A cooled-gas pyrometer for use in hypersonic engine testing

A cooled-gas pyrometer designed for application in a hypersonic research engine program was fabricated and tested. Design and operational considerations and calibration data are presented. The probe was tested in a rocket-engine exhaust stream operating at Mach 2 and 2300 K. Test temperature measurements agreed to within 2 percent with a radiation shielded thermocouple probe.

Glawe, G. E.↗

Rotating turbine blade pyrometer

Non-contacting pyrometer system optically measures surface temperature distribution on rotating turbine blade, comprising line-by-line scan via fiber optic probe. Each scan line output is converted to digital signals, temporarily stored in buffer memory, and then processed in minicomputer for display as temperature.

Buchele, D. R.↗

A sensitive optical pyrometer for shock-temperature measurements

A new optical system was used to determine temperatures above 2400 K in shocked materials by measuring the spectral radiance of sub-microsecond pulses of light emitted from initially transparent solid samples in the visible and near infrared (450 to 900 nm). The high sensitivity of this optical pyrometer is attributed to the small number of channels, large aperture (0.03 steradian), the large bandwidth per channel (40 nm), and large photodiode detection area (0.2 sq cm). Improved calibration techniques reduce systematic errors encountered in previous shock-temperature experiments.

Boslough, M. B.↗

Seven-wavelength pyrometer for determining surface temperature of ablation materials

Results which were achieved by a seven-wavelength pyrometer last year are reported in this paper. These studies are directed toward the development of a method for determining the real surface temperature of thermal protection materials and for evaluating its emittance under varieties of reentry environment. A description of the data processing method and apparatus is also included.

Yi, H.↗

High-Resolution, Two-Wavelength Pyrometer

Modified two-color pyrometer measures temperatures of objects with high spatial resolution. Image focused on hole 0.002 in. (0.05 mm) in diameter in brass sheet near end of bundle, causing image to be distributed so fibers covered by defocused radiation from target. Pinhole ensures radiation from only small part of target scene reaches detector, thus providing required spatial resolution. By spreading radiation over bundle, pinhole ensures entire active area of detectors utilized. Produces signal as quiet as conventional instruments but with only 1/64 input radiation.

Bickler, Donald B.↗

Dual purpose pyrometer for temperature and solidification velocity measurement

A dual purpose pyrometer is described that allows both accurate radiance temperature measurement and fast temporal response. The system uses two silicon photodiodes with separate optical paths derived from a common spot on the sample. The optical bandwidths and response times of each detection circuit are tailored to the function of each radiometer. The radiance temperature of electromagnetically levitated metallic samples is measured over a narrow optical bandwidth with a high-gain silicon detector. The velocity of solidification of undercooled melts can be deduced from the rise time of the second silicon detector which samples a broad optical bandwidth and has a fast response time. Results from experiments on the undercooling and solidification behavior of electromagnetically levitated pure nickel show that the solidification velocity approaches 17 m/s at high undercooling.

Hofmeister, W. H.↗

Evaluation of Raytek infrared pyrometer for continuous propellant temperature measurement

The primary purpose of this evaluation was to determine if the Raytek IR pyrometer that was installed in the 600 gallon propellant mixers could be used to provide a continuous, accurate, reliable measurement of the propellant temperature during mixing. The Raytek infrared sensor is not recommended to be used for controlling propellant temperature nor for inspection buy-off. The first part of the evaluation was to determine the accuracy of the sensor in measuring the propellant temperature. The second part was to determine the reliability of the air purge design in preventing contamination of the IR window.

Dykstra, Mark D.↗

Two-Band Pyrometers Detect Hydrogen Fires

Two-band infrared pyrometers detect small hydrogen fires at greater distances in full daylight being developed. Detectors utilize part of infrared spectrum in which signals from hydrogen flames 10 to the 3rd power to 10 to the 4th power times as intense as ultraviolet region of current detectors. Utilize low-loss infrared lenses for focusing and for limiting fields of view to screen out spurious signals from nearby sources. Working distances of as much as 100 meters possible. Portable, battery-powered unit gives audible alarm, in form of increase in frequency of tone, when aimed at hydrogen fire.

Collins, J. David↗

Method and Apparatus for Polaradiometric Pyrometer

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) = I(sub 1p) + I(sub 2p) and I(sub s) = I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

Polaradiometric Pyrometer

Polaradiometric pyrometer provides measurements from which one calculates temperature of specimen, without having to measure or account explicitly for polarization-dependent emissivities and reflectivities of specimen. Provides measurements of spectral intensities in two perpendicular polarizations. When brightness of lamp set so two measured intensities equal, measurements used to compute temperature.

