Search NASA⌕ Search

SEARCH · Search NASA

Results for “Peel strength”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An Experimental Investigation of Silicone-to-Metal Bond Strength in Composite Space Docking System Seals

The National Aeronautics and Space Administration (NASA) is currently developing a new universal docking mechanism for future space exploration missions called the Low Impact Docking System (LIDS). A candidate LIDS main interface seal design is a composite assembly of silicone elastomer seals vacuum molded into grooves in an electroless nickel plated aluminum retainer. The strength of the silicone-tometal bond is a critical consideration for the new system, especially due to the presence of small areas of disbond created during the molding process. In the work presented herein, seal-to-retainer bonds of subscale seal specimens with different sizes of intentional disbond were destructively tensile tested. Nominal specimens without intentional disbonds were also tested. Tension was applied either uniformly on the entire seal circumference or locally in one short circumferential length. Bond failure due to uniform tension produced a wide scatter of observable failure modes and measured load-displacement behaviors. Although the preferable failure mode for the seal-to-retainer bond is cohesive failure of the elastomer material, the dominant observed failure mode under the uniform loading condition was found to be the less desirable adhesive failure of the bond in question. The uniform tension case results did not show a correlation between disbond size and bond strength. Localized tension was found to produce failure either as immediate tearing of the elastomer material outside the bond region or as complete peel-out of the seal in one piece. The obtained results represent a valuable benchmark for comparison in the future between adhesion loads under various separation conditions and composite seal bond strength.

Gaier, James R.↗

The Role of Water on the Interfacial Adhesion in Si Solar Modules

Delamination of solar module interfaces often occurs in field-tested solar modules after decades of service due to environmental stressors such as humidity. As water diffuses into the module, failure mechanisms like corrosion and delamination are significantly affected. In the presence of water, the interfaces between EVA and the cell, glass, and backsheet all experience losses of adhesion exposing the module to accelerated degradation. Understanding the relation between interfacial adhesion and water content inside PV modules can help mitigate detrimental power losses. Water content measurements via short wave infrared reflectometry combined with 180 degrees peel tests were used to study and quantify the effect of water ingress and egress on adhesion. Changes in adhesion strength for different module interfaces are quantified, correlating spatial distribution of water content to adhesion for damp heat and dry heat exposed samples. After 1000 hours of damp heat exposure, decreases in adhesion strength of approximately 1 N/mm were noted for all interfaces.

adhesion↗

Impact Experiments into Granular Targets Containing Solitary Blocks of Varying Strength and Size

Crater scaling relationships provide a means to correlate dimensions of laboratory-scale impact experiments to naturally formed craters at planetary scales. For relatively larger impact events, where gravity is the dominant arresting force against crater growth, these scaling relations are comparatively simple. For smaller craters, however, the target properties have increasing influence over the cratering process. Further complexities are easily envisaged when considering realistic surfaces that contain small-scale heterogeneities in cohesive strength, density, porosity, friction, as these properties will each have unequal effects on the resultant crater morphometry. Even when produced under controlled laboratory conditions, understanding (and controlling) the entire relevant parameter space is daunting, and deconvolution of the relevant contributors can be complicated even in the best-case scenario. To this end, we have begun an extensive series of impact experiments that will provide a nascent framework that will aid in the interpretation of craters observed on complex natural surfaces throughout the solar system. To start with the simplest configuration, experiments were performed with cylindrical PVC buckets that were filled with quartz sand and contained a single cubic block of synthetic sandstone. The blocks varied in size (14-33 mm) and unconfined compressive strength (0.5-7.4 MPa) and were placed in/on the sand along the trajectory of the incoming impactor and buried to different depths. All experiments were conducted using the vertical gun located in the Experimental Impact Lab at NASA Johnson Space Center with alumina projectiles that were accelerated to ~1.53 km s^-1 under a vacuum of 1 torr. After the impact, target containers were removed from the chamber are morphometric data were extracted by using a Peel 2 3D-scanner in combination with the open-source software, CloudCompare. Initial results show that block strength is a secondary effect on crater diameter and depth, but when at least one edge of the block is exposed and the surface (partial burial) the strength will dictate the number of surviving block fragments around the crater, as well as how much disrupted block material is retained within the crater walls.

