmanaged plastic waste in the environment has a devastating impact upon marine life and human health. Catalytic and thermal pyrolysis are promising technologies toward the efficient utilization of plastic waste. Yet, the processing of polymers, such as polyvinyl chloride (PVC), that decompose into corrosive compounds remains a major challenge. In this work, we employ density functional theory (DFT) and thermogravimetric analysis (TGA) to explore the elementary chemical steps that underpin the thermal decomposition of PVC. We determine that the dehydrochlorination reaction (i.e., 1 st stage of thermal decomposition) begins in tertiary chloride defects and propagates via HCl–mediated autocatalysis of internal allylic (IA) chloride groups. The latter groups, when in the vicinity of π–conjugated polymer segments, release HCl in a facile manner. We predict that other compounds, including hydrogen halides and H 2 O could also catalyze PVC’s dehydrochlorination. We suggest that hydrogen halides are the most efficient catalysts for this process, while other compounds like H 2 O may slow down the dehydrochlorination compared to purely HCl-catalyzed process, because of the dilution of the produced HCl. This result is corroborated by TGA experiments. Additionally, we study the thermochemistry and kinetics of polyene chain crosslinking and the formation of aromatics. The former reaction proceeds in parallel with the dehydrochlorination process (i.e., during the 1st stage of thermal decomposition), whilst the latter may occur at high temperatures (i.e., during the 2 nd stage of thermal decomposition). Furthermore, this work contributes to the fundamental understanding of molecular scale phenomena that take place during PVC pyrolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recovery of solid fuel from municipal solid waste by hydrothermal treatment using subcritical water

Highlights: Black-Right-Pointing-Pointer Hydrothermal treatment using subcritical water was studied to recover solid fuel from MSW. Black-Right-Pointing-Pointer More than 75% of carbon in MSW was recovered as char. Black-Right-Pointing-Pointer Heating value of char was comparable to that of brown coal and lignite. Black-Right-Pointing-Pointer Polyvinyl chloride was decomposed at 295 Degree-Sign C and 8 MPa and was removed by washing. - Abstract: Hydrothermal treatments using subcritical water (HTSW) such as that at 234 Degree-Sign C and 3 MPa (LT condition) and 295 Degree-Sign C and 8 MPa (HT condition) were investigated to recover solid fuel from municipal solid waste (MSW). Printing paper, dog food (DF), wooden chopsticks, and mixed plastic film and sheets of polyethylene, polypropylene, and polystyrene were prepared as model MSW components, in which polyvinylchloride (PVC) powder and sodium chloride were used to simulate Cl sources. While more than 75% of carbon in paper, DF, and wood was recovered as char under both LT and HT conditions, plastics did not degrade under either LT or HT conditions. The heating value (HV) of obtained char was 13,886-27,544 kJ/kg and was comparable to that of brown coal and lignite. Higher formation of fixed carbon and greater oxygen dissociation during HTSW were thought to improve the HV of char. Cl atoms added as PVC powder and sodium chloride to raw material remained in char after HTSW. However, most Cl originating from PVC was found to converse into soluble Cl compounds during HTSW under the HT condition and could be removed by washing. From these results, the merit of HTSW as a method of recovering solid fuel from MSW is considered to produce char with minimal carbon loss without a drying process prior to HTSW. In addition, Cl originating from PVC decomposes into soluble Cl compound under the HT condition. The combination of HTSW under the HT condition and char washing might improve the quality of char as alternative fuel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of thermal treatment on selective separation of post consumer plastics prior to froth flotation

Highlights: • Both PET and PVC have nearly the same densities. • The best pH value will be 4 for optimizing pH values. • Malic acid gave the best results for selective separation of PET and PVC. - Abstract: Plastics have become the widely used materials because of their advantages, such as cheapness, endurance, lightness, and hygiene. However, they cause waste and soil pollution and they do not easily decompose. Many promising technologies are being investigated for separating mixed thermoplastics, but they are still uneconomical and unreliable. Depending on their surface characteristics, these plastics can be separated from each other by flotation method which is useful mineral processing technique with its low cost and simplicity. The main objective of this study is to investigate the flotation characteristics of PET and PVC and determine the effect of plasticizer reagents on efficient plastic separation. For that purpose, various parameters such as pH, plasticizer concentration, plasticizer type, conditioning temperature and thermal conditioning were investigated. As a result, PET particles were floated with 95.1% purity and 65.3% efficiency while PVC particles were obtained with 98.1% purity and 65.3% efficiency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetic Evaluation of the Nanoparticles Coated with Polyvinylpyrrolidone and Polyvinyl Chloride Nanoparticles Synthesized by Electro-deposition Method for Hyperthermia Application

