Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of an electric field on liquid helium scintillation produced by fast electrons

The dependence on applied electric field (0–40 kV/cm) of the scintillation light produced by fast electrons and α particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations and has a dependence on the energy of the primary ionization electron. Here, we discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Techniques for gamma rays.

The detecting systems used in high energy astrophysics are generally more similar to particle detectors than to optical devices. The basic design of the gamma ray instrument depends on whether the energy range is below about 10 MeV and therefore in the region where the Compton effect predominates in the absorption of the gamma-rays, or above that energy where electron-positron pair production is most important. The most usual approach to the detector system in the lower of the two energy intervals is to use a scintillation counter in the center of the detector system to absorb the photons and permit a measure of their energy, and to surround it by another detector which is employed as an active anticoincidence shield to discriminate against charged particles. In the gamma-ray interval above about 10 MeV, the very low flux of gamma rays and the high particle background has directed the development of high energy gamma-ray telescopes towards complicated techniques and large detector arrays. As a result, several investigators have now turned to the spark chamber as the heart of a detector system. Generally, it is surrounded by an anticoincidence system and is triggered by a counter telescope.

Fichtel, C. E.↗

FY23 Update: Aerosol Sampling for the Canister Deposition Field Demonstration

This report describes the results of preliminary testing of aerosol monitoring equipment that will be used to continuously monitor the aerosol source term for the multi-year Canister Deposition Field Demonstration (CDFD). These data are required inputs for the development and validation of models for the deposition of dust and potentially corrosive salts on the surface of spent nuclear fuel (SNF) dry storage canisters. Surface salt loads correlate with the extent of corrosion damage on a metal surface, and potentially to the likelihood and timing of initiation of stress corrosion cracks. Aerosols will be monitored at the CDFD site using three instruments. A Dekati ® ELPI+ cascade impactor will be used for real-time monitoring of aerosol particle sizes. It will also collect dust in 14 size bins on impactor targets that can be chemically analyzed to determine the soluble salts present as a function of particle size. However, this instrument can only measure dried aerosols, with a diameter of <10 µm. The second instrument is a Topas laser particle size spectrometer, which provides real-time monitoring of aerosol particle sizes up to ~40 µm in size. It monitors both the ambient (potentially deliquesced) aerosol particle size distributions required for the dust deposition models and the distributions of the equivalent dried particles, allowing correlation with the Dekati ® data. However, it does not discriminate between inert dust particles and salt aerosols, and it does not retain samples of the different particle sizes for later analysis. The third instrument that will monitor aerosols at the CDFD site is a Clean Air Status and Trends Network (CASTNET) tower, which uses a multiple canister system to collect weekly samples for analysis to total suspended aerosol particle compositions and atmospheric gas concentrations. This status report describes work in FY23 to develop the capabilities for using these tools. In two training exercises, the cascade impactor and laser particle sizer were deployed in two different testing environments, one indoor and one outdoor. For the cascade impactor, the tests provided opportunities for the operators to familiarize themselves with impactor substrate preparation, and post-test sample removal and analysis. For the laser particle sizer, the tests were used to evaluate different instrument parameters, to determine the most appropriate settings for capturing transient events. Data and samples were collected for weeks to months for each test, and the results are presented here. In addition to the preliminary testing, contracts were developed with WSP Analytical Labs for sample preparation and analysis of the cascade impactor samples. The impactor tower from outdoor test was delivered to WSP and used to train the staff there in disassembly, sample extraction, sample analysis, and tower reassembly with new target substrates. These are tasks that WSP will be performing routinely for the CDFD project. The CASTNET system cannot be purchased or tested until an actual site has been selected for the CDFD test. Work for this FY has been restricted to preparation of contracts for purchasing the CASTNET tower, and for sample analysis, once the tower is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Versatile analog pulse height computer performs real-time arithmetic operations

Multipurpose analog pulse height computer performs real-time arithmetic operations on relatively fast pulses. This computer can be used for identification of charged particles, pulse shape discrimination, division of signals from position sensitive detectors, and other on-line data reduction techniques.