Christopher J. Cline II↗

Experimental and analytical study of fatigue damage in notched graphite/epoxy laminates

Both tension and compression fatigue behaviors were investigated in four notched graphite/epoxy laminates. After fatigue loading, specimens were examined for damage type and location using visual inspection, light microscopy, scanning electron microscopy, ultrasonic C-scans, and X-radiography. Delamination and ply cracking were found to be the dominant types of fatigue damage. In general, ply cracks did not propagate into adjacent plies of differing fiber orientation. To help understand the varied fatigue observations, the interlaminar stress distribution was calculated with finite element analysis for the regions around the hole and along the straight free edge. Comparison of observed delamination locations with the calculated stresses indicated that both interlaminar shear and peel stresses must be considered when predicting delamination. The effects of the fatigue cycling on residual strength and stiffness were measured for some specimens of each laminate type. Fatigue loading generally caused only small stiffness losses. In all cases, residual strengths were greater than or equal to the virgin strengths.

Whitcomb, J. D.↗

An Evaluation of Techroll Seal Flexible Joint Material

This study evaluated the materials utilized in the flexible joint for possible failure modes. Studies undertaken included effect of temperature on the strength of the system, effect of fatigue on the strength of the system, thermogravimetric analysis, thermochemical analysis, differential scanning calorimeter analysis, dynamic mechanical analysis, and peel test. These studies indicate that if the joint failed due to a materials deficiency, the most likely mode was excessive temperature in the joint. In addition, the joint material is susceptible to fatigue damage which could have been a contributing factor.

Hall, W. B.↗

Materials testing of the IUS techroll seal material

As a part of the investigation of the control system failure Inertial Upper Stage on IUS-1 flight to position a Tracking and Data Relay Satellite (TDRS) in geosynchronous orbit, the materials utilized in the techroll seal are evaluated for possible failure models. Studies undertaken included effect of temperature on the strength of the system, effect of fatigue on the strength of the system, thermogravimetric analysis, thermomechanical analysis, differential scanning calorimeter analysis, dynamic mechanical analysis, and peel test. The most likely failure mode is excessive temperature in the seal. In addition, the seal material is susceptible to fatigue damage which could be a contributing factor.

Nichols, R. L.↗

Effect of preforming adherends on static and fatigue strength of bonded composite single-lap joints

An analytical and experimental investigation was conducted on bonded composite single-lap joints with the adherends performed to reduce the angle between the line of action of the applied in-plane force and the bondline. A classical closed-form solution was used to analyze the composite joints with various preform angles and overlap lengths. The adherends of the test specimens were preformed before bonding, during the layup and curing process. Static tests were conducted for preform angles of 0, 5, 10, and 15 deg and overlap lengths of 0.75, 1.75, 2.75, and 3.75 in. A limited fatigue study was conducted for specimens with a 2.75-in. overlap and a preform angle of 5 deg. Results of the analysis showed that preforming the adherends of bonded composite single-lap joints significantly reduced the shear and peel stress concentrations in the adhesive. Experimental results showed that preforming the adherends significantly increased their static and fatigue strength and thus increased the load level for which bonded composite single-lap joints can be designed.

Sawyer, J. W.↗

Thin silicon-solar cell fabrication

Flexible silicon slices of uniform thicknesses are fabricated by etching in sodium hydroxide solution. Maintaining uniform thickness across slices during process(fabrication) is important for cell strength and resistance to damage in handling. Slices formed by procedure have reproducible surface with fine orange peel texture, and are far superior to slices prepared by other methods.

Lindmayer, J.↗

Computational Modeling Demonstrates the Joint Clearance Effect on the Tensile Strength of Solder Joints.

Soldered joints can be made with a wide range of base materials and filler metals that allow the assembly to meet its performance and reliability requirements. Structural solder joints have, as their foremost requirement, to provide mechanical attachment between base material structures. The joint is typically subjected to one, or a combination of, three loading configurations: (a) tensile or compressive force, (b) shear force, or (c) peel force. Solder filler metals and in particular, the so-called “soft solders” based on tin (Sn), lead (Pb), and indium (In), generally have a bulk strength that is less than that of the base materials. Finally, deformation occurs largely in the solder when the joint is subjected to an applied force.