Fe{sub 3}O{sub 4} nanoparticles, coated with polyvinylpyrrolidone (PVP) + polyvinyl chloride (PVC), were synthesized using cathodic electrochemical deposition (CED) technique. Physical properties of the uncoated and PVP + PVC-coated nanoparticles were investigated using several methods including X-ray diffraction (XRD), transmission electron microscopy (TEM), vibrating sample magnetometry (VSM), Fourier transform infrared (FT-IR), and AC susceptometer. In both the samples, single-phase formation in cubic spinel structure is detected in the XRD analysis. In this study, the mean crystallite size of the prepared specimens is found to be varied from 10.2 to 8.7 nm after PVP + PVC coating. The results of the FT-TR test thoroughly verified the existence of PVP/PVC layer onto the surface of the electrodeposited NPs, and magnetic results also confirmed a superparamagnetic (SPM) behavior at room temperature for both of them. Coercivity and magnetization saturation reduction have also been observed, despite having lower grain size. Also, weak magnetic interactions of inter-particle and a superspin glass-like behavior at low temperatures are confirmed. In addition, increasing of PVP + PVC content on the surface coating of the magnetic nanoparticles has decreased the inter-particle interactions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects; from coding an Arduino to building PVC piping to 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into/out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects such as coding an Arduino, building PVC piping, and 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into and out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled or pushed through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point. These times, as well as the temperatures, are the data necessary for the project and must be extremely accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of Vehicle Fuel System Elastomers and Plastics with Test Fuels Representing Gasoline Blended with 10% Ethanol (E10) and 16% Isobutanol (iBu16)

The compatibilities of fuel system elastomers and plastics were evaluated for test fuels containing 16 vol.% isobutanol (iBu16) and 10 vol.% ethanol (E10). Elastomers included two fluorocarbons, four acrylonitrile butadiene rubbers (NBRs), and one type of fluorosilicone, neoprene, and epichlorohydrin/ethylene oxide. Plastic materials included four nylon grades, three polyamides, polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), ethylene tetrafluoroethylene (ETFE), polyphenylene sulfide (PPS), high-density polyethylene (HDPE), polybutylene terephthalate (PBT), polyoxymethylene (POM), flexible polyvinylchloride (PVC), polyetherimide (PEI), polyetheretherketone (PEEK), and a phenol formaldehyde reinforced with glass fiber (GFPF). For each polymer material, the volume, mass, and hardness were measured before and after drying. Dynamic mechanical analysis (DMA) measurements were also performed on the dried specimens.For the elastomer materials the measured properties were similar for both fuels. The fluorocarbons and fluorosilicone swelled the least (~20%), while more moderate (20-45%) expansion occurred for the two NBR hose grades and (ECO). HNBR, neoprene, and silicone exhibited high swelling and softening, which likely precludes their use in many fuel systems. For the plastic materials, the observed swell was low; Nylon 11 swelled around 15%, but otherwise, their measured swell was <10%. Many of the plastics also showed sensitivity to alcohol type, as the E10 test fuel often imparted appreciably higher swell than iBu16. In general, the plastic materials showed good compatibility with the iBu16 and E10 test fuels. Here, the sole exception was the PVC material, which was structurally degraded from exposure to either fuel type. Compositional analysis showed high fuel retention in Nylon 12 and PVC. PVC also experienced a significant reduction in plasticizer compounds following exposure, which resulted in embrittlement and an increase in the glass-to-rubber transition temperature.

