Search NASA⌕ Search

SEARCH · Search NASA

Results for “Passive instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SoRcer Test Utqiagvik Deployment for Ionograms (STUDI) Field Campaign Report

The U.S. Air Force Research Laboratory (AFRL) has developed a passive broadband radio frequency (RF) receiver, called a Sounder Receiver (SoRcer), as an ionospheric diagnostic instrument. These systems can produce ionospheric specifications to characterize the local ionosphere. The specifications from the SoRcers can then be used to inform data assimilation models; monitor diurnal, seasonal, or other cyclical changes; and detect irregularities or abnormalities in the ionosphere, such as traveling ionospheric disturbances (TIDs), sporadic E, and spread F.

54 ENVIRONMENTAL SCIENCES↗

Frequency stability of the SRF cavities (microphonics)

There are several proposed experiments to search for Dark Matter that will utilize SRF cavities submerged into liquid Helium. Extremely narrow bandwidth of SRF cavities (<1 Hz) and requirements for cavity frequency stability will be obligated special measures to mitigate any vibrations from external sources that will be penetrated and re-tuned cavity. In the talk recent FNAL experience of measuring microphonics of SRF cavities used for Dark Photon experiment will be presented. FNAL’s program to mitigate SRF cavity microphonics (in passive and active way) will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SORCER TEST UTQIAĠVIK DEPLOYMENT FOR IONOGRAMS (STUDI) 2021-2024

The Air Force Research Laboratory (AFRL) has developed a passive broadband radio frequency (RF) receiver, called a Sounder Receiver (SoRcer), as an ionospheric diagnostic instrument. These systems can produce ionospheric specifications to characterize the local ionosphere. The specifications from the SoRcers can then be used to inform data-assimilation models; monitor diurnal, seasonal, or other cyclical changes; and detect irregularities or abnormalities in the ionosphere, such as traveling ionospheric disturbances (TIDs), sporadic E, and spread F.

frequency↗

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DAISY Benchmark Performance Data

This repository contains the underlying data from benchmark experiments for Drifting Acoustic Instrumentation SYstems (DAISYs) in waves and currents described in "Performance of a Drifting Acoustic Instrumentation SYstem (DAISY) for Characterizing Radiated Noise from Marine Energy Converters" (https://link.springer.com/article/10.1007/s40722-024-00358-6). DAISYs consist of a surface expression connected to a hydrophone recording package by a tether. Both elements are instrumented to provide metadata (e.g., position, orientation, and depth). Information about how to build DAISYs is available at https://www.pmec.us/research-projects/daisy. The repository's primary content is three compressed archives (.zip format), each containing multiple MATLAB binary data files (.mat format). A table relating individual data files to figures in the paper, as well as the structure of each file, is included in the repository as a Word document (Data Description MHK-DR.docx). Most of the files contain time series information for a single DAISY deployment (file naming convention: [site]_DAISY_[Drift #].mat) consisting of processed hydrophone data and associated metadata. For a limited number of DAISY deployments, the hydrophone package was replaced with an acoustic Doppler velocimeter (file naming convention: [site]_DAISY_[Drift #]_ADV.mat). Data were collected over several years at three locations: (1) Sequim Bay at Pacific Northwest National Laboratory's Marine & Coastal Research Laboratory (MCRL) in Sequim, WA, the energetic tidal channel in Admiralty Inlet, WA (Admiralty Inlet), and the U.S. Navy's Wave Energy Test Site (WETS) in Kaneohe, HI. Brief descriptions of data files at each location follow. - MCRL - (1) Drift #4 and #16 contrast the performance of a DAISY and a reference hydrophone (icListen HF Reson), respectively, in the quiescent interior of Sequim Bay (September 2020). (2) Drift #152 and #153 are velocity measurements for a drifting acoustic Doppler velocimeter in in the tidally-energetic entrance channel inside a flow shield and exposed to the flow, respectively (January 2018). (3) Two non-standard files are also included: DAISY_data.mat corresponds to a subset of a DAISY drift over an Adaptable Monitoring Package (AMP) and AMP_data.mat corresponds to approximately co-temporal data for a stationary hydrophone on the AMP (February 2019). - Admiralty Inlet - (1) Drift #1-12 correspond to tests with flow shielded DAISYs, unshielded DAISYs, a reference hydrophone, and drifting acoustic Doppler velocimeter with 5, 10, and 15 m tether lengths between surface expression and hydrophone recording package (July 2022). (2) Drift #13-20 correspond to tests of flow shielded DAISYs with three different tether materials (rubber cord, nylon line, and faired nylon line) in lengths of 5, 10, and 15 m (July 2022). - WETS - (1) Drift #30-32 correspond to tests with a heave plate incorporated into the tether (standard configuration for wave sites), rubber cord only, and rubber cord, but with a flow shielded hydrophone (November 2022). (2) Drift #49-58 and Drift #65-68 correspond to measurements around mooring infrastructure at the 60 m berth where time-delay-of-arrival localization was demonstrated for different DAISY arrangements and hydrophone depths (November 2022).