36 MATERIALS SCIENCE↗

Density limit in peeling-limited pedestals at and above the Greenwald value in DIII-D high poloidal beta plasmas

High pressure, peeling limited pedestals with pedestal normalized beta β N,ped >2 and pedestal top density n ped at or above the Greenwald density nG have been achieved in DIII-D high poloidal beta plasmas, with high global normalized beta β N >3 and energy confinement H 98 ~1.2-1.7. Higher β N allows higher pedestal density above the Greenwald value and higher pedestal pressure, even with a low injected torque. MHD modeling confirms that the experimental profiles lie near the peeling-mode unstable boundary with high normalized pressure gradient βMHD and high edge current density. Experimental analysis and stability calculations indicate that the high poloidal beta with strong Shafranov shift, high βMHD and weak/negative magnetic shear improves the pedestal stability by decoupling the peeling and ballooning modes and stabilizing the ballooning modes, thus facilitating access to the second stable region of peeling-ballooning mode. The access to the second stable peeling-ballooning stability region opens Super-H-like channels without extremely strong shaping or strong torque injection. The high-pressure peeling pedestal allows the pedestal density to go beyond the Greenwald limit with strong ExB shear maintained: pedestal pressure increases with pedestal density even when n ped >n G , until reaching the ideal MHD instability boundary, where giant ELMs occur. The giant ELMs are dominated by a strong n=1 component and cause a large reduction of the edge pressure, but a negligible change of the core pressure, consistent with kink/peeling-mode induced instability. The pedestal recovers from the collapse and typically sustains a high baseline density, around the Greenwald limit, during the whole discharge duration. Experiments also found that internal transport barriers and n ped ~0.9nG, peeling limited pedestals could be simultaneously achieved in high β N plasmas, while an internal feedback between ITB strength and pedestal performance is found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adhesive-bonded double-lap joints

Explicit analytical solutions are derived for the static load carrying capacity of double-lap adhesive-bonded joints. The analyses extend the elastic solution Volkersen and cover adhesive plasticity, adherend stiffness imbalance and thermal mismatch between the adherends. Both elastic-plastic and bi-elastic adhesive representations lead to the explicit result that the influence of the adhesive on the maximum potential bond strength is defined uniquely by the strain energy in shear per unit area of bond. Failures induced by peel stresses at the ends of the joint are examined. This failure mode is particularly important for composite adherends. The explicit solutions are sufficiently simple to be used for design purposes

Hart-Smith, L. J.↗

Experimental and analytical study of fatigue damage in notched graphite/epoxy laminates

Fatigue damage development in notched graphite/epoxy laminates is investigated in both compression and tension, with tested specimens being examined for damage type and location using light microscopy, scanning electron microscopy, ultrasonic C-scans, and X-radiography. Delamination and ply cracking were found to be the dominant types of fatigue damage. Comparison of observed delamination locations with finite element calculations indicates that both interlaminar shear and peel stresses must be considered when predicting delamination. Fatigue loading generally caused only small stiffness losses, and residual strengths were in all cases greater than, or equal to, the virgin strengths.

Whitcomb, J. D.↗

The Analysis of Adhesive Residue Failure

Adhesives have always been, and will continue to be, a crucial component of assembling flight hardware. Unfortunately, adhesives have a long standing history of being a source of costly contaminations. There are currently no existing documents that can aid a technician in discerning the proper adhesive/substrate combinations, nor the optimal solvent to use when removing adhesive residue. This project seeks to evaluate the performance of adhesive tapes on various flight hardware substrates in order to create an easy-to-use guide for spacecraft ground processing. The analyses performed were the adhesive/solvent solubility, SEM examinations, and peel adhesion tests. The solubility tests showed that amyl acetate, acetone, and MEK were the most successful in dissolving the adhesives. The SEM data gives preliminary insight into the morphology of the residues. Lastly, the peel adhesion testing proved that there is no relationship between the length of time the adhesive was applied and its adhesive strength.

