Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Variational autoencoders for at-source data reduction and anomaly detection in high energy particle detectors

Detectors in next-generation high-energy physics experiments face several daunting requirements, such as high data rates, damaging radiation exposure, and stringent constraints on power, space, and latency. To address these challenges, machine learning in readout electronics can be leveraged for smart detector designs, enabling intelligent inference and data reduction at-source. Variational autoencoders (VAEs) offer a variety of benefits for front-end readout; an on-sensor encoder can perform efficient lossy data compression while simultaneously providing a latent space representation that can be used for anomaly detection. Results are presented from low-latency and resource-efficient VAEs for front-end data processing in a futuristic silicon pixel detector. Encoder-based data compression is found to preserve good performance of off-detector analysis while significantly reducing the off-detector data rate as compared to a similarly sized data filtering approach. Furthermore, the latent space information is found to be a useful discriminator in the context of real-time sensor defect monitoring. Together, these results highlight the multifaceted utility of autoencoder-based front-end readout schemes and motivate their consideration in future detector designs.

47 OTHER INSTRUMENTATION↗

Enhanced Detection of Primary Biological Aerosol Particles Using Machine Learning and Single-Particle Measurement

Accurately identifying primary biological aerosol particles (PBAPs) using analytical techniques poses inherent challenges due to their resemblance to other atmospheric carbonaceous particles. Here, we present a study of an enhanced method for detecting PBAPs by combining single-particle measurement with advanced supervised machine learning (SML) techniques. We analyzed ambient particles from a variety of environments and lab-generated standards, focusing on chemical composition for traditional rule-based and clustering approaches and incorporating morphological features into the SML approaches, neural networks and XGBoost, for improved accuracy. This study demonstrates that SML methods outperform traditional methods in quantifying PBAPs, achieving significant improvements in precision, recall, F1-score, and accuracy, leading to an increased number of detected PBAPs by at least 19%. The adaptability of the proposed XGBoost-based SML model is showcased in comparison to traditional methods in categorizing PBAPs for blind data sets from different geographical locations. Two field case studies were investigated, over agricultural land and Amazonia rain forest, representing relatively low and high concentrations of PBAPs, respectively, where XGBoost consistently detected up to 3.5 times more PBAPs than traditional methods. Precise detection of PBAPs in the atmosphere could significantly improve the prediction of climatic impacts by them.

42 ENGINEERING↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Neutrino-nucleus cross section impacts on neutrino oscillation measurements

The challenges in neutrino-nucleus cross section modeling and its impact on neutrino oscillation experiments are widely recognized. However, a comprehensive and theoretically robust estimation of cross section uncertainties has been lacking, and few studies have quantitatively examined their impact on oscillation measurements. In this work, we evaluate the effect of cross section uncertainties on oscillation parameters using setups inspired by NOvA and DUNE. To characterize these uncertainties, we adopt multiple neutrino-nucleus event generators and simulate a realistic experimental procedure that incorporates near-detector data and near-to-far-detector extrapolation. Our results confirm that cross section uncertainties cannot significantly bias oscillation results in current statistics-dominated experiments like NOvA. However, they could lead to substantial bias for future systematics-dominated experiments like DUNE, even when near-detector data are employed to mitigate uncertainties. These findings underscore the need for further studies on the quantitative impacts of cross section modeling, improved strategies to utilize near-detector data and the PRISM concept, and more robust cross section models to optimize the success of future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heterogeneous Point Set Transformers for Segmentation of Multiple View Particle Detectors

NOvA is a long-baseline neutrino oscillation experiment that detects neutrino particles from the NuMI beam at Fermilab. Before data from this experiment can be used in analyses, raw hits in the detector must be matched to their source particles, and the type of each particle must be identified. This task has commonly been done using a mix of traditional clustering approaches and convolutional neural networks (CNNs). Due to the construction of the detector, the data is presented as two sparse 2D images: an XZ and a YZ view of the detector, rather than a 3D representation. We propose a point set neural network that operates on the sparse matrices with an operation that mixes information from both views. Our model uses less than 10% of the memory required using previous methods while achieving a 96.8% AUC score, a higher score than obtained when both views are processed independently (85.4%).

Robles, Edgar E. [UC, Irvine (main)]↗

Search for a Hidden Sector Scalar from Kaon Decay in the Dimuon Final State at ICARUS

We present a search for long-lived particles (LLPs), produced in kaon decays, that decay to two muons inside the ICARUS neutrino detector. This channel would be a signal of hidden sector models that can address outstanding issues in particle physics such as the strong CP problem and the microphysical origin of dark matter. The search is performed with data collected in the Neutrinos at the Main Injector (NuMI) beam at Fermilab corresponding to 2.41 × 10 20 protons-on-target. No new physics signal is observed, and we set world leading limits on heavy QCD axions, as well as for the Higgs portal scalar among dedicated searches. Limits are also presented in a model-independent way applicable to any new physics model predicting the process 𝐾 → 𝜋 + 𝑆⁡(→ 𝜇⁢𝜇), for a LLP 𝑆. This result is the first search for new physics performed with the ICARUS detector at Fermilab. It paves the way for the future program of LLP searches at ICARUS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Directional response of several geometries for reactor-neutrino detectors