Brenner, R.↗

Modification to the MED and LED source-encoding circuitry for the IMP H and J spacecraft

The circuitry and fabrication changes made on the MED and LED electronics cards for the IMP H and J are reported. Except for the noted changes, the circuitry and module-matrix arrangement is essentially the same as the IMP-1 electronics cards described. In addition, analysis of the IMP-1 transmitted data indicated the desirability of incorporating additional coincident-event threshold detection levels to further discriminate between received particles.

Garrahan, N. M.↗

Hydrometeor discrimination in melting layer using multiparameter airborne radar measurement

Results from a multiparameter airborne radar/radiometer experiment (the Typhoon experiment) are presented. The experiment was conducted in the western Pacific with the NASA DC-8 aircraft, in which a dual-wavelength at X-band and Ka-band and dual-polarization at X-band radar was installed. The signatures of dBZ(X), dBZ(Ka), LDR (linear depolarization ratio) at X-band and DZ=dBZ(X)-dBZ(Ka) are discussed for the data obtained in the penetration of the typhoon Flo. With emphasis on discrimination of hydrometeor particles, some statistical features of the brightband in stratiform rain are discussed.

Kumagai, H.↗

Development of a Low-Cost, Subscale Test System to Evaluate Particle Impingement Erosion in Nozzle Ablative Materials

This viewgraph presentation gives an overview on the development of a low-cost, subscale test system to evaluate particle impingement erosion in nozzle ablative materials. Details are given on the need for a new test bed, solid fuel torch components, solid fuel torch test, additional uses for the solid fuel torch, the development of a supersonic blast tube (SSBT), and particle impingement material discrimination.

Lansing, Matthew D.↗

Early Fire Detection System for Partial and Low Gravity Environments

We present preliminary results on the development of a fire detection system for partial and low gravity environments. A significant challenge is the design of a system with a low false alarm rate. The detection system therefore has to discriminate between combustion particles, cabin, and lunar dust. Aerosol properties are measured and cross referenced to the target detectors at the Gases and Aerosols from Smoldering Polymers (GASP) Laboratory located at the NASA Glenn Research Center. A computational fluid dynamics plume model is also employed to determine the smoke transport properties of the targeted habitats.

Early fire detectioin↗

Electron Calorimeter Experiment

Boron loaded scintillators are suitable for measuring secondary neutrons produced by high-energy particles: protons & electrons Neutron flux can be used to discriminate hadron and electro-magnetic particles Combined effectiveness of all e/p discriminators techniques employedTBD Only moderate improvement in detection efficiency for B-10 concentrations >few% in thick moderators Bottom scintillator might serve as cascade penetration counter (TBC)

Adams, James H.↗

An analysis of IRAS' solar system dust bands

Measurements of longitudinal variations in the brightness and in the latitude of the solar system dust bands recently discovered by IRAS will determine the orbital elements of the particles involved and may discriminate between cometary and asteroidal models of the origin of these bands. The expected variations for bands of dust particles with common orbital elements and small eccentricity and inclination are calculated as functions of semimajor axis.

Dermott, S. F.↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

Capability Demonstration of a 3D CdZnTe Detector on a High-Altitude Balloon Flight

In collaboration between the University of Michigan and Los Alamos National Laboratory, a 3D position-sensing CdZnTe (CZT) detector prototype was built and integrated into a high-altitude balloon platform to evaluate its performance in a space-like mixed-radiation environment. The detector prototype, Orion Eagle, was designed to operate in near-vacuum environments without any temperature regulation. Orion Eagle was hand-launched from NASA’s Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM on September 26, 2021, and successfully operated throughout a 9-hour flight, which reached 38.5 km in altitude. The flight met its objectives, successfully detecting atmospheric gamma rays and galactic cosmic rays, and raising the Technical Readiness Level from 4 to 6 for large-volume 3D CZT detector technology for space applications. Ionization tracks produced by charged particles create spatial signatures in the detector that are distinguishable from discrete gamma-ray interactions. Therefore, the 3D position-sensing capabilities using pixelated electrodes on a CZT detector can help enable discrimination of background charged particles from gamma-ray events without an anticoincidence shield. The potential for background rejection capability, ambient-temperature operation, gamma-ray coded-aperture and Compton imaging, and near High Purity Germanium (HPGe) energy resolution motivate the use of large-volume 3D CZT imaging spectrometers in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A bi-directional charged particle telescope to observe flux, energy spectrum and angular distribution of relativistic and non-relativistic particles