16 TIDAL AND WAVE POWER↗

Experimental Report: Multi-Instrument Comparison of AAF Size Distribution Instruments

Aerosols are particles suspended in the atmosphere, ranging in size from nanometers to micrometers. Their size distribution affects key atmospheric processes, including nucleation, coagulation, scavenging, activation, and radiative properties (Seinfeld and Pandis 2016). Aerosol size distribution is a critical parameter in atmospheric science, influencing processes such as cloud formation and radiative forcing. Accurate representation of aerosol size distributions is essential for understanding their impact on climate, air quality, and human health. However, aerosol size and composition vary significantly across time and space due to meteorological conditions and natural or anthropogenic sources. (Wu and Boor 2021). Various instruments are used to measure aerosol size distributions, each with distinct principles, advantages, and limitations. This report begins with an in-depth overview of aerosol size-distribution comparison studies, focusing on the passive cavity aerosol spectrometer probe (PCASP), portable optical particle spectrometer (POPS), ultra-high-sensitivity aerosol spectrometer (UHSAS), aerodynamic particle sizer (APS), and scanning mobility particle sizer (SMPS). All of these instruments are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), which commissioned this comparison and report. The report evaluates the strengths and weaknesses of these instruments, highlights their applications, and discusses efforts to merge data from multiple instruments for comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

Micro-Transfer Printing of Repeaters on Passive Interposer

Silicon-based sensors are central to particle physics experiments and particle tracking detectors. New-generation Large Focal Plane Arrays (LFPAs) cover areas that extend beyond several square meters. Distributing power and transporting data across such areas while maintaining good signal integrity is a complicated challenge. Tiling the detector on an organic interposer would be far too expensive and take too much space while offering little to no advantage regarding signal integrity. Passive silicon interposers are much less expensive and more integrable but would worsen signal integrity because of their inherent higher dielectric constant. Active interposers are a good compromise from the economic and signal integrity standpoint; unfortunately, their yield trends to zero for areas greater than a reticle size, making this technology incompatible with our application. NHanced proposes to duplicate the behavior of a high-yield, low-cost active interposer by printing active microcomponents on a passive interposer with our die-to-wafer micro-transfer printing (MTP) technology. This resolves the signal integrity and power distribution limitations. In Phase I, we designed and simulated analog and digital repeaters to be MTPed onto a passive silicon interposer test wafer.

2.5D↗

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bias‐Dependent Quantum Efficiency Reveals Recombination Pathways in Thin Film Solar Cells

Identifying where recombination predominantly occurs—whether at the front interface, back interface, or throughout the bulk—is crucial for optimizing CdSeTe solar cells and many other photovoltaic device architectures. Here, a simple and effective diagnostic is demonstrated: measuring external quantum efficiency (QE) under varying forward biases. The drift–diffusion simulations reveal that each recombination pathway leaves a distinct bias-induced signature in the normalized QE: a progressive drop at long wavelengths for back-limited devices, a short-wavelength decline for front-limited devices, and a relatively uniform decrease across all wavelengths for bulk-limited devices. These predictions are validated with experiments on As-doped and Cu-doped CdSeTe devices, with and without passivation layers or different front buffers. In each case, the observed bias-dependent QE spectral changes align with the simulated recombination map. Because this method uses standard QE instrumentation, it offers a broadly accessible and cost-efficient means to diagnose recombination pathways—extending beyond CdSeTe to other thin-film and emerging solar cell technologies. By pinpointing recombination bottlenecks, researchers and manufacturers can strategically refine doping profiles, passivation schemes, and interface designs to further improve device performance.

CdTe↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen--a noncondensable gas (NCG), simulating air in the reactor containment--to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted--utilizing iterative and nodalized mass and heat transfer calculation to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results--a ratio of experimental and Nusselt's theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Confirming the absence of nuclear warheads via passive gamma-ray measurements

Arms-control agreements between the United States and Russia negotiated after the end of the Cold War have imposed limits on the number of deployed strategic nuclear weapons. Verification of these agreements has relied on onsite inspections, sometimes supported by radiation detection techniques to confirm the absence of a nuclear warhead when ambiguities arise. So far, these measurements have sought to detect neutron emissions associated with the presence of plutonium, but they would be inadequate for uranium devices. In an effort to offer instruments that could be used to confirm the absence of both plutonium and uranium weapons, here we propose an inspection system that uses only passive gamma radiation detection techniques. Such a system would be particularly valuable for next-generation arms-control agreements that limit total numbers of weapons and would involve containerized items in storage. We conducted extensive Monte Carlo simulations to support the development of a verification protocol and detection algorithm. Here, we demonstrate the viability of the technique using standard laboratory check sources and MCNP simulations for simplified configurations of special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