Smiley, Adrienne↗

An Experimental and Numerical Study of Plasma Treatment Effects on Adhesive Joints of Metals, CFRTPs, and Metal–CFRTP Combinations

This work investigates the effects of plasma surface treatment on both the local adherend–adhesive interfacial strength and the global lap shear strength (LSS) of adhesively-bonded joints composed of metals, CFRTPs, and metal-CFRTP combinations, using AA6061 and CFRPPA as representative examples. Experimental and computational results show that plasma treatment improved the ratio of CFRPPA–adhesive interfacial normal strength to adhesive tensile strength (sint,n/scri,t,adhesive) from 0.59–1.00 to 0.91–1.73, leading to an average 90% increase in LSS for CFRPPA-related joints. In contrast, the LSS and sint,n/scri,t,adhesive values of AA6061–AA6061 joints (>=2.27) remained nearly unchanged after plasma treatment. The enhanced joint bonding was further supported by post-failure surface morphologies from three-dimensional profilometry and simulations, showing a transition from dominant interfacial failure to mixed modes involving interfacial, cohesive, and slight fiber-peeling failures. The LSS evolution with respect to sint,n/scri,t,adhesive was numerically established until the saturation of the LSS of various joints, and the behavior of AA6061–CFRPPA T-joints with varying interfacial strengths was also modeled. This study highlights the importance of local interfacial bonding strength, rather than global LSS, for understanding and optimizing the mechanical performance of adhesively-bonded composite–metal and composite-composite structures via different surface modification strategies.

Qiao, Yao (ORCID:0000000265867604)↗

Effects of High-Temperature Annealing in Air on Hi-Nicalon Fiber-Reinforced Celsian Matrix Composites

BN/SiC-coated Hi-Nicalon fiber-reinforced celsian matrix composites (CMC) were annealed for 100 h in air at various temperatures to 1200 C, followed by flexural strength measurements at room temperature. Values of yield stress and strain, ultimate strength, and composite modulus remain almost unchanged for samples annealed up to 1100 C. A thin porous layer formed on the surface of the 1100 C annealed sample and its density decreased from 3.09 to 2.90 g/cu cm. The specimen annealed at 1200 C gained 0.43 wt%, was severely deformed, and was covered with a porous layer of thick shiny glaze which could be easily peeled off. Some gas bubbles were also present on the surface. This surface layer consisted of elongated crystals of monoclinic celsian and some amorphous phase(s). The fibers in this surface ply of the CMC had broken into small pieces. The fiber-matrix interface strength was characterized through fiber push-in technique. Values of debond stress, alpha(sub d), and frictional sliding stress, tau(sub f), for the as-fabricated CMC were 0.31+/-0.14 GPa and 10.4+/-3.1 MPa, respectively. These values compared with 0.53+/-0.47 GPa and 8.33+/-1.72 MPa for the fibers in the interior of the 1200 C annealed sample, indicating hardly any change in fiber-matrix interface strength. The effects of thermal aging on microstructure were investigated using scanning electron microscopy. Only the surface ply of the 1200 C annealed specimens had degraded from oxidation whereas the bulk interior part of the CMC was unaffected. A mechanism is proposed explaining the various steps involved during the degradation of the CMC on annealing in air at 1200 C.