Abtahi, Ali A.↗

Remote Heat Flux Using a Self Calibration Multiwavelength Pyrometer and a Transparent Material

A self calibrating multiwavelength pyrometer was used to conduct remote heat flux measurements using a transparent sapphire disk by determining the sapphire disk's front and back surface temperatures. Front surface temperature (Tfs) was obtained from detection of surface emitted radiation at long wavelengths (k = 6 gm). Back surface temperature (Tbs) was obtained from short wavelength (1 to 5 gm) radiation transmitted through the sapphire disk. The thermal conductivity of the sapphire disk and the heat transfer coefficients h, and h2 of its surfaces are determined experimentally. An analysis of the heat flux measurement is presented.

Ng, Daniel↗

Remote Heat Flux Measurement Using a Self Calibration Multiwavelength Pyrometer and a Transparent Material

A self calibrating multiwavelength pyrometer was used to conduct remote heat flux measurements using a transparent sapphire disk by determining the sapphire disk's front and back surface temperatures. Front surface temperature (Tfs) was obtained from detection of surface emitted radiation at long wavelengths (lambda > 6 micrometers). Back surface temperature (Tbs) was obtained from short wavelength (1 to 5 micrometers) radiation transmitted through the sapphire disk. The thermal conductivity k of the sapphire disk and the heat transfer coefficients h(sub 1) and h(sub 2) of its surfaces are determined experimentally. An analysis of the heat flux measurement is presented.

Ng, Daniel↗

Polaradiometric pyrometer in which the parallel and perpendicular components of radiation reflected from an unpolarized light source are equalized with the thermal radiation emitted from a measured object to determine its true temperature

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) =I(sub 1p) + I(sub 2p) and I(sub s)=I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

High resolution color band pyrometer ratioing

The sensing head of a two-color band ratioing pyrometer of a known type using a fiber optic cable to couple radiation to dual detector photodiodes is improved to have high spatial resolution by focusing the radiation received through an objective lens (i.e., by focusing the image of a target area) onto an opaque sheet spaced in front of the input end of the fiber optic cable. A two-mil hole in that sheet then passes radiation to the input end of the cable. The detector has two channels, one for each color band, with an electronic-chopper stabilized current amplifier as the input stage followed by an electronic-chopper stabilized voltage amplifier.

Bickler, Donald B.↗

A Plenoptic Multi-Color Imaging Pyrometer

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of a camera lens allow separate 2D images to be obtained on a single image sensor at three different and adjustable wavelengths selected by the user. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, and a luminous sulfur match flame. The images obtained of the calibration furnace and radiation heater were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument can measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D temperature measurements of the radiation heater are shown.

Danehy, Paul M.↗

Emissivity independent optical pyrometer

Disclosed herein are representative embodiments of methods, apparatus, and systems for determining the temperature of an object using an optical pyrometer. Certain embodiments of the disclosed technology allow for making optical temperature measurements that are independent of the surface emissivity of the object being sensed. In one of the exemplary embodiments disclosed herein, a plurality of spectral radiance measurements at a plurality of wavelengths is received from a surface of an object being measured. The plurality of the spectral radiance measurements is fit to a scaled version of a black body curve, the fitting comprising determining a temperature of the scaled version of the black body curve. The temperature is then output. The present disclosure is not to be construed as limiting and is instead directed toward all novel and nonobvious features and aspects of the various disclosed embodiments, alone or in various combinations and subcombinations with one another.

36 MATERIALS SCIENCE↗

System and method for multi-channel pyrometer allowing non-contact temperature measurements down to 800 K on the microsecond scale

The present disclosure relates to a system for sensing temperature changes on a microsecond scale. The system uses a multi-channel pyrometer that works in the NIR spectrum to receive thermal radiation. Each channel includes an interference filter tuned to pass thermal radiation within a specified wavelength range, and a detector. Each detector detects thermal radiation focused on it. Each channel further includes an interference filter which reflects thermal radiation which does not pass through it to a subsequent downstream interference filter of a subsequent channel. Each subsequent interference filter is oriented to reflect the thermal radiation not passing through it to a next downstream one of the subsequent interference filters. A subsystem is included for receiving the output from the detectors and determining sensed temperature data therefrom, allowing measurement of temperatures down to 800 K.

Montgomery, Jeffrey↗