Here we have modeled six abstracted detector designs, with the goal of determining their ability to resolve the direction to an antineutrino source, including two for which we have operational data for validating our computer modeling and analytical processes. We have found that the most promising options, regardless of scale and range, have angular resolutions on the order of a few degrees, which is better than any yet achieved in practice by a factor of at least two. We examine and compare several approaches to detector geometry for their ability not only to detect the inverse beta decay (IBD) reaction, but also to determine the source direction of incident antineutrinos. The information from these detectors provides insight into reactor power and burning profile, which is especially useful in constraining the clandestine production of weapons material. In a live deployment, a nonproliferation detector must be able to isolate the subject reactor, possibly from a field of much-larger power reactors; directional sensitivity can help greatly with this task. We also discuss implications for using such detectors in longer-distance observation of reactors, from a few kilometers to hundreds of kilometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol size determination via light scattering of viruses and protein complexes

Abstract The study of ultrafine particle aerosols, those with particle diameters of 100 nm or less, is important due to their impact on our health and environment. However, given their small sizes, such particles can be difficult to measure and trace. Most common optical methods are unable to reach this size range. Other methods exist but incur other limitations, such as the need for electrically charged particles. Here we show how light scattering can be used to detect and measure the size and location of single viruses and protein complexes forming an aerosol beam, as well as trace their path. We were able to detect individual particles down to 16 nm in diameter. The primary purpose of our instrument is to monitor the delivery of single bioparticles to the focus of an X-ray laser to image those particles, but it has the potential to study any other aerosols such as those resulting from ultrafine sea spray, with important consequences for cloud formation and climate modeling, or from combustion, responsible for most air pollution and resulting health impacts.

Physics↗

Search for the production of Higgs-portal scalar bosons in the NuMI beam using the MicroBooNE detector

We present the strongest experimental limits to date on the mixing angle, 𝜃, with which a new scalar particle, 𝑆, mixes with the Higgs field in the mass range 110 MeV < 𝑚 𝑆 <155 MeV. This result uses the MicroBooNE liquid argon time projection chamber to search for decays of these Higgs-portal scalar particles through the 𝑆 → 𝑒 + ⁢𝑒 − channel with the decays of kaons in the NuMI neutrino beam acting as the source of the scalar particles. The analysis uses an exposure of 2.01 × 10 21 protons on target of NuMI beam data including periods when the beam focusing system was configured to focus positively charged hadrons and separate periods when negatively charged hadrons were focused. The analysis searches for scalar particles produced from kaons decaying in flight in the beam’s decay volume and at rest in the target and absorber. At 𝑚 𝑆 =125 MeV (𝑚 𝑆 =150 MeV) we set a limit of 𝜃 < 3.19 ×10 −4 (𝜃 < 2.79 ×10 −4 ) at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on Covariant Dark-Matter–Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA. We report on the results of a relativistic extension to the nonrelativistic effective field theory (NREFT) from a 5.5 t fiducial mass and 60 live days of exposure. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the weakly interacting massive particle which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0 keV nr to 270 keV nr , we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

Development of a Flow-through Cell for Ultrasonic Extraction (UE)─Single Particle (SP)─ICP-MS─an Approach for Nano/Microparticle Elemental and Isotopic Analysis

Nanotechnology is a salient part of the scientific landscape, and analytical approaches are rapidly evolving to enable small-scale characterization of nano- and microparticle compositions and impurities. Here, a flow-through sonicating cell was developed for direct particle extraction from a silicon wafer and integrated with an inductively coupled plasma–mass spectrometer (ICP-MS) for subsequent elemental and isotopic characterization of the released particles. Ultrasonic extraction (UE)─single particle (SP)─ICP-MS offers controlled particle mobilization from solid substrates and allows for increased sample throughput by eliminating the need for pre-extraction of particles and decreasing sample preparation steps. Coupling this device to an ICP-MS with a time-of-flight (TOF) mass analyzer, it is possible to distinguish unique isotopic compositions of the particles. Both tungsten and nickel isotopically tagged particles, which were deposited on Si wafers, are presented here with analysis via UE─SP─ICP-MS. This approach could support efforts in the fields of particle synthesis, nuclear safeguards and forensics, environmental monitoring, and semiconductor industries in which the detection of particles from substrates and wafers is critical.

Paul, Molly [ORNL] (ORCID:0009000009672055)↗

Beehive haloscope for high-mass axion dark matter

We propose a new haloscope geometry that can arbitrarily increase the resonator volume for a given target axion mass. This geometry consists of closely packed, overlapping coaxial cavities operating as a single resonator. While the resonant frequency is still determined by the dimensions of the individual “cells,” the strong interactions between the cells encourage the entire “beehive” to oscillate in phase, a phenomenon expected of tightly coupled harmonic oscillators. This synchronization behavior allows the construction of a singly connected large volume resonator at high frequency by simply increasing the number of the cells. Using direct numerical simulations, we verify the existence of a global eigenmode that has a high (40%) form factor in a 169-element beehive resonator. The resonant frequency of the eigenmode is tunable by moving the center rods laterally in unison. The form factor is very tolerant to dimensional deviations and misalignment as a result of mode hybridization due to strong coupling. The beehive haloscope inherits many appealing properties from the conventional coaxial cavity: a high quality factor, compatibility with a solenoid magnet, and ease of fabrication, tuning, and coupling. We argue that this geometry is an excellent candidate for high-mass axion searches covering the post-inflationary parameter space (>5 GHz).