33 ADVANCED PROPULSION SYSTEMS↗

Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but their level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE Healthcare), followed by a CT scan for attenuation correction (AC). For each experiment, separate images were created including reconstruction with no corrections (NC), with AC, with attenuation and dual-energy window (DEW) scatter correction (ACSC), with attenuation and partial volume correction (PVC) applied (ACPVC), and with attenuation, scatter, and PVC applied (ACSCPVC). The DEW SC method used was modified to account for the presence of the low-energy tail. Results: T-tests showed that the mean error in absolute activity measurement was reduced significantly for AC and ACSC compared to NC for both (hot and cold) datasets (p < 0.001) and that ACSC, ACPVC, and ACSCPVC show significant reductions in mean differences compared to AC (p ≤ 0.001) without increasing the uncertainty (p > 0.4). The effect of SC and PVC was significant in reducing errors over AC in both datasets (p < 0.001 and p < 0.01, respectively), resulting in a mean error of 5% ± 4%. Conclusions: Quantitative measurements of cardiac {sup 99m}Tc activity are achievable using attenuation and scatter corrections, with the authors’ dedicated cardiac SPECT camera. Partial volume corrections offer improvements in measurement accuracy in AC images and ACSC images with elevated background activity; however, these improvements are not significant in ACSC images with low background activity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bio‐based glycerol plasticizers for flexible poly(vinyl chloride) blends

Abstract A series of glycerol‐based compounds were investigated for their application as plasticizers for flexible poly(vinyl chloride) (PVC) blends. The effect of plasticizer chemical structure on the performance, migration behavior, and blend morphology were evaluated and compared to blends produced using the commercial plasticizer dioctyl terephthalate (DOTP). Blends containing 40 phr (parts per hundred rubber) of glycerol‐based plasticizer showed a considerable reduction (between 54 to 86°C) in glass transition temperature ( T g ) relative to neat PVC ( T g ~ 80°C). Tensile testing of samples prepared with the glycerol analogs demonstrated higher ductility (elongation at break values of up to 97%) than DOTP (elongation at break value of 75%) at identical plasticizer loadings. The surface morphologies showed excellent incorporation of the glycerol plasticizers functionalized with alkyl chains longer than four carbons in length into the PVC matrix, whereas droplet formation was observed in blends with shorter chain glycerol derivatives. Leaching behavior of the plasticized samples were evaluated into different media and showed that plasticizers comprised of branched, or longer alkyl chains produced 2‐ to 4‐fold lower migration rates compared to those with shorter alkyl chains into polar solutions.

Halloran, Matthew W.↗

Mixing and stabilization study of a partially premixed swirling flame using laser induced fluorescence

A laboratory-scale swirling burner, presenting many similarities with gas turbines combustors, has been studied experimentally using planar laser induced fluorescence (PLIF) on OH radical and acetone vapor in order to characterize the flame stabilization process. These diagnostics show that the stabilization point rotates in the combustion chamber and that air and fuel mixing is not complete at the end of the mixing tube. Fuel mass fraction decays exponentially along the mixing tube axis and transverse profiles show a gaussian shape. However, radial pressure gradients tend to trap the fuel in the core of the vortex that propagates axially in the mixing tube. As the mixing tube vortex enters the combustion chamber, vortex breakdown occurs through a precessing vortex core (PVC). The axially propagating vortex shows a helicoidal trajectory in the combustion chamber which trace is observed with transverse acetone PLIF. As a consequence, the stabilizing point of the flame in the combustion chamber rotates with the PVC structure. This phenomenon has been observed in the present study with a high speed camera recording spontaneous emission of the flame. The stabilization point rotation frequency tends to increase with mass flow rates. It was also shown that the coupling between the PVC and the flame stabilization occurs via mixing, explaining one possible coupling mechanism between acoustic waves in the flow and the reaction rate. This path may also be envisaged for flashback, an issue that will be more completely treated in a near future. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

{sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography-Based Radiotherapy Target Volume Definition in Non-Small-Cell Lung Cancer: Delineation by Radiation Oncologists vs. Joint Outlining With a PET Radiologist?