Bansal, Narottam P.↗

Self-consistent core-pedestal ITER scenario modeling

The purpose of these integrated ITER simulations is to identify dependencies that can impact the performance of ITER. The dependence of fusion power production, temperature and density pedestals, and core profiles on varying magnetic-q, edge density fueling strength, neoclassical transport, magnetic field strength, and alpha heating, are examined. It is noted that ion modes usually dominate the interior, while electron modes dominate the barrier. The electron mode without flow shear is substantially stronger. The q increase tends to cause more kinetic ballooning modes at the edge and the q decrease means that the peeling is getting worse, but the ballooning is getting better. The large edge q tends to provide hollow density while small edge q gives normal density profile. This is consistent with the observation that the density of particles is inversely proportional to the density of the plasma current. The rise in the source of the edge particle increases the density of the edge and the reaction rate close to the edge increases temperature fluxes, resulting in weak pedestal barriers. When neoclassical transport is turned off or the strength of B-field is increased, the pronounced edge barriers are identified. In addition, a distinct effect on the magnetohydrodynamic (MHD) modes is observed due to the increased B-field. The interesting aspect is that the barrier collapses about q = 2 as the stability of MHD has decreased to replace the barrier with a continuous slope but with roughly the same fusion power. This would actually be good for a reactor. The slope of the H-mode pedestal is found to be reduced due to the alpha heating. It is expected that the problem of edge-localized modes causing damage to the first wall will be eased. The effects of circular, elongated, and general geometry on plasma profiles are also compared and contrasted. The circular geometry has a hollow density profile and no edge or internal thermal transport barrier (ETB or ITB). However, both ETBs and ITBs can be found in the elongated geometry. In general geometry, there is a weaker ETB, comparable ITBs, but a higher edge particle transport barrier than in elongated geometry. Higher density near the edge, on the other hand, causes more wall erosion, so elongated geometry might be the best option.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The looped adhesive strip: An example of coplanar delamination interaction

The phenomenon of peeling and debonding of thin layers is a subject of interest to those concerned with adhesives, thin films, and layered materials. In recent years much attention has been focused on such problems as a result of increased interest and application of advanced composites and thin film coatings. A related problem which is of interest for its own sake but also represents a simple example of a tangled adhesive strip and of coplanar delamination interaction, is the problem of a looped adhesive strip. This is the subject of the present study. Researchers consider here the problem of an elastic strip which possesses an adherend on (at least) one of its surfaces. If the strip is deformed so that two portions of such a surface are brought into contact, a position of the strip becomes bonded and a loop is formed. Researchers are interested in determining the equilibrium configuration of such a strip and investigating the behavior of the strip when its edges are pulled apart. The problem is approached as a moving interior boundary problem in the calculus of variations with the strip modeled as an inextensible elastica and the bond strength characterized by its surface energy. A Griffith type energy criterion is employed for debonding, and solutions corresponding to the problem of interest obtained. The solution obtained will be seen to predict the interesting phenomenon of bond point propagation, as well as the more standard peeling type behavior. Numerical results demonstrating the phenomena of interest are presented as well and will be seen to reveal both stable and unstable propagation of the boundaries of the bonded portion of the strip, depending upon the loading conditions.

Bottega, W. J.↗

The Effects of Peel Ply on the Damage Tolerance Characteristics of the Space Launch System (SLS) Payload Adapter Fitting (PAF)

A payload adaptor fitting (PAF) has been manufactured at NASA’s Marshall Space Flight Center (MSFC) in support of the Space Launch System (SLS) program. This structure is essentially a large cone made up of eight curved “lobes” that are joined together to form the cone. The lobes were manufactured via automated fiber placement (AFP). The PAF will carry predominantly compressive loads thus compression strength will be the focus of this study. The lobes are sandwich structure made with aluminum honeycomb core and carbon/epoxy face sheets. The lobes will be inserted into metallic rings at the top and bottom of the cone to form the full cone. Both front and back exterior surfaces of each lobe have a plain weave fabric placed at ±45⁰ to the vertical direction to help prevent fiber “breakout” during drilling. The face sheet of each lobe is thickest at the top and plies are dropped as the cone reaches the main acreage in the bottom section of the cone. The entire structure used resin impregnated peel ply that, once removed, supplies a good bonding surface for secondary bonding steps. The peel ply can be removed either directly after cure, or just before any bonding operation. Since foreign object impact can occur to the structure at any time during its life, damage tolerance of the PAF structure both with and without peel ply needed to be addressed because a previous study, albeit with limited data, showed some significant differences in damage tolerance whether the peel ply was present or not [1]. A literature search showed no results for comparing impact damage on composite laminates with and without peel ply. Load versus deflection of impact curves, visual damage, dent depth, damage as ascertained by thermography and cross-sectional microscopy were evaluated as part of the damage resistance of the structure. Compression After Impact (CAI) was performed to assess damage tolerance. The impact tests were conducted on representative specimens both with and without the peel ply present.

Sandwich Structure↗