47 OTHER INSTRUMENTATION↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Chemical imaging of individual stratospheric particles sampled over North America

The increasing size, severity, and frequency of wildfires have led to dramatic increases in particulate matter concentrations in the troposphere. Severe wildfires can generate intense convective systems capable of transporting large quantities of biomass burning organic aerosols (BBOA) to the upper troposphere and lower stratosphere (UTLS). Chemically complex organic matter and light-absorbing carbonaceous material is introduced into stratospheric regions that were historically isolated from direct surface emissions. In this study, stratospheric particles were sampled over North America during the Dynamics and Chemistry of the Summer Stratosphere (DCOTSS) campaign, an aircraft-based research project designed to characterize convective perturbation in the UTLS. Particle samples collected from six research flights during summer 2022 were analyzed using Computer-Controlled Scanning Electron Microscopy and Scanning Transmission X-ray Microscopy to investigate particle size distributions, morphology, chemical composition, and mixing state of stratospheric particles along transects across the continental United States and adjacent Pacific Ocean airspace. Analysis revealed that all sampled particles contained detectable levels of carbon, with most exhibiting organic volume fractions of 0.37 ± 0.20. Notably, about 5% of the particles also contained soot inclusions, which indicates the presence of refractory black carbon transported to stratospheric altitudes and provides direct evidence of wildfire-derived black carbon reaching the UTLS. Typical particle morphology exhibits organic shells over soot and inorganic cores and suggests secondary processing and aging of BBOA during transport to and within the UTLS. These findings provide compelling evidence that wildfire emissions play a critical role in affecting the long-term composition and radiative properties of stratospheric particles.

Sharpe, Steven [Purdue Univ., West Lafayette, IN (↗

Quantum description of wave dark matter

We outline a fundamentally quantum description of bosonic dark matter (DM) from which the conventional classical-wave picture emerges in the limit 𝑚 ≪10 eV. As appropriate for a quantum system, we start from the density matrix, which encodes the full information regarding the possible measurements we could make of DM and their fluctuations. Following fundamental results in quantum optics, we argue that for DM it is most likely that the density matrix takes the explicitly mixed form of a Gaussian over the basis of coherent states. Deviations from this would generate non-Gaussian fluctuations in DM observables, allowing a direct probe of the quantum state of DM. Our quantum optics–inspired approach allows us to rigorously define and interpret various quantities that are often only described heuristically, such as the coherence time or length. The formalism further provides a continuous description of DM through the wave-particle transition, which we exploit to study how density fluctuations over various physical scales evolve between the two limits and to reveal the unique behavior of DM near the boundary of the wave and particle descriptions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Multipartite Entanglement Patterns Using Single-Particle Green’s Functions

Here, we present a protocol for detecting multipartite entanglement in itinerant many-body electronic systems using single-particle Green’s functions. To achieve this, we first establish a connection between the quantum Fisher information and single-particle Green’s functions by constructing a set of witness operators built out of single electron creation and destruction operators in a doubled system. This set of witness operators is indexed by a momentum k. We compute the quantum Fisher information for these witness operators and show that for thermal ensembles it can be expressed as an autoconvolution of the single-particle spectral function. We then apply our framework to a one-dimensional fermionic system to showcase its effectiveness in detecting entanglement in itinerant electron models. We observe that the detected entanglement level is sensitive to the wave vector associated with witness operator. Our protocol will permit detecting entanglement in many-body systems using scanning tunneling microscopy and angle-resolved photoemission spectroscopy, two spectroscopies that measure the single-particle Green’s function. It offers the prospect of the experimental detection of entanglement through spectroscopies beyond the established route of measuring the dynamical spin response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Identifying Sample Provenance From SEM/EDS Automated Particle Analysis via Few-Shot Learning Coupled With Similarity Graph Clustering

Automated particle analysis (APA) provides a vast amount of compositional data via energy-dispersive X-ray spectroscopy along with size and shape data via scanning electron microscopy for individual particles in a sample. In many instances, APA data are leveraged to support identification of the source of a sample based on the detection of particles of a specific composition. Often, the particles that provide context make up a minuscule portion of the sample. Additionally, the interpretation of complex samples can be difficult due to the diversity of compositions both in the mixture and within a particle. In this work, we demonstrate a method to compute and cluster similarity graphs that describe inter-particle relationships within a sample using a multi-modal few-shot learning neural network. Here, as a proof-of-concept, we show that samples known to have been exposed to gunshot residue can be distinguished from samples occasionally mistaken for gunshot residue. Our workflow builds upon standard APA techniques and data processing methods to unveil additional information in a readily interpretable and quantitatively comparable format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