Precise mass measurement of the longest odd-odd chain of nuclei with 1+ ground states

Precise mass measurements of the ground and isomeric states of the odd-odd Rh108,110,112,114,116 were performed using the Canadian Penning Trap at Argonne National Laboratory, showing good agreement with recent JYFLTRAP measurements. A new possible isomeric state of Rh114 was also observed. These isotopes are part of the longest odd-odd chain of identical ground-state spin-parity assignment of 1+, spanning Rh104–118, despite being in a region of deformation. Realistic phenomenological mean-field calculations using the “universal” Wood-Saxon Hamiltonian were performed, which explained this phenomenon for the first time. In addition, multiquasiparticle blocking calculations were performed to study the configuration of low-lying states in the odd-odd Rh nuclei, elucidating anomalous isomeric yield ratio observed for Rh114.

Liu, B↗

Direct Mass Measurements to Inform the Behavior of 128m $\mathrm{Sb}$ in Nucleosynthetic Environments

Nuclear isomer effects are pivotal in understanding nuclear astrophysics, particularly in the rapid neutron-capture process where the population of metastable isomers can alter the radioactive decay paths of nuclei produced during astrophysical events. The β-decaying isomer 128m Sb was identified as potentially impactful since the β-decay pathway along the A = 128 isobar funnels into this state bypassing the ground state. Here we report the first direct mass measurements of the 128 Sb isomer and ground state using the Canadian Penning Trap mass spectrometer at Argonne National Laboratory. We find mass excesses of -84564.8(25) keV and -84608.8(21) keV, respectively, resulting in an excitation energy for the isomer of 43.9(33) keV. These results provide the first key nuclear data input for understanding the role of 128m Sb in nucleosynthesis, and we show that it will influence the flow of the rapid neutron-capture process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass of 101 Sn and Bayesian extrapolations to the proton drip line

The favorable energy configurations of nuclei at magic numbers of 𝑁 neutrons and 𝑍 protons are fundamental for understanding the evolution of nuclear structure. The 𝑍 = 50 (tin) isotopic chain is a frontier for such studies, with particular interest at and around the doubly magic 100 Sn isotope, for which the mass is a topic of debate. Precise mass values for neutron-deficient isotopes provide necessary anchor points for mass models to test extrapolations near the proton drip line, where experimental studies remain out of reach. In this work, we report a Penning trap mass measurement of 101 Sn . The determined mass excess of −59889.89⁢(96) keV for 101 Sn represents a factor-of-300 improvement over the current precision and indicates that 101 Sn is less bound than previously thought. Mass predictions from a recently developed Bayesian model combination framework employing statistical machine learning and nuclear masses computed within seven global models based on nuclear density functional theory agree within 1⁢𝜎 with experimental masses from the 48 ≤ 𝑍 ≤ 52 isotopic chains. The framework's resilience to new mass data gave confidence in the extrapolation of tin masses down to 𝑁 = 46. Our calculations suggest that 96 Sn is a two-proton drip line nucleus and predict a mass excess of −58090⁢(800) keV for 100 Sn , showing a preference within 1⁢𝜎 for the mass of 100 Sn derived from the 𝛽-delayed 𝑄 value measured at GSI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Suppression of Penning discharges between the KATRIN spectrometers

Abstract The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)-neutrino mass with a sensitivity of 0.2eV/c $$^2$$ 2 by precisely measuring the endpoint region of the tritium $$\beta $$ β -decay spectrum. It uses a tandem of electrostatic spectrometers working as magnetic adiabatic collimation combined with an electrostatic (MAC-E) filters. In the space between the pre-spectrometer and the main spectrometer, creating a Penning trap is unavoidable when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, “electron catchers” were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Fission Products at CARIBU: Near Field Detection (Q2/FY22 Quarterly Progress Report)

We continued our work on preparation for the upcoming branching ratio measurements. The CARIBU facility has not been delivering radioactive beams since January this year due to an issue with the magnet that is used for mass separation. The parts needed to be replaced to fix the issue has been since ordered, shipped from Germany, and installed at CARIBU. The CARIBU is now operational and the first experiments that are ran will be those that had to be cancelled in January due to the facility complications, and we are in a position to schedule our next sample collection. In the meantime, we have been continuing work on data analysis of fission product mass measurements in the Canadian Penning Trap. This analysis is now complete. We continue our outreach to recruit a graduate student who would be interested in working with us on this project. In the past month, we have a conversation with a potential student at UC Berkeley and Texas A&M. There students are still to decide if they would accept the offer to these graduate schools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving Fission Products at CARIBU: Near Field Detection (Q1/FY24 Quarterly Progress Report)