Purpose: {sup 18}F-Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) has benefits in target volume (TV) definition in radiotherapy treatment planning (RTP) for non-small-cell lung cancer (NSCLC); however, an optimal protocol for TV delineation has not been determined. We investigate volumetric and positional variation in gross tumor volume (GTV) delineation using a planning PET/CT among three radiation oncologists and a PET radiologist. Methods and Materials: RTP PET/CT scans were performed on 28 NSCLC patients (Stage IA-IIIB) of which 14 patients received prior induction chemotherapy. Three radiation oncologists and one PET radiologist working with a fourth radiation oncologist independently delineated the GTV on CT alone (GTV{sub CT}) and on fused PET/CT images (GTV{sub PETCT}). The mean percentage volume change (PVC) between GTV{sub CT} and GTV{sub PETCT} for the radiation oncologists and the PVC between GTV{sub CT} and GTV{sub PETCT} for the PET radiologist were compared using the Wilcoxon signed-rank test. Concordance index (CI) was used to assess both positional and volume change between GTV{sub CT} and GTV{sub PETCT} in a single measurement. Results: For all patients, a significant difference in PVC from GTV{sub CT} to GTV{sub PETCT} exists between the radiation oncologist (median, 5.9%), and the PET radiologist (median, -0.4%, p = 0.001). However, no significant difference in median concordance index (comparing GTV{sub CT} and GTV{sub FUSED} for individual cases) was observed (PET radiologist = 0.73; radiation oncologists = 0.66; p = 0.088). Conclusions: Percentage volume changes from GTV{sub CT} to GTV{sub PETCT} were lower for the PET radiologist than for the radiation oncologists, suggesting a lower impact of PET/CT in TV delineation for the PET radiologist than for the oncologists. Guidelines are needed to standardize the use of PET/CT for TV delineation in RTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polycyclic aromatic hydrocarbons (PAH) formation from the pyrolysis of different municipal solid waste fractions

Highlights: • PAH from pyrolysis of 9 MSW fractions was investigated. • Pyrolysis of plastics released more PAH than that of biomass. • Naphthalene was the most abundant PAH in the tar. • The mechanism of PAH release from biomass and plastics was proposed. - Abstract: The formation of 2–4 ring polycyclic aromatic hydrocarbons (PAH) from the pyrolysis of nine different municipal solid waste fractions (xylan, cellulose, lignin, pectin, starch, polyethylene (PE), polystyrene (PS), polyvinyl chloride (PVC), and polyethylene terephthalate (PET)) were investigated in a fixed bed furnace at 800 °C. The mass distribution of pyrolysis was also reported. The results showed that PS generated the most total PAH, followed by PVC, PET, and lignin. More PAH were detected from the pyrolysis of plastics than the pyrolysis of biomass. In the biomass group, lignin generated more PAH than others. Naphthalene was the most abundant PAH, and the amount of 1-methynaphthalene and 2-methynaphthalene was also notable. Phenanthrene and fluorene were the most abundant 3-ring PAH, while benzo[a]anthracene and chrysene were notable in the tar of PS, PVC, and PET. 2-ring PAH dominated all tar samples, and varied from 40 wt.% to 70 wt.%. For PS, PET and lignin, PAH may be generated directly from the aromatic structure of the feedstock.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pyrolysis Reactions of (2-Chloroethyl)benzene

Pyrolysis of polyvinyl chloride (PVC) is considered an alternative to traditional, mechanical methods of recycling. However, there is insufficient research conducted on the thermal decomposition pathways of PVC, particularly the fate of chlorinated hydrocarbons generated during the chemical recycling process. One significant product from the pyrolysis of PVC is (2- chloroethyl)benzene. Using a hyperthermal tubular reactor and matrix-isolation FTIR techniques, the pyrolysis products of gasphase (2-chloroethyl)benzene were identified. Following pyrolysis at 1400 K, the FTIR spectra indicated the formation of HCl, styrene, phenylacetylene, benzene, vinylacetylene, acetylene, propyne, ethylene, and propargyl radical.

Aromatic compounds↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

Particle-vibration coupling: Recent advances in microscopic calculations with the Skyrme Hamiltonian

In this contribution, we report some recent progress in our understanding of particle-vibration coupling (PVC) in nuclei. In particular, we first review the formal development that has allowed some of us to deduce the PVC equations within the Green’s functionmethod. Applications are then discussed, both in the case of single-particle states and giant resonances in magic nuclei. We also present a new model that extends the PVC ansatz and is meant to account for the complete low-lying spectra of odd nuclei.

74 ATOMIC AND MOLECULAR PHYSICS↗