A Charged Particle Telescope (CPT) was designed, fabricated and calibrated to make the following observations: (1) discrimination between various singly charged particles, e.g., electrons, muons and protons, in about 5 to 100 MeV energy range; (2) measurement of the flux and the energy of the charged particles incident to the telescope from two opposite directions and stopping in the telescope, thus obtaining flux and energy spectrum of downward and upward moving charged particles; and (3) measurement of the broad angular distribution of selected particles as a function of azimuthal angle. This telescope can be used to study low energy electron, muon and proton energy spectra. The experiment was flown in a high altitude balloon from Hyderabad, India, in December 1984. This same equipment is also useful in ground level electron, muon spectrum study.

Verma, S. D.↗

Towards more accurate sound field verification using directional acoustic filtering

Attributing omnidirectional sound levels to a specific source in the ocean can be challenging when there are multiple competing sources of sound such as boats, or biological activity. Here, we present a method to directionally filter acoustic measurements based on vector measurements of acoustic pressure and particle velocity. The directional discrimination is applied to estimate sound energy from two marine energy sources: sound generated during the decommissioning of an oil platform and those from an operating tidal energy converter. The application of a directional mask leads to distinctly different spectra and some differences in energy, relative to the unmasked scenarios.

Barosin, Emily (ORCID:0009000765495939)↗

Application of two-component phase Doppler interferometry to the measurement of particle size, mass flux, and velocities in two-phase flows

Two-component phase Doppler interferometry is described, along with its application for the spatially-resolved measurements of particle size, velocity, and mass flux as well as continuous phase velocity. This technique measures single particle events at a point in the flow; droplet size is deduced from the spatial phase shift of the Doppler signal. Particle size influence and discrimination of continuous and discrete phases are among issues covered. Applications are presented for four cases: an example of the discrimination of two sizes of glass beads in a jet flow; a demonstration of the discrimination of phases in a spray field; an assessment of atomizer symmetry with respect to fuel distribution; and a characterization of a droplet field in a reacting spray. It is noted that the above technique is especially powerful in delineating droplet interactions in the swirling, complex flows typical of realistic systems.

Mcdonell, V. G.↗

A proof of concept investigation: A unique mobility spectrometer for In Situ diagnostics of positive and negative ion distributions in the mesosphere and lower ionosphere

We have carried out a proof-of-concept development and test effort that not only promises the reduction of parasitic effects of surface contamination (therefore increasing the integrity of 'in situ' measurements in the 60-130 km regime), but promises a uniquely expanded measurement set that includes electron densities, plasma conductivities, charged-particle mobilities, and mass discrimination of positive and negative ion distributions throughout the continuum to free-molecular-flow regimes. Three different sensor configurations were designed, built and tested, along with specialized driving voltage, electrometer and channeltron control electronics. The individual systems were tested in a variety of simulated space environments ranging from pressures near the continuum limit of 100 mTorr to the collisionless regime at 10(exp -6) Torr. Swept modes were initially employed to better understand ion optics and ion 'beam' losses to end walls and to control electrodes. This swept mode also helped better understand and mitigate the influences of secondary electrons on the overall performance of the PIMS design concept. Final results demonstrated the utility of the concept in dominant single-ion plasma environments. Accumulated information, including theoretical concepts and laboratory data, suggest that multi-ion diagnostics are fully within the instrument capabilities and that cold plasma tests with minimized pre-aperture sheath acceleration are the key ingredients to multi-ion success.

Szuszczewicz, Edward P.↗