The article on “Direct Mass Measurements to Inform the Behavior for 128mSb in Nucleosynthesis Environments” by Daniel Hoff et al., recently published in Physical Review Letters. The results of the work are a combination of an extraordinary work on precision mass measurements performed with the Canadian Penning Trap at ANL (the most precise mass measurement of the ground state and the isomeric state in 128Sb performed to date), and an extensive nucleosynthesis theory calculation that include isomers performed by the theorists at LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Static properties of a non-neutral Be-9(+)-ion plasma

The paper reports measurements of the static properties of laser-cooled nonneutral Be-9(+)-ion plasmas stored in Penning traps (PT) under a variety of experimental conditions. The shape, rotation frequency, density, and temperature of the ions were measured as functions of the PT potential and laser-cooling configuration. Within experimental error, the ion plasmas rotate without shear and exhibit approximate thermal equilibrium.

Brewer, L. R.↗

Scaling and performance portability of the particle-in-cell scheme for plasma physics applications through mini-apps targeting exascale architectures

We perform a scaling and performance portability study of the particle-in-cell scheme for plasma physics applications through a set of mini-apps we name "Alpine", which can make use of exascale computing capabilities. The mini-apps are based on Independent Parallel Particle Layer, a framework that is designed around performance portable and dimension independent particles and fields. We benchmark the simulations with varying parameters such as grid resolutions (5123 to 20483) and number of simulation particles (109 to 1011) with the following mini-apps: weak and strong Landau damping, bump-on-tail and two-stream instabilities, and the dynamics of an electron bunch in a charge-neutral Penning trap. We show strong and weak scaling and analyze the performance of different components on several pre-exascale architectures such as Piz-Daint, Cori, Summit and Perlmutter. While the scaling and portability study helps identify the performance critical components of the particle-in-cell scheme in the current state-of-the-art computing architectures, the mini-apps by themselves can be used to develop new algorithms and optimize their high performance implementations targeting exascale architectures.

Muralikrishnan, Sriramkrishnan↗

RF Manipulation and Detection of Protons in the High Performance Antiproton Trap (HiPAT) Experiment

HiPAT is a Penning-Malmberg trap designed to contain 10(exp 12) particles diagnostics of the plasma. Destructive particle detection is performed by extracting trapped ions from HiPAT and colliding them with a microchannel plate detector (providing number and energy information). The improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axd, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions. In addition, plasma modeling efforts have been started using the XOOPIC code.

Martin, James↗

Thermal equilibrium of collisional non-neutral plasma in a magnetic dipole trap

This paper discusses thermal equilibrium states of single-species plasmas, such as pure electron plasmas and pure positron plasmas, that are confined in a dipole trap. Thermal equilibrium states for such plasmas are routinely realized in the homogeneous magnetic field of Penning–Malmberg traps. We generalize the theory of these states to include inhomogeneous magnetic dipole fields. The approach to thermal equilibrium takes place in two stages with well separated time scales. On the collision time scale, thermal equilibrium is established along each magnetic field line. On the much longer transport time scale, heat conduction and viscosity bring the plasmas on different flux contours into thermal equilibrium, we call this a state of global thermal equilibrium. We present numerical results for local and global thermal equilibria. These results agree with the analytic predictions for charge collections that are large compared with the Debye length. There is, in principle, no limit to the confinement time of a single-species plasma in a global thermal equilibrium state. Experiments with hot electron–ion plasmas performed in the LDX and RT1 devices give us confidence that, in contrast to a Penning–Malmberg trap, a magnetic dipole field can also confine cold quasi-neutral electron–positron pair plasmas on the time scale of the phenomena of interest. Such pair plasmas are assumed to form in the magnetosphere of neutron stars but have so far not been realized in a laboratory. The creation of an electron–positron pair plasma is the main goal of the APEX collaboration.

Steinbrunner, P. (ORCID:0000000317693686)↗

Non-neutral plasma manipulation techniques in development of a high-capacity positron trap

Preliminary experiments have been performed toward the development of a multi-cell Penning–Malmberg trap for the storage of large numbers of positrons (≥10 10 e + ). We introduce the master-cell test trap and the diagnostic tools for first experiments with electrons. The usage of a phosphor screen to measure the z-integrated plasma distribution and the number of confined particles is demonstrated, as well as the trap alignment to the magnetic field ( B = 3.1 T) using the m = 1 diocotron mode. The plasma parameters and expansion are described along with the autoresonant excitation of the diocotron mode using rotating dipole fields and frequency chirped sinusoidal drive signals. We analyze the reproducibility of the excitation and use these findings to settle on the path for the next generation multi-cell test device.

Singer, M.↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment

Many space propulsion concepts exist that use matter-antimatter reactions. Current antiproton production rates are enough to conduct proof-of-principle evaluation of these concepts. One enabling technology for such experiments is portable storage of low energy antiprotons, to transport antiprotons to experimental facilities. To address this need, HiPAT is being developed, with a design goal of containing 10(exp 12) particles for up to 18 days. HiPAT is a Penning-Malmberg trap with a 4 Tesla superconductor, 20kV electrodes, radio frequency (RF) network, and 10(exp -13) Torr vacuum. 'Normal' matter is being used to evaluate the system. An electron beam ionizes background gas in situ, and particle beams are captured dynamically. The experiment examines ion storage lifetimes, RF plasma diagnostics, charge exchange with background gases, and dynamic ion beam capture.

Martin, James J.↗

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision mass measurement of Si 24 and a refined determination of the r p process at the A = 22 waiting point

We report a high-precision mass measurement of 24 Si, performed with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory. The atomic mass excess, 10 753.8 (37) keV, is a factor of 5 more precise than previous results. This substantially reduces the uncertainty of the 23 Al(p ,γ) 24 Si reaction rate, which is a key part of the rapid proton capture (rp) process powering type I x-ray bursts. Furthermore, the updated rate constrains the onset temperature of the (α,p) process at the 22 Mg waiting point to a precision of 9%.

20 ≤ A ≤ 38↗

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instability of an electron-plasma shear layer in an externally imposed strain flow

The E x B shear instability of a two-dimensional (2D) filament (i.e., a thin, rectangular strip perpendicular to the magnetic field) of magnetized pure electron plasma is investigated experimentally in the presence of an externally imposed strain flow. Data are acquired using a specialized Penning–Malmberg trap in which strain flows can be applied in 2D by biasing segmented electrodes surrounding the plasma. The E x B drift dynamics are well-described by the Drift-Poisson equations, which are isomorphic to the 2D Euler equations describing ideal fluids. Thus, the experimental results correspond to the Rayleigh instability of a shear layer in a 2D ideal fluid, where the electron density is analogous to the fluid vorticity. Shear layers are prepared by stretching initially axisymmetric electron vortices using a strong, applied strain flow. The data at early times are in quantitative agreement with a linear model which extends Rayleigh’s work to account for the influence of an external strain flow. In the presence of weak strain, the system approximately maintains a phase relationship that corresponds to an instantaneous Rayleigh eigenmode. The instability develops into the nonlinear regime later in time and at smaller spatial scales as the strain rate is increased. A secondary vortex pairing instability is observed, but it is suppressed when the strain-to-vorticity ratio exceeds roughly 0.025. In this way, vorticity transport perpendicular to the filament is diminished due to the applied strain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron resonance (ECR) magnetometry with a plasma reservoir

The local magnetic field in a Penning–Malmberg trap is found by measuring the temperatures that result when electron plasmas are illuminated by microwave pulses. Multiple heating resonances are observed as the pulse frequencies are swept. The many resonances are due to electron bounce and plasma rotation sidebands. The heating peak corresponding to the cyclotron frequency resonance is identified to determine the magnetic field. A new method for quickly preparing low density electron plasmas for destructive temperature measurements enables a rapid and automated scan of microwave frequencies. This technique can determine the magnetic field to high precision, obtaining an absolute accuracy better than 1 ppm and a relative precision of 26 ppb. One important application is in situ magnetometry for antihydrogen-based tests of charge-parity-time symmetry and of the weak equivalence principle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma temperature measurement with a silicon photomultiplier (SiPM)

The temperature of a nonneutral plasma confined in a Penning–Malmberg trap can be determined by slowly lowering one side of the trap’s electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles escape the trap as a function of the barrier height. In many experiments, the escaping particles are directed toward a microchannel plate, and the resulting amplified charge is collected on a phosphor screen. The screen is used for imaging the plasma but can also be used as a Faraday cup (FC) for a temperature measurement. The sensitivity limit is then set by microphonic noise enhanced by the screen’s high-voltage bias. Alternately, a silicon photomultiplier (SiPM) can be employed to measure the charge via the light emitted from the phosphor screen. This decouples the signal from the microphonic noise and allows the temperature of colder and smaller plasmas to be measured than could be measured previously; this paper focuses on the advantages of a SiPM over a FC.

Hunter, E. D. (ORCID:0000000236242840)↗